• 제목/요약/키워드: Positive Position feedback Controller

검색결과 37건 처리시간 0.025초

전기유동유체와 압전세라믹을 이용한 복합지능구조물의 감쇠특성 연구 (A Study on the Damping Characteristics of a Hybrid Smart Structure Using Electrorheological Fluids and PZT)

  • 윤신일;박근효;한상보;최윤대
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2003년도 춘계학술대회 논문집
    • /
    • pp.382-387
    • /
    • 2003
  • Many type of smart materials and control laws are available to actively adjust the structure from various external disturbances. Usually, a certain type of control law to activate a specific smart material is tell established, but the effectiveness of the control scheme is limited by the choice of the smart materials and the responses of the structure. ER fluid is adequate to provide small but arbitrary control forces at any point along the structure. It was found that active vibration control of the structure embedded with ER fluids fluidly to suppress the vibration excited with broad band frequency due to the limited change of the structure characteristics. To compensate this limited effect of the control scheme with ER fluid alone, PPF control using PZT as an actuator is added to construct a hybrid controller.

  • PDF

압전세라믹을 이용한 능동진동제어장치의 개발 (Development of the Active Vibration Absorber Using Piezoelectric Actuators)

  • 곽명훈;허석;곽문규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 I
    • /
    • pp.476-481
    • /
    • 2001
  • This research is concerned with development of the active vibration absorber using piezoelectric actuators. This active isolation system consists of a-pairs of PZT actuators bonded on a S-shaped aluminum plate and the passive damping material. The active system is connected to the passive system in series. In this paper, one of the popular control techniques which have been successfully applied to the smart structure is the Positive Position Feedback(PPF) control. The digital PPF control lows downloaded to the DSP chip and a main program, which runs SISO PPF algorithm. The structure and dynamic characteristics of the proposed active vibration isolation system and described in detail. To demonstate the effectiveness of the active vibration control, the PPF controller is first employed. Experimental results show that the active vibration isolation is possible by means of the proposed system.

  • PDF

MFC 액츄에이터가 부착된 외팔 평판의 능동 진동 제어 (Active Vibration Control of Cantilever Plate Equipped with MFC Actuators)

  • 곽문규;양동호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.533-534
    • /
    • 2013
  • This paper is concerned with the active vibration control of rectangular plate equipped with MFC actuators. To this end, the dynamic model of the rectangular plate bonded with MFC sensors and actuators was derived by means of the Rayleigh-Ritz method. The MFC actuator and sensor were modeled based on the pin-force assumption. The theoretical model was then validated experimentally. The multiinput and multi-output (MIMO) Positive Position Feedback (PPF) controller was designed based on the natural mode shapes and implemented using dSpace system and Simulink. The proposed control algorithm was applied to the cantilever plate having two MFC wafers having both sensor and actuator. Numerical and experimental investigations were carried out. Both theoretical and experimental result shows that the proposed control algorithm can effectively suppress vibrations of cantilever plate.

  • PDF

펄스폭변조를 이용한 지능구조물의 능동진동제어 (Active Vibration Control of Smart Structure Using Pulse Width Modulation)

  • 곽문규;김기영;방세윤
    • 한국소음진동공학회논문집
    • /
    • 제15권1호
    • /
    • pp.105-111
    • /
    • 2005
  • This paper is concerned with the active vibration control of smart structure using actuator signal made of pulse width modulation. The pulse width modulation has been used in motor control, where the amount of energy fed into the motor is controlled by the pulse width instead of applied voltage. The advantage of using the pulse width modulation is that analog signal can be replaced by the digital signal so that we can reduce system costs and power consumption. The effect of pulse width modulation on the vibration response was investigated in this study and the valid transformation rule was found. Then, the pulse width modulation was realized using a microprocessor and electronic circuit. The active vibration suppression was carried out by combining the positive position feedback controller and the pulse width modulation. The experimental result shows that we can replace an expensive amplifier with a pulse width modulation system thus reducing the system cost. The result also shows that the active vibration control can be achieved by the pulse width modulation technique.

PZT와 ER유체를 적용한 복합지능구조물의 진동제어 (Vibration Control of Hvbrid Smart Structure Using PZT Patches and ER Fluids)

  • 윤신일;박근효;한상보
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.734-739
    • /
    • 2003
  • Many types of smart materials and control laws are available to actively adjust the structure from various external disturbances. Usually, a certain type of control laws to activate a specific smart material is well established, but the effectiveness of the control scheme is limited by the choice of the smart materials and the responses of the structure. ER fluid is adequate to provide relatively large control force, on the other hand, the PZT patches are suitable to provide small but arbitrary control forces at any point along the structure. It was found that active vibration control mechanism using ER fluid failed to suppress the excitation off the resonant frequency with changed structural characteristics along the frequency response function of the closed loop of the control system. To compensate this additional peak of the closed loop system, PPF control using PZT as an actuator is added to construct a hybrid controller.

  • PDF

압전 작동기를 이용한 유체 유기 진동의 능동 제어 (Active Control of Flow-Induced Vibration Using Piezoelectric Actuators)

  • 한재홍
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.446-451
    • /
    • 2003
  • This paper presents some examples of active control of flow-induced vibration using piezoelectric actuators. The flutter phenomenon, which is the dynamic instability of structure due to mutual interaction among inertia, stiffness, and aerodynamic forces, may cause catastrophic structural failure, and therefore the active flutter suppression is one of the main objectives of the aeroelastic control. Active flutter control has been numerically and experimentally studied for swept-back lifting surfaces using piezoelectric actuation. A finite element method, a panel aerodynamic method, and the minimum state space realization are involved in the development of the governing equation, which is efficiently used for the analysis of the system and design of control laws with modern control framework. The active control suppressed flow-induced vibrations and extended the flutter speed around by 10%. Another representative flow-induced vibration phenomenon is the oscillation of blunt bodies due to the vortex shedding. In general, it is quite difficult to set up the numerical model because of the strong non-linearity of the vortex shedding structure. Therefore, we applied adaptive positive position feedback controller, which requires no pre-determined model of the plant, and successfully suppressed the flow-induced vibration.

  • PDF

신경회로망과 능동대역필터를 이용한 시변 외팔보 능동 진동제어 (Active Vibration Control of A Time-Varying Cantilever Beam Using Band Pass Filters and Artificial Neural Network)

  • 함길;이희남;윤두병;한순우;박진호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.353-354
    • /
    • 2014
  • An active vibration control technique of a time-varying cantilever beam is proposed in this study. A simple in-house coil sensor instead of expensive commercial sensors was used to measure the vibrational displacement of the beam. Active band pass filters and artificial neutral net works detect the frequencies, amplitudes, and phases of the main vibration mode. The time constants of the low pass filter representing the positive position feedback controller are updated in real-time, which generates the control voltage input to actuate the piezoelectric actuator and suppress the vibration. An experiment was successfully performed to verify the algorithm for a cantilever beam, which fundamental natural frequency arbitrarily varies between 9 Hz ~ 18 Hz. The present active vibration suppression technique can be applied to variety of structures which undergoes large variation of dynamic characteristics while operating.

  • PDF