• 제목/요약/키워드: Positive Pressure Measurement

검색결과 86건 처리시간 0.032초

Relationship between 3D Ground Reaction Force and Leg Length Discrepancy during Gait among Standing Workers

  • Kim, Yong-Wook
    • PNF and Movement
    • /
    • 제20권1호
    • /
    • pp.59-66
    • /
    • 2022
  • Purpose: The aim of this research was to verify the relationship between three-dimensional (3D) ground reaction force (GRF) and severity of leg length discrepancy (LLD) while walking at a normal speed. It used a 3D motion analysis system with force platforms in standing workers with LLD. Methods: Subjects comprising 45 standing workers with LLD were selected. Two force platforms were used to acquire 3D GRF data based on a motion analysis system during gait. Vicon Nexus and Visual3D v6 Professional software were used to analyze kinetic GRF data. The subjects were asked to walk on a walkway with 40 infrared reflective markers attached to their lower extremities to collect 3D GRF data. Results: The results indicated the maximal force in the posterior and lateral direction of the long limb occurring in the early stance phase during gait had significant positive correlation with LLD severity (r = 0.664~0.738, p <0.01). In addition, the maximal force medial direction of the long limb occurring in the late stance phase showed a highly positive correlation with the LLD measurement (r = 0.527, p <0.01). Conclusion: Our results indicate that greater measured LLD severity results in more plantar pressure occurring in the foot area during heel contact to loading response of the stance phase and the stance push-off period during gait.

경동맥초음파 검사를 활용한 대사증후군 인자의 융합연구 (Study on Convergence Using Carotid Ultrasonography in Metabolic Syndrome risk factor)

  • 성현호;윤준
    • 한국융합학회논문지
    • /
    • 제6권6호
    • /
    • pp.195-200
    • /
    • 2015
  • 본 연구는 2014년 경기 남부의 종합건강검진센터에서 30-55세의 건강한 성인 47명을 대상으로 경동맥 초음파검사와 혈액검사 그리고 체격측정을 실시하여 성별과 연령 간에 동일한 집단으로 분석되었고, 대상자의 엉덩이둘레는 연령에 따라 40대가 50대보다 높은 결과로 나타났다(p<0.05). 경동맥 초음파 검사결과에서는 30대와 50대에서 차이를 보였다(p<0.05). CIMT와 BMI, CIMT와 엉덩이둘레에서 양의 상관관계를 보였다(p<0.05). 또한 혈압에서 CIMT와 수축기혈압은 양의 상관관계를 보였다(p<0.05). 결론적으로 이번 연구에서는 경동맥 내중막 두께로 대사증후군 인자와의 상관성을 입증하였으며, 향후 질병의 진단을 위해서는 초음파를 활용한 대사증후군 인자들의 융합적 연구가 보다 질적인 질병진단을 위해서는 지속적으로 연구되어야 할 것으로 사료된다.

요통으로 한방치료중인 폐경 후 여성의 대사증후군 요인이 골밀도에 미치는 영향에 관한 연구 (Study of Relationship between Metabolic Syndrome and Bone Mineral Density on Post Menopausal Chronic Low Back Pain Patients Under Oriental Medicine Treatment)

  • 이종덕;김동웅
    • 동의생리병리학회지
    • /
    • 제27권1호
    • /
    • pp.118-123
    • /
    • 2013
  • This study was performed from April, 2007 to August, 2012 with female patients who were being treated for and suffering from chronic lumbar pain for periods of 6 months and over. The 53 female patients were diagnosed with osteoporosis by having a T-Score of <-2.5 in a bone mineral density(BMD), as well as showing signs of metabolic syndrome. This was deduced by taking measurements of blood pressure, carrying out blood-chemical examinations and physical measurements such as weight, height, waist measurement and body mass index(BMI). After 5 minutes rest, the patient's blood pressure, height and weight were measured. BMI was calculated using the equation BMI = weight (Kg)/height ($m^2$). The patients had their blood taken in a fasted state(more than 12hours), the fasting blood sugar, total cholesterol, triglyceride, HDL-cholesterol were measured. The average BMD and T-score were calculated by measuring BMD(mg/cc) of L1-L3 using QCT. In a correlation analysis of the physical examinations, clinical character of metabolic syndrome and T-score, the result showed that age and T-score had a negative correlation(r=-0.699, p<0.01) as did triglyceride and T-score (r=-0.047, p<0.01), where as weight(r=0.239, p<0.05) and height(r-=0.329, p<0.01) and T-score had a positive correlation. There was no significant correlation with total cholesterol, HDL cholesterol, blood sugar, blood pressure and T-score. This study showed that there are significant correlations with age, weight, height and T-score. But there are no significant correlations with total cholesterol, HDL cholesterol, blood sugar, blood pressure and T-score and that these did not influence bone density. Further research with more subjects is required to determine whether there is a correlation of clinical character of metabolic syndrome and T-score.

Physiological and Psychological Effects of Vibroacoustic Stimulation to Scapular and Sacrum of Supine Position

  • Lim, Seung Yeop;Heo, Hyun;Kim, Sang Ho;Won, Byeong Hee
    • 대한인간공학회지
    • /
    • 제32권4호
    • /
    • pp.345-353
    • /
    • 2013
  • Objective: This research measured physiological and psychological effects of Vibroacoustic stimulation(VA) to scapular and sacrum of supine position on the mattress. Background: When vibroacoustic stimulation applies to human body, it has a positive influence on physiological and psychological effects by stimulating the organs, tissues and cells of whole body. Method: This experiment was conducted to 10 normal males in two conditions: no stimulation and vibroacoustic stimulation. No stimulation experiment was executed as a supine position for 30 minutes without any vibrational stimulus, while vibroacoustic stimulation was transmitted by the vibrational speaker, which uses 40Hz frequency. Subjects had a laser Doppler flowmeter probe in scapular, sacrum, and also had 8 channel electroencephalogram(EEG) measurement sensor in the scalp. Blood pressure and skin temperature were measured in two conditions with an underlying posture for 30 minutes. Additionally, blood flow rate and EEG were measured before and after for two minutes on two conditions. Results: According to the vibroacoustic stimulation, blood flow rate and skin temperature were increased, while blood pressure was decreased. When using vibroacoustic stimulation compared to no stimulation, blood flow rate went approximately two times higher, and skin temperature also higher 3~4 times. Furthermore, the relative alpha power of brain wave was significantly increased when we applied to vibroacoustic stimulation. Conclusion: This experiment tested the VAT embedded in mattress in two conditions. According to this experiment, VAT decreases blood pressure, improves not only a physiological effect on blood flow rate as well as skin temperature, but also psychological functions by increasing relative alpha power. Application: The results of the publishing trend analysis might help physiological and psychological effects of vibroacoustic stimulation.

Temperature Gradient for Tire Pavement Noise Measurement

  • Yeo, Woon-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • 제20권1E호
    • /
    • pp.3-6
    • /
    • 2001
  • Sound pressure level (SPL) measurements were performed on a controlled test track vehicle coast-by runs of a passenger vehicle with six different sets of tires across a range of temperatures. A small but significant reduction of noise level with positive temperature increases was observed for some tires. The temperature gradient of the different tires at 80㎞/h ranged from -0.07 to + 0.01 dB/℃. Frequency analysis of the tire noise identified that noise content in the range of 1,300 to 1,900Hz was particularly sensitive to temperature changes. Differences in SPL due to speed and tire type were much greater than that due to temperature.

  • PDF

공압 디스펜싱 시스템을 이용한 나노리터 액적에 포함된 미세 입자의 분주 및 측정 (Micro-particles in a Nanoliter Droplet Dispensed by a Pneumatic Dispensing System and Its Measurement)

  • 이상민;김준원
    • 한국정밀공학회지
    • /
    • 제29권8호
    • /
    • pp.913-919
    • /
    • 2012
  • This paper presents results for dispensing and measuring micro-particles using a pneumatic dispensing system. Particle-suspended liquid droplets were dispensed and analyzed quantitatively at various particle concentrations and applied pressures. By using a developed experimental setup, the number of particles and the particle volume ratio in sequentially dispensed droplets were measured. Hydrophilic and hydrophobic surfaces were tested to find a suitable surface for counting the number of particle. It was confirmed that the dispensed particles concentrated into the center of the droplet on the smooth CD surface after evaporation of liquid. As the applied positive pressure increased, the number of particles per droplet increased consistently and the volume fraction of particles remained constant.

$SF_6$ 기체중에서의 음이온 이동도 측정 (Measurement of the negative ion mobility of $SF_6$ gas)

  • 백용현;김정섭;배상돈;구본재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.249-251
    • /
    • 1988
  • In this paper, the negative ion mobility of $SF_6$ is determined using as a negative ion detector the burst pulse which is triggered in a positive point-plane gap by electrons detached from negative ions near the anode point. The result obtained for the negative ion mobility for zero field at atmospheric pressure is $0.57cm^2v^{-1}s^{-1}$.

  • PDF

The characteristics of MIS BST thin film capacitor

  • Park, Chi-Sun;Kim, In-Ki
    • 한국결정성장학회지
    • /
    • 제11권1호
    • /
    • pp.38-42
    • /
    • 2001
  • Electric and dielectric(Ba,Sr)$TiO_3$[BST] thin films for emtal-Insulator-Semiconductor(MIS) capacitors have been studied. BST thin films wre deposted on p-Si(100) substrates bythe RF magnetron sputtering with tempratue range of 500~$600^{\circ}C$. The dielectric properties of MIS capacitors consisting of Al/BST/$SiO_2$/Si sandwich structure were evaluated ot redcue the leakage current density. The charge state densities of the MIS capacitors were determined by high frequency (1 MHz) C-V measurement. In order to reduce the leakage current in MIS capacitor, high quality $SiO_2$ layer was deposited on bare p-Si substrate. Depending on the oxygen pressure and substrate temperature both positive and negative polarities of effective oxide charge in the MIS capacitors were evaluated. It is considered that the density of electronic states, generated at the BST/$SiO_2$/p-Si interface due to the asymmetric structure within BST/$SiO_2$/Si structure, and the oxygen vacancy content has influence on the behavior of oxide charge.

  • PDF

Anti-inflammatory and Anti-bacterial Effects of Aloe vera MAP against Multidrug-resistant Bacteria

  • Choi, Sang Hwa;Shin, Hea Soon
    • Natural Product Sciences
    • /
    • 제23권4호
    • /
    • pp.286-290
    • /
    • 2017
  • Multidrug-resistant Acinetobacter baumannii and Pseudomonas aeruginosa are highly dangerous nosocomial pathogens, cause the symptoms of skin infections, pressure sores, sepsis, blood stream and wound infections. Unfortunately, these pathogens are immune to the most common antibiotics, such as, carbapenem, aminoglycoside and fluoroquinolone. Therefore, it is imperative that new and effective antibiotics be developed. In the present study, the antimicrobial effects of Aloe vera MAP (modified Aloe polysaccharide) on Staphylococcus aureus and Bacillus subtilis, Escherichia coli and Enterobacter aerogenes, and clinical Pseudomonas aeruginosa and clinical Acinetobacter baumannii were comprehensibly investigated. Prior to the growth inhibition effect measurement and antibiotic disc diffusion assay on gram-positive and gram-negative bacteria and selected multidrug-resistant Pseudomonas aeruginosa and Acinetobacter baumannii, antimicrobial resistance screening was performed for the multidrug-resistant bacteria obtained from clinical isolates. The results for showed the Aloe vera MAP had a concentration-dependent effect on all of examined bacteria, particularly on Pseudomonas aeruginosa. Anti-inflammatory and anti-oxidant experiments were also performed dose dependently effects to confirm the beneficial physiological effects of Aloe vera MAP.

엔진 흡배기 소음원 특성의 특정법에 대한 수치적 연구 (Numerical Investigations of the Experimental Techniques for Measuring the Acoustical Source Parameters of a Simplified Exhaust System)

  • 이정권;장승호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.866-870
    • /
    • 2001
  • Measurement techniques for in-duct acoustic source parameters can be classified into the direct method and the load method, according to whether it utilizes an extra external source or not. It is reported that the load methods yield the negative source resistance and the purpose of this paper is to clarify that the time-varying nature of the source is the main cause of this physically implausible result. For this purpose, the direct and load methods for measuring the source characteristics of a simplified fluid machine are simulated using the time domain numerical analysis. In the numerical simulations, the method of characteristics is employed and the source characteristics are calculated from the resultant data. It is shown that the load method results in negative source resistance for some frequencies, whereas the direct method yields positive values for all frequencies considered. It is found that the result of load method is quite sensitive to the change of cylinder pressure or valve profile in contrast to the direct method.

  • PDF