• Title/Summary/Keyword: Possibility of a fire

Search Result 320, Processing Time 0.026 seconds

A Study on Reinforcement of Fire Safety in Residential Spaces of Low-Income Classes (저소득계층 주거 공간 화재안전성 강화를 위한 연구)

  • Park, Nam-Kwon
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.4
    • /
    • pp.882-889
    • /
    • 2021
  • Purpose: The purpose of this study was to improve fire safety in Gosiwon, a residential space for the low-income class. Method: Problems appearing in the process of fire occurrence and damage were verified once again. In addition, we would like to suggest improvement measures through systematic discussions on blind spots. Results: As a result of examining the risk of cool fire, the causes of fire occurred in various ways. In addition, the possibility of radiant heat due to heat accumulation due to narrow rooms inside the Gosiwon was high. Also, it was found that the possibility of fire spread was high due to clothing and household goods. It was reconfirmed that the poor internal structure of a narrow indoor space had a significant effect on the spread of fire and the scale of damage as it tried to accommodate as many people as possible inside. Conclusion: It is necessary to complete the installation as soon as possible for Gosiwon where the simple sprinkler is not installed. For this, a stronger driving force from the government and local governments is needed. In addition, it will be necessary to discuss how to improve the spatial and structural fire vulnerabilities that appear due to the structural characteristics of the Gosiwon.

A Study on the Evaluation of Reliability of the Vacuum Circuit Breaker for the Electrical Fire (전기화재에 따른 진공차단기의 건전성 평가)

  • Choi, Hong-Kyoo;Park, Joon-Yeol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.7
    • /
    • pp.24-28
    • /
    • 2013
  • Fire-hited electrical equipment has possibility of deterioration. So its replacement is essential in terms of safety. However, the economic burden is increased. Therefore, the replacement or re-use of it is to be determined by tests. But the research of Integrity Assessment on Fire-hited electrical equipments is very rare. In this paper, we tested to determine the replacement or re-use of Fire-hited vacuum circuit breaker. And provided the data for the integrity assessment through the analysis of its deterioration.

A Knowledge-based Electrical Fire Cause Diagnosis System using Fuzzy Reasoning (퍼지추론을 이용한 지식기반 전기화재 원인진단시스템)

  • Lee, Jong-Ho;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.3 s.75
    • /
    • pp.16-21
    • /
    • 2006
  • This paper presents a knowledge-based electrical fire cause diagnosis system using the fuzzy reasoning. The cause diagnosis of electrical fires may be approached either by studying electric facilities or by investigating cause using precision instruments at the fire site. However, cause diagnosis methods for electrical fires haven't been systematized yet. The system focused on database(DB) construction and cause diagnosis can diagnose the causes of electrical fires easily and efficiently. The cause diagnosis system for the electrical fire was implemented with entity-relational DB systems using Access 2000, one of DB development tools. Visual Basic is used as a DB building tool. The inference to confirm fire causes is conducted on the knowledge-based by combined approach of a case-based and a rule-based reasoning. A case-based cause diagnosis is designed to match the newly occurred fire case with the past fire cases stored in a DB by a kind of pattern recognition. The rule-based cause diagnosis includes intelligent objects having fuzzy attributes and rules, and is used for handling knowledge about cause reasoning. A rule-based using a fuzzy reasoning has been adopted. To infer the results from fire signs, a fuzzy operation of Yager sum was adopted. The reasoning is conducted on the rule-based reasoning that a rule-based DB system built with many rules derived from the existing diagnosis methods and the expertise in fire investigation. The cause diagnosis system proposes the causes obtained from the diagnosis process and showed possibility of electrical fire causes.

Efficient Disaster Response Plan for Tunnel Fire Safety (터널 화재안전에 대한 효율적 재난대응 방안)

  • Jeong-Il Lee
    • Journal of the Korea Safety Management & Science
    • /
    • v.26 no.2
    • /
    • pp.55-64
    • /
    • 2024
  • As the distribution of vehicles and logistics increases due to the development of human civilization and the increase in population, various roads play an important role in domestic traffic and transportation. However, the recent emergence of large cities and new cities is causing traffic problems, and the increase in roads is inevitable for the smooth distribution of vehicles and logistics. In Korea, mountainous regions occupy 70% of the country, so tunnels are used to open roads. Without this, it is difficult to open the road. Currently, there are 3,720tunnels (as of December 31, 2023) installed on high-speed national highways, general national highways, and local roads nationwide, with a length of 2.499 and increasing every year. Accordingly, fire accidents in tunnels will also increase, and due to the nature of tunnel fire accidents, there is a high probability that they will escalate into large-scale disasters, resulting in casualties and property damage, as well as significant social losses due to the disruption of logistics transportation, etc. As the possibility of potential hazards is increasing, the purpose of this study is to build a safe and efficient tunnel system by optimizing maintenance and management for fire and disaster accidents in tunnels.

Towards a consistant safety format of steel beam-columns: application of the new interaction formulae for ambient temperature to elevated temperatures

  • Vila Real, P.M.M.;Lopes, N.;Simoes da Silva, L.;Piloto, P.;Franssen, J.M.
    • Steel and Composite Structures
    • /
    • v.3 no.6
    • /
    • pp.383-401
    • /
    • 2003
  • Two new formulae for the design of beam-columns at room temperature have been proposed into Eurocode 3, prEN 1993-1-1 (2002), and are the result of great efforts made by two working groups that followed different approaches, a French-Belgian team and an Austrian-German one. Under fire conditions the prEN 1993-1-2 (structural fire design) presents formulae, for the design of beam-columns based on the prENV 1993-1-1 (1992). In order to study the possibility of having, in part 1-1 and part 1-2 of the Eurocode 3, the same approach, a numerical research was made using the finite element program SAFIR, developed at the University of Liege for the study of structures subjected to fire.

An Experimental Study on the Fire Risk of Electric Heaters According to Contact of Flammable Materials (가연물 접촉에 따른 전기히터의 화재위험성에 관한 실험적 연구)

  • Lee, Sung-Ryong
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.63-71
    • /
    • 2011
  • In this study, it was evaluated the fire risk of an electric heater as representative seasonal appliances. Two type of electric heaters were used in experiments. When electric heaters were operated, temperature variation was measured around the heater. Internal structure was understood by Nondestructive inspection. It was evaluated the tire risk of electric heaters, when flammable materials were positioned ear a heater. It was also estimated the probability of a tire in case of malfunction of a safety tip-over witch. When a heater was operated in a normal condition, temperature was maintained under $80^{\circ}C$ around the heater. The possibility of a fire is very high, when a heater is covered with flammable materials or malfunction of safety parts (safety tip-over switch, anti-overheating devices).

A Research for Identification Method of Sprayed Fire-Resistive Material by Thermal Analysis (열분석을 통한 내화 뿜칠재 일치성분석 연구)

  • Cho, Nam-Wook;Rie, Dong-Ho;Shin, Hyun-Jun
    • Fire Science and Engineering
    • /
    • v.25 no.1
    • /
    • pp.7-12
    • /
    • 2011
  • As recent buildings are getting more high-rise and larger, steel structures, not a reinforced concrete structure, for columns and beams among the main structural members in a building are being widely used. Steels used for the main members of a building are constructed with a fire-resistive structure by applying them with fire-resistive coatings. The introduction of a simple test method that can verify the performance of fire-resistive material constructed on a site without conducting a fire-resistant test(real scale fire test) is needed and this study derived a site analysis method possible to make a rapid and scientific analysis through the analysis of components (instrumental analysis) concerning tire-resistive materials. the possibility of application of it in analyzing congruence over site construction materials by recognizing it as a standard material after securing an inherent fingerprint area of tire-resistive materials of which performance was verified in the concrete through thermal analysis was proved through experiments. This research result can be minimize of casualties, who is harmed to building collapse according to structures fire.

Consideration on Flash Fire of Fuel Tank by Plate and Projectile Impacts (외부위협체의 충돌에 의한 연료탱크의 순간화재 발생가능성에 대한 고찰)

  • Lee, Eun Min;Park, Ju Young;Lee, Hae Pyeong;Lee, Chang Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.62-67
    • /
    • 2014
  • This study was performed to analyze the vulnerability of the situation in which combat system is shot by external projectile impacts. In developing combat system, it is vital to consider the survivability as well as its mission capability because it is directly connected with loss of lives. Especially, when the parts which are susceptible to fire are shot under battle situation, the system is exposed to the dangerousness and the situation when the parts such as fuel tanks are impacted by external projectile impacts can lead to flash fire as a result of the leakage of fuel. Therefore, in this study the possibility of flash fire was calculated by analyzing a variety of variables supposing that fuel tank in the combat system is shot. The aim of this study is to suggest effective methods in the basic steps when combat system is designed.

A Study on Fire Safety of PASCON Cable Trough (PASCON 케이블 트로프의 화재안전성에 관한 연구)

  • 이창우;박재성;최충석;이의평;윤명오
    • Fire Science and Engineering
    • /
    • v.16 no.1
    • /
    • pp.51-59
    • /
    • 2002
  • Manifold physical properties of PASCON cable trough were evaluated, and its suitability of domestic test for flammability of plastic materials was examined. Particularly, suitability of PASCON material was investigated through study on the legal propriety of PASCON cable trough used for highspeed rail line and on a fire safety. As results, domestic test for flammability of PASCON cable trough material(KS M3015) was similar to UL 94 flammability testing and from the test outstanding capability of PASCON cable trough material was proved. Besides, possibility of fire enlargement would be very low in case of fire in PASCON cable trough installed around train express. Also, fire safety of PASCON cable trough was shown to be credible.

A Study on the Improvement of Performance Standard and Classification for the Firestop Accreditation System (내화충전구조 인정제도의 성능기준 및 등급분류 개선에 관한 연구)

  • Lee, H.D.;Choi, Y.J.;An, J.H.;Jeong, A.Y.;Seo, H.W.;Park, Jin O
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.4
    • /
    • pp.32-39
    • /
    • 2020
  • The fire compartments with fire-resistant construction are installed in the principal structural parts of a building in order to reduce damage in the event of a building fire. As a fire may spread through a crack in the fire compartment, the firestop with secured performance is used according to the procedure, methods, and standards specified in the detailed operation guideline. According to the current detailed operation guideline, vertical members (wall penetration) and horizontal members (floor penetration) are classified into different categories respective to each other for the classification of the firestop. Therefore, an accreditation applicant must apply for the performance test for each structure even if the wall and the floor have the same structure. Also, Grade T is used for the firestop that penetrates the fire compartment. However, in the case of foreign countries, the use of Grade F for the firestop is allowed even if it penetrates the fire compartment. The result of the precedent studies also showed that there was a significantly low possibility of fire to spread even if Grade F was applied for a metallic duct that penetrated the fire compartment. In this study, the improved scheme for the classification and performance standard of firestops was presented by analyzing the results of precedent studies regarding the firestop and domestic and overseas firestop qualification systems.