• Title/Summary/Keyword: Porous Substrate

Search Result 300, Processing Time 0.026 seconds

Recent applications of lubricant-impregnated nanoporous surface : A Review (윤활액이 담지된 나노다공성 표면의 최신 응용분야)

  • Kyeongwan Han;Kichang Bae;Junghoon Lee
    • Journal of the Korean institute of surface engineering
    • /
    • v.56 no.1
    • /
    • pp.1-11
    • /
    • 2023
  • Lubricant-impregnated nanoporous surfaces (LIS), which is created by impregnating water-immiscible oil into nanoporous surface structure, have been explored considering wide range of application fields. Due to the lubricant impregnated in nanoporous structure, the surface shows extreme de-wetting with a high mobility of water droplets, so that various functionalities can be realized. The lubricant layer inhibits the contact of corrosive media to porous structure as well as metal substrate, thus the surface improves the corrosion resistance. The water on the surface freeze without any contact to solid porous structure, showing a low ice adhesion for de-icing an anti-icing. The extremely high mobility of water droplets on lubricant-impregnated porous surfaces also contributes the enhancement of condensation heat transfer as well as water harvesting from fog and moisture. Moreover, the bacteria adhesion on metal surface forming biofilms causing serious hygiene issues can be inhibited on the lubricantimpregnated surfaces. Despite of such superior functionalities, the lubricant-impregnated porous surface has a limitation of lubricant depletion by external flow of fluids. Therefore, extensive efforts to improve the durability of lubricant-impregnated surface are required for practical applications.

Evaluation of an electrical impactor with porous metal substrate (다공성 금속판을 이용한 전기적 임팩터의 평가)

  • Jeong Jeong-Seon;Gwon Sun-Park;Lee Gyu-Won
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.276-277
    • /
    • 2002
  • One of drawbacks of the inertial impactor measurement is the required long sampling time (Keskinen et al., 1992). In a gravimetric method, an impaction substrate must be weighed and placed on the corresponding collection plate before being assembled. After sampling, the inertial impactor is disassembled and the collection plate is weighted again. The sampling time depends on the sampled particle mass because the collected particle mass must be sufficiently high to be measured by a sensitive microbalance. (omitted)

  • PDF

On the Thermal Boundary Conditions at the Interface Between the Porous Medium and the Impermeable Wall (다공성 매질과 비투과성 벽면 사이의 경계면에 대한 열적 경계 조건)

  • Kim, Deok-Jong;Kim, Seong-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.12
    • /
    • pp.1635-1643
    • /
    • 2000
  • The present work investigates a heat transfer phenomenon at the interface between a porous medium and an impermeable wall. In an effort to appropriately describe the heat transfer phenomenon at the interface, the heat transfer at the interface between the microchannel heat sink, which is an ideally organized porous medium, and the finite-thickness substrate is examined. From the examination, it is clarified that the he heat flux distribution at the interface is not uniform for the impermeable wall with finite thickness. On the other hand, the first approach, based on the energy balance for the representative elementary volume in the porous medium, is physically reason able. When the first approach is applied to the thermal boundary condition, and additional boundary condition based on the local thermal equilibrium assumption at the interface is used. This additional boundary condition is applicable except for the very th in impermeable wall. Hence, for practical situations, the first approach in combination with the local thermal equilibrium assumption at the interface is suggested as an appropriate thermal boundary condition. In order to confirm our suggestion, convective flows both in a microchannel heat sink and in a sintered porous channel subject to a constant heat flux condition are analyzed. The analytically obtained thermal resistance of the microchannel heat sink and the numerically obtained overall Nusselt number for the sintered porous channel are shown to be in close agreement with available experimental results when our suggestion for the thermal boundary conditions is applied.

Smart Particles Containing Multiple Rugate-structured Photonic Crystal

  • Jang, Seunghyun
    • Journal of Integrative Natural Science
    • /
    • v.5 no.4
    • /
    • pp.253-256
    • /
    • 2012
  • The rugate porous silicons containing multiple photonic band gaps have been generated by applying a composite waveform summed three computer-generated pseudo-sinusoidal current waveforms and exhibit three sharp photonic band gaps in the optical reflectivity spectrum. Generated multiple rugate porous silicons display three rugate peaks corresponding to the each of the sine components varied from 0.42, 0.36, and 0.30 Hz, with a spacing of 0.06 Hz between each sine component. The resulting rugate PSi films have been removed from the silicon substrate by applying an lift-off current and are then made into particles by ultrasono-method in a organic solution. The sensing experiments using these particles for organic solvents such as toluene, hexane, acetone, and methanol have been achieved. Condensing of organic vapors in the pores increases the refractive indices of entire particle which results a red shift in the photonic peaks.

Application of Polymer Brush to Enzyme-Multilayered Porous Hollow-Fiber Membrane

  • Kawakita Hidetaka;Uezu Kazuya;Tsuneda Satoshi;Saito Kyoichi;Tamada Masao;Sugo Takanobu
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.11a
    • /
    • pp.142-145
    • /
    • 2004
  • Anion-exchange porous hollow-fiber membranes with a thickness of about 1.2 mm and a pore size of about $0.30{\mu}m$ were used as a supporting matrix to immobilize cycloisomaltooligosaccharide glucanotransferase (CITase). CITase was immobilized to the membrane via anion-exchange adsorption and by subsequent enzymatic cross-linking with transglutaminase, the amount of which ranged from 3 to 110 mg per g of the membrane. The degree of enzyme multilayer binding was equivalent to 0.3 to 9.8. Dextran, as the substrate, was converted into seven- to nine-glucose-membered cycloisomaltooligosaccharides (CI-7, -8, and -9) at a maxi mum yield of $28\%$ in weight at a space velocity of 10 per hour during the permeation of $2.0(w/w)\%$ dextran solution across the CITase-immobilized porous hollow-fiber membrane.

  • PDF

Nonlocal strain gradient model for thermal stability of FG nanoplates integrated with piezoelectric layers

  • Karami, Behrouz;Shahsavari, Davood
    • Smart Structures and Systems
    • /
    • v.23 no.3
    • /
    • pp.215-225
    • /
    • 2019
  • In the present paper, the nonlocal strain gradient refined model is used to study the thermal stability of sandwich nanoplates integrated with piezoelectric layers for the first time. The influence of Kerr elastic foundation is also studied. The present model incorporates two small-scale coefficients to examine the size-dependent thermal stability response. Elastic properties of nanoplate made of functionally graded materials (FGMs) are supposed to vary through the thickness direction and are estimated employing a modified power-law rule in which the porosity with even type of distribution is approximated. The governing differential equations of embedded sandwich piezoelectric porous nanoplates under hygrothermal loading are derived through Hamilton's principle where the Galerkin method is applied to solve the stability problem of the nanoplates with simply-supported edges. It is indicated that the thermal stability characteristics of the porous nanoplates are obviously influenced by the porosity volume fraction and material variation, nonlocal parameter, strain gradient parameter, geometry of the nanoplate, external voltage, temperature and humidity variations, and elastic foundation parameters.

탈질 조건에서 투과매질 내 미생물 성장에 관한 연구

  • 최영화;오재일;배범한
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.366-369
    • /
    • 2002
  • Subsurface biobarrier technology has potential applications to contain contaminated groundwater and/or to degrade toxic pollutants in groundwater. Most biobarrier studies were conducted under aerobic condition, however there were several obstacles to make aerobic condition. Thus, In this study, we examined biobarrier formation under denitrifying condition by using nitrate as an electron acceptor. Experiments were performed with a sand column inoculated with activated sludge from the nearby WWTP. The substrate medium was pumped to the sand column in an upflow mode. During the low substrate loading rate period, the extent of reduction rate in hydraulic conductivity was found similar throughout the column, and permeability became relatively stable after couple of days. However, during the high substrate loading rate period, the column demonstrated a gradient of permeability reduction, with the greatest reduction in sections nearest the column inlet. Rapid growth of microorganisms near the column inlet resulted in the unbalanced reduction of hydraulic conductivity throughout the sand column. As a result, at this denitrifying condition the thickness of biobarrier could be controlled by adjusting the medium conditions of microbial growth.

  • PDF

Synthesis of zeolite MFI films on alumina and silicon supports using seed crystals (알루미나와 실리콘 지지체에 종자결정에 의한 제올라이트 MFI 필름의 합성)

  • Ko, Tae-Seog
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.18 no.1
    • /
    • pp.38-44
    • /
    • 2008
  • Contiuous c-oriented zeolite MFI films $(<35{\mu}m)$ were prepared by hydrothermal secondary growth of silicalite-1 seed crystal in the surface of alumina porous substrate and silicon substrate. The supported films were characterized with scanning electron microscopy and X-ray diffraction. Effect of substrate surface roughness were investigated and a mechanism for c-oriented film formation and characteristic dom-like defects formation which is observed after seeding growth was discussed. The roughness of substrate plays an important role.

Hydrogen sensing of Nano thin film and Nanowire structured cupric oxide deposited on SWNTs substrate: A comparison

  • Hoa, Nguyen Duc;Quy, Nguyen Van;O, Dong-Hun;Wei, Li;Jeong, Hyeok;Kim, Do-Jin
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.05a
    • /
    • pp.52.1-52.1
    • /
    • 2009
  • Cupric oxide (CuO) is a p-type semiconductor with band gap of ~1.7 eV and reported to be suitable for catalysis, lithium-copper oxide electrochemical cells, and gas sensors applications. The nanoparticles, plates and nanowires of CuO were found sensing to NO2, H2S and CO. In this work, we report about the comparison about hydrogen sensing of nano thin film and nanowires structured CuO deposited on single-walled carbon nanotubes (SWNTs). The thin film and nanowires are synthesized by deposition of Cu on different substrate followed by oxidation process. Nano thin films of CuO are deposited on thermally oxidized silicon substrate, whereas nanowires are synthesized by using a porous thin film of SWNTs as substrate. The hydrogen sensing properties of synthesized materials are investigated. The results showed that nanowires cupric oxide deposited on SWNTs showed higher sensitivity to hydrogen than those of nano thin film CuO did.

  • PDF

Highly Ordered TiO2 nanotubes on pattered Si substrate for sensor applications

  • Kim, Do-Hong;Shim, Young-Seok;Moon, Hi-Gyu;Yoon, Seok-Jin;Ju, Byeong-Kwon;Jang, Ho-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.66-66
    • /
    • 2011
  • Anodic titanium dioxide (TiO2) nanotubes are very attractive materials for gas sensors due to its large surface to volume ratios. The most widely known method for fabrication of TiO2 nanotubes is anodic oxidation of metallic Ti foil. Since the remaining Ti substrate is a metallic conductor, TiO2 nanotube arrays on Ti are not appropriate for gas sensor applications. Detachment of the TiO2 nanotube arrays from the Ti Substrate or the formation of electrodes onto the TiO2 nanotube arrays have been used to demonstrate gas sensors based on TiO2 nanotubes. But the sensitivity was much lower than those of TiO2 gas sensors based on conventional TiO2 nanoparticle films. In this study, Ti thin films were deposited onto a SiO2/Si substrate by electron beam evaporation. Samples were anodized in ethylene glycol solution and ammonium fluoride (NH4F) with 0.1wt%, 0.2wt%, 0.3wt% and potentials ranging from 30 to 60V respectively. After anodization, the samples were annealed at $600^{\circ}C$ in air for 1 hours, leading to porous TiO2 films with TiO2 nanotubes. With changing temperature and CO concentration, gas sensor performance of the TiO2 nanotube gas sensors were measured, demonstrating the potential advantages of the porous TiO2 films for gas sensor applications. The details on the fabrication and gas sensing performance of TiO2 nanotube sensors will be presented.

  • PDF