• Title/Summary/Keyword: Position Feedback

Search Result 708, Processing Time 0.029 seconds

Development of Control Algorithm for Ship Berthing and Unberthing Systems Using a Joystick (조이스틱을 이용한 선박의 입출항 및 접이안 시스템의 제어 알고리즘 개발)

  • Hong, Seong-Kuk;Jung, Yun-Ha;Kim, Sun-Young;Won, Moon-Cheol
    • Journal of Navigation and Port Research
    • /
    • v.31 no.5 s.121
    • /
    • pp.325-332
    • /
    • 2007
  • This study develops a control algorithm on berthing/unberthing system using a joystick for ships with thrusters and a rudder. A nonlinear mathematical model for low speed maneuvering of typical container ships is used to develop a MIMO(multi-input multi-output) nonlinear control algorithm for velocity feedback joystick control. Also a virtual HILS(hardware in the loop simulation) software program for berthing/unberthing is developed to test the performance of the nonlinear and a PID control algorithm. The program is developed using LabWindow/CVI, and a user can see current position and desired trajectory of ship in a monitor, then he can control forward and yaw velocities of a ship using a joystick. The simulation results show that the nonlinear mfd the PID controller have superior performance over a simple open loop joystick control algorithm.

The Effect of SNAGs and Biofeedback Training on the Integrative Propriocepcion and Function of the Patients with Cervical Disorder (목의 기능장애 환자들에게 SNAGs기법과 바이오피드백 훈련이 통합적 고유수용성 감각과 목의 기능에 미치는 효과)

  • Lee, Eun Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.284-290
    • /
    • 2020
  • This study was undertaken to determine the effects of SNAGs (sustained natural apophyseal glides) and visual convergence biofeedback on the proprioception and neck disability of patients with chronic neck dysfunction. A total of 31 patients with neck dysfunction were assigned to either SNAGs (n = 16) or biofeedback (n = 15). The groups were assessed for proprioception and neck disability, before and after the intervention. The SNAGs were performed using belt with flexion, extension and right-left rotation, whereas biofeedback training included visual feedback training with deep neck flexor. Intervention was implemented for 20 minutes, twice a week for 4 weeks. Biofeedback training a showed significant effect on the joint position sense (left and right rotation) as compared to the SNAGs group (p< 0.05), whereas neck disability index was significantly effective for SNAGs (p< 0.05). Ed. Notes: The previous statement lacked clarity. I have suggested the edit as per my understanding. Please review and revise appropriately, if required. Therefore, the SNAGs technique is effective for neck function, and biofeedback training is a positive intervention method for enhancing the proprioceptive sensation. In future studies on patients with neck pain, it may be possible to select an intervention method based on the characteristics of the disease.

Analysis Model for Design Based on Stiffness Requirement of Direct Drive Electromechanical Actuator (직구동 전기기계식 구동기의 강성요구규격에 기반한 설계용 해석모델)

  • Oh, Sang Gwan;Lee, Hee Joong;Park, Hyun Jong;Oh, Dongho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.47 no.10
    • /
    • pp.738-746
    • /
    • 2019
  • Instead of hydraulic actuation systems, an electromechanical actuation system is more efficient in terms of weight, cost, and test evaluation in the thrust vector control of the 7-ton gimbal engine used in the Korea Space Launch Vehicle-II(KSLV-II) $3^{rd}$ stage. The electromechanical actuator is a kind of servo actuator with position feedback and uses a BLDC motor that can operate at high vacuum. In the case of the gimballed rocket engine, a synthetic resonance phenomenon may occur due to a combination of a vibration mode of the actuator itself, a bending mode of the launcher structure, and an inertial load of the gimbals engine. When the synthetic resonance occurs, the control of the rocket attitude becomes unstable. Therefore, the requirements for the stiffness have been applied in consideration of the gimbal engine characteristics, the support structure, and the actuating system. For the 7-ton gimbal engine of the KSLV-II $3^{rd}$ stage, the stiffness requirement of the actuation system is $3.94{\times}10^7N/m$, and the direct drive type electromechanical actuator is designed to satisfy this requirement. In this paper, an equivalent stiffness analysis model of a direct drive electromechanical actuator designed based on the stiffness requirements is proposed and verified by experimental results.

Computer-Assisted Navigation in Total Knee Arthroplasty (내비게이션 장치를 이용한 슬관절 전치환술)

  • Jeong, Hwa-Jae;Park, Yong-Beom;Lee, Han-Jun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.53 no.6
    • /
    • pp.478-489
    • /
    • 2018
  • Total knee arthroplasty has become a standard procedure for advanced knee arthritis to relieve pain and improve function. Computer-assisted navigation systems have been used in total knee arthroplasty to improve the mechanical axis of the limb as well as the alignment and position of the components. A computer-assisted navigation system has the advantage of real-time feedback during surgery, such as mediolateral balance in extension and flexion gap, alignment of the lower limb, and components. On the other hand, the computer-assisted navigation system requires an additional stab wound for tracker fixation, which can increase the likelihood of superficial wound infection and stress fractures and increase the operation time and cost of surgery. The clinical efficacy of computer-assisted navigation in total knee arthroplasty is also controversial. Compared to the conventional technique, computer navigation improves the accuracy of the postoperative mechanical axis within outliers of $3^{\circ}$ varus or $3^{\circ}$ valgus. This paper reviews the surgical technique, pitfalls, clinical and radiological outcomes, useful clinical cases, and future perspectives in computer-assisted navigation total knee arthroplasty.

A Study of VR Interaction for Non-contact Hair Styling (비대면 헤어 스타일링 재현을 위한 VR 인터렉션 연구)

  • Park, Sungjun;Yoo, Sangwook;Chin, Seongah
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.2
    • /
    • pp.367-372
    • /
    • 2022
  • With the recent advent of the New Normal era, realistic technologies and non-contact technologies are receiving social attention. However, the hair styling field focuses on the direction of the hair itself, individual movements, and modeling, focusing on hair simulation. In order to create an improved practice environment and demand of the times, this study proposed a non-contact hair styling VR system. In the theoretical review, we studied the existing cases of hair cut research. Existing haircut-related research tend to be mainly focused on force-based feedback. Research on the interactive haircut work in the virtual environment as addressed in this paper has not been done yet. VR controllers capable of finger tracking the movements necessary for beauty enable selection, cutting, and rotation of beauty tools, and built a non-contact collaboration environment. As a result, we conducted two experiments for interactive hair cutting in VR. First, it is a haircut operation for synchronization using finger tracking and holding hook animation. We made position correction for accurate motion. Second, it is a real-time interactive cutting operation in a multi-user virtual collaboration environment. This made it possible for instructors and learners to communicate with each other through VR HMD built-in microphones and Photon Voice in non-contact situations.

Design of Low-cost Automated Ventilator Using AMBU-bag (암부백을 이용한 저가형 자동 인공호흡기 설계 및 제작)

  • Shin, Hee-Bin;Lee, Hyo-Kyeong;Oh, Ga-Young
    • Journal of Appropriate Technology
    • /
    • v.7 no.1
    • /
    • pp.51-58
    • /
    • 2021
  • This study proposes the design and implementation of a low-cost emergency ventilator which can be helpful during the COVID-19 pandemic where the supply of automatic ventilators is not smooth compared with the urgent demand worldwide. Easy implementation and lower price were made possible by using AMBU-bag and off-the-shelf embedded micro-controller board. Moreover, while 3D printing is used by companies and experts around the world to build prototype hardware, materials which are readily available from surrounding environments so that people in countries where it is difficult to access many advanced technologies could manufacture the system. The design features AMBU-bag automation, not use 3D printing, and it can contrl speed. By allowing speed control, ventilation can be performed according to the conditions of the patient being used. A complementary point in the study is that it is difficult to fix the start point of the wiper motor used first. A method for complementing this is a method for replacing the brush DC motor with a position feedback function. Secondly, the AMBU-bag may wear out in the long-term process of compressing the AMBU-bag because the arm and the fixing frame are made of wood. To complement this, the part of fixing frame and arm parts that the AMBU-bag touches need to be wrapped in a material such as silicon to minimize friction.

The Immunological Position of Fibroblastic Reticular Cells Derived From Lymph Node Stroma (림프절 스트로마 유래 Fibroblastic Reticular Cell의 면역학적 위치)

  • Jong-Hwan Lee
    • Journal of Life Science
    • /
    • v.34 no.5
    • /
    • pp.356-364
    • /
    • 2024
  • Lymph nodes (LNs) are crucial sites where immune responses are initiated to combat invading pathogens in the body. LNs are organized into distinctive compartments by stromal cells. Stromal cell subsets constitute special niches supporting the trafficking, activation, differentiation, and crosstalk of immune cells in LNs. Fibroblastic reticular cells (FRC) are a type of stromal cell that form the three-dimensional structure networks of the T cell-rich zones in LNs, providing guidance paths for immigrating T lymphocytes. FRCs imprint immune responses by supporting LN architecture, recruiting immune cells, coordinating immune cell crosstalk, and presenting antigens. During inflammation, FRCs exert both spatial and molecular regulation on immune cells through their topological and secretory responses, thereby steering immune responses. Here, we propose a model in which FRCs regulate immune responses through a three-part scheme: setting up, supporting, or suppressing immune responses. FRCs engage in bidirectional interactions that enhance T cell biological efficiency. In addition, FRCs have profound effects on the innate immune response through phagocytosis. Thus, FRCs in LNs act as gatekeepers of immune responses. Overall, this study aims to highlight the emerging roles of FRCs in controlling both innate and adaptive immunity. This collaborative feedback loop mediated by FRCs may help maintain tissue function during inflammatory responses.

Development of an Offline Based Internal Organ Motion Verification System during Treatment Using Sequential Cine EPID Images (연속촬영 전자조사 문 영상을 이용한 오프라인 기반 치료 중 내부 장기 움직임 확인 시스템의 개발)

  • Ju, Sang-Gyu;Hong, Chae-Seon;Huh, Woong;Kim, Min-Kyu;Han, Young-Yih;Shin, Eun-Hyuk;Shin, Jung-Suk;Kim, Jing-Sung;Park, Hee-Chul;Ahn, Sung-Hwan;Lim, Do-Hoon;Choi, Doo-Ho
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.91-98
    • /
    • 2012
  • Verification of internal organ motion during treatment and its feedback is essential to accurate dose delivery to the moving target. We developed an offline based internal organ motion verification system (IMVS) using cine EPID images and evaluated its accuracy and availability through phantom study. For verification of organ motion using live cine EPID images, a pattern matching algorithm using an internal surrogate, which is very distinguishable and represents organ motion in the treatment field, like diaphragm, was employed in the self-developed analysis software. For the system performance test, we developed a linear motion phantom, which consists of a human body shaped phantom with a fake tumor in the lung, linear motion cart, and control software. The phantom was operated with a motion of 2 cm at 4 sec per cycle and cine EPID images were obtained at a rate of 3.3 and 6.6 frames per sec (2 MU/frame) with $1,024{\times}768$ pixel counts in a linear accelerator (10 MVX). Organ motion of the target was tracked using self-developed analysis software. Results were compared with planned data of the motion phantom and data from the video image based tracking system (RPM, Varian, USA) using an external surrogate in order to evaluate its accuracy. For quantitative analysis, we analyzed correlation between two data sets in terms of average cycle (peak to peak), amplitude, and pattern (RMS, root mean square) of motion. Averages for the cycle of motion from IMVS and RPM system were $3.98{\pm}0.11$ (IMVS 3.3 fps), $4.005{\pm}0.001$ (IMVS 6.6 fps), and $3.95{\pm}0.02$ (RPM), respectively, and showed good agreement on real value (4 sec/cycle). Average of the amplitude of motion tracked by our system showed $1.85{\pm}0.02$ cm (3.3 fps) and $1.94{\pm}0.02$ cm (6.6 fps) as showed a slightly different value, 0.15 (7.5% error) and 0.06 (3% error) cm, respectively, compared with the actual value (2 cm), due to time resolution for image acquisition. In analysis of pattern of motion, the value of the RMS from the cine EPID image in 3.3 fps (0.1044) grew slightly compared with data from 6.6 fps (0.0480). The organ motion verification system using sequential cine EPID images with an internal surrogate showed good representation of its motion within 3% error in a preliminary phantom study. The system can be implemented for clinical purposes, which include organ motion verification during treatment, compared with 4D treatment planning data, and its feedback for accurate dose delivery to the moving target.