• 제목/요약/키워드: Posterior fossa

검색결과 188건 처리시간 0.026초

두 개의 임플란트를 이용한 3본 고정성 국소의치에서 가공치 위치에 따른 하악골에서의 응력 분포 및 변형에 관한 삼차원 유한요소법적 연구 (THE THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF STRESS DISTRIBUTION AND DEFORMATION IN MANDIBLE ACCORDING TO THE POSITION OF PONTIC IN TWO IMPLANTS SUPPORTED THREE-UNIT FIXED PARTIAL DENTURE)

  • 김동수;김일규;장금수;박태환;김규남;손충렬
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제34권2호
    • /
    • pp.166-179
    • /
    • 2008
  • Excessive concentration of stress which is occurred in occlusion around the implant in case of the implant supported fixed partial denture has been known to be the main cause of the crestal bone destruction. Therefore, it is essential to evaluate the stress analysis on supporting tissue to get higher success rates of implant. The purpose of this study was to evaluate the effects of stress distribution and deformation in 3 different types of three-unit fixed partial denture sup-ported by two implants, using a three dimensional finite element analysis in a three dimensional model of a whole mandible. A mechanical model of an edentulous mandible was generated from 3D scan, assuming two implants were placed in the left premolars area. According to the position of pontic, the experiments groups were divided into three types. Type I had a pontic in the middle position between two implants, type II in the anterior posi-tion, and type III in the posterior position. A 100-N axial load was applied to sites such as the central fossa of anterior and posterior implant abutment, central fossa of pontic, the connector of pontic or the connector between two implants, the mandibular boundary conditions were modeled considering the real geometry of its four-masticatory muscular supporting system. The results obtained from this study were as follows; 1. The mandible deformed in a way that the condyles converged medially in all types under muscular actions. In comparison with types, the deformations in the type II and type III were greater by 2-2.5 times than in the type I regardless of the loading location. 2. The values of von Mises stresses in cortical and cancellous bone were relatively stable in all types, but slightly increased as the loading position was changed more posteriorly. 3. In comparison with type I, the values of von Mises stress in the implant increased by 73% in Type II and by 77% in Type III when the load was applied anterior and posterior respectively, but when the load was applied to the middle, the values were similar in all types. 4. When the load was applied to the centric fossa of pontic, the values of von Mises stress were nearly $30{\sim}35%$ higher in the type III than type I or II in the cortical and cancellous bone. Also, in the implant, the values of von Mises stress of the type II or III were $160{\sim}170%$ higher than in the type I. 5. When the load was applied to the centric fossa of implant abutment, the values of von Mises stress in the cortical and cancellous bone were relatively $20{\sim}25%$ higher in the type III than in the other types, but in the implant they were 40-45% higher in the type I or II than in the type III. According to the results of this study, musculature modeling is important to the finite element analysis for stress distribution and deformation as the muscular action causes stress concentration. And the type I model is the most stable from a view of biomechanics. Type II is also a clinically accept-able design when the implant is stiff sufficiently and mandibular deformation is considered. Considering the high values of von Mises stress in the cortical bone, type III is not thought as an useful design.

ORTHOPEDIC FORCE에 의한 백서악관절 주위조직의 변화에 대한 조직학적 연구 (A HISTOLOGICAL STUDY ON THE CHANCES OF THE SURROUNDING TISSUE IN MANDIBULAR JOINT BY THE ORTHOPEDIC FORCE IN RATS)

  • 이백민
    • 대한치과교정학회지
    • /
    • 제13권2호
    • /
    • pp.155-163
    • /
    • 1983
  • Many different appliances have been used to move teeth or to attempt to inhibit or stimulate growth of the jaws. Especially, Orthopedic force was used to apply a constant force on the mandible. Various orthopedic forces bring the changes of surrounding tissue, growth and development on the mandibular joint. Author carried out this study to find the histological changes of the mandibular joint in rats when the mandible applied posterior displacement. For the purpose of this study, $009\times036inch$ closed coil spring and 030inch orthopedic wire were used between the post occipital region and the chin region in order to render the orthopedic forces, posteriorly. The experimental animals vu. used 1 month old (GroupI), 3 months old (Group II), and 12 months old (Group III) rats. Following results were obtained; 1. At the beginning of the experimental Group I, there were predominant increment of Cartilage layer in the posterior parts of condylar head. Especially, the mature chondrocyte zone was increased. 2. In the experimental Group II, the chondroblastic zone was decreased while it showed slightly increased mature cartilage zone. 3. In the experimental Group III, the mature chondrocyte zone was disappeared gradually and there was a tendency to reduce the endochondral bone formation in condylar head. 4. After 30 days of experimental Group I and in experimental Group II, there was a tendency to decrease the immature cellular zone in the glenoid fossa by pressure. 5. There were no histological changes in the articular disc by pressure.

  • PDF

A Case of Lateral Medullary Infarction after Endovascular Trapping of the Vertebral Artery Dissecting Aneurysm

  • Cho, In-Yang;Hwang, Sung-Kyun
    • Journal of Korean Neurosurgical Society
    • /
    • 제51권3호
    • /
    • pp.160-163
    • /
    • 2012
  • We report an unusual case of lateral medullary infarction after successful embolization of the vertebral artery dissecting aneurysm (VADA). A 49-year-old man who had no noteworthy previous medical history was admitted to our hospital with a severe headache. Computed tomography (CT) revealed a subarachnoid hemorrhage, located in the basal cistern and posterior fossa. Cerebral angiography showed a VADA, that did not involve the origin of the posterior inferior cerebellar artery (PICA). We treated this aneurysm via endovascular trapping of the vertebral artery distal to the PICA. After operation, CT revealed post-hemorrhagic hydrocephalus, which we resolved with a permanent ventriculoperitoneal shunt procedure. Postoperatively, the patient experienced transient mild hoarsness and dysphagia. Magnetic resonance image (MRI) showed a small infarction in the right side of the medulla. The patient recovered well, though he still had some residual symptom of dysphagia at discharge. Such an event is uncommon but can be a major clinical concern. Further investigation to reveal risk factors and/or causative mechanisms for the medullary infarction after successful endovascular trapping of the VADA are sorely needed, to minimize such a complication.

Chiari 1.5 Malformation : An Advanced Form of Chiari I Malformation

  • Kim, In-Kyeong;Wang, Kyu-Chang;Kim, In-One;Cho, Byung-Kyu
    • Journal of Korean Neurosurgical Society
    • /
    • 제48권4호
    • /
    • pp.375-379
    • /
    • 2010
  • The Chiari 1.5 malformation is defined as a tonsillar hemiation within a Chiari I malformation with additional caudal descent of the brainstem through the foramen magnum. We describe a patient with Chiari I malformation who evolved to Chiari 1.5 malformation during longitudinal follow-up. A 15-year-old girl presented with neck pain during exercise for two years. She had been diagnosed with Chiari I malformation with mild hydrocephalus after minor cervical trauma at the age of six years. At that time, she was asymptomatic. After she complained of aggravated neck pain, neuroimaging (nine years after first imaging) revealed caudal descent of the brainstem and syringomyelia in addition to progression of tonsillar hemiation. Posterior fossa decompressive surgery resulted in complete resolution of neck pain. Based on neuroimaging and operative findings, she was diagnosed as Chiari 1.5 malformation. Neuroimaging performed seven months after surgery showed an increased anterior-posterior diameter of the medulla oblongata and markedly decreased syringomyelia. This case demonstrates progressive developmental process of the Chiari 1.5 malformation as an advanced form of the Chiari I malformation.

악관절기능장애자의 방사선학적 연구 (A RADIOGRAPHIC STUDY ON TEMPOROMANDIBULAR JOINT TROUBLE)

  • 최병운
    • 치과방사선
    • /
    • 제9권1호
    • /
    • pp.13-18
    • /
    • 1979
  • The purpose of this study was to investigate the radiographic images of Temporomandibular joint trouble patients. This study included 186 patients with the chief complaints of TMJ pain and dysfunction. Their age ranged from 17 to 68 years. All patients were identified in the department of Dental mary of College of Dentistry, Seoul National University, Apr. 1978 to Jun. 1979. The author has observed the radiographic variations of two positions of condylar head taken by modified transcranial oblique-lateral projection, which are one in centric occlusion and the other in 1 inch(2.54㎝) mouth open. The results were obtained as follows; 1. In centric occlusion, the distances and positional relationship between the summit of condylar head and the deepest point of articular fossa revealed more or less large variations; Normal range is of 37.9%, anterior displacement of 37.3% and posterior displacement of 22.6%. 2. In the horizontal movement of condylar heads when on 1 inch mouth open, it was revealed that normalrange was of 46.5%, anterior displacement of 12.3%, posterior displacement of 41. 1 %. 3. In the positional interrelationship of both condylar heads when on 1 inch mouth open, it was revealed that symmetry(71. 5%) occurred approximately 2.5 times as many as asymmetry. 4. In both centric occlusion and 1 inch mouth open, it was showed that almost all estimated figures were greater in male than in female, and in the horizontal movement of condylar head when on 1 inch open, it was showed that hypermobility was dominant in male and hypomobility in female.

  • PDF

Edema and hematoma after local anesthesia via posterior superior alveolar nerve block: a case report

  • Marques, Aline Louise Nascimento;Figueroba, Sidney R.;Mafra, Marco Antonio Tridapalli;Groppo, Francisco Carlos
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제22권3호
    • /
    • pp.227-231
    • /
    • 2022
  • Although rare, complications can occur with anesthetic procedures. The posterior superior alveolar nerve (PSAN) block anesthetic technique has a high success rate, but positive aspiration can cause bruising, transient diplopia, blurred vision, and temporary blindness in approximately 3% cases. When edema occurs, it is occasionally massive, especially in the infratemporal fossa, and the resulting hematoma is usually unsightly. A 20-year-old woman presented with massive edema followed by hematoma in the upper right jaw immediately after PSAN block administration, which subsequently spread to the oral mucosa. The patient did not report any complications during the anesthetic procedure. However, after the injection was administered, the patient experienced anesthetic sensations, which rapidly evolved to facial edema. There was mild pain, but without intraoral or extraoral bleeding. The patient was prescribed medicines and instructed to perform contrast therapy. Although hematomas and edema are rare, they are difficult to prevent. The choice of local anesthetic and appropriate application of the anesthetic technique can minimize their occurrence.

골내 임프란트를 이용한 고정성 국소의치 하에서 변위 및 응력에 관한 유한요소법적 분석 (FINITE ELEMENT ANALYSIS OF STRESSES AND DEFLECTIONS INDUCED BY FIXED PARTIAL DENTURE USING ENDOSTEAL IMPLANT)

  • 최수호;정재헌
    • 대한치과보철학회지
    • /
    • 제29권1호
    • /
    • pp.233-248
    • /
    • 1991
  • The purpose of this study was to qunatatively analyze the stress patterns induced in the abutment, superstructure, supporting bone and to determine the deflection of abutment and superstructure by appling occlusal force to natural teeth supported fixed prostheses and implant-supported fixed prostheses. The analysis has been conducted by using the two dimensional finite element method. The implant and natural tooth-supported bridge has a first molar pontic supported by mandibular second bicuspid and implant posterior retainer, which were rigidly(Model A) or flexible(Model B). The natural teeth-supported bridge has a first molar pontic supported by mandibular second bicuspid and second molar, which were rigidly splinted together(Model C). 63.5kg(Load P1) of localized load on central fossa of first molar pontic and 24kg(Load P2) of distributed load on each occlusal surface were applied respectively. 1. The coronal portion of premolar pontic and posterior abutment in fixed partial denture deflected inferiorly in order of Model B, Model C and Model A under Load P1 and Load P2. 2. Mesial displacement of the coronal portion of premolar showed in Model A, Model B and Model C under Load P1, but mesial displacement of that in Model B and distal displacement of that in Model A and Model C showed under Load P2. 3. Mesial displacement of the coronal portion of the pontic and distal displacement of the coronal portion of posterior abutment showed in Model A, Model B and Model C under Load P1 and Load P2. Displacement in the case of Model B was greater than that of Model A and Model C. 4. In the case Model A under Load P1 and Load P2, high stress apically was concentrated in the mesiocervical portion of the posterior abutment than in the disto-cervical portion of the premolar. 5. In the case of Model B under Load P1 and Load P2 high stress was concentrated in the case of the premolar than in that of posterior abutment and high stress especially was concentrated in the connected portion of pontic and posterior abutment. 6. In the case of Model C under Load P1 and Load P2, high stress was concentrated in the distal area of the cornal portion of premolar and the mesial area of the coronal portion of posterior abutment, and stress pattern was anteroposterially symmetric around the pontic. 7. Load P1 and Load P2 compared, stress magnitude was different but stress pattern was similar in Model A, Model B and Model C. 8. Under Load P1 and P2, stress magnitude in the mesial distal portion and the portion of root apex of the posterior abutment was in order of Model B, Model A and Model C.

  • PDF

구치부 반대교합의 조기치료에 대한 치험례 (EARLY TREATMENT OF THE POSTERIOR CROSS-BITE: A CASE REPORT)

  • 이은미;강동균;김태완;김영진;남순현;김현정
    • 대한소아치과학회지
    • /
    • 제35권2호
    • /
    • pp.357-366
    • /
    • 2008
  • 구치부 반대교합은 유치열기와 혼합치열기에서 종종 나타나는 부정교합으로서, 유병율은 $7{\sim}23%$로 다양하게 나타난다. 이는 상악 치아의 협측 교두가 대합되는 하악 치아의 협측 교두의 설측에 교합하는 상태이며, 하나의 치아 또는 한 치아군에서 나타날 수 있다. 구치부 반대교합의 경우, 보통 자발적 교정이 이루어지지 않으므로, 발견되는 즉시 치료해주는 것이 추천된다. 치성이나 기능성의 경우 성장함에 따라 골격성으로 이행하여 악골의 변형을 초래하고 교정적인 수단으로 개선이 불가능한 상태로 악화될 가능성도 있으므로 조기에 치료하는 것이 효과적이며, 이러한 반대교합의 치료 방법으로는 하악의 변위를 유발하는 조기접촉을 제거하기 위한 교합조정, 협소한 상악궁의 확장, 치열궁내 비대칭을 치료하기 위한 개개 치아의 배열 등의 방법이 있다. 본 증례에서는 유치열기와 초기 혼합치열기 아동에서 구치부 반대교합이 관찰되어 치아의 선택적 삭제와 상악궁의 확장으로 반대교합을 교정한 후 정기적 검진시 양호한 결과가 관찰되기에 이를 보고하는 바이다.

  • PDF

하악구치부 피질골 engagement가 임플란트 하중전달에 미치는 영향에 관한 3차원 유한요소법적 응력분석 (THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS OF THE EFFECT OF CORTICAL ENGAGEMENT ON IMPLANT LOAD TRANSFER IN POSTERIOR MANDIBLE)

  • 정창모
    • 대한치과보철학회지
    • /
    • 제37권5호
    • /
    • pp.607-619
    • /
    • 1999
  • Cortical support is an important factor, as the engagement of the fixture in strong compact bone offers an increased load-carrying capacity and initial stability. Because of the poor bone quality in the posterior mandible and other anatomic considerations, it has been suggested that implant fixtures be placed in these locations with apical engagement of the lingual cortical plate for so-called bicortication. The purpose of this investigation was to determine the effect of cortical engagements and in addition polyoxymethylene(POM) intramobile connector(IMC) of IMZ implant on implant load transfer in edentulous posterior segment of mandible, using three-dimensional (3D) finite element analysis models composed of cortical and trabecular bone involving single implant. Variables such as (1) the crestal peri-implant defect, (2) the apical engagement of lingual cortical plate, (3) the occlusal contact position (a vertical load at central fossa or buccal cusp tip), and (4) POM IMC were investigated. Stress patterns were compared and interfacial stresses along the bone-implant interface were monitored specially. Within the scope of this study, the following observations were made. 1) Offset load and angulation of fixture led to increase the local interfacial stresses. 2) Stresses were concentrated toward the cortical bones, but the crestal peri-implant defect increased the interfacial stresses in trabecular bone. 3) For the model with bicortication, it was noticed that the crestal cortical bone provided more resistance to the bending moment and the lingual cortical plate provided more support for the vertical load. But Angulation problem of the fixture from the lingual cortical engagement caused the local interfacial stress concentrations. 4) It was not clear that POM IMC had the effect on stress distribution under the present experimental conditions, especially for the cases of crestal peri-implant defect.

  • PDF

뒷목 근육통 증상을 보인 소뇌의 해면 혈관종 1예 (Cerebellar cavernous hemangioma that presented with posterior neck myalgia)

  • 백승아;윤경림;심계식;방재승
    • Clinical and Experimental Pediatrics
    • /
    • 제51권12호
    • /
    • pp.1363-1367
    • /
    • 2008
  • 해면 혈관종은 비교적 양성의 병변이며 다량의 뇌출혈을 일으키는 것은 드물어서 수술의 적응증에 대해 논란의 여지가 있다. 그러나 특히 소뇌 같은 후두와나 뇌간에서 발생한 해면 혈관종에서의 출혈은 제한된 공간으로 인해 비가역적인 뇌손상을 일으킬 수 있으며 이로 인해 사망한 경우도 보고되고 있어서 소뇌의 압박증상이 있으면 응급수술을 해야 한다. 병변으로부터 반복되는 출혈로 인해 뒷목 근육통으로 오인되었던, 소아에서는 드물게 소뇌에 생긴 해면 혈관종 1예를 보고하는 바이다.