• Title/Summary/Keyword: Post-tension

Search Result 288, Processing Time 0.026 seconds

Physicochemical properties, cytotoxicity and penetration into dentinal tubules of sodium hypochlorite with and without surfactants

  • Hernan Coaguila-Llerena;Isadora Barbieri ;Mario Tanomaru-Filho ;Renato de Toledo Leonardo;Ana Paula Ramos ;Gisele Faria
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.4
    • /
    • pp.47.1-47.11
    • /
    • 2020
  • Objectives: The aim of this study was to assess the physicochemical properties, cytotoxicity and penetration into dentinal tubules of ChlorCidTM Surf (3% sodium hypochlorite [NaOCl] with surfactant) in comparison to ChlorCidTM (3% NaOCl without surfactant). Materials and Methods: The physicochemical properties evaluated were pH, surface tension, free available chlorine (FAC) and contact angle. Cytotoxicity was evaluated in L929 fibroblasts exposed to the solutions by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide and neutral red assays. Assessment of penetration into dentinal tubules was performed by staining single-rooted permanent human teeth with crystal violet (n = 9), which were irrigated with the solutions and analyzed in cervical, middle and apical segments. Data were analyzed by one-way analysis of variance (ANOVA) and Tukey's post-test, 2-way ANOVA and Bonferroni's post-test or t-test (α = 0.05). Results: ChlorCidTM Surf and ChlorCidTM FAC values were close to those indicated by the manufacturer. ChlorCidTM Surf showed lower surface tension and contact angle on dentin, and higher pH than ChlorCidTM (p < 0.05). The penetration of ChlorCidTM Surf was higher in cervical and middle segments, compared with ChlorCidTM (p < 0.05). There was no difference in irrigant cytotoxicity (p > 0.05). Conclusions: ChlorCidTM Surf showed lower surface tension, lower contact angle on root canal dentin, higher penetration into dentinal tubules and more alkaline pH, compared with ChlorCidTM. However, both solutions showed similar cytotoxicity and FAC content.

The Acute Effect of Trimetazidine on the High Frequency Fatigue in the Isolated Rat Diaphragm Muscle

  • Emre, Mustafa;Karayaylali, Lbrahim;San, Mustafa;Demirkazik, Ayse;Kavak, Servet
    • Archives of Pharmacal Research
    • /
    • v.27 no.6
    • /
    • pp.646-652
    • /
    • 2004
  • The objective of this study was to determine the acute effect of trimetazidine (TMZ) on the pre-fatigue, fatigue and post-fatigue contractile characteristics and tension-frequency relationships of isolated rat diaphragm muscle. Muscle strips were taken from the ventral-costal aspects of the diaphragm muscle of rats killed by decapitation. The muscle strips were suspended in organ baths containing Krebs solution, with a gas mixture of 95% $O_2$ and 5% $CO_2$ at $37^{\circ}C$ and pH 7.35-7.45. After determining the thermoregulation and optimum muscle length the muscles were subjected to direct supramaximal stimulation with 0.05 Hz frequency square pulses for periods of 0.5 msec to obtain control values. After adding $5{\times}10^{-6}{\;}and{\;}5{\times}10^{-5}$ M trimetazidine solution to the respective bath media, the contractile parameters of the muscles were recorded. The contractile parameters were also recorded for both the trimetazidine and tri-metazidine-free media after application of the high frequency fatigue protocols. Later, the tension-frequency relationship was determined by applying stimulating pulses of 10, 20, 50 and 100 Hz to the muscle strips. Whilst the twitch tension obtained from the $5{\times}10^{-6}{\;}and{\;}5{\times}10^{-5}$ M trimetazidine media showed numerical increases compared to that of the controls, these were not statistically significant (p>0.05). The contraction time exhibited a dose dependent increase (p<0.001), whilst the contraction and relaxation rates did not differ significantly. The isometric contraction forces obtained with the different stimulating frequencies showed a significant increase in the tetanic contraction only at 100 Hz (p<0.05). A comparison of the pre- and post-fatigue twitch tensions in the trimetazidine media showed the post- fatigue twitch tensions to be significantly higher than those of the pre-fatigue contraction forces (p<0.05). In the $5{\times}10^{-6}{\;}and{\;}5{\times}10^{-5}$ M trimetazidine media the increases in the post-fatigue contraction force were 22 and 30%, respectively. These results demonstrated that in isolated rat diaphragm muscle, TMZ significantly limited the mechanical performance decrease during fatigue. It is our opinion that trimetazidine contributed to the observed fatigue tolerance by eliminating the factors of fatigue, due to preservation of intracellular calcium homeostasis, provision of the ATP energy levels needed by ATPase dependent pumps and especially by keeping the intracellular pH within cer-tain limits.

Effects of High-frequency Diathermy Integrated into Suboccipital Release on Tenderness and Neck Mobility and Disability in People with Chronic Tension-type Headache (뒤통수밑근 이완기법과 병행된 고주파 심부투열이 만성 긴장성 두통 환자들의 압통과 목 가동성 및 기능장애에 미치는 영향)

  • Lee, Hyoung-ryeol;Shim, Jae-hun;Oh, Duck-won
    • Physical Therapy Korea
    • /
    • v.24 no.2
    • /
    • pp.37-47
    • /
    • 2017
  • Background: Active trigger points (TrPs) of the suboccipital muscles greatly contribute to the occurrence of chronic tension-type headache, with increased sensitivity of TrPs and facilitated referred pain. Objects: This study aimed to investigate whether the integration of high-frequency diathermy into suboccipital release is more beneficial than the use of suboccipital release alone. Methods: Thirty subjects were assigned to either experimental group-1 (EG-1) to undergo suboccipital release combined with high-frequency diathermy (frequency: 0.3 MHz, and electrode type: resistive electronic transfer), or EG-2 to undergo suboccipital release alone, or the control group (CG) with no intervention, with 10 subjects in each group. The assessment tools included the headache impact test 6 (HIT-6), perceived level of tenderness, neck disability index, and neck mobility. Intervention was performed for 10 minutes, twice per week, for 4 weeks, and measurements were performed before and after the interventions. Results: The between-group comparison of the post-test values and changes between pretest and post-test showed significant differences for all parameters at p<.05, except for the left-to-right lateral bending range. In the post hoc test, EG-1 showed significant differences for the parameters in comparison with the CG, while no significant differences in the perceived tenderness level, on both temporal regions, were found between EG-2 and CG. Furthermore, the HIT-6 score and perceived tenderness level, in the right temporal region, showed significant differences between EG-1 and EG-2. In the within-group comparison, EG-1 and EG-2 appeared to be significantly different between pretest and post-test (p<.05), except for the perceived tenderness level in the right temporal region, with significance for the EG-1 group only (p<.05). Conclusion: These findings suggest that the suboccipital release technique may be advantageous to improve headache, tenderness, and neck function and mobility, with more favorable effects with the incorporation of high-frequency diathermy.

Applicability of Partial Post-Tension Method for Deflection Control of Reinforced Concrete Slabs (RC슬래브의 처짐제어를 위한 상향긴장식 부분PT공법의 적용)

  • Lee, Deuck-Hang;Kim, Kang-Su;Kim, Sang-Sik;Kim, Yong-Nam;Lim, Joo-Hyuk
    • Journal of the Korea Concrete Institute
    • /
    • v.21 no.3
    • /
    • pp.347-358
    • /
    • 2009
  • Recently, it is getting into a good situation for the flat-plate slab system to be applied. The flat-plate slab without beam, however, is often too weak to control deflection properly compared to other typical slab-beam structures, for which the post-tension method is generally regarded as one of best solutions. The post-tension (PT) method can effectively control deflection without increase of slab thickness. Despite this good advantage, however, the application of PT method has been very limited due to cost increase, technical problems, and lack of experiences. Therefore, in order to reduce difficulties on applying full PT method under the current domestic circumstances and to enhance constructability of PT system, this research proposed the partial PT method with top jacking anchorage applied in a part of span as need. For the top jacking anchorage system, the efficiency of deflection control shall be considered in detail because it can vary widely depending on the location of anchorage that can be placed anywhere as need, and tensile stresses induced at back of the anchorage zone also shall be examined. Therefore, in this study, analysis were performed on the efficiency of deflection control depending on the location of anchorage and on tensile stresses or forces using finite element method and strut and tie model in the proposed top jacking anchorage system. The proposed jacking system were also applied to the floor slabs at a construction site to investigate its applicability and the analysis results of slab behavior were compared to the measured values obtained from the PT slab constructed by the partial PT method. The result of this study indicates that the partial PT method can be very efficiently applied with little cost increase to control deflection and tensile stresses in the region as a need basis where problem exists.

Dynamic Characteristic of Composite Beam using the Sandwich Plate System (샌드위치 플레이트 시스템을 이용한 합성보의 동적 특성)

  • Ryu, Jae-Ho;Ju, Young-Kyu;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.14 no.4
    • /
    • pp.65-72
    • /
    • 2014
  • To improve the noise and vibration problems of the existing public parking systems, new floor system was proposed. This system consists of the Sandwich Plate System(SPS), steel beam and post-tensioned steel tendons. To verify the dynamic characteristics such as the natural frequency and damping ratio of the system, the free vibration test was performed. Test results showed that the natural frequency of the SPS composite beam was 23.8Hz and it was increased by 3.8% by installing the post-tensioned tendons. The damping ratio of the specimen with tendons was about 1.64%.

Determination of Effective Prestress of Post-tensioned Precast Bridge Piers (포스트텐션 조립식 교각의 유효프리스트레스 크기 결정)

  • Shim, Chang Su;Koem, Chandara
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.135-143
    • /
    • 2016
  • In this paper, a design concept of post-tensioned precast bridge piers was proposed to improve seismic behavior of the bridge pier. Mild reinforcing bars are placed continuously along the height of the column. Prestressing tendons are also provided to obtain re-centering capability for seismic events. Arrangement of the axial steels to prevent buckling of rebars at plastic hinge region was suggested and enhanced seismic performance was verified by experiments. Moment-curvature analyses were performed to evaluate the effect of effective prestress on seismic behavior after verifying the calculation method by cyclic tests of the precast columns. A real bridge pier was designed to investigate the seismic performance according to different level of effective prestress. Level of effective prestress showed obvious effect on crushing displacement but negligible effect on lateral displacement at fracture of tendons and reinforcements.

Structural Analysis and Design of Post-Tension Transfer Slab (포스트텐션 전이슬래브의 구조해석 및 설계방법)

  • Yoon, Jang-Keun;Kang, Su-Min;Kim, Ook-Jong;Lee, Do-Bum;Choo, Moon-Suk
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.19-20
    • /
    • 2010
  • Post-tensioning is an effective way to reduce both the depth and reinforcement contents for the reinforced concrete member. In this research, we applied post-tensioning to transfer slab in shear wall type apartment building to reduce depth and reinforcement of transfer slab.

  • PDF

Peripheral Post-traumatic Cervical Dystonia Treated by Miniscalpel-Acupuncture: A Case Report (말초성 외상후 경부 근긴장이상증에 대한 도침치료: 증례 보고)

  • Yoon, Sang-Hoon;Jo, Hee-Guen;Kwon, Min-Goo;Song, Min-Yeong
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.28 no.1
    • /
    • pp.161-166
    • /
    • 2018
  • This report describes the miniscalpel-acupuncture treatment of a 68-yr-old woman who had abnormal posture and involuntary dystonic movements of the head and neck. She suffered muscle contracture associated symptoms after she fell injured in 2014. Her neck had abnormal posture findings due to muscle tension. The spasms gradually worsened and did not respond to botulinum toxin injections. Involuntary dystonic movements may be due to peripheral post-traumatic cervical dystonia. Outcomes support cervical dystonia may be managed effectively with miniscalpel-acupuncture. Further research is recommended.

Post-heating behavior of concrete beams reinforced with fiber reinforced polymer bars

  • Irshidat, Mohammad R.;Haddad, Rami H.;Almahmoud, Hanadi
    • Structural Engineering and Mechanics
    • /
    • v.53 no.6
    • /
    • pp.1253-1269
    • /
    • 2015
  • The present paper investigates the post heating behavior of concrete beams reinforced with fiber reinforced polymer (FRP) bars, namely carbon fiber reinforced polymer (CFRP) bars and glass fiber reinforced polymer (GFRP) bars. Thirty rectangular concrete beams were prepared and cured for 28 days. Then, beams were either subjected (in duplicates) to elevated temperatures in the range (100 to $500^{\circ}C$) or left at room temperature before tested under four point loading for flexural response. Experimental results showed that beams, reinforced with CFRP and GFRP bars and subjected to temperatures below $300^{\circ}C$, showed better mechanical performance than that of corresponding ones with conventional reinforcing steel bars. The results also revealed that ultimate load capacity and stiffness pertaining to beams with FRP reinforcement decreased, yet their ultimate deflection and toughness increased with higher temperatures. All beams reinforced with FRP materials, except those post-heated to $500^{\circ}C$, failed by concrete crushing followed by tension failure of FRP bars.

A Study on the Preocessing of high Runctional Composites and the Evaluation of Its Characteristics (고기능성 복합재료의 제조와 그 특성평가에 관한 연구)

  • 김윤해
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.2
    • /
    • pp.139-145
    • /
    • 1998
  • Filament winding method is widely used for composite fabrications using low viscosity liquid for-mation and processing asymmetrical structures of pressure vessel pipe rocket motor case etc. The filament winding method is affected by several parameters such as pot life of process time viscosi-ty of resin filament winding temperature and schedules curing condition and post curing condi-tion of resin. To develope high functional composite materials the rotation(5, 15, 20, 30rpm) of the winding machine was controlled by D.C motor. And the wiper to give proper tension was equipped between strand and resin bath. The resin is hooked by the design wiper. The adequate cure schedule was found by DSC. NOL ring test is carried out to investigate the basic physical properties such as design technology. The void contents in filament winding is generally higher than that of the prepreg laminated plate. These high contents of void can make a crack in resin in spite of low deformation. These problem was solved by giving tension in processing. To improve the characteristics of fiber volume fraction void contents resin/fiber bonding the winding speedc is changed under constant tension. It was found that resin impregnation was not different from in fiber contents void contents at the range of 0.5~1kg tension but it was found that resin was not impregnated at the above of 1.5kg tension. In burst test a pure PE liner was failed at a nozzle part under the $14kg/\textrm{cm}^2$ pressure but a pressure vessel of CNG was failed at a cylinder part under the $200kg/\textrm{cm}^2$ pressure.

  • PDF