• 제목/요약/키워드: Portable sensor

검색결과 299건 처리시간 0.025초

통계적 분석법을 활용한 도로용 원더링 장비개발 (Development of Portable Wandering Device using Statistical Analysis)

  • 김낙석;박창우;박현식;김주열
    • 한국재난정보학회 논문집
    • /
    • 제3권1호
    • /
    • pp.5-20
    • /
    • 2007
  • The role of a pavement means a social axis for the future as well as a function of road itself. To achieve its intended purposes, the maintenance technique of the pavement performance should be improved. For this, pavement investigators have dealt with the simulated pavement sites under actual environmental conditions. One of them is wandering device to improve the maintenance system of a pavement. The primary purpose of this research is to develop a portable wandering device using statistical analysis technique. It is noted that the new device using laser sensor demonstrates better field applications and reliability compare to the conventional one.

  • PDF

LED 조명 제어를 위한 컬러센서 기반 포터블 스캐너 개발 (A Development of a Portable Color Scanner Using Photo Sensors for Full-Color LED Illumination Control)

  • 천성용;이찬수
    • 조명전기설비학회논문지
    • /
    • 제25권11호
    • /
    • pp.14-25
    • /
    • 2011
  • Full-Color LED lighting system requires efficient control of the lighting color in order to easily achieve various color effects. In this paper, we present not only a portable color scanner using color sensors which can control lighting color directly from detected color but also methods to convert detected color to a complementary color, similar colors and so on. In addition, we propose a compensation method for measured sensor color to reduce measurement errors more than 50[%] in detected color. The developed color scanner is applied to control full-color LED ceiling light for emotional lighting.

휴대용 혈중pH 측정시스템의 구현 (Development of Portable System for Measuring pH in Blood)

  • 정도운;김우열;배진우;강성철;심윤보;전계록
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(5)
    • /
    • pp.195-198
    • /
    • 2001
  • We developed the portable blood analysis system, which can be measured pH of the blood. This system is composed to electronic circuit, mechanism, and system software. Electronic circuit is composed to the sensor, pre-amp part, temperature regulation part, fluid sensing part, A/D(analog to digital) conversion part, main and peripheral device processing part. And the mechanism is composed to the flow cell and the liquid flow part. The liquid flow part is consisted of blood and washing control system under the control of the 6-channel solenoid valve and syringe rump. The system software is composed to measurement program, calibration program, washing and diagnostic program. The program of each routine is designed as sequential process for an efficiency. And the portable pH analysis system used two-point calibration method using the two types of corrective liquid. As a result, we obtained the calibration curve and calculated the value of pH. For verifying the system, we confirmed the output voltage of the sensor, and estimated reappearance of system using the standard liquid.

  • PDF

Geo-referenced 영상 획득을 위한 휴대용 멀티센서 시스템 구축 및 정확도 평가 (Development of a Portable Multi-sensor System for Geo-referenced Images and its Accuracy Evaluation)

  • 이지훈;최경아;이임평
    • 한국측량학회지
    • /
    • 제28권6호
    • /
    • pp.637-643
    • /
    • 2010
  • 본 연구에서는 비디오카메라와 GPS/MEMS IMU, UMPC를 결합하여 영상과 위치/자세 데이터를 획득하는 휴대용 멀티센서 시스템을 구축하였다. 구축된 시스템을 통해 획득된 데이터를 이용하여 지상기준점을 이용하지 않고 광속조정법 기반의 영상 geo-referencing을 수행하고 정확도 검증을 통해 시스템의 효용성을 평가하였다. 정확도 검증 결과, 지상점의 상대좌표 정확도는 RMSE가수 cm내외로 상당히 정확함을 확인할 수 있었다. 구축된 시스템은 대상 객체의 3차원 모델과 상대좌표를 획득하는데 있어서 충분히 활용 가능하다고 판단된다. 향후에는 시스템 및 카메라의 엄밀한 보정을 통해 절대좌표의 정확도를 개선할 예정이다.

압전효과를 이용한 압인방식의 휴대용 피부탄력 측정장치 (A Portable Skin Elasticity Measuring Device Based on Indentation Method Using Piezoelectric Effect)

  • 박준영;김명남
    • 한국멀티미디어학회논문지
    • /
    • 제25권9호
    • /
    • pp.1307-1315
    • /
    • 2022
  • In this paper, we proposed and developed a new portable skin elasticity measuring device based on the indentation method using piezoelectric effect. The proposed device is designed to minimize the uncertainty caused by the layer structure of the skin when measuring the elasticity of the skin. And, we developed a piezoelectric-based thin-film pressure sensor that can measure quantitatively and quickly during repeated measurement as a device sensor. To confirm the effectiveness of the proposed measuring device, it was compared with the experimental results of the conventional measuring devices under the same experimental conditions, and statistical correlation analysis was performed between the experimental data of the proposed measuring device and the experimental data of the conventional measuring devices. As a result of the correlation analysis, it was confirmed that the proposed measuring device had a high correlation with the conventional measuring devices. Therefore, it was confirmed that the proposed skin elasticity measuring device was effective.

Portable Amperometric Perchlorate Selective Sensors with Microhole Array-water/organic Gel Interfaces

  • Lee, Sang Hyuk;Kim, Hyungi;Girault, Hubert H.;Lee, Hye Jin
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권9호
    • /
    • pp.2577-2582
    • /
    • 2013
  • A novel stick-shaped portable sensing device featuring a microhole array interface between the polyvinylchloride-2-nitrophenyloctylether (PVC-NPOE) gel and water phase was developed for in-situ sensing of perchlorate ions in real water samples. Perchlorate sensitive sensing responses were obtained based on measuring the current changes with respect to the assisted transfer reaction of perchlorate ions by a perchlorate selective ligand namely, bis(dibenzoylmethanato)Ni(II) (Ni(DBM)2) across the polarized microhole array interface. Cyclic voltammetry was used to characterize the assisted transfer reaction of perchlorate ions by the $Ni(DBM)_2$ ligand when using the portable sensing device. The current response for the transfer of perchlorate anions by $Ni(DBM)_2$ across the micro-water/gel interface linearly increased as a function of the perchlorate ion concentration. The technique of differential pulse stripping voltammetry was also utilized to improve the sensitivity of the perchlorate anion detection down to 10 ppb. This was acquired by preconcentrating perchlorate anions in the gel layer by means of holding the ion transfer potential at 0 mV (vs. Ag/AgCl) for 30 s followed by stripping the complexed perchlorate ion with the ligand. The effect of various potential interfering anions on the perchlorate sensor was also investigated and showed an excellent selectivity over $Br^-$, $NO_2{^-}$, $NO_3{^-}$, $CO{_3}^{2^-}$, $CH_3COO^-$ and $SO{_4}^{2^-}$ ions. As a final demonstration, some regional water samples from the Sincheon river in Daegu city were analyzed and the data was verified with that of ion chromatography (IC) analysis from one of the Korean-certified water quality evaluation centers.

NDIR 방법을 이용한 복합 가스 측정 시스템 (Composite Gas Measurement System using NDIR Method)

  • 어익수
    • 한국산학기술학회논문지
    • /
    • 제19권3호
    • /
    • pp.624-629
    • /
    • 2018
  • 본 논문은 NDIR(Non Dispersive Infra Red) 방식을 적용하여 $CO_2$$CH_4$의 두 가지 가스를 하나의 휴대용 장치에서 측정이 가능하도록 제작된 복합 가스 측정 장치에 대한 연구이다. 측정 장치의 구성은 적외선램프에서 적외선이 방출되면 방출된 파장이 광학창을 거치면서 흡수로 인하여 빛이 줄어들게 되고 이 감소량(흡수도)을 검출기에서 검출하고 이를 전기적 신호로 변환 증폭하여(3.5V~6V) 정확한 측정이 가능함을 보여준다. 기존의 Single Sensor 방식은 적외선에서 특수파장을 흡수하여 상대 측정량을 검출하는 방식으로 가스의 경우 $4.26{\mu}m$파장의 빛만을 검출하여 측정하는 방식으로 센서의 값을 보정할 수 있는 기준센서가 없어 오차가 발생하는 문제가 발생하였다. 본 연구에 적용된 Dual Sensor 방식은 다른 가스의 영향을 받지 않는 $3.91{\mu}m$의 기준치와 가스의 $4.26{\mu}m$의 두 파장을 검출하여 비교측정 함으로써 오차가 적어 신뢰도가 높은 방식으로, 휴대형으로 소형화하여 저 전력화가 가능하며, $CO_2$$CH_4$의 2가지 가스농도를 복합적으로 측정 할 수 있다는 특징이 있다. 측정 범위는 $CO_2$의 경우 0ppm~5,000ppm이고 $CH_4$의 경우는 0~5%의 부피 농도로 실내 공기량 1,000ppm을 측정 할 수 있도록 제작되어 휴대용이나 주택의 Home automation과 연동하여 소화연동이 가능함으로 화재예방에 매우 효과적일 것으로 확인하였다.

휴대용 전자코에 의한 된장의 숙성정도 예측 (Prediction of Fermentation Time of Korean Style Soybean Paste by using The Portable Electronic Nose)

  • 노봉수;양영민;이택수;홍형기;권철한;성영권
    • 한국식품과학회지
    • /
    • 제30권2호
    • /
    • pp.356-362
    • /
    • 1998
  • 된장의 숙성기간을 예측하기 위하여 6개의 metal oxide sensor로 구성된 휴대용 전자코를 이용하였다. Aspergillus oryzae를 사용하여 담금한 된장은 각각 $15,\;20\;25^{\circ}C$에서 숙성시켰다. 전자코에 의한 감응도 변화량은 숙성기간에 따라 온도가 높아짐에 따라 크게 감소되었으며 센서 #3과 #4는 된장의 숙성정도와 기간간에 높은 상관관계를 보여주었다$(r^2=0.71{\sim}0.95)$. 그리고 숙성기간중 생성되는 아미노태질소와 전자코의 감응도 변화간에도 상관관계를 나타내어 휴대용 전자코로 된장의 숙성기간을 예측할 수 있었다.

  • PDF

가스센서 어레이와 인공 신경망을 이용한 소형 전자코 시스템의 제작 및 특성 (Fabrication and Characterization of Portable Electronic Nose System using Gas Sensor Array and Artificial Neural Network)

  • 홍형기;권철한;윤동현;김승렬;이규정
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 춘계학술대회 논문집
    • /
    • pp.99-102
    • /
    • 1997
  • An electronic nose system is an instrument designed far mimicking human olfactory system. It consists generally of gas (odor) sensor array corresponding to olfactory receptors of human nose and artificial neural network pattern recognition technique based on human biological odor sensing mechanism. Considerable attempts to develop the electronic nose system have been made far applications in the fields of floods, drinks, cosmetics, environment monitoring, etc. A portable electronic nose system has been fabricated by using oxide semiconductor gas sensor array and pattern recognition technique such as principal component analysis (PCA) and back propagation artificial neural network The sensor array consists of six thick film gas sensors whose sensing layers are Pd-doped WO$_3$ Pt-doped SnO$_2$ TiO$_2$-Sb$_2$O$_3$-Pd-doped SnO$_2$ TiO$_2$-Sb$_2$O$_{5}$-Pd-doped SnO$_2$+Pd filter layer, A1$_2$O$_3$-doped ZnO and PdCl$_2$-doped SnO$_2$. As an application the system has been used to identify CO/HC car exhausting gases and the identification has been successfully demonstrated.d.

  • PDF

Thiolated protein G로 개질된 SPR 센서 칩을 이용한 IgG 검출 (Detection of IgG Using Thiolated Protein G Modified SPR Sensor Chip)

  • 신은정;이연경;손영수
    • 센서학회지
    • /
    • 제20권6호
    • /
    • pp.434-438
    • /
    • 2011
  • A portable surface plasmon resonance(SPR) based immunosensor using thiolated protein G and protein G was developed for the detection of immunoglobulin G(IgG). The protein G has specific affinity with Fc fragment of IgG and was thiolated by 2-Iminothiolane for introduction of thiol groups. Anti-IgG, bovine serum albumin(BSA), and IgG have been sequently injected after surface modification of gold sensor chip with protein G and thiolated protein G. The output signal was increased with the injection of each protein and the actual signal was measured by subtracting signal of reference channel from signal of sample injected channel. The experimental results showed the higher detection capability of IgG using thiolated protein G compared with protein G. From these results, we can conclude that the current surface modification technique and the portable SPR sensor system can be applied to various immunosensors for diagnosis.