• Title/Summary/Keyword: Posterior mode

Search Result 55, Processing Time 0.034 seconds

Impact Analysis of the Cervical Spin using a Finite Element Model (유한요소 모델을 이용한 충격력에 따른 경추부의 응답특성 해석)

  • 김영은;박덕용;이춘기
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.5
    • /
    • pp.249-257
    • /
    • 1999
  • A three dimensional finite model of a human neck has been developed in an effort to study the mechanics of cervical spin while subjected to vertical impact. This model consisting of the vertebrae from C1 through C7 including posterior element and ligaments was constructed by 2mm thick transverse CT cross-sections and X-ray film taken at lateral side. Geometrical nonlinearity was also considered for the large deformation on the disc. ABAQUS package was used for calculation and its results were verified comparing with responses of a model under static loading condition with published in-vitro experimental data. There were more cervical fracture in the restrained (compression) mode than in the nonrestrained (flexion-compression and extension-compression) mode. Upper cervical(C1-C2) injuries were observed under compression-extension modes, while lower cervical injuries occurred undjer compression-flexion modes. Posterior ligament distraction without bony damage at the upper cervical spin(C1-C2) were observed secondary to C5-C7 trauma in compression-flexion modes.

  • PDF

Complex Segregation Analysis of Total Milk Yield in Churra Dairy Ewes

  • Ilahi, Houcine;Othmane, M. Houcine
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.24 no.3
    • /
    • pp.330-335
    • /
    • 2011
  • The mode of inheritance of total milk yield and its genetic parameters were investigated in Churra dairy sheep through segregation analyses using a Monte Carlo Markov Chains (MCMC) method. Data which consisted of 7,126 lactations belonging to 5,154 ewes were collected between 1999 and 2002 from 15 Spanish Churra dairy flocks. A postulated major gene was assumed to be additive and priors used for variance components were uniform. Based on 50 000 Gibbs samples from ten replicates chains of 100,000 cycles, the estimated marginal posterior means${\pm}$posterior standard deviations of variance components of milk yield were $23.17{\pm}18.42$, $65.20{\pm}25.05$, $120.40{\pm}42.12$ and $420.83{\pm}40.26$ for major gene variance ($\sigma_G^2$), polygenic variance ($\sigma_u^2$), permanent environmental variance ($\sigma_{pe}^2$) and error variance ($\sigma_e^2$), respectively. The results of this study showed the postulated major locus was not significant, and the 95% highest posterior density regions ($HPDs_{95%}$) of most major gene parameters included 0, and particularly for the major gene variance. The estimated transmission probabilities for the 95% highest posterior density regions ($HPDs_{95%}$) were overlapped. These results indicated that segregation of a major gene was unlikely and that the mode of inheritance of total milk yield in Churra dairy sheep is purely polygenic. Based on 50,000 Gibbs samples from ten replicates chains of 100,000 cycles, the estimated polygenic heritability and repeatability were $h^2=0.20{\pm}0.05$ and r=$0.34{\pm}0.06$, respectively.

The Abnormality of Posterior Default Mode Network in Medication-Naïve Attention-Deficit Hyperactivity Disorder Children : Resting State fMRI Study (약물 복용력이 없는 주의력결핍 과잉행동장애 아동에서의 뒤쪽 내정상태회로 이상 : 휴식상태 기능적 뇌자기공명영상 연구)

  • Choi, Jee-Wook;Go, Hyo-Jin;Woo, Young-Sup;Song, Seung-Hoon;Yang, Po-Song;Jeong, Bum-Seok
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.23 no.2
    • /
    • pp.57-62
    • /
    • 2012
  • Objectives : Characteristic symptoms, including hyperactivity and easy distractibility, in children with attention-deficit hyperactivity disorder (ADHD) suggest that their brain status, even at rest, might differ from that of healthy children. This study was conducted in order to determine whether resting state brain activity is compromised in medication-naive children with ADHD. Methods : Twenty medication-naive children with ADHD (mean age $10.3{\pm}2.5$) and 28 age- and gender-matched healthy volunteers (mean age $10.3{\pm}2.0$) underwent measurements for resting state brain activity using functional magnetic resonance imaging (fMRI). Among resting state related-independent components (RSICs) extracted from fMRI data using independent component analysis, a significant difference in RSICs was observed between groups, using a mixed Gaussian/gamma model. Results : Except for IQ, which was higher in the healthy control group, no demographic difference was observed between the two groups (p<.001). Significantly less activation of one RSIC, which includes the bilateral precuneus/posterior cingulate cortex, occipito-temporal junction, and anterior cingulate cortex, was observed in the ADHD group, compared with the control group (p<.05). Conclusion : An abnormal RSIC, posterior default mode network (DMN), was observed in the medication-naive ADHD group. Results of our study suggest that abnormality of posterior DMN is one of the main pathophysiologies of ADHD.

Markov Chain Monte Carlo simulation based Bayesian updating of model parameters and their uncertainties

  • Sengupta, Partha;Chakraborty, Subrata
    • Structural Engineering and Mechanics
    • /
    • v.81 no.1
    • /
    • pp.103-115
    • /
    • 2022
  • The prediction error variances for frequencies are usually considered as unknown in the Bayesian system identification process. However, the error variances for mode shapes are taken as known to reduce the dimension of an identification problem. The present study attempts to explore the effectiveness of Bayesian approach of model parameters updating using Markov Chain Monte Carlo (MCMC) technique considering the prediction error variances for both the frequencies and mode shapes. To remove the ergodicity of Markov Chain, the posterior distribution is obtained by Gaussian Random walk over the proposal distribution. The prior distributions of prediction error variances of modal evidences are implemented through inverse gamma distribution to assess the effectiveness of estimation of posterior values of model parameters. The issue of incomplete data that makes the problem ill-conditioned and the associated singularity problem is prudently dealt in by adopting a regularization technique. The proposed approach is demonstrated numerically by considering an eight-storey frame model with both complete and incomplete modal data sets. Further, to study the effectiveness of the proposed approach, a comparative study with regard to accuracy and computational efficacy of the proposed approach is made with the Sequential Monte Carlo approach of model parameter updating.

Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography (전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가)

  • Kim, Jeong Jin;Jang, Seong Won;Park, Jang Heum;Lee, Kwan Seob;Ha, Dong Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.23-31
    • /
    • 2012
  • There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.

  • PDF

Mode identifiability of a cable-stayed bridge based on a Bayesian method

  • Zhang, Feng-Liang;Ni, Yi-Qing;Ni, Yan-Chun
    • Smart Structures and Systems
    • /
    • v.17 no.3
    • /
    • pp.471-489
    • /
    • 2016
  • Modal identification based on ambient vibration data has attracted extensive attention in the past few decades. Since the excitation for ambient vibration tests is mainly from the environmental effects such as wind and traffic loading and no artificial excitation is applied, the signal to noise (s/n) ratio of the data acquired plays an important role in mode identifiability. Under ambient vibration conditions, certain modes may not be identifiable due to a low s/n ratio. This paper presents a study on the mode identifiability of an instrumented cable-stayed bridge with the use of acceleration response data measured by a long-term structural health monitoring system. A recently developed fast Bayesian FFT method is utilized to perform output-only modal identification. In addition to identifying the most probable values (MPVs) of modal parameters, the associated posterior uncertainties can be obtained by this method. Likewise, the power spectral density of modal force can be identified, and thus it is possible to obtain the modal s/n ratio. This provides an efficient way to investigate the mode identifiability. Three groups of data are utilized in this study: the first one is 10 data sets including six collected under normal wind conditions and four collected during typhoons; the second one is three data sets with wind speeds of about 7.5 m/s; and the third one is some blind data. The first two groups of data are used to perform ambient modal identification and help to estimate a critical value of the s/n ratio above which the deficient mode is identifiable, while the third group of data is used to perform verification. A couple of fundamental modes are identified, including the ones in the vertical and transverse directions respectively and coupled in both directions. The uncertainty and s/n ratio of the deficient mode are investigated and discussed. A critical value of the modal s/n ratio is suggested to evaluate the mode identifiability of the deficient mode. The work presented in this paper could provide a base for the vibration-based condition assessment in future.

A Biomechanical Comparison among Three Surgical Methods in Bilateral Subaxial Cervical Facet Dislocation

  • Byun, Jae-Sung;Kim, Sung-Min;Choi, Sun-Kil;Lim, T. Jesse;Kim, Daniel H.
    • Journal of Korean Neurosurgical Society
    • /
    • v.37 no.2
    • /
    • pp.89-95
    • /
    • 2005
  • Objective: The biomechanical stabilities between the anterior plate fixation after anterior discectomy and fusion (ACDFP) and the posterior transpedicular fixation after ACDF(ACDFTP) have not been compared using human cadaver in bilateral cervical facet dislocation. The purpose of this study is to compare the stability of ACDFP, a posterior wiring procedure after ACDFP(ACDFPW), and ACDFTP for treatment of bilateral cervical facet dislocation. Methods: Ten human spines (C3-T1) were tested in the following sequence: the intact state, after ACDFP(Group 1), ACDFPW(Group 2), and ACDFTP(Group 3). Intervertebral motions were measured by a video-based motion capture system. The range of motion(ROM) and neutral zone(NZ) were compared for each loading mode to a maximum of 2.0Nm. Results: ROMs for Group 1 were below that of the intact spine in all loading modes, with statistical significance in flexion and extension, but NZs were decreased in flexion and extension and slightly increased in bending and axial rotation without significances. Group 2 produced additional stability in axial rotation of ROM and in flexion of NZ than Group 1 with significance. Group 3 provided better stability than Group 1 in bending and axial rotation, and better stability than Group 2 in bending of both ROM and NZ. There was no significant difference in extension modes for the three Groups. Conclusion: ACDFTP(Group 3) demonstrates the most effective stabilization followed by ACDFPW(Group 2), and ACDFP(Group 1). ACDFP provides sufficient strength in most loading modes, ACDFP can provide an effective stabilization for bilateral cervical facet dislocation with a brace.

Echocardiographic Findings after Mitral Valve Replacement (승모판막치환수술 전후 심장초음파 소견의 변화에 관한 연구)

  • 이상진
    • Journal of Chest Surgery
    • /
    • v.27 no.8
    • /
    • pp.656-663
    • /
    • 1994
  • Evaluation of heart function is of importance in assessing the results of valvular heart surgery. Information on volume and functional change of heart chamber can be obtained by cardiac catheterization and echocardiography. We studied 41 patients with mitral stenosis[MS] and 23 patients with mitral regurgitation[MR] using M-mode echocardiography before and after mitral valve replacement[MVR] at Pusan Paik Hospital. Preoperative cardiac catheterization was available in 56 cases, and the results were obtained as follows. 1. In patients with MS, preoperative average LV end-diastolic dimension[EDD] and end-systolic dimension[ESD] were remained within normal range, but postoperative EDD and ESD were significantly decreased[P<0.01]. The preoperative and postoperative LV ejection fraction[EF] were remained within the normal range and no significant change[P>0.05]. The preoperative left atrial dimension[LAD] was enlarged considerably above normal[P<0.01], but was significantly decreased after surgery[P<0.001]. The preoperative LV posterior wall thickness[PWTh] was within normal range, and no significant change after surgery[P>0.05]. 2. In patients with MR, preoperative average end-diastolic dimension[EDD] and end-systolic dimension[ESD] were significantly greater than normal[P<005], but postoperative EDD and ESD were significantly decreased[P<0.01]. The preoperative LV ejection fraction[EF] and fractional shortening[FS] were within normal range, and no significant change after surgery[P>0.05].The preoperative left atrial dimension[LAD] was enlarged considerably above normal [P<0.01], but was significantly decreased after surgery[P<0.001].The preoperative LV posterior wall thickness[PWTh] was within normal range, and no significant change after surgery[P>0.05].

  • PDF

Posterior Cerebral Artery Aneurysm : Surgical Result of 11 Patients

  • Ko, Che-Kyu;Shin, Il-Young;Ahn, Jae-Sung;Kwon, Yang;Kwun, Byung-Duk;Lee, Jung-Kyo
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.3
    • /
    • pp.192-197
    • /
    • 2006
  • Objective : Eleven patients treated with posterior cerebral artery[PCA] aneurysm during 6.3-years period are retrospectively reviewed to determine treatment outcome. Methods : Eleven patients with PCA aneurysm were treated from January 1998 to May 2004. Their medical records and radiologic studies were reviewed retrospectively. The records of these patients were analysed with particular reference to their demographic details, mode of presentation, and treatment outcome. Results : Of the 11 patients, 8 patients presented with symptoms related aneurysmal bleeding. Three patients had unruptured PCA aneurysms. Open or endovascular surgery was performed in 9 patients; None of these patients exhibited a third nerve palsy, visual field deficit, or hemiparesis at the time of presentation. Postoperatively, 2 made a good recovery, 2 had a moderate disability because of cerebral infarction after surgery, and 5 had a severe disability because of cerebral infarction after surgery. Of 2 conservatively treated patients, 1 was doing well but the other died as a result of brain swelling. Conclusion : The treatment of the PCA aneurysms is difficult regardless of the aneurysmal size, site, and treatment modality. All reasonable treatment to reduce the risk of associated morbidity should be considered.

FRACTURE STRENGTH BETWEEN DIFFERENT CONNECTOR DESIGNS OF ZIRCONIA CORE FOR POSTERIOR FIXED PARTIAL DENTURES MANUFACTURED WITH CAD/CAM SYSTEM (CAD/CAM을 이용한 구치부 전부도재 고정성 국소의치 지르코니아 코어의 연결부 설계에 따른 파절강도)

  • Seo Jun-Yong;Park In-Nim;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.29-39
    • /
    • 2006
  • Statements of problem: Zirconia core is used for posterior fixed partial dentures because it's good mechanical properties. Stress is concentrated on connectors in fixed partial dentures, so the proper design of connector areas is needed for adequate mechanical long-term properties of any prosthesis. The area of connector is critical, but tooth size and surrounding soft tissue limit the connector design. Purpose: The purpose of this study is to compare fracture strengths between different connector designs of zirconia core for posterior fixed partial dentures manufactured with CAD/CAM system and determining the optimal connector design satisfying strength and hygiene. Material and method: The following four groups of 40 posterior fixed partial denture specimens(each group 10) were fabricated as followed; group 1 vertical height of connector is 3mm (control group, all groups have the same condition); group 2, lingual vertical 1mm reinforcement on connector; group 3, lingual vertical 2mm reinforcing on connector and group 4, lingual vertical 3mm reinforcing on connector. Specimens were subjected to compressive loading on the central fossa of pontic by instron. SEM was used to identify the initial crack and characterize the fracture mode. Results: The results were as follows: 1. The mean fracture load of the non-lingual reinforcing group was 1212N and the lingual vertical 1mm reinforcing group was 1510N, the lingual vertical 2mm reinforcing group was 1882N, the lingual vertical 3mm reinforcing group was 1980N. 2. The reinforcing groups were statistically significant compared to non-reinforcing groups(P<0.001). 3. There were 2, 3mm reinforcing groups that were statistically significant compared to 1mm reinforcing groups(P<0.001), and the 3mm reinforcing group was not statistically significant compared to 2mm reinforcing groups(P>0.05) 4. Fractures were initiated in gingival embrasures of connectors and processed to the loading site. Conclusion: In this study, lingual reinforcement of connector for improved strength of zirconia based fixed partial denture is nessasary. And long-term study for clinical application is required