• Title/Summary/Keyword: Posture & Activity Analysis

Search Result 116, Processing Time 0.029 seconds

The Influence of Position Change on Autonomic Nervous System Function (자세변화가 자율신경계에 미치는 영향)

  • Kim, In-Bae;Kim, Eun-Kyung;Kang, Jong-Ho
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.9 no.1
    • /
    • pp.63-68
    • /
    • 2014
  • PURPOSE: The purpose of this study was to examine the position changes with tilt table on autonomic nervous system using heart rate variability analysis. METHODS: Fourty healthy adult males volunteered in this study. The low frequency, high frequency and low frequency/high frequency ratio and mean heart rate, standard deviation of all normal R-R intervals, root mean square of successive differences, heart rate variability index were measured at the tilt table angle of $0^{\circ}$, $45^{\circ}$ and $90^{\circ}$ with pulsoximeter. Data were analyzed one-way ANOVA and LSD post hoc test. RESULTS: The mean heart rate, low frequency and low frequency/high frequency ratio increased significantly at higher angle of tilt table(p<.05). The root mean square of successive differences, heart rate variability index decreased significantly at lower angle of tilt table(p<.05). The standard deviation of all normal R-R intervals, high frequency decreased at higher angle of tilt table did not show significant difference. CONCLUSION: The symphathetic activity increased significantly at higher angle of tilt table. The parasymphathetic activity decreased at higher angle of tilt table, but the difference were not significant. The autonomic adaptation, balance and heart rate variability decreased significantly at higher angle of tilt table. Based on these results, in the treatment of patients with a change in posture precedence should be carefully treated. Further studies are necessary to determine the most safety and effective methods.

Effect of Backrest Height on Biomechanics Variables During VDT (Visual Display Terminal) Work (VDT 작업 시 의자 등받이 높이가 생체역학적 변인에 미치는 영향)

  • Jinjoo Yang;Sukhoon Yoon;Sihyun Ryu
    • Korean Journal of Applied Biomechanics
    • /
    • v.33 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • Objective: This study identifies the difference among the heights of a chair's backrest (High, Mid, No), the biomechanical changes chair users undergo over time, and the variables that can measure musculoskeletal disorders, eventually providing information on the appropriate type of backrest. Method: Eleven healthy subjects in their 20s and 30s who had no experience with musculoskeletal disorders or surgical operations within the last 6 months participated in this study. Computer typing tasks were randomly designated and performed according to the type of chair backrest, and evaluation was performed for Flexion-Relaxation Ratio (FRR) analysis after the computer typing tasks. This study used eight infrared cameras (sampling rate: 100 Hz) and nine-channel electromyography (sampling rate: 1,000 Hz). ANOVA with repeated measures was conducted to verify the results, with the statistical significance level being α = .05. Results: Although there was no significant difference in craniovertebral angle (CVA), this study showed time and interaction effects depending on the height of the backrest (p<.05). When working without the backrest, the head-spine angle was lower compared to the chairs with backrest, based on the computer work. As for the head angle, the higher the back of the chair was, the less the head flexion and the body angle became, whereas the body flexion became less when there was a backrest. In addition, the body flexion increased over time in all types of backrests (p<.05). The muscle activity of the upper body tended to be high in the high backrest chair. On the other hand, a lower muscle activity was found with a low backrest. Conclusion: These results show that a chair is more ergonomic when the body angle is correctly set without bending and when it is supported by a low backrest. Accordingly, this study determines that the backrest affects shoulder and neck musculoskeletal disorders during typing and that medium-height backrest chairs can help prevent musculoskeletal disorders, contrary to the expectation that high-backrest chairs are preferable.

A Movement Tracking Model for Non-Face-to-Face Excercise Contents (비대면 운동 콘텐츠를 위한 움직임 추적 모델)

  • Chung, Daniel;Cho, Mingu;Ko, Ilju
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.10 no.6
    • /
    • pp.181-190
    • /
    • 2021
  • Sports activities conducted by multiple people are difficult to proceed in a situation where a widespread epidemic such as COVID-19 is spreading, and this causes a lack of physical activity in modern people. This problem can be overcome by using online exercise contents, but it is difficult to check detailed postures such as during face-to-face exercise. In this study, we present a model that detects posture and tracks movement using IT system for better non-face-to-face exercise content management. The proposed motion tracking model defines a body model with reference to motion analysis methods widely used in physical education and defines posture and movement accordingly. Using the proposed model, it is possible to recognize and analyze movements used in exercise, know the number of specific movements in the exercise program, and detect whether or not the exercise program is performed. In order to verify the validity of the proposed model, we implemented motion tracking and exercise program tracking programs using Azure Kinect DK, a markerless motion capture device. If the proposed motion tracking model is improved and the performance of the motion capture system is improved, more detailed motion analysis is possible and the number of types of motions can be increased.

Effect of the Configuration of Contact Type Textile Electrode on the Performance of Heart Activity Signal Acquisition for Smart Healthcare (스마트 헬스케어를 위한 심장활동 신호 검출용 접촉식 직물전극의 구조가 센싱 성능에 미치는 영향)

  • Cho, Hyun-Seung;Koo, Hye-Ran;Yang, Jin-Hee;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Jeong-Hwan;Kwak, Hwy-Kuen;Ko, Yun-Su;Oh, Yun-Jung;Park, Su-Youn;Kim, Sin-Hye;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.4
    • /
    • pp.63-76
    • /
    • 2018
  • The purpose of this study was to investigate the effect of contact type textile electrode structure on heart activity signal acquisition for smart healthcare. In this study, we devised six contact type textile electrodes whose electrode size and configuration were manipulated for measuring heart activity signals using computerized embroidery. We detected heart activity signals using a modified lead II and by attaching each textile electrode to the chest band in four healthy male subjects in a standing static posture. We measured the signals four times repeatedly for all types of electrodes. The heart activity signals were sampled at 1 kHz using a BIOPAC ECG100, and the detected original signals were filtered through a band-pass filter. To compare the performance of heart activity signal acquisition among the different structures of the textile electrodes, we conducted a qualitative analysis using signal waveform and size as parameters. In addition, we performed a quantitative analysis by calculating signal power ratio (SPR) of the heart activity signals obtained through each electrode. We analyzed differences in the performance of heart activity signal acquisition of the six electrodes by performing difference and post-hoc tests using nonparametric statistic methods on the calculated SPR. The results showed a significant difference both in terms of qualitative and quantitative aspects of heart activity signals among the tested contact type textile electrodes. Regarding the configurations of the contact type textile electrodes, the three-dimensionally inflated electrode (3DIE) was found to obtain better quality signals than the flat electrode. However, regarding the electrode size, no significant difference was found in performance of heart signal acquisition for the three electrode sizes. These results suggest that the configuration method (flat/3DIE), which is one of the two requirements of a contact type textile electrode structure for heart activity signal acquisition, has a critical effect on the performance of heart activity signal acquisition for wearable healthcare. Based on the results of this study, we plan to develop a smart clothing technology that can monitor high-quality heart activity without time and space constraints by implementing a clothing platform integrated with the textile electrode and developing a performance improvement plan.

Ergonomic Evaluation of Young Agricultural Operators Using Handle Equipment Through Electromyography and Vibrations Analysis Between the Fingers

  • Federico Roggio;Ermanno Vitale;Veronica Filetti;Venerando Rapisarda;Giuseppe Musumeci;Elio Romano
    • Safety and Health at Work
    • /
    • v.13 no.4
    • /
    • pp.440-447
    • /
    • 2022
  • Background: Agricultural handle equipment is present on all production areas' farms. They are handy and portable; however, excessive use can lead to acute traumas or accidental injuries. Repetitive movements, awkward postures, and hand-arm vibrations predispose them to pain and work-related musculoskeletal disorders. The purpose of this study was to observe the interaction of handle equipment in terms of electromyographic activity and analyze the postural work-related alterations. Materials and methods: Twenty male agricultural operators, mean age 24±1.54 years, underwent the electromyographic analysis testing their muscular activities with a brushcutter, electric saw, and hedge trimmer in four different test conditions. Results: The brushcutter proved to be the agricultural handle equipment with the higher mean frequency (3.37±0.38 Hz) and root mean square (5.25±1.24 ms-2). Furthermore, the digital postural analysis showed a general asymmetry of the main arm and the respective side of the trunk. The head resulted right inclined in the anterior frontal plane by 5.7°±1.2°; the right scapula lower than the left in the posterior frontal plane (8.5°±1.8°), and a working trunk inclination of 34.15°±5.7°. Conclusions: Vibrations of handle equipment and awkward working postures represent a risk for agricultural operators. Preventive measures are required to avoid young operators from experiencing musculoskeletal disorders all lifelong.

Ergonomic Design of Medic Work Table (MWT) for Medical Technologist

  • Choi, Kyeong-Hee;Lee, Sung-Yong;Lee, Jun-Hyub;Kong, Yong-Ku
    • Journal of the Ergonomics Society of Korea
    • /
    • v.35 no.6
    • /
    • pp.595-609
    • /
    • 2016
  • Objective: The purpose of this study was to develop and validate the guidelines for Medic Work Table (MWT) based on the anthropometric data of medical technologists. Background: Users' anthropometric data such as sitting height, sitting elbow height, knee height, and so on are significant factors for designing comfortable and useful furniture. Thus, many guidelines for different types of desks and chairs based on the users' anthropometric data have been suggested to many researchers. However, few researches have been conducted to provide design guidelines for MWT for blood collecting task. Medical technologists often use their upper extremities to perform blood collecting task with high repetitions. These repeated motions could be a critical factor in the prevalence rate of Work-related Musculoskeletal Disorders (WMSDs). Therefore, a study on ergonomic design of MWT would be essential in preventing the WMSDs and improving the quality of the working environment of medical technologists. Method: This study suggested design guidelines for ergonomic MWT by focusing on the heights of the upper side and underside, depths of the inside and outside, and width of MWT through anthropometric studies and literature reviews. Afterwards, a new MWT was made using the suggested design guidelines for this study. Five healthy medical technologists participated to evaluate the original MWT and new MWT. All participants took part in the range of motion (ROM) test, electromyography (EMG) muscle activity test, and usability test to validate the suggested guidelines in this study. EMG signals of related muscles (Flexor Carpi Ulnaris, Extensor Carpi Ulnaris, Deltoid Anterior, and Biceps Branchii) were recorded through the surface electromyography system from both the original MWT and the new MWT. The ROM test of the shoulder and elbow flexion was also assessed using motion sensors. Results: The newly designed MWT showed decreased ROMs of the shoulder and elbow up to 22% and 18% compared to the original MWT. The muscle activities in the new MWT also showed a decrease of 13% in Anterior Deltoid, 6% in Biceps Brachii, 5% in Flexor Carpi Ulnaris, and 8% in Extensor Carpi Ulnaris muscle groups, compared to the original MWT. In the usability test, the satisfaction score of the new MWT was also 56.1% higher than that of the original MWT. Conclusion: This study suggested guidelines for designing MWT and validating the guidelines through qualitative and quantitative analyses. The results of motion analysis, muscle activity, and usability tests demonstrated that the newly designed MWT may lead to less physical stress, less awkward posture, and better physical user interface. Application: The recommended guidelines of the MWT would be helpful information for designing an ergonomic MWT that reduces physical loads and improves the performance of many medical technologists.

Analysis of Joint Movements and Changes of Muscle Length During STS(sit-to-stand) at Various Sitting Heights in the Korean Elderly's daily life (한국 고령자의 일상생활 중 다양한 높이에서의 STS(sit-to-stand) 시 관절운동 특성 및 근길이 변화 분석)

  • Hwang, S.J.;Son, J.S.;Kim, J.Y.;Kim, H.D.;Lim, D.H.;Kim, Y.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.6
    • /
    • pp.484-492
    • /
    • 2008
  • Sit to stand(STS) movement is one of the most common activity in daily life. In addition, Korean traditionally stand up from various sitting heights in one's daily life compared to other foreigners. As Korea enter rapidly to the aging society, needs of the elderly's independent life are increasing. Therefore the importance of research about the analysis of elderly's activity in daily life is rapidly increasing. In this study, we analyzed joint movements and changes of muscle length during STS(sit-to-stand) at various sitting heights(table seat, bath seat, bottom) in the Korean elderly's daily life by using the motion analysis and musculoskeletal modeling. Ten Korean elderly and young were participated in this experiment. Three heights of sitting posture which could represent typical sitting in Korean daily life were chosen as table seat(42cm), bath seat(21cm) and bottom(0cm). As the results, the elderly showed both smaller knee/hip flexion and larger trunk flexion relatively in comparison to the young during table seat STS. The elderly also showed larger dorsiflexion and smaller ROM of knee, hip, trunk compared to the young during bath seat STS. Additionally, the elderly showed larger plantarflexion, hip flexion, smaller knee flexion and trunk flexion during the first half of bottom STS and larger knee flexion, hip flexion and trunk flexion during the second half of bottom STS. In addition, we could know contraction and relaxation characters of major muscles in lower limb during various STS through the analysis of changes in muscle length by musculoskeltal modeling.

A Myometric and Electromyographic Analysis of Hip Abductor Musculature in Healthy Right-Handed Persons (股關節外轉の時の中臀筋の筋力及び活動電位の變化に關する硏究)

  • Kwon, Hyuk-Cheol
    • Physical Therapy Korea
    • /
    • v.5 no.4
    • /
    • pp.41-51
    • /
    • 1998
  • The right hip abductor musculature has been reported to demonstrate "stretch weakness" attributable to chronic elongation imposed by standing posture common to right-handed healthy persons. Kendall and associates have described the concept of "stretch weakness",. The purpose of this study was to assess isometric hip abduction torque and surface electromyographic activity (using MYOMED 432) in a sample of 40 healthy right-handed persons (20 male, 20 female), all of whom agreed to participate in the study, and compare side difference in the hip abductor musculature. In order to assure the statistical significance of the results, the paired t test was applied at the .05 level of significance. The results were as follows: 1) The difference in apparent leg length of right and left legs was significant at the .05 level. 2) There was a significant difference between right and left pelvic height (standing position) at the 05 level measurements, and scapula height at the .05 level. 3) Power measurements and action potentials of right hip abductor were greater than the left hip abductor regardless of the range of joint motion (inner range, outer range) 4) The difference in muscle power and action potentials according to inner or outer range of both hip abductor were significant at the .05 level. 5) In supine during active left hip abduction, the appearance of action potentials in the right hip abductors is indicative of contra-lateral effect (p<.05) These results suggest: In healthy right-handed persons, the apparent leg length on the right is longer than on the left, and pelvic height is elevated on the right side. Muscle those and muscle action potentials of the right hip abductor are higher than those of the left hip abductor in the lengthened position. Therefore, the results in this study are contrary to Kendall's. This type of study should be carried out in many physical therapy departments.

  • PDF

Ergonomic Evaluation of Trunk-Forearm Support Type Chair

  • Lim, Seung Yeop;Won, Byeong Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.2
    • /
    • pp.143-153
    • /
    • 2014
  • Objective: The aim of this study is to investigate the effects of trunk-forearm supported sitting on trunk flexion angle, trunk extensor fatigue and seat contact pressure. Background: The relationship between sitting posture and musculoskeletal disorders of the trunk extensor fatigue and seat contact pressure has been documented. The trunk-forearm support type ergonomic chair was devised from the fact that trunk-forearm support has been reported to reduce trunk extensor activity and discomfort. Method: Using three different sitting postures, upright ($P_1$), trunk-forearm supported ($P_2$) and normal sitting ($P_3$), six healthy subjects participated in the study. Motion capture system was used to collect head and trunk flexion angle, and surface electromyography (sEMG) was used to collect myoelectric signal of upper trapezius, lower trapezius, erector spinae, multifidus, and pressure mat system was used to measure seat contact pressure. Results: When trunk and forearm were supported by the ergonomic chair, higher head flexion angle showed upright > trunk-forearm supported > normal in order, and muscle fatigue showed less than upright and normal sitting. Mean seat contact pressure decreased 19% than upright sitting. But muscle fatigue was not affected by each condition. Conclusion: Trunk-forearm supported sitting of the ergonomic chair showed positive effect in respect of trunk and head flexion angle, trunk extensor fatigue, seat contact pressure. To acquire comprehensive understanding of the effectiveness of the ergonomic chair, further studies such as anatomical effects from measurement of external applied loading effect to the body from interface pressure analysis are required. Application: The results of the publishing trend analysis might help physiological effects of trunk-forearm support type chair.

A Comparison of Compensatory Muscle Activation of Gluteus Maximus and Gluteus Medius in Subjects With and Without Chronic Ankle Instability During Three Functional Postures (세 가지 기능적 자세에서 만성발목불안정성의 대상자와 정상인의 대둔근과 중둔근 보상적 근활성도 비교)

  • Oh, Hee-Joo;Kim, Mi-Sun;Choi, Jong-Duk
    • Physical Therapy Korea
    • /
    • v.22 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • The purpose of this study was to compare the change in electromyography (EMG) activity in the gluteus maximus (G-max) and the gluteus medius (G-med) in subjects with and without chronic ankle instability (CAI) during three functional postures. Twenty four females were recruited for this study. Subjects were assigned into two groups: with CAI ($n_1=12$) and without CAI ($n_2=12$). The assessment postures were rotational squat, one leg stand above a gradient and crossed leg-sway. Electromyographic activities of the G-max and the G-med were recorded using surface EMG and was normalized using the maximal voluntary isometric contraction elicited using a manual muscle testing. Independent t-test was used to determine the statistical differences between two groups during the three functional postures. The comparisons of the three posture between two groups were performed using a one-way repeated analysis of variance. A Bonferroni adjustment used for post hoc analysis. The activation of EMG on G-max performing the one leg stand above a gradient and crossed leg-sway in subjects with CAI is significantly higher than normal group (p<.05). The activation of EMG on the G-max during the rotational squat was significantly increased, compared to those of the one leg stand above a gradient and crossed leg-sway (p<.05). The activation of EMG on G-med performing three exercise at CAI is significantly higher than normal group (p<.05). The activation of EMG on the G-med during the crossed leg-sway was significantly increased, compared to the rotational squat (p<.05). This study provides valuable information for clinician who research CAI.