• Title/Summary/Keyword: Post-Processing

Search Result 1,753, Processing Time 0.026 seconds

Utilzation of Ascidian, Holocynthia roretzi -5. Processing and Quality Evaluation of Fermented Ascidian(I)- (우렁쉥이 이용에 관한 연구 -5. 우렁쉥이 젓갈의 제조 및 품질평가( I )-)

  • LEE Kang-Ho;CHO Ho-Sung;LEE Dong-Ho;RYUK Ji-Hee;CHO Young-Je;SUH Jae-Soo;KIM Dong-Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.26 no.3
    • /
    • pp.221-229
    • /
    • 1993
  • In this study fermentation of fresh ascidian was attempted to widen the utility of ascidian. Fresh deshelled and sliced ascidians were fermented for 90days at $25^{\circ}C$ with different salt contents of 5, 10, 15 and $20\%$ (w/w) and at $5^{\circ}C$ with 5 and $10\%$ salt. Changes of such components during fermentation as free amino acids, nucleotides and the related compounds, volatile basic nitrogen(VBN), trimethyl amine(TMA), amino nitrogen and total creatinine were determined. VBN increased rapidly after 30days of fermentation at $25^{\circ}C$ while slowly in cases of fermentation at $5^{\circ}C$ and with high salt concentration. Amino nitrogen and the total creatinine also increased gradually until 45 days and 30days of fermentation, respectively, hereafter tended to decrease. ATP and ADP seemed to degrade rapidly in fresh ascidian post harvest and AMP, IMP and inosine also degraded down to hypoxanthine during fermentation. After 45days of fermentation, in the free amino acid composition of fermented ascidian were taurine, proline, glutamic acid, histidine, lysine, alanine and valine in order. The amino acids known as sweetner like prolline, lysine, alanine and glycine were in increased in fermented ascidian. The result of sensory evaluation of fermented ascidian pretreated with acid or sulfite solution showed that the peculiar taste and flavor of ascidian remained without browning for 45days fermentation at $5^{\circ}C$.

  • PDF

A Study on the Measurement of the Pollution Level of Bacteria and Disinfection of Table and IP Cassette (촬영 테이블과 IP Cassette의 세균 오염도 측정 및 소독에 관한 연구)

  • Bae, Seok-Hwan;Lee, Moo-Sik;Lim, Chang-Seon;Kim, Gha-Jung
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.229-237
    • /
    • 2008
  • Purpose : For the number of microbes and the pollution level of bacteriology of IP Cassette and Table by laboratories, after identifying the bacteria before and after using alcohol and tissue including disinfectant and statistically testing, this research was intended to provide the basic data for the prevention and the right disinfection guideline for infection management of hospitals in diagnostic radiology. Subject and Method : The subject of this research was the general room of diagnostic radiology of a university hospital in Daejeon City. The research was conducted from Apr 5 to Apr 12, 2007. The number of microbes and the pollution level of bacteriology of IP Cassette and Table by laboratories were tested before and after using alcohol and tissue for disinfection including disinfectant. In order to collect specimens exactly, they were collected with the nurse who specialized in infection management of the hospital, and statistical processing was done with SPSS V13.0. To compare the results before and after using alcohol and tissue, T-test was implemented, and post-hoc test was conducted. Results : Bacteria were detected in 19 cases of 24 subjects(79.2%), however, they were not detected in 5 cases(20.8%). 7kinds of bacteria were detected as isolated bacteria, of which Methicillin Resistant coagulase-negative Staphylococci(MRCNS) were detected in 15 cases(62.5%), which was most, Methicillin Resistant Staphylococcus Aureus(MRSA) in 6 cases(16.7%), Enterococcus Faecium(EFM) in 5 cases(20.8%), Acinetobacter baumannii(ABA) in 2 cases(8.3%), and Bacillus sp, Coagulase-negative Staphylococci(CNS), and Enterococcus sp(ENT) in 1 case, respectively(4.2%). In all bacteria except ABA, Gram positive bacillia were detected in 30 cases(97%), and Gram negative bacilli were detected only in 1 case(3%). As for the kinds of bacteria and the number of groups before and after using 70% Alcohol by Groups, when the bacteria were identified after disinfecting IP Cassette and Table with 70% Alcohol, all the bacteria became extinct in both IP Cassette and Table Group(100%). As for the kinds and number of bacteria before and after using Tissue Cleaner by Groups, the bacteria in Tissue Cleaner Group became completely extinct only in 10 Groups(71.2%), and in 4 Groups, there was much decrease in bacteria, however, they were still detected. The extinction rate of all the bacteria was 91.5%. That is, though the other bacteria became extinct(100%), that of MRCNS bacteria was lowest(83.6%), followed by MRSA(95%). Conclusion : As a result of comparing the mean of the bacteria which were detected before and after using 70% Alcohol and Tissue Cleaner, there was statistically significant in the significant level of 5% in both of them.

  • PDF

A Functional MRI Study on the Brain Activation Associated with Mental Calculation (기능적 자기공명영상을 이용한 수리연산의 대뇌 활성화에 관한 연구)

  • Choi Dae Seob;Na Dong Gyu;Kim Sam Soo;Cho Jae Min;Park Eui Dong;Chung Sung Hoon;Ryoo Jae Wook
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.1
    • /
    • pp.16-23
    • /
    • 2005
  • Purpose : In order to investigate the functional brain anatomy associated with mental calculation, functional magnetic resonance imaging was performed. Materials and Methods : In six normal right handed subjects, functional MR images were obtained using a 1.57 MR scanner and the EPI BOLD technique. The study included experiment I and experiment II. Each experiment consisted of five resting and four activation periods with each period of 30 seconds. During the activation period of both experiment I and II, calculation equations[an example: $(4+5)\times8=72$] were presented and the subjects were instructed to decide true or false of them. During the resting period of experiment I, the subjects were instructed to visually fixate on a crosshair. During the resting period of experiment II, two diagrams (an example: $(\bullet,\;\blacksquare)$)were presented and the subjects were instructed to decide they are same or not. For the post-processing of images, the SPM program was used, with the threshold of significance set at p<0.00001. The activated areas during the tasks were assessed. Results : In experiment 1, the inferior frontal gyrus, prefrontal cortex, promoter area, supplementary motor area, and intraparietal sulcus including superior parietal cortex were activated bilaterally. Although these areas were also activated in experiment II, the activated signals in the right frontal and parietal lobes were lessened. Conclusion : The left inferior frontal gyrus and prefrontal cortex and bilateral intraparietal sulci were activated during mental calculation. The right frontal and parietal lobes might be related to attention and decision making.

  • PDF

An Analysis of Factors That Affect Image Quality Deterioration in The Potable X-ray Examination on using Digital Wireless Detector (디지털 무선 검출기를 이용한 이동형 X선검사에서 영상품질 저하의 요인분석)

  • Yu, Young-Eun;Lim, Cheong-Hwan;Ko, Joo-Young
    • Journal of radiological science and technology
    • /
    • v.37 no.2
    • /
    • pp.93-100
    • /
    • 2014
  • Recently the development of portable digital wireless imaging system, which acquires digital radiation images by using wireless LAN telecommunications function in an easy and fast way, provides lots of convenience for people. Considering the characteristics of portable imaging tests on emergency and critical patients, this study aims to suggest guidelines for Digital wireless detector by evaluating the effect of de-centering of focus-grid and displacement of subject in detector on the quality of image. The equipments used for this study were Elmo-T6 Digital Mobile X-ray system (SIMAZU Corp.), el' Tor ($14{\times}17$ "Wireless detector), Grid (10:1) and Chest & head phantom. After acquiring post-processing image according to dose increase and de-centering image of grid-focus and head phantom displacement image, this study compared, analyzed and evaluated these images by using a digital image analysis program by Image J. In the change of images based on dose increase, images were rough in the dose of 0.5 mAs, while there was no difference among images in the proper dose of 1~2 mAs and, especially from 2.5 mAs, average value of pixels radically decreased, affecting contrast. Over 3 mAs, contrast dropped due to saturation phenomenon of lungs. As the result of analysis using Image J program, with the increase of displacement between focus-grid and head phantom, the frequency of low pixel value also increase, causing the outline of surface image to disappear, which in turn affects contrast. For better quality imaging, a radiographer must be aware before the time of test that the image quality can be changed based on the critical patient's posture, movement, respiration, displacement of X-ray tube and distance of imaging.

Clinical Usefulness of Arterial Spin Labeling Perfusion MR Imaging in Acute Ischemic Stroke (급성 허혈성 뇌경색 환자에서 동맥스핀표지 관류자기공명영상의 유용성)

  • Oh, Keun-Taek;Jung, Hong-Ryang;Lim, Cheong-Hwan;Cho, Young-Ki;Ha, Bon-Chul;Hong, Doung-Hee
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.323-331
    • /
    • 2011
  • We evaluated clinical usefulness of Arterial spin labeling perfusion MR imaging on the acute ischemic cerebral infarction patients through this study. We compared 22 patients who were done with DSC imaging and ASL imaging in admitted emergency room with acute ischemic cerebral infarction, with 36 normal comparison persons (DSC image on 21persons, ASL images on 15persons). Siemens Magnetom Verio 3.0T with 12 channel head coil was used for this study. DSC image obtained 4 maps(rCBV, rCBF, rMTT, TTP) through post-processing. For qualitative analysis we compared the area of lesion macro-diagonal with the size of diffusion weighted MR image for rMTT, TTP, rCBF, rCBV, ASL maps. For Quantitative analysis we analyzed significant correlations between less than 3 cm infarction group and normal comparison group using mean relative value of flowing image with Mann-Whitney U test. TTP(95.5%) and rCBF(95.5%) maps showed high recognition rate in qualitative analysis for >3cm infarction group. The rCBF and rCBV map tests were highly related with final stage stroke areas. Mean relative value of infarction group showed a significant correlations in quantitative analysis(p<0.05). As a conclusion, arterial spin labeling image showed high lesion recognition rate in the >3cm infarction group. Mean relative values in quantitative evaluation were used for reference data. If we do more sustainable researches, ASL image will be useful for an early diagnosis of cerebral infarction, determination of the range of ischemic pneumbra and effective treatments.

An Implementation Method of the Character Recognizer for the Sorting Rate Improvement of an Automatic Postal Envelope Sorting Machine (우편물 자동구분기의 구분율 향상을 위한 문자인식기의 구현 방법)

  • Lim, Kil-Taek;Jeong, Seon-Hwa;Jang, Seung-Ick;Kim, Ho-Yon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.12 no.4
    • /
    • pp.15-24
    • /
    • 2007
  • The recognition of postal address images is indispensable for the automatic sorting of postal envelopes. The process of the address image recognition is composed of three steps-address image preprocessing, character recognition, address interpretation. The extracted character images from the preprocessing step are forwarded to the character recognition step, in which multiple candidate characters with reliability scores are obtained for each character image extracted. aracters with reliability scores are obtained for each character image extracted. Utilizing those character candidates with scores, we obtain the final valid address for the input envelope image through the address interpretation step. The envelope sorting rate depends on the performance of all three steps, among which character recognition step could be said to be very important. The good character recognizer would be the one which could produce valid candidates with very reliable scores to help the address interpretation step go easy. In this paper, we propose the method of generating character candidates with reliable recognition scores. We utilize the existing MLP(multilayered perceptrons) neural network of the address recognition system in the current automatic postal envelope sorters, as the classifier for the each image from the preprocessing step. The MLP is well known to be one of the best classifiers in terms of processing speed and recognition rate. The false alarm problem, however, might be occurred in recognition results, which made the address interpretation hard. To make address interpretation easy and improve the envelope sorting rate, we propose promising methods to reestimate the recognition score (confidence) of the existing MLP classifier: the generation method of the statistical recognition properties of the classifier and the method of the combination of the MLP and the subspace classifier which roles as a reestimator of the confidence. To confirm the superiority of the proposed method, we have used the character images of the real postal envelopes from the sorters in the post office. The experimental results show that the proposed method produces high reliability in terms of error and rejection for individual characters and non-characters.

  • PDF

A Study on the Physique and Physical Fitness According to Skeletal Maturation of Obese Children (비만 아동의 골격성숙도에 따른 체격, 체력에 관한 연구)

  • Kim, Dae-Hoon;Yoon, Hyoung-ki;Oh, Sei-Yi;Lee, Young-Jun;Kim, Buem-Jun;Choi, Young-Min;Song, Dae-Sik;An, Ju-Ho;Seo, Dong-Nyeuck;Kim, Ju-Won;Na, Gyu-Min;Oh, Kyung-A
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.3
    • /
    • pp.594-603
    • /
    • 2020
  • The aim of this study was to investigate the issue in obese children with a high probability of leading to precocious puberty for they have more advanced skeletal maturation compared to normal children in order to contribute to the health of obese children by identifying the relationship between physique and physical fitness according to their skeletal maturation. A total of 243 obese children between the ages of 10-13 were enrolled as subjects, and the skeletal maturation, which symbolize indicators of biological maturation, were evaluated by using the TW3 method after hand-wrist radiographs, thus classified the skeletal maturation level into retarded group(n=70), normal group(n=128), and advanced group(n=45). A stadiometer and InBody 270 (Biospace, Korea) were used to measure 3 components in physique. A total of 7 components in physical fitness, which included muscular strength, muscular endurance, flexibility, power, cardiovascular endurance, balance, agility, were measured as well. Descriptive statistics and one-way variable analysis (ANOVA) were conducted for data processing using SPSS 25.0, and Duncan's multiple-range method was used for post hoc analysis; and it was considered significant at the level of P< .05. Analysis results of this study may be summarized as follow. First, height and weight in physique factors according to the skeletal maturation between the retarded, normal, and advanced groups in males and females were highly significant. Second, physical fitness comparison according to the skeletal maturation in males were statistically significant in muscular strength, power, and agility whereas muscular strength and balance were statistically significant in females.

Distribution of Trypsin Indigestible Substrate(TI) in Seafoods and Its Changes during Processing - 1. Distribution and Post-mortem Changes of TI in Fish Muscle - (어패류(魚累類)의 Trypsin활성(活性) 저해물질(沮害物質) (TI)의 분포(分布)와 가공(加工) 중(中)의 변화(變化) - 1. 어육(魚肉) 중(中)의 TI의 분포(分布)와 어도저하(鮮度低下)에 따른 변화(變化) -)

  • Lee, Kang-Ho;Kim, Wha-Sim;Ryu, Hong-Soo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.13 no.1
    • /
    • pp.33-41
    • /
    • 1984
  • To obtain the fundamental data on the nutritional value of protein for fresh meat, it was per- formed the distribution of Tl(trypsin indigestible substrates) and the apparent in vitro protein digestibility in 8 species of dark-fleshed fishes and8 species of white-fleshed fishes which were consumed in Korea popularly. It was also investigate the changes in VBN and TBA value during frozen storage at $-10^{\circ}C$on the purpose of assaying the antinutritional factors that affect on apparent in vitro protein digestibility or Tl forming. Tl content in dark-fleshed fishes were varied with their species, ranged from 0.02 to 0.17 mg/g. using the method by Hamerstrand, while that in white-fleshed fishes was almost same, ranged from 0.10 to 0.26 mg/g. For all the fresh fish samples, however, the apparent in vitro protein digestibility were showed the value from 83 to 83%. In comparison with the parts of pacific mackerel, viscera had the most abundant Tl content as much as 0.3m g/g, while a trace was noted for skin and dark muscle had more Tl content than ordinary muscle based on the method by Hamerstrand. The apparent in vitro protein digestibility for all samples was dropped but the changes of VBN and TBA were retested the similar tendency with the increasing Tl content during frozen storage at $-10^{\circ}C$. Therefore, it could be concluded that Tl contbnt and apparent in vitro protein digestibility were affected by its freshness and fat oxidation and that, especially, fat was assumed to play an important role on apparent in vitro protein digestibility.

  • PDF

Comparative accuracy of new implant impression technique using abutments as impression copings with an angulated implant model (경사지게 식립된 임플랜트 모형에서 지대주를 인상용 코핑으로 이용한 새로운 인상법의 정확성 비교 연구)

  • Lee, Hyeok-Jae;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.201-208
    • /
    • 2008
  • Statement of problem: A new implant impression technique which use abutments as impression coping, and use resin cement as a splinting material was described. Accuracy of this technique was compared with conventional closed tray and resin splinted open tray technique for a $15^{\circ}$ angled 3-implant model Material and methods: A dental stone master model with 3 linearly positioned implant analogue and a reference framework which was passively fitted to it were fabricated. The center analogue was perpendicular to the plane of model and the outer analogues had a $15^{\circ}$angulation forward or backward. 10 closed tray impressions, 10 resin splinted open tray impressions, 10 abutment-resin framework cementation impressions and 10 abutment-metal framework cementation impressions were made with additional silicone material and poured with dental stone. A light microscope with image processing was used to record the vertical gap dimension between reference framework and analogue of duplicated cast made with each 4 impression techniques. Statistical analysis used one-way ANOVA with post-hoc tests Tukey test of .05 level of significance Results: Significant difference in the vertical gap dimension was found between closed tray technique; 74.3 (${\pm}33.4$)${\mu}m$ and resin splinted open tray technique, and two other new technique. (P<.05) Abutment-metal framework cementation technique;42.5 (${\pm}11.9$)${\mu}m$ was significantly different from resin splinted open tray technique. (P<.05) Abutmentresin framework cementation technique;51.0 (${\pm}14.1$)${\mu}m$ did not differ significantly from resin splinted open tray technique;50.3 (${\pm}16.9$)${\mu}m$. (P>.05) Conclusion: Within limitations of this study, the accuracy of implant level impressions of resin splinted open tray technique was superior to that of closed tray technique. A new technique using abutment and metal framework cementation was more accurate than resin splinted open tray technique.

Plateletpheresis: the Process, Devices, and Indicators of Product Quality (혈소판성분채집술: 채집과정, 장비, 성분채집혈소판 질의 지표들)

  • Jang, Chul-Soo;Kim, Sung-In;Kim, Hyun-Kyung;Kweon, Chang-Oh;Kim, Byung-Won;Kim, Dong-Chan;Kim, Yoon Suk;Rhee, Ki-Jong;Ryu, Jae-Ki
    • Journal of Life Science
    • /
    • v.24 no.9
    • /
    • pp.1030-1038
    • /
    • 2014
  • Platelet products are used to treat hemorrhagic or platelet dysfunction diseases. Plateletpheresis involves collecting the platelet components of blood using an apheresis blood-collection system. Various indicators are available for evaluating the qualities of the apheresis platelets. The productivity of platelet collection is evaluated through both the collection efficiency and collection rates. Platelet storage quality can be evaluated in vitro using several indicators, including visual appearance, metabolic activities, volume, platelet count, white blood cell count, microparticles, and various platelet activation markers. Platelet activation markers have been used as indicators of storage quality in various studies. Post-transfusion platelet quality can be evaluated based on the corrected count increment and the percentage of platelet recovery. Although various studies have investigated the aspects of plateletpheresis, no article has systemically presented assessments of the platelet products obtained from different plateletpheresis devices. The present study provides a review of plateletpheresis, including the specifics of the process, the types of devices employed, the platelet quality, the overall efficacy, and the evaluation indicator qualities. Furthermore, the differences in functionality among the different apheresis devices are discussed. Although adverse reactions to the citrate anti-coagulant have been reported, apheresis processing may provide a safer option for donors who are at a high risk for presyncopal or syncopal reactions related to whole blood collection.