• 제목/요약/키워드: Posterior fixation

검색결과 259건 처리시간 0.022초

Protrusive maxillomandibular fixation for intracapsular condylar fracture: a report of two cases

  • Jeong, Yeong Kon;Park, Won-Jong;Park, Il Kyung;Kim, Gi Tae;Choi, Eun Joo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제43권5호
    • /
    • pp.331-335
    • /
    • 2017
  • Clinical limitations following closed reduction of an intracapsular condylar fracture include a decrease in maximum mouth opening, reduced range of mandibular movements such as protrusion/lateral excursion, and reduced occlusal stability. Anteromedial and inferior displacement of the medial condyle fragment by traction of the lateral pterygoid muscle can induce bone overgrowth due to distraction osteogenesis between the medial and lateral condylar fragments, causing structural changes in the condyle. In addition, when conventional maxillomandibular fixation (MMF) is performed, persistent interdental contact sustains masticatory muscle hyperactivity, leading to a decreased vertical dimension and premature contact of the posterior teeth. To resolve the functional problems of conventional closed reduction, we designed a novel method for closed reduction through protrusive MMF for two weeks. Two patients diagnosed with intracapsular condylar fracture had favorable occlusion after protrusive MMF without premature contact of the posterior teeth. This particular method has two main advantages. First, in the protrusive position, the lateral condylar fragment is moved in the anterior-inferior direction closer to the medial fragment, minimizing bone formation between the two fragments and preventing structural changes. Second, in the protrusive position, posterior disclusion occurs, preventing masticatory muscle hyperactivity and the subsequent gradual decrease in ramus height.

A modified trans-anconeus approach to facilitate fixation of a posterior radial head fracture: a cadaveric feasibility study

  • Ahmed Mohamed Desouky;Ahmed Naeem Atiyya;Mohamed Elbishbishi;Marwa Mohamed El Sawy
    • Anatomy and Cell Biology
    • /
    • 제56권1호
    • /
    • pp.39-45
    • /
    • 2023
  • Fixation of radial head fracture with minimally invasive posterior approach remains a significant challenge. The aim of this study was to determine the feasibility of trans-anconeus posterior elbow approach and to observe lateral ulnar collateral ligament (LUCL) in extended elbows. This cadaveric study was performed in twenty upper limbs of fresh fixed adult male cadavers. An oblique incision was made in the middle segment of anconeus until the lateral ligament complex and the joint capsule had been revealed. A deep dissection was explored to observe the anatomical relationship of the LUCL to the anconeus. Measurements of the LUCL were recorded while the elbow was fully extended. The mean distance between the edge of the radial head and the proximal insertion of the LUCL was 13.3 mm (11.5-16.2 mm); the mean distance between the edge of the radial head and the distal insertion of the LUCL was 20.9 mm (19.2-23.4 mm); the distance between the edge of the radial head and the distal edge of the annular ligament was 11.2 mm (8.22-11.7 mm). By estimate correlation of the previous measurements, the direct and accessible way to expose the posterolateral articular capsule of the elbow joint was through a window in medial 2/3 of the middle segment of anconeus muscle. These trans-anconeus approach is useful. It provides good visualization, facilitates applying the implants, and lessens the risk of radial nerve injury. Awareness of the anatomy is mandatory to avoid injury of LUCL.

Management of Andersson Lesion in Ankylosing Spondylitis Using the Posterior-Only Approach: A Case Series of 18 Patients

  • Shaik, Ismail;Bhojraj, Shekhar Yeshwant;Prasad, Gautam;Nagad, Premik Bhupendra;Patel, Priyank Mangaldas;Kashikar, Aaditya Dattatreya;Kumar, Nishant
    • Asian Spine Journal
    • /
    • 제12권6호
    • /
    • pp.1017-1027
    • /
    • 2018
  • Study Design: This retrospective study was conducted including 18 patients who underwent posterior-only stabilization and fusion procedure for pseudoarthrosis in the ankylosed spine from October 2007 to May 2015. Purpose: This study aimed to describe the treatment outcomes in 18 patients with Andersson lesion (AL) who were managed using the posterior-only approach. Literature Review: AL is an unstable, localized, vertebral, or discovertebral lesion of the spine. It is observed in patients with ankylosing spondylitis. The exact etiology of this disorder remains unclear, and the treatment guidelines are not clearly described. Methods: We analyzed 18 patients with AL who were treated with posterior long segment spinal fusion without any anterior interbody grafting or posterior osteotomy. Pre- and postoperative radiography, computed tomography, and recent follow-up images were examined. The pre- and postoperative Visual Analog Scale score and the Oswestry Disability Index score were evaluated for all patients. Whiteclouds' outcome analysis criteria were applied at the follow-up. Moreover, at study completion, patient feedback was collected; all the patients were asked to provide their opinion regarding the surgery and were asked whether they would recommend this procedure to other patients and them self undergo the same procedure again if required. Results: The most common site was the thoracolumbar junction. The symptom duration ranged from 1 month to 10 years preoperatively. Most patients experienced fusion by the end of 1 year, and the fusion mass could be observed as early as 4 months. Pseudoarthrosis void of up to 2.5 cm was noted to be healed in subsequent imaging. In addition, clinically, the patients reported good symptomatic relief. No patient required revision surgery. Whiteclouds' outcome analysis score at the latest follow-up revealed goodto-excellent outcomes in all patients. Conclusions: ALs can be treated using the posterior-only approach with long segment fixation and posterior spinal fusion. This is a safe, simple, and quick procedure that prevents the morbidity of anterior surgery.

단일 나사형 Cage를 이용한 후방 요추체간 융합술과 두개의 나사형 Cage를 이용한 PLIF의 생체 역학적 비교 (Posterior Lumbar Interbody Fusion Using Posterolateral Placement of A Single Cylindrical Threaded Cage and Two Regular Cages : A Biomechanical Study)

  • 박춘근;황장회;지철;권성오;성재훈;최승진;이상원;김문규;박성찬;조경석;박춘근;;강준기
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권7호
    • /
    • pp.883-890
    • /
    • 2001
  • Objectives : An in vitro biomechanical study of posterior lumbar interbody fusion(PLIF) with threaded cage using two different approaches was performed on eighteen functional spinal units of bovine lumbar spines. The purpose of this study was to compare the segmental stiffnesses among PLIF with one long posterolateral cage, PLIF with one long posterolateral cage and simultaneous facet joint fixation, and PLIF with two posterior cages. Methods : Eighteen bovine lumbar functional spinal units were divided into three groups. All specimens were tested intact and with cage insertion. Group 1(n=12) had a long threaded cage($15{\times}36mm$) inserted posterolaterally and oriented counter anterolaterally on the left side by posterior approach with left unilateral facetectomy. Group 2(n=6) had two regular length cages($15{\times}24mm$) inserted posteriorly with bilateral facetectomy. Six specimens from group 1 were then retested after unilateral facet joint screw fixation in neutral(group 3). Likewise, the other six specimens from group 1 were retested after fixation with a facet joint screw in an extended position(group 4). Nondestructive tests were performed in pure compression, flexion, extension, lateral bending, and torsion. Results : PLIF with a single cage, group 1, had a significantly higher stiffnesses than PLIF with two cages, group 2, in left and right torsion(p<0.05). Group 1 showed higher stiffness values than group 2 in pure compression, flexion, left and right bending but were not significantly different. Group 3 showed a significant increase in stiffness in comparison to group 1 for pure compression, extension, left bending and right torsion(p<0.05). For group 4, the stiffness significantly increased in comparison to group 1 for extension, flexion and right torsion(p<0.05). Although there was no significant difference between groups 3 and 4, group 4 had increased stiffness in extension, flexion, right bending and torsion. Conclusion : Posterior lumbar interbody fusion with a single long threaded cage inserted posterolaterally with unilateral facetectomy enables sufficient decompression while maintaining a majority of the posterior elements. In combination with a facet joint screw fixation, adequate postoperative stability can be achieved. We suggest that posterolateral insertion of a long threaded cage is biomechanically an ideal alternative to PLIF.

  • PDF

후방십자인대 재건술 후 사체 아킬레스 이식건의 초기연신거동 (Initial Lengthening Behavior of Cadaveric Achilles Tendon Graft After Posterior Cruciate Ligament Reconstruction)

  • 김철웅;배지훈;이호상;왕준호;박종웅;오동준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1461-1466
    • /
    • 2008
  • In the case of Posterior Cruciate Ligament (PCL), the most frequent mechanism is the dashboard injury, which is directly pressurized to the anterior of the proximal tibia in the state of the knee hyperflexion. The PCL associated ligament damage happens when the posterior injury, the varus, the valgus, the hyperextension and the severe vagus torque are out of the critical value of PCL. After the successful operation cases of Anterior Cruciate Ligament (ACL) reconstruction using the allograft were informed from 1986, a number of results kept over the maximum 10 years were reported. Unfortunately, PCL reconstruction are crowded the surgery techniques such as the graft, the tibia fixing method, the fixation device, the location of the femoral tunnel, the number of the graft bundles and PCL reconstruction to access to the stability of the normal joint is being developed. Therefore, this study is the basic research of these above facts. The current transtibial tunnel surgery using the cadaveric Achilles tendon grafts is chosen for the various PCL reconstruction. The initial extension of the Achilles tendon by the fixing device and its location under the cyclic loading, were observed.

  • PDF

내과의 부분후방절골술을 통한 거골연골모세포종의 수술적 치료: 증례 보고 (Surgical Treatment of Talar Chondroblastoma via Partial Posterior Medial Malleolar Osteotomy: A Case Report)

  • 유오준;서진수;김한성;최준영
    • 대한족부족관절학회지
    • /
    • 제27권2호
    • /
    • pp.75-78
    • /
    • 2023
  • During bone tumor resection, many cases require medial malleolar osteotomy to achieve adequate access to the operative field. Various osteotomy methods have been developed to address this issue, including oblique, transverse, reverse V-shape, and step-cut osteotomies. However, medial malleolar osteotomy has several drawbacks, such as the excessive disruption of the joint surface, unstable screw fixation when fixing the medial malleolus, and iatrogenic medial ankle joint arthritis due to articular displacement during the reduction of the osteotomy site. In addition, there is a possibility of injury to the posterior tibial artery, tibial nerve, or posterior tibialis tendon if the osteotomy range is too aggressive. Therefore, the authors propose a new osteotomy method, which has shown promising clinical results, namely, partial posterior medial malleolar osteotomy. This method minimizes articular involvement and provides adequate access to the operative field during talar body bone tumor resection.

제1,2경추골절의 치료 (Treatment of Atlantoaxial Fractures)

  • 진성철;김상진
    • Journal of Trauma and Injury
    • /
    • 제19권2호
    • /
    • pp.164-172
    • /
    • 2006
  • Background: The authors conducted a retrospective study to evaluate the mechanism of injury, the surgical techniques, the clinical features, the combined injuries, the treatment results, and the surgical complications in patients with atlantoaxial fracture/subluxations. Methods: The authors reviewed 71 cervical fracture/dislocations during a four-year period from September 2002 to August 2006. Among them, there were twenty one C1,2 fracture/subluxations. There were thirteen men (mean age : 43.5 years) and eight women (mean age : 50 years). Their follow-up period was at least 6 months, and the mean follow-up period was 9.6 months. Gardner-Wells tongs traction was used in all patients immediately on presentation. Surgical treatment was performed, depending on the pathologic conditions. Results: Of all 21 cases, 14 cases were injured in motor vehicle accidents, 5 were falls, and 2 were miscellaneous. There were four C1 fracture (5.6%), fourteen C2 fracture (66.7%), one C1 and 2 combined fracture (4.8%), and one C1-2 subluxation (4.8%). The C1 fractures in our series were classified as two Jefferson's fractures and two C1 lateral mass fracture. The C2 fractures were classified as one odontoid type I fracture, two odontoid type II fractures, five odontoid type III fractures, one hangman's fracture, and four C2 body tear-drop fractures. Atlantoaxial fractures were associated with six (28.6%) head injuries, four (19.0%) other spinal injuries, two (9.5%) chest injuries, and three (14.3%) spinal cord injuries. Surgical treatment was performed in nine cases, which included anterior odontoid screw fixation in two cases, transarticular screw fixation with iliac bone graft in one case, posterior fixation by using C2 pedicle screw and C3 lateral mass screw in three cases, lateral mass screw fixation C1-2 with iliac bone graft in one case, O(occipito)-C1-3-4 screw fixation in one case, posterior C2-3 wiring with allograft in one case, and halo vest in six cases. Conservative management was used in the rest of the patients in our trials. Bone fusion was complete in all cases. There were no operation-related complication, except one pin site infection in the case of halo vest. Conclusion: In this study, the choice of appropriate treatment according to the fracture types resulted in safe and effective management of unique atlantoaxial fracture/subluxations.

요추 고정수술 후 인접척추 운동범위의 변화 (The Change of Motion Ranges of Adjacent Vertebral Joints after Lumbar Fusion Operation)

  • 여상준;박승원;김영백;황성남;최덕영;석종식;정동규;민병국
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권11호
    • /
    • pp.1456-1460
    • /
    • 2000
  • Objectives : Transpedicular screw fixation has become an important method for internal fixation in variety of disorders. However, acceleration of degeneration at the adjacent segment in any follow. The goal of this study is to review the change of motion ranges of vertebral joints adjacent to fused level in lumbar spine. Methods : This study consists of 22 patients with degenerative spinal instability. Treatment of spinal instability includes posterior fusion with transpedicular screw fixation or transpedicular screw fixation with posterior lumbar interbody fusion. The flexion-extension angle(FEA) was measured from dynamic views of lumbar spine taken both at preoperative and post operative period. Results : The FEA of upper vertebral joint adjacent(FEA-u) to a fused L4-5 level was increased(p=0.010). The FEA-u was increased in case of L5-S1 fusion(p=0.025). The change of FEA-u in case of L5-S1 fusion was greater than that in L4-5 fusion(p=0.013). Conclusion : After L4-5 fusion, there seems to be more meaningful increase in FEA of L3-4 than that of L5-S1. The reason may be due to the damage of L3-4 facet joints during the operation, the other possible explanation may be the anatomical stability of L5-S1 vertebral joint. The change of FEA-u of L5-S1 fusion is increased more than that of L4-5 fusion. Because there are compensations in the adjacent vertebrae both above and below the fused L4-5, the compensatory motion in FEA-u of L5-S1 fusion was greater than that of the L4-5 fusion.

  • PDF

두경부암 환자의 양성자 치료 시 사용하는 자체 제작한 BoS Frame 고정장치의 선량학적 유용성 평가 (Dosimetric evaluation of using in-house BoS Frame Fixation Tool for the Head and Neck Cancer Patient)

  • 김광석;조광현;최병기
    • 대한방사선치료학회지
    • /
    • 제28권1호
    • /
    • pp.35-46
    • /
    • 2016
  • 목 적 : 두경부암의 양성자 치료 시 BoS frame ($Q-fix^{TM}$)을 사용하면 후사방향의 빔 조사 시 couch 와 snout 사이 충돌을 피하면서 Airgap 을 최소화할 수 있다. 이는 couch 에서 BoS frame 을 얼마나 많이 extended 시켰는지가 각 치료 빔 방향의 Airgap (환자와 빔 사출구 거리)을 결정하기 때문이다. 이에 본원에서는 BoS frame의 제한점을 개선하기 위하여 고정장치를 자체 제작하였고, 제작한 고정장치의 유용성을 본 연구를 통해 선량학적으로 평가하고자 한다. 대상 및 방법 : 본원에서 양성자치료를 받은 Brain Cancer환자 3명의 빔 각도 중 후사방향의 빔 6개를 선택하였다. 현재 치료계획 되어 있는 환자를 기존 방식대로 BoS frame만 사용했을 때 각 환자마다 왼쪽후사방향, 오른쪽 후사방향의 빔에서 충돌을 피할 수 있는 snout 위치를 측정하고 이 위치에 따른 Airgap과 Lateral penumbra 영역을 계산하고 DVH값을 분석하였다. 같은 환자의 동일한 빔에서 자체 제작한 BoS frame 고정장치를 사용하여 제조회사에서 권고한 set-up 사항보다 BoS frame을 21 cm superior방향으로 set-up을 진행하였고, 그 후 충돌을 피할 수 있는 snout위치를 측정하고 이 위치에서 Airgap과 Lateral penumbra영역을 계산하고 DVH값을 분석하였다. 결 과 : 자체 제작 BoS frame 고정장치를 사용함에 따라 사용하지 않았을 때 보다 snout 위치 즉 Airgap을 각각 각도별로 5.4 cm ~ 15.4 cm 줄일 수 있었다. Lateral penumbra는 BoS frame 고정장치를 사용하면서 Airgap을 감소시킴에 따라 각도별로 선량분포곡선에서 왼쪽, 오른쪽 부분을 0.1 cm ~ 0.4 cm 감소시킬 수 있었다. 자체 제작한 BoS frame 고정장치 사용함으로써 감소한 Lateral penumbra에 의해 정상조직에 들어가는 선량을 비교해보면 Lt.eyeball, Lt.lens, Lt.hippocampus, Lt.cochlea, Rt.eyeball, Rt.lens, Rt.cochlea, Rt. hippocampus, stem에 들어가는 선량이 0 CGE ~ 4.4 CGE 감소한 것을 알 수 있었다. 결 론 : 두경부암의 양성자 치료 시 자체제작 BoS frame 고정장치를 사용함에 따라 사용하지 않았을 때보다 후사방향의 빔에서 snout 위치를 감소시킬 수 있었고, Airgap을 줄여 결과적으로 Lateral penumbra를 감소시켜 정상조직에 불필요한 선량을 최소화 할 수 있었다. 이에 본 연구를 통해 자체제작 BoS frame 고정장치의 유용성을 선량학적으로 평가한 결과, 후사방향의 빔을 사용하는 두경부암 환자의 양성자 치료 시 유용하게 사용 될 것으로 기대된다. 마지막으로 두경부암 뿐만 아니라 다른 부위 양성자 치료에서도 Airgap을 최소한 할 수 있는 방법을 고안하여 Lateral penumbra를 줄일 수 있는 지속적인 연구가 필요할 것이라고 사료된다.

  • PDF

하악전돌증 환자의 하악지시상분할골절단술 후 고정방법에 따른 안정성과 회귀율에 대한 분석 (COMPARATIVE STUDY OF STABILITY AND RELAPSE ACCORDING TO FIXATION METHOD AFTER BILATERAL SAGITTAL SPLIT RAMUS OSTEOTOMIES IN MANDIBULAR PROGNATHIC PATIENTS)

  • 최희원;김경원;이은영
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권4호
    • /
    • pp.334-345
    • /
    • 2005
  • The purpose of this study was to compare the postoperative stability and relapse according to 2 different fixation methods after bilateral sagittal split ramus osteotomies in mandibular prognathic patients. Tweenty one patients with Class III dental and skeletal malocclusion who were treated with bilateral sagittal split ramus osteotomy were selected for this retrospective study. We classfied the patients into two groups according to the fixation methods of bony segments after osteotomies. Group W (n = 10) had the bone segments fixed with nonrigid wire and Group S (n = 11) had bicortical screws inserted in the gonial area through a transcutaneous approach. Cephalometric radiographs were taken preoperatively, immediate postoperatively and more than six months postoperatively in each patient. After tracing the cephalometric radiographs, various parameters were measured. Before surgery, both groups were balanced with respect to linear and angular measurements of craniofacial morphology. Mean posterior sagittal setback amounts of the mandibular symphysis was 8.6 mm in the wire group and 6.79 mm in the rigid group, Six months postoperatively, the wire group had 33.1% relapse of the mandibular symphysis and 22.8% in the rigid group relapse. Both groups experienced changes in the orientation and configuration of the mandible. It is thought that Rigid screw fixation is a more stable method than nonrigid wire fixation for maintaining mandibular setback after sagittal split ramus osteotomy.