• 제목/요약/키워드: Possibility of a fire

검색결과 322건 처리시간 0.027초

전기화재 조기감지를 위한 화재감지알고리즘 연구 (A Study on the Fire Detection Algorithm for Early Fire Detection of Electrical Fire)

  • 이복영;박상태;홍성호;백동현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2164.1_2165.1
    • /
    • 2009
  • In this study we suggest fire detection algorithm using fuzzy inference with input variables of temperature and smoke density to detect electrical fire of early stage. The algorithm consists of membership function of temperature and smoke density and fire probability. The antecedent part of the algorithm consists of temperature and smoke density, and the consequent part consists of fire possibility. The inference rules of the algorithm is estimated to input temperature and smoke density obtained by real fire. With the help of algorithms using fuzzy inference we may be diagnose electrical fire precisely.

  • PDF

화열병(火熱病) 침구치료 시 적용 가능한 한방음악치료에 관한 연구 (The Study of Oriental Medicine Music Therapy Applied to the Acupuncture of Pathogenic Fire)

  • 김여진;이승현
    • Journal of Acupuncture Research
    • /
    • 제26권3호
    • /
    • pp.19-26
    • /
    • 2009
  • Objectives : The purpose of this study is to introduce oriental medicine music therapy during the acupuncture of pathogenic fire. Methods : We investigated the acupuncture points of pathogenic fire and the methodology of oriental medicine music therapy. Results : During the acupuncture of pathogenic fire, patients listen to proper music and after withdrawing of acupuncture, patients play the musical instrument. The patients with the case of fire due to affection by exopathogen, the method of dispelling superficial fire can be used through playing percussion instruments. The case of patients with the fire of five organ, the Five Phases music can be used properly. Conclusions : This study describes oriental medicine music therapy has a good possibility as a treatment of pathogenic fire with acupuncture.

  • PDF

아파트에 있어서의 피난사다리 도입 방안에 관한 연구 (A study for introduction plan of Evacuation Exit ladder in apartment)

  • 김태환
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.11-16
    • /
    • 2008
  • The trend of constructing skyscraper has arisen to the offistel and apartment complex due to the lack of exploitable land and urbanization. But, the phenomenon of the multi-story buildings is different from the regular building because of the possibility of mass disaster in fire. Therefore, Analyzing and comparing our actual condition and Japanese, It is going to be suggested that the introduction of fire escape ladder for residents in emergency.

  • PDF

선박의 거주구역 화재시 연기거동 및 온도변화에 관한 시뮬레이션 연구 (A Simulation Study on Distributions of Smoke and Temperature in Accommdation on Shipboard Fires)

  • 김원욱;김종수;오세진;김성환
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.293-294
    • /
    • 2006
  • This paper aims to simulate by FDS(Fire Dynamics Simulator) the distributions of temperature and smoke on fires in accommodations on boards. The paper focuses on analysis of temperature at fire occurrence and soot density. The purpose of this study is to predict the possibility of safe escape and efficient fire extinguishing method using fire simulation results.

  • PDF

THE INTEGRATION OF COMPONENTS OF FIRE TECHNOLOGY

  • Marchant, Eric W.
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.11-18
    • /
    • 1997
  • Fire safety systems in large buildings are likely to be complex and may be designed independently of other systems. This means that the interactions and interfaces between the fire safety systems and between the environmental control systems and the fire safety systems may not be carried out properly. Many large, recent buildings have many technological component systems that are used for the control of the environment within the building. Because of the "special" nature of the fire safety systems there is little consideration is given to the possibility systems with a dual function. However, many of the functions of fire safety systems are extensions of systems that provide the day to day control over the internal environment. The present world-wide trend towards the establishment of performance codes, and regulations, will enable the functional design of all systems and thereby allow closer integration of the "ordinary" and "special" systems. Some aspects of the functional and performance characteristics of systems in buildings are introduced and discussed. Special reference is made to the contributions of the systems to the minimisation of fire damage.e minimisation of fire damage.

  • PDF

초고강도 내화 콘크리트의 현장 적용을 위한 내화성능 평가에 관한 연구 (A Study on Fire Resistance Performance Evaluation for Field Application of Ultra-High Strength Concrete)

  • 백영운;육태원;박동수;김한솔;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.41-42
    • /
    • 2023
  • The physical performance of high-strength concrete deteriorates when exposed to high temperatures such as fire. In particular, in the case of ultra-high-strength concrete, there is a high possibility of explosion due to internal water pressure and thermal expansion due to the tight internal structure. In this paper, a fire resistance certification test was conducted for field application of ultra-high-strength fire-resistant concrete, and the fire resistance performance (temperature rise of main rebar) was compared according to the structural concrete cover thickness. As a result, when the covering thickness was 40 mm, three structures did not meet the certification standards, and when the covering thickness was 50 mm, all structures met the fire resistance certification standards.

  • PDF

도로터널 환기/제연 시스템 시뮬레이션 (A NUMERICAL STUDY OF THE VENTILATION AND FIRE SIMULATION IN A ROAD TUNNEL)

  • 박종택;원찬식;허남건;차철현
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 추계 학술대회논문집
    • /
    • pp.207-212
    • /
    • 2005
  • In designing a ventilation system of a road tunnel, a possibility of using the system as a smoke control system in case of a tunnel fire has to be considered. In the present study, a numerical simulation on ventilation system is performed considering jet fan operations and moving traffic. A fire-mode operation by reversing some fan operations in case of a tunnel fire is also simulated. The results show that ventilation operation can control the pollutants effectively, and fire-mode operation can control smoke and temperature effectively to prevent a disaster.

  • PDF

가상현실 기반 도로터널 화재체험 시뮬레이터 개발 (Development of virtual reality based simulator for road tunnel fire-training)

  • 한용식;최병일;김명배;차무현;김병수
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.214-217
    • /
    • 2008
  • An fire simulator has been developed for examining possibility of future engineering applications in the fire research field. This system composed of workstation on XP OS and HMD(Head Mounted Display) and visualized 3D walk-through type virtual reality graphics inside a tunnel in case of fire. By using a joystick and a viewpoint tracer, subjects can be experience interactive changes occurred both in graphics and surrounding sound.

  • PDF

구조용 압연강(SS 400)의 고온 기계적 특성을 이용한 기둥부재의 내화성능 평가 (Evaluation of Fire Resistance Using Mechanical Properties at High Temperature for Steel Column Made of Rolled Steels (SS 400))

  • 권인규;신순기
    • 대한금속재료학회지
    • /
    • 제49권9호
    • /
    • pp.671-677
    • /
    • 2011
  • Steel columns used in steel buildings are inclined to lose their strength when exposed to severe fire conditions, so fire resistance is required in most countries to protect against loss of life and building collapses. In Korea, the fire resistance of columns can be obtained by the fire test defined in KS F 2257-1, 7. The fire resistance of a steel column should be evaluated in terms of the column's conditions, such as various section types (H-section, hollow-section), the column's length and boundary conditions, and whether it is fixed or hinged. However, fire testing of steel columns is usually conducted on one standard-sized H-section over 3,000 mm, and the result is used as the column's fire resistance. This is not a reasonable way to ensure that a building can withstand fire conditions. In this study, to evaluate the possibility of calculating the fire resistance of steel columns with material properties of high tensile strength of SS 400, both load-bearing fire tests and calculation of steel temperatures were carried out. The results of temperature calculation were very similar to those obtained by fire test.

시뮬레이션을 이용한 철도터널 화재 사고의 승객 안전도 분석 (A Study on Analysis of Passenger Safety in Railroad Tunnel Fire - Using Simulation -)

  • 김동진;문성암;김동건;김경섭;장용준;정우성
    • 한국철도학회논문집
    • /
    • 제10권2호
    • /
    • pp.131-136
    • /
    • 2007
  • In this paper, the methodology to predict the number of deaths and possible fire propagation scenarios will be described in case of fire on a train in a tunnel. We use a probabilistic analysis method for the evaluation of possibility for each scenario and the deaths tolls are calculated with the help of the passenger evacuation simulation program. The resulting safety of passengers is displayed on a F/N graph, which could be used in part as a guideline to predict the safety level of the tunnel in fire.