• Title/Summary/Keyword: Porous pavement

Search Result 84, Processing Time 0.025 seconds

Development of Drainage Asphalt Mixture Using Large Size Aggregate and Its Performance on Test Pavement

  • Ogino Shoji;Ohmae Tatsuhiko;Matsumoto Yuki;Yamada Masaru
    • International Journal of Highway Engineering
    • /
    • v.8 no.1 s.27
    • /
    • pp.107-117
    • /
    • 2006
  • Recently, there has been a remarkable trend of using aggregates at sizes smaller than 13 mm for drainage asphalt pavement (DAP) in order to reduce the noise generated between vehicle tires and road surface. These DAPs have their performance and durability seriously worsen after several years in-service due to the clogging of void space and the abrasion. This paper proposes the use of large size aggregates in porous asphalt mixtures to overcome these defects. Results of laboratory and field experiments on asphalt mixtures with several aggregate gradations are investigated and compared. The study focuses on advantages of DAP using large size aggregate and on particle size combinations containing no fine aggregates of size 2.36 mm or less, which have not been considered in current engineering practice.

  • PDF

Volume of Water Storage and Evapotranspiration by Inserted Materials at a Reservoir of Porous Grass Block (저수형 잔디블록 저수조 내 충진재료에 따른 저수량 및 초종별 증발산량)

  • Han, Seung-Ho;Choi, Joon-Soo;Yang, Geun-Mo;Yang, Byoung-E;Kang, Jin-Hyoung;Kim, Won-Tae
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.34 no.5 s.118
    • /
    • pp.76-83
    • /
    • 2006
  • The purpose of this study was to investigate the performance of porous grass block. For the investigation, Festuca arundinacea and Zoysia japonica 'Zenith' were planted, and the volume of evapotranspiration and remains were examined based on different materials in the water tank in the experiment of Festuca arundinacea, the volume of water storage of treatment with perlite ($10.84{\iota}/m^2$) was higher than that with drainage ($7l/m^2$). The difference between the two was $3.84/m^2$. The drainage treatment without water storage capacity showed the higher degree of dryness in turf grass. The volume of evapo-transpiration of treatment with perlite was the highest (21.57mm/week). The volume of evapotranspiration of treatment with sand was 19.57mm/week, and with treatment with drainage was 18.24mm/week. Based on the measured volume of daily evapotranspiration of $2.60{\sim}3.08mm\;d^{-1}$, it was determined that the unit with water storage capacity would store water of one to two days usage compared to unite without such storage capacity. In the experiment of Zoysia japonica 'Zenith', the volume of water storage of treatment with perlite was $10.77l/m^2$ which was similar to the former experiment. The volume of evapotranspiration of treatment with perlite and sand were 21.64mm/week and 20.64mm/week, respectively. In case of airtight water tank, the volume was measured as 22.06mm/week. Each treatment has no notable difference in the volume of evapotranspiration. In conclusion, from the investigation in this study, porous grass block with water tank was found to be effective in plant growth under low irrigation. As the ecological area ratio and vegetated porous pavement have became more emphasized, additional study of rain infiltration and reservoir effect are needed in the future.

Noise reduction of Asphalt Concrete Pavement : Techniques and their performance evaluation (아스팔트 저소음 포장의 개발 및 공용성 평가)

  • Ock, Chang-Kwon;Kim, Jin-Hwan;Lee, Jong-Sup
    • International Journal of Highway Engineering
    • /
    • v.12 no.1
    • /
    • pp.29-37
    • /
    • 2010
  • Porous pavements can provide road users with beneficial characteristics such as skid resistance and surface water drainage under rainy condition, and they cause less tire-road noise than conventional hot mix asphalt(HMA) pavements. However, voids of porous pavements are easily clogged by road debris at early stages, which leads to frequent maintenance works. Therefore, this study focused on the way of minimizing void clogging in porous pavements. During mixture design, the quantity of coarse aggregate has been increased to form many straight void conduits (SVCs) in porous HMAs. These SVCs were found to be effective resisting the void clogging problems. Four different porous HMAs(19mm, 13mm, 10mm, and 8mm) were developed and placed on highway roads. Their performances were validated with field tests during the past four years.

Heat Transfer Characteristics of the Asphalt pavement by Solar Energy accumulation (열에너지 누적에 따른 아스팔트 포장의 열전달 특성 변화)

  • Lee, Kwan-Ho;Kim, Seong-Kyum;Oh, Seung-Sig
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.490-497
    • /
    • 2020
  • Asphalt pavement accounts for more than 90% of the total pavement in Korea. Pavement is most widely constructed among construction structures. The heat transfer characteristics (Thermophysical Properties) of the asphalt pavement cause the heat island effect in downtown areas. An increasing asphalt surface temperature is one of the major causes of damage to asphalt pavement. This study examined the heat transfer characteristic factors according to solar energy accumulation in an asphalt mixture. The specimens (WC-2 & PA-13, Recycled aggregate used WC-2) used in the experiment were compacted with a Gyratory Compactor. The thermo-physical properties (thermal conductivity, specific heat capacity, thermal diffusivity, and thermal emissivity) and solar energy accumulation were evaluated. The thermal accumulation and HFM tests revealed a 1.2- to 2.0-fold difference. This indicates that the thermal conductivity of the asphalt mixture pavement changes with the accumulation of solar energy. An analysis of the correlation of thermal conductivity according to the surface temperature of the asphalt mixture showed that WC-2 was logarithmic, and PA-13 was linear. Experiments on the heat transfer characteristics of asphalt pavement that can be used for thermal failure modeling of asphalt were conducted.

An Experimental Study on the Mechanical Properties of Porous Concrete Using Coal Ash and Polymer (석회석 골재를 사용한 강섬유보강 포러스콘크리트의 강도특성에 관한 실험적 연구)

  • Lee, Byung-Jae;Park, Seong-Bum;Jang, Young-Il;Jeon, Heum-Jin;Lee, Taek-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.685-688
    • /
    • 2008
  • Concrete is strong on the compressive property, but weak on the tensile and flexural properties. To improve these problems, the reinforcing bar is used in concrete. But porous concrete with steel fiber has a weak point when exposed to air, because porous concrete has the vast continuous void on its inside and steel fiber is easily rusted by air. For these reasons, this study investigated the void ratio, compressive strength, bending strength and bending toughness as steel fiber mixing ratio and target void ratio. From test results, actual void ratio and strength properties increased as the mixing ratio of steel fiber increase. In case the mixing ratio of steel fiber over the fixed ratio, strength is decreased. And from the toughness evaluation, compared to the porous concrete which isn't mixed with steel fiber, the deflection variation efficiency is remarkably improved. Consequently we can confirm the possibility of porous concrete with steel fiber for the secondary product and pavement material to improve strength and bending resistance efficiency.

  • PDF

Experimental Study of the Changing Characteristics of Geocell with Load Carrying capacity (지오셀 특성 변화에 따른 하중지지력 연구)

  • Hong, Seungrok;Choi, Jinwook;Yoo, Chungsik;Lee, Daeyoung;Lee, Suhyung;Yoo, Inkyoon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.12 no.3
    • /
    • pp.1-13
    • /
    • 2013
  • This paper presents the results of a laboratory investigation of the porous pavement substructure effect when reinforced with geocell. In order to analyze load carrying capacity of Geocell, a series of 9 reduced-scale laboratory tests was performed, changing the type, thickness, diameter of Geocell. The results of the analyses indicated that the bearing capacity of the reinforced Geocell increases much more than the non-reinforced Geocell and load carrying capacity was considered to be insignificant according to the type of Geocell. It was also found that the most supportive effects appeared as 30 cm in diameter and 1.8mm in thickness.

An Application of Infiltration Facilities for Reducing the Runoff in the Basin (유출저감을 위한 유역내 침투시설의 적용)

  • Lee, Jae-Joon;Seol, Ji-Su
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.3
    • /
    • pp.133-141
    • /
    • 2011
  • Urban development of basin causes increasing runoff volume and peak flowrate and shortening in time of concentration, which may cause frequent flooding downstream. An infiltration facilities are operated as a method of reducing flood discharge of urban rivers and peak flowrate. There are various types of infiltration facilities like infiltration trench and porous pavement. In this study, runoff reduction effect due to installation of infiltration facilities are performed and focused on $0.18km^2$ residential area of Ok-kye dong and $0.67km^2$ industrial area of Gong-dan dong in Gumi City. The analysis is fulfilled with comparison of total runoff volume and runoff reduction volume by using the WinSLAMM and the relation equation between area ratio of infiltration facilities and ratio of runoff reduction are derived and peak flow reduction effect for installation of infiltration facilities is analyzed.

Experimental Study on the Pore Clogging Phenomenon of Porous Concrete (투수콘크리트의 공극막힘현상에 대한 실험적 연구)

  • Nam, Jung-Man;Yun, Jung-Mann;Kim, Seung-Hyun;Song, Young-Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.4D
    • /
    • pp.577-584
    • /
    • 2011
  • A series of field and laboratory permeability tests were performed to investigate the pore-clogging phenomenon of porous concrete used for pavement materials of a road. The field permeability tests were conducted for 37 study points in Jeju city, using the porous concretes with 13mm of maximum coarse aggregate ($G_{max}$). The results show that the service life of porous concrete is about 22 months when the permeability of the porous concrete is designed for 0.01 cm/sec. Some specimens were made with the purpose of recreating pore-clogging phenomenon. Tests were done for injected concentration of pore-clogging materials or size of maximum coarse aggregates ($G_{max}$). The test results demonstrated that relatively long in service life experienced with small amount of injected concentration of pore-clogging materials, whereas relatively short in service life experienced with a reduction in size of maximum coarse aggregates ($G_{max}$). In conclusion, the service life of porous concrete is in proportion to the concentration of pore-clogging material but it is in inverse proportion to the size of maximum coarse aggregate ($G_{max}$). Thus, the persisting period of porous concrete can be determined with respect to concentration of pore-clogging materials or size of maximum coarse aggregates ($G_{max}$).

Effect of Iron Ore Tailings Replacing Porous Basalt on Properties of Cement Stabilized Macadam

  • Qifang Ren;Fan Bu;Qinglin Huang;Haijun Yin;Yuelei Zhu;Rui Ma;Yi Ding;Libing Zhang;Jingchun Li;Lin Ju;Yanyan Wang;Wei Xu;Haixia Ji;Won-Chun Oh
    • Korean Journal of Materials Research
    • /
    • v.34 no.6
    • /
    • pp.291-302
    • /
    • 2024
  • In this paper, iron ore tailings (IOT) were separated from the tailings field and used to prepare cement stabilized macadam (CSM) with porous basalt aggregate. First, the basic properties of the raw materials were studied. Porous basalt was replaced by IOT at ratios of 0, 20 %, 40 %, 60 %, 80 %, and 100 % as fine aggregate to prepare CSM, and the effects of different cement dosage (4 %, 5 %, 6 %) on CSM performance were also investigated. CSM's durability and mechanical performance with ages of 7 d, 28 d, and 90 d were studied with the unconfined compression strength test, splitting tensile strength test, compressive modulus test and freeze-thaw test, respectively. The changes in Ca2+ content in CSM of different ages and different IOT ratios were analyzed by the ethylene diamine tetraacetic acid (EDTA) titration method, and the micro-morphology of CSM with different ages and different IOT replaced ratio were observed by scanning electron microscopy (SEM). It was found that with the same cement dosage, the strengths of the IOT-replaced CSM were weaker than that of the porous basalt aggregate at early stage, and the strength was highest at the replaced ratio of 60 %. With a cement dosage of 4 %, the unconfined compressive strength of CSM without IOT was increased by 6.78 % at ages from 28 d to 90 d, while the splitting tensile strength increased by 7.89 %. However, once the IOT replaced ratio reached 100 %, the values increased by about 76.24 % and 17.78 %, which was better than 0 % IOT. The CSM-IOT performed better than the porous basalt CSM at 90 d age. This means IOT can replace porous basalt fine aggregate as a pavement base.

A Feasibility Study of Wood-plastic Composite Paver Block for Basic Rest Areas

  • Yang, Sungchul
    • Journal of the Korean Wood Science and Technology
    • /
    • v.47 no.1
    • /
    • pp.51-65
    • /
    • 2019
  • A wood-plastic composite (WPC) paver block was manufactured using wood chips waste through an extrusion process, and it was intended to be used for paving in basic rest areas. The first stage in this study covered preliminary tests in terms of flexural strength and dimensional swelling to determine the optimal WPC compounding mix condition, by variation of the WPC ingredients. Next, three different paver blocks including the WPC block, a non-porous cement block, and a porous cement block were tested in terms of various material properties in the laboratory. Finally, two outdoor test sections of the proposed paver blocks were prepared to simulate a basic rest area. Test results indicated that the flexural strength of the WPC paver blocks was about 1.6 times greater than that of the tested cement paver blocks. The WPC block pavement was unaffected by water buoyance as well as volume expansion due to swelling. Results from the impact absorbance test and light falling weight deflectometer (LFWD) test clearly showed that the WPC block paving system marginally satisfied the comfortable and safe hardness range from the pedestrians' perspective, while the results demonstrated that it is structurally sound for application as a road paving block.