• Title/Summary/Keyword: Positron Emission Tomography Computed Tomography

Search Result 257, Processing Time 0.028 seconds

Development of Supplemental Equipment to Reduce Movement During Fusion Image Acquisition (융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발)

  • Cho, Yong Gwi;Pyo, Sung Jae;Kim, Bong Su;Shin, Chae Ho;Cho, Jin Woo;Kim, Chang Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.84-89
    • /
    • 2013
  • Purpose: Patients' movement during long image acquisition time for the fusion image of PET-CT (Positron Emission Tomography-Computed Tomography) results in unconformity, and greatly affects the quality of the image and diagnosis. The arm support fixtures provided by medical device companies are not manufactured considering the convenience and safety of the patients; the arm and head movements (horizontal and vertical) during PET/CT scan cause defects in the brain fundus images and often require retaking. Therefore, this study aims to develop patient-compensation device that would minimize the head and arm movements during PET/CT scan, providing comfort and safety, and to reduce retaking. Materials and Methods: From June to July 2012, 20 patients who had no movement-related problems and another 20 patients who had difficulties in raising arms due to shoulder pain were recruited among the ones who visited nuclear medicine department for PET Torso scan. By using Patient Holding System (PHS), different range of motion (ROM) in the arm ($25^{\circ}$, $27^{\circ}$, $29^{\circ}$, $31^{\circ}$, $33^{\circ}$, $35^{\circ}$) was applied to find the most comfortable angle and posture. The manufacturing company was investigated for the permeability of the support material, and the comfort level of applying bands (velcro type) to fix the patient's head and arms was evaluated. To find out the retake frequency due to movements, the amount of retake cases pre/post patient-compensation were analyzed using the PET Torso scan data collected between January to December 2012. Results: Among the patients without movement disorder, 18 answered that PHS and $29^{\circ}$ arm ROM were the most comfortable, and 2 answered $27^{\circ}$ and $31^{\circ}$, respectively. Among the patients with shoulder pain, 15 picked $31^{\circ}$ as the most comfortable angle, 2 picked $33^{\circ}$, and 3 picked $35^{\circ}$. For this study, the handle was manufactured to be adjustable for vertical movements. The material permeability of the patient-compensation device has been verified, and PHS and the compensation device were band-fixed (velcro type) to prevent device movements. A furrow was cut for head fixation to minimize the head and neck movements, fixing bands were attached for the head, wrist, forearm, and upper arm to limit movements. The retake frequency of PET Torso scan due to patient movements was 11.06% (191 cases/1,808 patients) before using the movement control device, and 2.65% (48 cases/1,732 patients) after using the device; 8.41% of the frequency was reduced. Conclusion: Recent change and innovation in the medical environment are making expensive medical image scans, and providing differentiated services for the customers is essential. To secure patient comfort and safety during PET/CT scans, ergonomic patient-compensation devices need to be provided. Therefore, this study manufactured a patientcompensation device with vertically adjustable ergonomic ROM according to the patient's body shape and condition during PET Torso scan. The defects in the basal ganglia images due to arm movements were reduced, and retaking was decreased.

  • PDF

The Effect of PET/CT Images on SUV with the Correction of CT Image by Using Contrast Media (PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향)

  • Ahn, Sha-Ron;Park, Hoon-Hee;Park, Min-Soo;Lee, Seung-Jae;Oh, Shin-Hyun;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.77-81
    • /
    • 2009
  • Purpose: The PET of the PET/CT (Positron Emission Tomography/Computed Tomography) quantitatively shows the biological and chemical information of the body, but has limitation of presenting the clear anatomic structure. Thus combining the PET with CT, it is not only possible to offer the higher resolution but also effectively shorten the scanning time and reduce the noises by using CT data in attenuation correction. And because, at the CT scanning, the contrast media makes it easy to determine a exact range of the lesion and distinguish the normal organs, there is a certain increase in the use of it. However, in the case of using the contrast media, it affects semi-quantitative measures of the PET/CT images. In this study, therefore, we will be to establish the reliability of the SUV (Standardized Uptake Value) with CT data correction so that it can help more accurate diagnosis. Materials and Methods: In this experiment, a total of 30 people are targeted - age range: from 27 to 72, average age : 49.6 - and DSTe (General Electric Healthcare, Milwaukee, MI, USA) is used for equipment. $^{18}F$- FDG 370~555 MBq is injected into the subjects depending on their weight and, after about 60 minutes of their stable position, a whole-body scan is taken. The CT scan is set to 140 kV and 210 mA, and the injected amount of the contrast media is 2 cc per 1 kg of the patients' weight. With the raw data from the scan, we obtain a image showing the effect of the contrast media through the attenuation correction by both of the corrected and uncorrected CT data. Then we mark out ROI (Region of Interest) in each area to measure SUV and analyze the difference. Results: According to the analysis, the SUV is decreased in the liver and heart which have more bloodstream than the others, because of the contrast media correction. On the other hand, there is no difference in the lungs. Conclusions: Whereas the CT scan images with the contrast media from the PET/CT increase the contrast of the targeted region for the test so that it can improve efficiency of diagnosis, there occurred an increase of SUV, a semi-quantitative analytical method. In this research, we measure the variation of SUV through the correction of the influence of contrast media and compare the differences. As we revise the SUV which is increasing in the image with attenuation correction by using contrast media, we can expect anatomical images of high-resolution. Furthermore, it is considered that through this trusted semi-quantitative method, it will definitely enhance the diagnostic value.

  • PDF

A Case of Multifocal Tuberculosis Mimicking Metastatic Malignancy (전이암으로 오인된 다원성(multifocal) 결핵 1예)

  • Cho, In Jeong;Im, So Yeon;Chun, Eun Mi;Ryu, Yon Ju;Lee, Jin Hwa;Sim, Yun Su;Jang, Jung Hyun;Shim, Sung Shin;Bae, Jung Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.2
    • /
    • pp.173-177
    • /
    • 2007
  • Tuberculosis remains as a major public health problem worldwide. In addition to classic pulmonary tuberculosis, tuberculosis may sometimes present atypically. In the case of atypical tuberculosis, the unusual sites and properties that mimic other diseases can lead to a misdiagnosis and therapeutic delay. Abdominal and pharyngeal tuberculosis are uncommon extrapulmonary manifestations of tuberculosis. To the best of our knowledge, a combination of abdominal and pharyngeal tuberculosis with endobronchial tuberculosis has not been reported. We report a case of concurrent abdominal and pharyngeal tuberculosis in a patient with chronic endobronchial tuberculosis mimicking a metastatic malignancy on computed tomography and FDG-PET.

A Case of Paraneoplastic Limbic Encephalitis Associated with Small Cell Lung Cancer

  • Ryu, Ja Young;Lee, Seung Hyeun;Lee, Eun Joo;Min, Kyung Hoon;Hur, Gyu Young;Lee, Sung Yong;Kim, Je Hyeong;Lee, Sang Yeub;Shin, Chol;Shim, Jae Jeong;In, Kwang Ho;Kang, Kyung Ho;Yoo, Se Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.73 no.5
    • /
    • pp.273-277
    • /
    • 2012
  • Paraneoplastic limbic encephalitis (PLE) is a rare syndrome characterized by memory impairment, affective and behavioral disturbances and seizures. Among many different neoplasms known to cause PLE, small cell lung cancer (SCLC) is the most frequently reported. The pathogenesis is not fully understood but is believed to be autoimmune-related. We experienced a patient with typical clinical features of PLE. A 67-year-old man presented with seizure and disorientation. Brain magnetic resonance imaging demonstrated high signal intensity in the bilateral amygdala and hippocampus in flair and T2-weighted images suggestive of limbic encephalitis. Cerebrospinal fluid tapping revealed no evidence of malignant cells or infection. Positron emission tomography/computed tomography showed a lung mass with pleural effusion and a consequent biopsy confirmed the diagnosis of PLE associated with SCLC. The patient was subsequently treated with chemotherapy and neurologic symptoms gradually improved.

The Effect of Metallic Dental Implant on Positron Emission Tomography Computed Tomography Image (금속성 치아충전물이 PET/CT영상이 미치는 영향)

  • Kim, Ki-Jin;Bae, Seok-Hwan;Han, Sang-Hyun;Yu, Se-Jong;Lee, Bo-Woo
    • Journal of Digital Convergence
    • /
    • v.10 no.2
    • /
    • pp.243-247
    • /
    • 2012
  • Beam hardening artifact happens in the CT image. when a PET/CT is conducted while there is a metallic dental implant. The artifact appears in the CT image can affect the PET image. When the patient with head and neck cancer has a metallic dental implant, Beam hardening artifact which was taken in th CT image can change the PET image and SUV value. Therefore, by Quantitative measure of the SUV according to the change in HU by the metallic dental implant, the appropriacy in the clinical application was assessed. The records of 47 patients with PET/CT August 2011. For the analysis, 2 region of interest were defined in area where CT and PET image. As a result of the experiment, if there in an implant, the HU and the SUV increased and there existed a statistically significant difference(p<0.01). Although this level of increase was not large compared with that in the patient who have no metallic dental implant, when a person has head and neck cancer, it is even more likely to be overestimated when diagnosing the cancer. When conducting PET/CT for the patient who have head and neck cancer, the physical biological parts should be considered in order not to make an error in decoding.

Clinical outcomes of adjuvant radiation therapy and prognostic factors in early stage uterine cervical cancer

  • Kim, Hyun Ju;Rhee, Woo Joong;Choi, Seo Hee;Nam, Eun Ji;Kim, Sang Wun;Kim, Sunghoon;Kim, Young Tae;Kim, Gwi Eon;Kim, Yong Bae
    • Radiation Oncology Journal
    • /
    • v.33 no.2
    • /
    • pp.126-133
    • /
    • 2015
  • Purpose: To evaluate the outcomes of adjuvant radiotherapy (RT) and to analyze prognostic factors of survival in the International Federation of Gynecology and Obstetrics (FIGO) IB-IIA uterine cervical cancer. Materials and Methods: We retrospectively reviewed the medical records of 148 patients with FIGO IB-IIA uterine cervical cancer who underwent surgery followed by adjuvant RT at the Yonsei Cancer Center between June 1997 and December 2011. Adjuvant radiotherapy was delivered to the whole pelvis or an extended field with or without brachytherapy. Among all patients, 57 (38.5%) received adjuvant chemotherapy either concurrently or sequentially. To analyze prognostic factors, we assessed clinicopathologic variables and metabolic parameters measured on preoperative 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT). To evaluate the predictive performance of metabolic parameters, receiver operating characteristic curve analysis was used. Overall survival (OS) and disease-free survival (DFS) were analyzed by the Kaplan-Meier method. Results: The median follow-up period was 63.2 months (range, 2.7 to 206.8 months). Locoregional recurrence alone occurred in 6 patients, while distant metastasis was present in 16 patients, including 2 patients with simultaneous regional failure. The 5-year and 10-year OSs were 87.0% and 85.4%, respectively. The 5-year and 10-year DFSs were 83.8% and 82.5%, respectively. In multivariate analysis, pathologic type and tumor size were shown to be significant prognostic factors associated with both DFS and OS. In subset analysis of 40 patients who underwent preoperative PET/CT, total lesion glycolysis was shown to be the most significant prognostic factor among the clinicopathologic variables and metabolic parameters for DFS. Conclusion: Our results demonstrated that adjuvant RT following hysterectomy effectively improves local control. From the subset analysis of preoperative PET/CT, we can consider that metabolic parameters may hold prognostic significance in early uterine cervical cancer patients. More effective systemic treatments might be needed to reduce distant metastasis in these patients.

Burnt-out Metastatic Prostate Cancer

  • Shin, Dong Suk;Koo, Dong Hoe;Yoo, Suhyeon;Ju, Deok Yun;Jang, Cheol Min;Joo, Kwan Joong;Shin, Hyun Chul;Chae, Seoung Wan
    • Journal of Yeungnam Medical Science
    • /
    • v.30 no.2
    • /
    • pp.116-119
    • /
    • 2013
  • A burnt-out prostate cancer tumor is a very rare clinical entity. The term 'burnt-out' refers to a primary tumor that has spontaneously and nearly completely regressed without treatment. Since metastasis of prostate cancer is usually encountered in the presence of advanced disease, distant metastasis with an undetectable primary tumor is very rare. We report herein a case of a burnt-out prostate cancer tumor that metastasized to the thoracic (T) spine and caused cord compression. A 66-year-old man visited the Emergency Department due to weakness of both legs for the past two days. His blood and urine tests were normal at the time. His spine magnetic resonance imaging (MRI) scans looked like bone metastasis that involved the T-7 vertebral body and a posterior element, and caused spinal cord compression. Other images, including from the brain MRI, neck/chest/abdomino-pelvic computed tomography (CT) scan and 18F-fluorodeoxyglucose (FDG)-positron emission tomography (PET) and endoscopy, revealed no lesions that suggested malignancy. After total corpectomy T-7 and screw fixation/fusion at T5 to T10, the pathology report revealed a metastatic carcinoma that was strongly positive for prostate-specific antigen (PSA). The serum PSA value was 1.5 ng/mL. The transrectal 12-core prostate biopsy and ultrasonography showed no definitive hypoechoic lesion, but one specimen had slight (only 1%) adenocarcinoma with a Gleason score of 6 (3+3). The final diagnosis was burned-out prostate cancer with an initial normal PSA value. Although metastatic disease with an unknown primary origin was confirmed, a more aggressive approach in seeking the primary origin could provide a more specific treatment strategy and greater clinical benefit to patients.

Sarcoidosis Presenting with Massive Pleural Effusion and Elevated Serum and Pleural Fluid Carbohydrate Antigen-125 Levels

  • Lee, In Seon;Kim, Sae Byul;Moon, Chan Soo;Jung, Sung Mo;Kim, Song Yee;Kim, Eun Young;Jung, Ji Ye;Kang, Young Ae;Kim, Young Sam;Kim, Se Kyu;Chang, Joon;Park, Moo Suk
    • Tuberculosis and Respiratory Diseases
    • /
    • v.73 no.6
    • /
    • pp.320-324
    • /
    • 2012
  • A 55-year-old woman was admitted for an elevated serum carbohydrate antigen-125 (CA-125) level, and a left pleural effusion, which were detected at a routine health examination. Computed tomography of the chest was performed upon admission, revealing extensive bilateral paratracheal and mediastinal lymph node enlargement with a massive left-sided pleural effusion. Subsequent analysis of the pleural fluid demonstrated consistency with an exudate, no evidence of malignant cells, and a normal adenosine deaminase. However, the pleural fluid and serum CA-125 levels were 2,846.8 U/mL and 229.5 U/mL, respectively. A positron emission tomography did not reveal any primary focus of malignancy. Finally, a surgical mediastinoscopic biopsy of several mediastinal lymph nodes was performed, revealing non-necrotizing granulomas, consistent with sarcoidosis. After a month of treatment of prednisolone, the left pleural effusion had resolved, and after 2 months the serum CA-125 level was normalized.

Imaging Assessment of Primary Prostate Cancer, Focused on Advanced MR Imaging and PET/CT (자기공명영상과 PET/CT를 중심으로 한 전립선 암의 영상 진단)

  • Jang, Jin-Hee;Byun, Jae-Young;Kim, Min-Sung;Lee, Young-Joon;Oh, Sun-Nam;Rha, Sung-Eun;Yoo, Ie-Ryung
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.89-99
    • /
    • 2008
  • Imaging assessment of prostate cancer is one of the most difficult sections of oncology imaging. Detecting, localizing and staging of the primary prostate cancer by preoperative imaging are still challenging for the radiologist. Magnetic resonance (MR) imaging provides excellent soft tissue contrast and is widely used for solid organ imaging, but results of preoperative imaging of the prostate gland with conventional MR imaging is unsatisfactory. Positron emission tomography and computed tomography (PET/CT) is the cornerstone in oncology imaging, but some limitations prohibit the assessment of primary prostate cancer with PET or PET/CT. Recent studies to overcome these insufficient accuracies of imaging evaluation of primary prostate cancers with advanced MR techniques and PET and PET/CT are reported. In this article, we review the imaging findings of prostate cancer on variable modalities, focused on MR imaging and PET/CT.

  • PDF

Imaging Anatomy of Waldeyer's Ring and PET/CT and MRI Findings of Oropharyngeal Non-Hodgkin's Lymphoma

  • Zhang, Chun-Xing;Liang, Long;Zhang, Bin;Chen, Wen-Bo;Liu, Hong-Jun;Liu, Chun-Ling;Zhou, Zheng-Gen;Liang, Chang-Hong;Zhang, Shui-Xing
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.8
    • /
    • pp.3333-3338
    • /
    • 2015
  • Background: This study was conducted to analyze positron emission tomography (PET) / computed tomography (CT) and magnetic resonance imaging (MRI) performance with oropharyngeal non-Hodgkin's lymphoma (ONHL).Materials and Methods: The complete image data of 30 ONHL cases were analyzed, all patients were performed PET / CT and MRI examination before the treatment, with the time interval of these two inspections not exceeding 14 days. The distribution, morphology, MRI signal characteristics, enhancement feature, standardized uptake value (SUV) max value and lymph node metastasis way of the lesions were analyzed. Results: Among the 30 cases, 23 cases were derived from the B-cell (76.7%), 5 cases were derived from the peripheral T cells (16.7%) and 2 cases were derived from the NK/T cells (6.7%). 19 cases exhibited the palatine tonsil involvement (63.3%). As for the lesion appearance, 10 cases appeared as mass, 8 cases were the diffused type and 12 cases were the mixed type. 25 cases exhibited the SUVmax value of PET / CT primary lesions as 11 or more (83.3%). MRI showed that all patients exhibited various degrees of parapharyngeal side-compressed narrowing, but MRI still exhibited the high-signal fat, and the oropharyngeal mucosa was intact. 25 cases were associated with the neck lymph node metastasis, among who 22 cases had no necrosis in the metastatic lymph nodes, while the rest 3 cases exhibited the central necrosis in the metastatic lymph nodes. Conclusions: PET / CT and MRI have important value in diagnosing and determining the lesion extent of ONHL.