• Title/Summary/Keyword: Posterior mode

Search Result 55, Processing Time 0.032 seconds

Relation of Left Atrial Wall Pathology to Atrial Fibrillation and Left Atrial Dimension in Mitral Valvular Diseases. (승모판질환에서 좌심방벽 생검소견과 심방세동 및 좌심방 크기의 관계)

  • 김광호
    • Journal of Chest Surgery
    • /
    • v.21 no.1
    • /
    • pp.1-9
    • /
    • 1988
  • The left atrial [LA] dimension and atrial fibrillation [AF] in patients with mitral valvular heart diseases have been thought to be related to hemodynamic burden to the LA depending on severity of stenosis or regurgitation of mitral valve, left ventricular contractility and the heart conditions. If hemodynamic burden persists long, it can affect the LA wall and structural change of the LA wall itself can developed. So the structural change of the LA wall could be thought to be related to the LA dimension and AF. To verify this relation, the LA wall biopsy was performed in 26 patients with rheumatic mitral valvular heart disease at the left atriotomy incision margin which was posterior to the interatrial groove after completion of surgery to the mitral valve such as valve replacement or commissurotomy. Relation of the pathological state of the LA wall to AF and the LA dimension measured by M-mode echocardiography was studied. The conclusions were as follow. 1. There was tendency that degree of fibrosis of myocardium of the LA wall was related to the LA dimension. 2. There was more chance that patients who had severe fibrosis of myocardium of the LA wall had pre and postoperative AF. 3. There was no relation between reduction rate of the LA dimension before and after surgery and degree of fibrosis of myocardium of the LA wall.

  • PDF

Medial Partial Arytenoidectomy by $CO_2$laser for Bilateral Vocal Cord Paralysis (양측 성대마비 환자에 대한 $CO_2$레이저 피열연골 내측부분절제술)

  • 최홍식;최영준;이용훈;박헌이
    • Korean Journal of Bronchoesophagology
    • /
    • v.4 no.2
    • /
    • pp.219-224
    • /
    • 1998
  • Bilateral vocal cord paralysis can result in severe airway compromise. Over the years a variety of arytenoidectomy procedures have bee described, and one or more of these have been the gold standard for many years. A widely accepted treatment is endoscopic laser total arytenoidectomy. However, vocal results are usually poor. Objective : To evaluate the effect of treatment of endoscopic laser medial partial arytenoidectorny for bilateral vocal cord paralysis Material and Methods : We performed endoscopic medial partial arytenoidceomy with $CO_2$laser for 3 patients with bilateral vocal cord paralysis. The $CO_2$laser is operated with a continuous 7-watt beam in superpulse mode. We compared degree of dyspnea and glottic area of pre-operation with those of post-operation for 3 patients. We analysed aerodynamic study pre-operatively and post-operatively for 1 patient. Results The symptom of dyspnea was improved markedly and the glottic area was widened from 34% to 50% compared with that of pre-operation. The voice quality was slightly decreased. Tracheotomy was not necessary for not-tracheotomized patient and decanulation was possible for tracheotomized patient post-operatively. Cunclusion: The endoscopic laser medial partial arytenoidectomy is a convient and effective method for opening the posterior glottic airway.

  • PDF

The Study on Usefulness of LEAP Collimator in Lung Ventilation SPECT (Lung Ventilation SPECT에서 LEAP Collimator의 유용성에 관한 연구)

  • Kim, Jung Soo;Kim, Soo Mee;Kim, Jin Eui;Lee, Jae Sung;Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.18-24
    • /
    • 2012
  • Purpose : Although lung ventilation SPECT (LV-SPECT) has a good sensitivity in detection of deep lung lesions, it is difficult to apply the LV-SPECT to patients having breathing problems due to limited examination time. In this study, we evaluated the usefulness of LEAP collimator, which provides high detection sensitivity and tolerable resolution, for the LV-SPECT in terms of diagnostic accuracy and examination time. Materials and Methods : Four volunteers inhaled Technegas (370 MBq) and the lung ventilation planar scan (LVPS, 300 counts/view (cpv)) with LEHR collimator was performed using Siemens E.cam scanner as a reference test. LV-SPECT scans were performed with three collimators, LEHR, LEUHR, and LEAP, in low (7 kcpv) and high (70 kcpv) counting modes. The count ratios of left (LT) and right (RT) lung segments were calculated on the geometric mean view of anterior and posterior images for LVPS and on the summed coronal images of LV-SPECT, respectively. Comparing to LVPS, the usefulness of three different collimators for LV-SPECT was evaluated through statistical analysis (paired t-test), on count ratios of lung segments. Results : The average LT:RT ratio in LVPS was 47:53. For LV-SPECT, there were negligible difference of the LT:RT ratios (48:52 on average) among three different collimators in low and high counting modes. Comparing to standard LVPS with LEHR, all LV-SPECTs with different collimators resulted in similar diagnostic accuracy through paired t-test (p>0.05). The scan time in LVPS (6 views) was 17.3 min. For LV-SPECT (128 views) in low counting mode, it took 18.7 (LEUHR), 15.0 (LEHR), and 12.3 min (LEAP), respectively. Conclusion : Comparing to standard LVPS, the LV-SPECT with LEAP in low counting mode provided the comparable diagnostic accuracy in addition to shortened scan time.

  • PDF

THE EFFECT OF TEMPERATURE CHANGES ON THE PHYSICAL PROPERTIES OF POSTERIOR COMPOSITE RESINS (구치부용 복합 레진 가열시 물리적 성질의 변화에 관한 실험적 연구)

  • Park, Yeon-Hong;Min, Byung-Soon;Choi, Ho-Young;Park, Sung-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.14 no.1
    • /
    • pp.41-56
    • /
    • 1989
  • The purpose of this study was to examine the effect of temperature dependence of the behavior on the physical properties of posterior composite resins. Three light cure posterior composite resins (Heliomolar, Litefil-P, and P-50) and one chemical cure posterior composite resin (Bisfil-II) were used as experimental materials. Composite resin was placed in a cylindrical brass mold (2.5 mm high and 6.5 mm inside diameter) that was rested on a glass plate. Another flat glass was placed on top of the mold, and the plate was tightly clamped together. After the mold had been filled with the light cure composite material, the top surface was cured for 30 seconds with a light source. Chemical cure resin specimens were made in the same manner as above. Three hundreds and twenty composite resin specimens were constructed from the four composite materials. One hundred and sixty specimens of them were placed in a heater at $50^{\circ}C$, $75^{\circ}C$, $100^{\circ}C$, $125^{\circ}C$, $150^{\circ}C$, $175^{\circ}C$ and $200^{\circ}C$ for 5 minutes or 10 minutes respectively before compressive strengths were measured. Another one hundred and sixty specimens were tested for the diametral tensile strengths in the same way as above. They were randomly divided into eight groups according to the mode of heating methods as follows and stored in distilled water at $37^{\circ}C$ for 24 hours. Group $37^{\circ}C$ - specimens were stored at $37^{\circ}C$ in distilled water for 24 hours. Group $50^{\circ}C$ - specimens were heated at $50^{\circ}C$ after curing. Group $75^{\circ}C$ - specimens were heated at $75^{\circ}C$ after curing. Group $100^{\circ}C$ - specimens were heated at $100^{\circ}C$ after curing. Group $125^{\circ}C$ - specimens were heated at $125^{\circ}C$ after curing. Group $150^{\circ}C$ - specimens were heated at $150^{\circ}C$ after curing. Group $175^{\circ}C$ - specimens were heated at $175^{\circ}C$ after curing. Group $200^{\circ}C$ - specimens were heated at $200^{\circ}C$ after curing. Twenty specimens of each of four composite resins were respectively made by insertion of materials into same mold for examining the dimensional changes between before and after heating. The final eighty specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before testing the dimensional changes. Compressive and diametral tensile strengths were measured crosshead speed 1mm/minute and 500Kg in full scale with a mechanical testing machine (DLC 500 Type, Shimadzu Co., Japan). Dimensional changes were determined by measuring the diametral changes of eighty specimens with micrometer (Mitutoyo Co., Japan). Results were as follows: 1. Diametral tensile strengths of specimens in all groups were increased with time heated compared with control group except for that in group $50^{\circ}C$ and the maximum diametral tensile strength was appeared in the specimen of Litefil-P heated for 10 minutes at $100^{\circ}C$. In heliomolar and P-50, it could be seen in the specimen heated for 10 minutes at $150^{\circ}C$, but in Bisfil-II, it could be found in the specimen heated for 5 minutes at $150^{\circ}C$. 2. Compressive strengths of specimens in all groups was tended to be also increased with time heated but that in group $50^{\circ}C$ and the maximum compressive strengths were showed in the same specimens conditioned as the diametral tensile strengths of four composite materials tested. 3. In Heliomolar, Litefil-P, and Bisfil-II, it was decreased in diameters of resin specimens between before heating and increased in diameters of resin specimens after storing in distilled water, but it was not in P-50. 4. There is little difference in diametral tensile strengths, compressive strengths, and dimensional changes followed by heating the resin specimens for 5 minutes and 10 minutes, but there is no statistical significances.

  • PDF

FINITE ELEMENT ANALYSIS OF MANDIBULAR STRESSES INDUCED BY OVERDENTURE WITH DIFFERENT DESIGNS OF ABUTMENT COPINGS (지대치 coping형태에 따른 overdenture하에서 하악 응력에 관한 유한요소법적 분석)

  • Park Hae-Kyoon;Chung Chae-Heon;Cho Kyu-Zong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.3
    • /
    • pp.141-170
    • /
    • 1991
  • This study was to analyze the displacement and the magnitude and mode of distribution of the stresses in the lower overdenture, the mucous membrane, the abutment teeth and the mandibular supporting bone when various abutment designs were subjected to different loading schemes. For this study, the two-dimensional finite element method was used. The models of overdenture and mandibe with the canine and the second premolar remaining, were fabricated. In the first design, a 1 mm space was prepared between the denture and the dome abutment with the height of 2 mm(OS). In the second design, a contact between the denture and the occlusal third of the dome abutment with the hight of 2 mm was prepared(OC). In the third design, a 0.5 mm space was prepared between the denture and 8 degree tapered cylindrical abutments with the height of 7 mm(TS). In the fourth design, a contact between the denture and the occlusal two thirds of the conical abutments with the height of 7 mm was prepared(TC). In order to represent the same physiological condition as the fixed areas of the mandible under loading schemes, the eight nodes which lie at the mandibular angle, the coronoid process and the mandibular condyle were assumed to be fixed. Each model was loaded with a magnitude of 10 Kgs on the first molar region (P1) and 7 Kgs on the central incisor region (P2) in a vertical direction. The force of 10 Kgs was then applied distributively from the first premolar to the second molar of each motel in a vertical direction (P3). The results were as follows: 1. The vertical load on the central incisor region(P2) produced the higher displacement and stress concentration than that on the posterior region(P1, P3). 2. The case of space between abutment and denture base produced higher displacement than that of contact, and the case of long abutment produced higher displacement than that of short abutment because of low rigidity of denture base. 3. The magnitude of the torque and vertical force to the abutment teeth and the stress distribution to the denture base was higher in the telescope coping than in the overdenture coping. 4. The vertical load on the central incisor region(P2) produced higher equivalent stress in the mandible than that on the posterior region(P1, P3). 5. The case of space between abutment and denture base produced better stress distribution to the farther abutment from the loading point than that of contact. 6. In case of sound abutment teeth, the type of telescope coping can be used, hilt in case of weak abutment, the type of overdenture coping is considered to be favorable generally.

  • PDF

STUDY OF THE TENSILE BOND STRENGTH OF COMPOSITES RESINS APPLIED TO ACID-ECHED ENAMEL (산처리(酸處理)된 Enamel표면(表面)에 대(對)한 Composite resin의 인장접착강도(引張接着强度)에 관(關)한 연구(硏究))

  • Lee, Young-Kun;Min, Byung-Soon;Choi, Ho-Young;Park, Sung-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.12 no.2
    • /
    • pp.45-53
    • /
    • 1987
  • The purpose of this study was to evaluate the tensile bond strength between composite resin and the human enamel. Three composite resin systems, two chemical (Clearfil Posterior, and Clearfil Posterior-3) and one light cure (Photo Clearfil-A), used with and without an intermediate resin (clearfil bonding agent), were evaluated under different amounts of load (10g, 200g and 200g for a moment) for in vitro tensile bond strength to acid-eched human enamel. Clinically intact buccal or lingual surfaces of 144 freshly extracted human permanent molars, embedded in acrylic were flattened with No #600 carborundum discs. Samples were randomly assigned to the different materials and treatments using a table of random numbers. Eight samples were thus prepared for each group(Table 2) these surfaces were etched with an acid etchant (Kurarey Co. Japan) in a mode of etching for 30 seconds, washing for 15 seconds, and drying for 30-seconds. During the polymerization of composite resin on the acid-etched enamel surfaces with and without bonding agent 10-gram, 200 gram and temporary 200 gram of load were applied. The specimens were stored in 50% relation humidity at $37^{\circ}C$ for 24 hours before testing. An universal Testing machine (Intesco model No. 2010, Tokyo, Japan) was used to apply tensile loads in the vertical directed (fig 5), and the force required for separation was recorded with a cross head speed of 0.25 mm/min and 20 kg in full scale. The results were as follow: 1. The tensile bond strength was much greater in applying a bonding agent than in not doing that. 2. The tensile bond strength of chemical cure composite resin was higher than that of light cure composite resin with applying on bonding agent on the acid-etched enamel. 3. In case of not applying a bonding agents on the acid-etching enamel, the highest tensile bond strength under 200 gram of load was measured in light cure composite resin. 4. The tensile bond strength under 200-gram of load has no relation with applying the bonding agent. 5. Under the load of 10-gram, There was significant difference in tensile bond strength as applying the bonding agent.

  • PDF

ACCURACY OF IMPROVED STONE CASTS FROM ELASTOMERIC IMPRESSION MATERIALS (탄성고무인상재에 따른 초경석고 모형의 정밀도에 관한 연구)

  • Kim, Kee-Hong;Chang, Ik-Tae;Yim, Soon-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.3
    • /
    • pp.301-312
    • /
    • 1999
  • The purpose of this study was to compare the accuracy of currently used elastomeric impression materials for complete arch impression taking. Five elastomers (Impregum, Permlastic, Express, Extrude, Examix) and one Irreversible hydrocolloid (Aroma-fine) were tested. For each material, 5 impressions were made of stainless steel model to which five tapered posts were attached. Custom trays were used for polyether and polysulfide impression materials, and putty/wash two step technique was used for addition polyvinylsiloxane impression materials. Improved stone mod els were poured to all impressions. Accuracy of the materials was assessed by measuring ten distances on stone dies poured from impressions of the master model. All measurements for master and improved stone models were made with three dimensional measuring machine. The results were as follows 1. The dimensional accuracy of polyether, extrude, and examix were significantly superior to poly-sulfide, exress, and alginate in reproducing full arch mode (p<0.05) 2. There were no statistical differences in dimensional accuracy for full arch impression between polyether extrude and examix (p>0.05). 3. there were no statistical differences in dimensional accuracy between polysulfide, express, and alginate(p>0.05). 4. There were no statistical differences between addition polyvinyl siloxane materials (p>0.05) 5. There were no statistical differences between anterior-posterior and lateral dimensional changes of all impression materials (p>0.05).

  • PDF

CASE REPORT OF AMELOGENESIS IMPERFECTA (법랑질형성부전증에 대한 증례보고)

  • Baik, Byeoung-Ju;Kim, Sang-Hoon;Lee, Seung-Ik;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.4
    • /
    • pp.499-504
    • /
    • 2000
  • Amelogenesis imperfecta is defined as a genetically determined effect affecting enamel formation and may be associated with other ectodermal or systemic disorders. It is entirely an ectodermal disturbance, since the mesodermal components of the teeth are basically normal. The presentation of diverse clinical manifestations in 1:14,000 to 1:16,000. Classification of the AI types considers mode of inheritance and clinical manifestations. The most widely accepted classification system recognize three major groups; i.e., hypoplastic(thin enamel), hypocalcified(primary mineralization defect), hypomaturation(defect in enamel maturation). The treatment is that at first, genetic counselling must be practiced, and in anterior teeth, composite resin veneer or jacket crown for esthetics, and in posterior teeth, stainlees steel crown or gold onlay.

  • PDF

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF MANDIBULAR STRESSES UNDER COMPLETE DENTURES WITH VARIANT ARTIFICIAL TEETH FORMS AND OCCLUSAL PATTERNS (총의치 교합면 형태가 하악골 응력 분포에 미치는 영향에 관한 삼차원 유한요소분석적 연구)

  • Lee Cheol-Gyu;Kim Chang-Whe;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.3
    • /
    • pp.351-384
    • /
    • 1993
  • Complete denture occlusion must be developed to function efficiently and with the least amount of trauma to the supporting tissues. For the preservation of supporting tissues, it is imperative to reduce to a minimum the functional stress induced by dentures. The magnitude of the horizontal component of functional stress contributed by various occlusal teeth forms has not been studied. This study was aimed to investigate the influence of different occlusal teeth forms on the mode of distribution of the stresses in the mandibular tissue, and the displacement of lower dentures during the variant functional movement of mandible for this study three dimensional finite element analysis was used. FEM models were created using commercial software Super Sap for IBM 32 bit computer. The model was composed of 3380 brick elements and 4346 nodes. The results were as follows. 1. The magnitude of stress was similar between two models in centric occlusion, in the case of anatomic model, the stress was concentrated on the buccal side of alveolar ridge beneath the bicuspids. 2. During the protrusive movement, the increasing of stress from the posterior to anterior part of mandible was seen in the case of anatomic model. 3. During the lateral movement, the stress of anatomic model was greater than that of nonanatomic model. 4. The stress of anatomic model was concentrated on the anterior region of residual ridge during the lateral movement. 5. In the case of anatomic model the anterior part of denture was displaced severely at the centric and lateral position, but the denture of nonanatomic model was displaced minutely at the protrusive and lateral position.

  • PDF

Comparison of the Effects of Sling Exercise and Total Body Resistance Exercise on Physical Functional Performance and Postural Balance : A preliminary study

  • Han-Kyu Park;Byoung-Ha Hwang
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.2
    • /
    • pp.11-23
    • /
    • 2024
  • Purpose : The purpose of this study was to investigate the effect of exercise using a suspension device (sling and total body resistance exercise; TRX) on physical functional performance and postural balance. Methods : An experimental study comparing 2 different suspension exercise was conducted on 16 healthy college students. 16 subjects were assigned to two groups. They were classified into 8 sling group and 8 TRX group. Miniplus was used to evaluate physical functional performance. In this study, isokinetic resistance mode was used to compare and analyze seven movement patterns. Biorescue was used to evaluate postural balance. The intervention exercises in this study are as follows. Standing lean forward (SLF) using a sling and TRX was performed 3 times a week for 3 weeks. The SLF was held for 10 seconds and then rested for 15 seconds, repeated a total of 10 times for 3 sets. Results : In the TRX group, significant increases were observed in physical functional performance (p<.05). Among the differences between groups, significant differences were confirmed on the front of the right arm, the back of the left arm, and the back of the right arm. In the sling group, significant increases were observed in left, right, front, and overall dynamic balance (p<.05). A significant increase in posterior dynamic balance was confirmed in the TRX group (p<.05). There was no significant difference between groups. Conclusion : Based on the results of this study, TRX was effective in improving physical functional performance, while the sling was effective in enhancing postural balance. However, confirming the effectiveness of slings and TRX in the relationship between physical functional performance and postural balance proved inadequate. Therefore, additional research should be conducted to verify the effects of suspension.