• Title/Summary/Keyword: Positron emission tomography (PET)

Search Result 474, Processing Time 0.029 seconds

Assessment of Bone Metastasis using Nuclear Medicine Imaging in Breast Cancer : Comparison between PET/CT and Bone Scan (유방암 환자에서 골전이에 대한 핵의학적 평가)

  • Cho, Dae-Hyoun;Ahn, Byeong-Cheol;Kang, Sung-Min;Seo, Ji-Hyoung;Bae, Jin-Ho;Lee, Sang-Woo;Jeong, Jin-Hyang;Yoo, Jeong-Soo;Park, Ho-Young;Lee, Jae-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.1
    • /
    • pp.30-41
    • /
    • 2007
  • Purpose: Bone metastasis in breast cancer patients are usually assessed by conventional Tc-99m methylene diphosphonate whole-body bone scan, which has a high sensitivity but a poor specificity. However, positron emission tomography with $^{18}F-2-deoxyglucose$ (FDG-PET) can offer superior spatial resolution and improved specificity. FDG-PET/CT can offer more information to assess bone metastasis than PET alone, by giving a anatomical information of non-enhanced CT image. We attempted to evaluate the usefulness of FDG-PET/CT for detecting bone metastasis in breast cancer and to compare FDG-PET/CT results with bone scan findings. Materials and Methods: The study group comprised 157 women patients (range: $28{\sim}78$ years old, $mean{\pm}SD=49.5{\pm}8.5$) with biopsy-proven breast cancer who underwent bone scan and FDG-PET/CT within 1 week interval. The final diagnosis of bone metastasis was established by histopathological findings, radiological correlation, or clinical follow-up. Bone scan was acquired over 4 hours after administration of 740 MBq Tc-99m MDP. Bone scan image was interpreted as normal, low, intermediate or high probability for osseous metastasis. FDG PET/CT was performed after 6 hours fasting. 370 MBq F-18 FDG was administered intravenously 1 hour before imaging. PET data was obtained by 3D mode and CT data, used as transmission correction database, was acquired during shallow respiration. PET images were evaluated by visual interpretation, and quantification of FDG accumulation in bone lesion was performed by maximal SUV(SUVmax) and relative SUV(SUVrel). Results: Six patients(4.4%) showed metastatic bone lesions. Four(66.6%) of 6 patients with osseous metastasis was detected by bone scan and all 6 patients(100%) were detected by PET/CT. A total of 135 bone lesions found on either FDG-PET or bone scan were consist of 108 osseous metastatic lesion and 27 benign bone lesions. Osseous metastatic lesion had higher SUVmax and SUVrel compared to benign bone lesion($4.79{\pm}3.32$ vs $1.45{\pm}0.44$, p=0.000, $3.08{\pm}2.85$ vs $0.30{\pm}0.43$, p=0.000). Among 108 osseous metastatic lesions, 76 lesions showed as abnormal uptake on bone scan, and 76 lesions also showed as increased FDG uptake on PET/CT scan. There was good agreement between FDG uptake and abnormal bone scan finding (Kendall tau-b : 0.689, p=0.000). Lesion showed increased bone tracer uptake had higher SUVmax and SUVrel compared to lesion showed no abnormal bone scan finding ($6.03{\pm}3.12$ vs $1.09{\pm}1.49$, p=0.000, $4.76{\pm}3.31$ vs $1.29{\pm}0.92$, p=0.000). The order of frequency of osseous metastatic site was vertebra, pelvis, rib, skull, sternum, scapula, femur, clavicle, and humerus. Metastatic lesion on skull had highest SUVmax and metastatic lesion on rib had highest SUVrel. Osteosclerotic metastatic lesion had lowest SUVmax and SUVrel. Conclusion: These results suggest that FDG-PET/CT is more sensitive to detect breast cancer patients with osseous metastasis. CT scan must be reviewed cautiously skeleton with bone window, because osteosclerotic metastatic lesion did not showed abnormal FDG accumulation frequently.

Small Animal PET Imaging with [$^{124}I$]FIAU for Herpes Simplex Virus Type 1 Thymidine Kinase Gene Expression in a Hepatoma Model (간암 동물 모델에서 2'-fluoro-2'-deoxy-1-${\beta}$-D-arabinofuranosyl-5-[$^{124}I$iodo-uracil ($[^{124}I]FIAU$) 소동물 PET 영상 연구)

  • Chae, Min-Jeong;Lee, Tae-Sup;Kim, June-Youp;Woo, Gwang-Sun;Jumg, Wee-Sup;Chun, Kwon-Soo;Kim, Jae-Hong;Lee, Ji-Sup;Ryu, Jin-Sook;Cheon, Gi-Jeong;Choi, Chang-Woon;Lim, Sang-Moo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.3
    • /
    • pp.235-245
    • /
    • 2008
  • Purpose: The HSV1-tk gene has been extensively studied as a type of reporter gene. In hepatocellular carcinoma (HCC), only a small proportion of patients are eligible for surgical resection and there is limitation in palliative options. Therefore, there is a need for the development of new treatment modalities and gene therapy is a leading candidate. In the present study, we investigated the usefulness of substrate, 2'-fluoro-2'-deoxy-1-${\beta}$-D-arabino-furanosyi-5-[$^{124/125}I$]iodo- uracil ([$I^{124/125}I$]FIAU) as a non-invasive imaging agent for HSV1-tk gene therapy in hepatoma model using small animal PET. Material and Methods: With the Morris hepatoma MCA cell line and MCA-tk cell line which was transduced with the HSV1-tk gene, in vitro uptake and correlation study between [$^{125}I$]FIAU uptake according to increasing numeric count of percentage of MCA-tk cell were performed. The biodistribution data and small animal PET images with [$^{124}I$]FIAU were obtained with Balb/c-nude mice bearing both MCA and MCA-tk tumors. Results:, Specific accumulation of [[$^{125}I$]FIAU was observed in MCA-tk cells but uptake was low in MCA cells. Uptake in MCA-tk cells was 15 times higher than that of MCA cells at 480 min. [$^{125}I$]FIAU uptake was linearly correlated (R2 =0.964, p =0.01) with increasing percentage of MCA-tk numeric cell count. Biodistribution results showed that [$^{125}I$]FIAU was mainly excreted via the renal system in the early phase. Ratios of MCA-tk tumor to blood acting were 10, 41, and 641 at 1 h, 4 h, and 24 h post-injection, respectively. The maximum ratio of MCA-tk to MCA tumor was 192.7 at 24 h. Ratios of MCA-tk tumor to liver were 13.8, 66.8, and 588.3 at 1 h, 4 h, and 24 h, respectively. On small animal PET, [$^{124}I$]FIAU accumulated in substantial higher levels in MCA-tk tumor and liver than MCA tumor. Conclusion: FIAU shows selective accumulation to HSV1-tk expressing hepatoma cell tumors with minimal uptake in normal liver. Therefore, radiolabelled FIAU is expected to be a useful substrate for non-invasive imaging of HSV1-tk gene therapy and therapeutic response monitoring of HCC.

A Study of Decrease Exposure Dose for the Radiotechnologist in PET/CT (PET-CT 검사에서 방사선 종사자 피폭선량 저감에 대한 방안 연구)

  • Kim, Bit-Na;Cho, Suk Won;Lee, Juyoung;Lyu, Kwang Yeul;Park, Hoon-Hee
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.23-30
    • /
    • 2015
  • Positron emission tomography scan has been growing diagnostic equipment in the development of medical imaging system. Compare to 99mTc emitting 140 keV, Positron emission radionuclide emits 511 keV gamma rays. Because of this high energy, it needs to reduce radioactive emitting from patients for radio technologist. We searched the external dose rates by changing distance from patients and measure the external dose rates when we used shielder investigate change external dose rates. In this study, the external dose distribution were analyzed in order to help managing radiation protection of radio technologists. Ten patients were searched (mean age: $47.7{\pm}6.6$, mean height: $165.5{\pm}3.8cm$, mean weight: $65.9{\pm}1.4kg$). Radiation was measured on the location of head, chest, abdomen, knees and toes at the distance of 10, 50, 100, 150, and 200 cm, respectively. Then, all the procedure was given with a portable radiation shielding on the location of head, chest, and abdomen at the distance of 100, 150, and 200 cm and transmittance was calculated. In 10 cm, head ($105.40{\mu}Sv/h$) was the highest and foot($15.85{\mu}Sv/h$) was the lowest. In 200 cm, head, chest, and abdomen showed similar. On head, the measured dose rates were $9.56{\mu}Sv/h$, $5.23{\mu}Sv/h$, and $3.40{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.24{\mu}Sv/h$, $1.67{\mu}Sv/h$, and $1.27{\mu}Sv/h$ in 100, 150, and 200 cm on head. On chest, the measured dose rates were $8.54{\mu}Sv/h$, $4.90{\mu}Sv/h$, $3.44{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.27{\mu}Sv/h$, $1.34{\mu}Sv/h$, and $1.13{\mu}Sv/h$ in 100, 150, and 200 cm on chest. On abdomen, the measured dose rates were $9.83{\mu}Sv/h$, $5.15{\mu}Sv/h$, and $3.18{\mu}Sv/h$ in 100, 150, and 200 cm, respectively. When using shielder, it shows $2.60{\mu}Sv/h$, $1.75{\mu}Sv/h$, and $1.23{\mu}Sv/h$ in 100, 150, and 200 cm on abdomen. Transmittance was increased as the distance was expanded. As the distance was further, the radiation dose were reduced. When using shielder, the dose were reduced as one-forth of without shielder. The Radio technologists are exposed of radioactivity and there were limitations on reducing the distance with Therefore, the proper shielding will be able to decrease radiation dose to the technologists.

Assessment of Metabolic Impairment in Alzheimer's Disease with [$^{18}F$]FDG PET: Validity and Role of Simplified Tissue Radioactivity Ratio Analysis (알쯔하이머병에서 양전자방출단층촬영을 이용한 국소뇌포도당대사의 변화에 관한 연구)

  • Kim, Sang-Eun;Na Duk-Lyul;Lee, Jeong-Rim;Choi, Yong;Lee, Kyung-Han;Choe Yearn-Seong;Kim, Doh-Kwan;Kim, Byung-Tae;Lee, Kwang-Ho;Kim, Seung-Tai P.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.3
    • /
    • pp.299-314
    • /
    • 1996
  • The purpose of the present study was to validate the use of tissue radioactivity ratios instead of regional metabolic rates for the assessment of regional metabolic changes in Alzheimer's disease(AD) with [$^{18}F$]FDG PET and to examine the correlation of ratio indices with the severity of cognitive impairment in AD. Thirty-seven AD Patients(age $68{\pm}9 yrs$, $mean{\pm}s.d.$; 36 probable and 1 definite AD), 28 patients with dementia of non-Alzheimer type(age $66{\pm}7 yrs$), and 17 healthy controls(age $66{\pm}4 yrs$) underwent [$^{18}F$]FDG PET imaging. Two simplified radioactivity ratio indices were calculated from 37-66 min image: region-to-cerebellar radioactivity ratio(RCR) and a composite radioactivity ratio(a ratio of radioactivity in the most typically affected regions over the least typically affected regions: CRR). Local cerebral metabolic rate for glucose(LCMRglu) was also measured using a three-compartment, five-parameter tracer kinetic model. The ratio indices were significantly lower in AD patients than in controls(RCR in temporoparietal cortex, $0.949{\pm}0.136$ vs. $1.238{\pm}0.129$, p=0.0004; RCR in frontal cortex, $1.027{\pm}0.128$ vs. $1.361{\pm}0.151$, p<0.0001; CRR, $0.886{\pm}0.096$ vs. $1.032{\pm}0.042$. p=0.0024). On the RCR analysis, 86% of AD patients showed a pattern of bilateral temporoparietal hypometabolism with or without frontal involvement; hypometabolism was unilateral in 11% of the patients. When bilateral temporoparietal hypometabolism was considered to be suggestive of AD, the sensitivity and specificity of the RCR analysis for the differential diagnosis of AD were 86% and 73%, respectively. The RCR was correlated significantly with the macroparameter K [$K_1k_3/(k_2+k_3)$] (r=0.775, p<0.0001) and LCMRglu(r=0.633, p=0.0002) measured using the kinetic model. In patients with AD, both average RCR of cortical association areas and CRR were correlated with Mini-Mental Status Examination(r=0.565, p=0.0145; r=0.642, p=0.0031, respectively), Clinical Dementia Rating(r=-0.576, p=0.0124; r=-0.591, p=0.0077), and total score of Mattis Dementia Rating Scale (r=0.574, p=0.0648; r=0.737, p=0.0096). There were also significant correlations between memory and language impairments and corresponding regional RCRs. The results suggest that the [$^{18}F$]FDG PET ratio indices, RCR and CRR, reflect global and regional metabolic rates and correlate with the severity of cognitive impairment in AD. The simplified ratio analysis may be clinically useful for the differential diagnosis and serial monitoring of the disease.

  • PDF

The Heterogeneity of Flow Distribution and Partition Coefficient in [15O-H2O] Myocardium Positron Emission Tomography ([15O-H2O] 심근 양전자 단층 촬영에서 혈류 분포의 비균일성과 분배계수)

  • Ahn, Ji Young;Lee, Dong Soo;Kim, Kyung Min;Jeong, Jae Min;Chung, June-Key;Shin, Seung-Ae;Lee, Myung Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.1
    • /
    • pp.32-49
    • /
    • 1998
  • For estimation of regional myocardial blood flow with O-15 water PET, a few modifications considering partial volume effect based on single compartment model have been proposed. In this study, we attempted to quantify the degree of heterogeneity and to show the effect of tissue flow heterogeneity on partition coefficient(${\lambda}$) and to find the relation between perfusable tissue index(PTI) and ${\lambda}$ by computer simulation using two modified models. We simulated tissue curves for the regions with homogeneous and heterogeneous blood flow over a various flow range(0.2-4.0ml/g/min). Simulated heterogeneous tissue composed of 4 subregions of the same or different size of block which have different homogeneous flow and different degree of slope of distribution of blood flow. We measured the index representing heterogeneity of distribution of blood flow for each heterogeneous tissue by the constitution heterogeneity(CH). For model I, we assumed that tissue recovery coefficient ($F_{MME}$) was the product of partial volume effect($F_{MMF}$) and PTI. Using model I, PTI, flow, and $F_{MM}$ were estimated. For model II, we assumed that partition coefficient was another variable which could represent tissue characteristics of heterogeneity of flow distribution. Using model II, PTI, flow and ${\lambda}$ were estimated. For the simulated tissue with homogeneous flow, both models gave exactly the same estimates, of three parameters. For the simulated tissue with heterogeneous flow distribution, in model I, flow and $F_{MM}$ were correctly estimated as CH was increased moderately. In model II, flow and ${\lambda}$ were decreased curvi-linearly as CH was increased. The degree of underestimation of ${\lambda}$ obtained using model II, was correlated with CH. The degree of underestimation of flow was dependent on the degree of underestimation of ${\lambda}$. PTI was somewhat overestimated and did not change according to CH. We conclude that estimated ${\lambda}$ reflect the degree of tissue heterogeneity of flow distribution. We could use the degree of underestimation of ${\lambda}$ to find the characteristic heterogeneity of tissue flow and use ${\lambda}$ to recover the underestimated flow.

  • PDF

Functional Brain Mapping Using $H_2^{15}O$ Positron Emission Tomography ( I ): Statistical Parametric Mapping Method ($H_2^{15}O$ 양전자단층촬영술을 이용한 뇌기능 지도 작성(I): 통계적 파라메터 지도작성법)

  • Lee, Dong-Soo;Lee, Jae-Sung;Kim, Kyeong-Min;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.3
    • /
    • pp.225-237
    • /
    • 1998
  • Purpose: We investigated the statistical methods to compose the functional brain map of human working memory and the principal factors that have an effect on the methods for localization. Materials and Methods: Repeated PET scans with successive four tasks, which consist of one control and three different activation tasks, were performed on six right-handed normal volunteers for 2 minutes after bolus injections of 925 MBq $H_2^{15}O$ at the intervals of 30 minutes. Image data were analyzed using SPM96 (Statistical Parametric Mapping) implemented with Matlab (Mathworks Inc., U.S.A.). Images from the same subject were spatially registered and were normalized using linear and nonlinear transformation methods. Significant difference between control and each activation state was estimated at every voxel based on the general linear model. Differences of global counts were removed using analysis of covariance (ANCOVA) with global activity as covariate. Using the mean and variance for each condition which was adjusted using ANCOVA, t-statistics was performed on every voxel To interpret the results more easily, t-values were transformed to the standard Gaussian distribution (Z-score). Results: All the subjects carried out the activation and control tests successfully. Average rate of correct answers was 95%. The numbers of activated blobs were 4 for verbal memory I, 9 for verbal memory II, 9 for visual memory, and 6 for conjunctive activation of these three tasks. The verbal working memory activates predominantly left-sided structures, and the visual memory activates the right hemisphere. Conclusion: We conclude that rCBF PET imaging and statistical parametric mapping method were useful in the localization of the brain regions for verbal and visual working memory.

  • PDF

Radiolabeling of 11C-sertraline by fast and easy loop method with [11C]CH3OTf

  • Lee, Hak Jeong;Jeong, Jae Min;Lee, Sang-Yoon;Ido, Tatsuo
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.3 no.1
    • /
    • pp.32-37
    • /
    • 2017
  • Cis-(1S,4S)-4-(3,4-dichlorophenyl)-1,2,3,4-tertrahydro-N-methyl-1-naphthalenamine (sertraline) hydrochloride from among selective serotonin reuptake inhibitors (SSRIs) is a treatment of major depression. For the differential diagnosis by metabolizing serotonin in a patient with neurological disorders, the radiolabeled $^{11}C$-sertraline was developed for non-invasive positron emission tomography in living brain and use the evaluation of new drug for SSRIs. We release the results of a fast and easy radiolabeling method applied a one-step loop method with $[^{11}C]CH_3OTf$ for routine clinical applications of $^{11}C$-sertraline. 1 mg of a precursor for $^{11}C$-sertraline in 0.1 mL DMF and $5{\mu}L$ of 1N NaOH, were injected into the loop of semi-prep high-performance liquid chromatography (HPLC). $[^{11}C]CH_3OTf$ was passed through the loop at room temperature (RT). The $^{11}C$-sertraline was separated by the semi-preparative HPLC. $^{11}C$-sertraline was eluted at 28.0 min was collected and evaluated by analytical HPLC and mass spectrometer. The total radiolabeling efficiency of $^{11}C$-sertraline was $30.7{\pm}8.7%$. The specific activity was $64.8{\pm}51.4GBq/{\mu}mol$. The radiochemical and chemical purities were higher than 99%. The mass spectrum of the product showed m/z peaks at 307.1 (M+1), indicating the mass of sertraline. By the one-step loop method with $[^{11}C]CH_3OTf$, $^{11}C$-sertraline could be quickly and easily prepared for clinical application.

Protective Effect of Soybean-Derived Phosphatidylserine on the Trimethyltin-Induced Learning and Memory Deficits in Rats

  • An, Yong Ho;Park, Hyun Jung;Shim, Hyun Soo;Choe, Yun Seok;Han, Jeong Jun;Kim, Jin Su;Lee, Hye Jung;Shim, Insop
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.28 no.3
    • /
    • pp.337-345
    • /
    • 2014
  • The present study examined the effects of soybean-derived phosphatidylserine (SB-PS) on the learning and memory function and the neural activity in rats with trimethyltin (TMT)-induced memory deficits. The cognitive improving efficacy of SB-PS on the amnesic rats, which was induced by TMT, was investigated by assessing the Morris water maze test and by performing cholineacetyl transferase (ChAT), acetylcholinesterase (AChE) and cAMP responsive element binding protein (CREB) immunohistochemistry. A positron emission tomography (PET) scanning the rat brain was by performed administer 18F-Fluorodeoxy-glucose (18F-FDG). The rats with TMT injection showed impaired learning and memory of the tasks and treatment with SB-PS produced a significant improvement of the escape latency to find the platform in the Morris water maze at the 2nd day compared to that of the MCT group. In the retention test, the SB-PS group showed increased time spent around the platform compared to that of the MCT group. Consistent with the behavioral data, SB-PS 50 group significantly alleviated the loss of acetyl cholinergic neurons in the hippocampus compared to that of the MCT group. Treatment with SB-PS significantly increased the CREB positive neurons in the hippocampus as compared to that of the MCT group. In addition, SB-PS groups increased the glucose uptake in the hippocampus and SB-PS 50 group increased the glucose uptake in the frontal lobe, as compared to that of the MCT group. These results suggest that SB-PS may be useful for improving the cognitive function via regulation of cholinergic marker enzyme activity and neural activity.

A Case of Bronchiectasis with Elevated Serum CA 125 Level (혈중 CA 125 수치가 지속적으로 상승되었던 기관지확장증 1예)

  • Shin, Bong Chul;Koo, Tae Hyoung;Kim, Sang Ock;Ter, Hsing Chien;Um, Soo Jung;Lee, Soo-Keol;Son, Choon Hee;Kim, Ki Nam;Lee, Ki-Nam;Roh, Mee Sook;Choi, Pil Jo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.66 no.6
    • /
    • pp.467-470
    • /
    • 2009
  • Serum CA 125 is the most useful marker for monitoring patients with epithelial ovarian cancer. However, it can be elevated above normal level in a variety of conditions other than ovarian cancer such as endometriosis, pelvic inflammation disease, and other malignant or nonmalignant disorders, including pulmonary diseases. Recently, we experienced a case of bronchiectasis in which the serum CA 125 level was elevated, changing with the patient's condition. There was no evidence of underlying malignant disease on positron emission tomography or on gynecologic examination, including transvaginal ultrasonography. During follow-up for 14 months, we could not find any clue of malignant disease that could have been the cause of the elevated levels of serum CA 125. Elevated serum CA 125 level should be interpreted carefully according to the patient's clinical condition. In addition, our case suggests that CA 125 may be used as a surrogate marker for acute inflammatory status for chronic pulmonary diseases.

Development and optimization of C-11 gas target system in KOTRON-13 cyclotron (KOTRON-13 사이클로트론의 고효율C-11 가스 표적장치)

  • Lee, Hong-Jin;Lee, Won-Kyeong;Park, Jun-Hyung;Moon, Byung-Seok;Lee, In-Won;Chae, Sung-Ki;Lee, Byung-Chul;Kim, Sang-Eun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.86-89
    • /
    • 2011
  • Purpose: The KOTRON-13 cyclotron was developed in South Korea and was introduced to regional cyclotron centers to produce short-lifetime medical radioisotopes. However, this cyclotron has limited capacity to produce carbon-11 isotope so far. We herein study how to develop and optimize an effective carbon-11 target system in the KOTRON-13 cyclotron by changing cooling system, combing with fluorine-18 target and evaluating beam currents. Materials and Method: To develop the optimal carbon-11 target and an effective cooling system, we designed the carbon-11 target system by Stopping and Range of Ions in Matter (SRIM) simulation program and considered the cavity pressure during irradiation at target grid. In this investigation, we evaluated the yield of carbon-11 production at different beam currents and the stability of the operation of the KOTRON-13 cyclotron. Results: The production of carbon-11 was enhanced from about 1.700 mCi ($50{\mu}A$) to 2,000 mCi ($60{\mu}A$) on the carbon-11 target which developed by seoul national university bundang hospital (SNUBH) and Samyoung Unitech. Additionally, the cooling condition was showed stable to produce carbon-11 under high beam current. Conclude: The carbon-11 target system of the KOTRON-13 cyclotron was successfully developed and improved carbon-11 production. Consequently, the operation of carbon-11 target system was highly effective and stable compare with other commercial cyclotrons. Our results are believed that this optimal carbon-11 target system will be helpful for the routine carbon-11 production in the KOTRON-13 cyclotron.

  • PDF