• Title/Summary/Keyword: Porosities

Search Result 366, Processing Time 0.026 seconds

Variations of Speed of Sound and Attenuation Coefficient with Porosity and Structure in Bone Mimics (뼈 모사체에서 다공율 및 구조에 대한 음속 및 감쇠계수의 변화)

  • Kim, Seong-Il;Choi, Min-Joo;Lee, Kang-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.29 no.6
    • /
    • pp.388-394
    • /
    • 2010
  • In the present study, polyacetal bone mimics with circular cylindrical pores were used to investigate variations of speed of sound and attenuation coefficient with porosity and microarchitecture in bone. The speed of sound and attenuation coefficient of the 6 bone mimics with porosities from 0 % to 65.9 % were measured by a through-transmission method in water, using a pair of broadband, unfocused transducers with a diameter of 12.7 mm and a center frequency of 1.0 MHz. Independently of the structural properties of the bone mimics, the speed of sound decreased almost linearly with the increasing porosity. The attenuation coefficient measured at 1.0 MHz exhibited linear or nonlinear correlations with the porosity, depending on the structural properties of the bone mimics. These results are consistent with those previously published by other researchers using bone samples and mimics, and advances our understanding of the relationships of the ultrasonic parameters for the diagnosis of osteoporosis with the bone density and microarchitecture in human bones.

Investigating wave propagation in sigmoid-FGM imperfect plates with accurate Quasi-3D HSDTs

  • Mokhtar Nebab;Hassen Ait Atmane;Riadh Bennai
    • Steel and Composite Structures
    • /
    • v.51 no.2
    • /
    • pp.185-202
    • /
    • 2024
  • In this research paper, and for the first time, wave propagations in sigmoidal imperfect functionally graded material plates are investigated using a simplified quasi-three-dimensionally higher shear deformation theory (Quasi-3D HSDTs). By employing an indeterminate integral for the transverse displacement in the shear components, the number of unknowns and governing equations in the current theory is reduced, thereby simplifying its application. Consequently, the present theories exhibit five fewer unknown variables compared to other Quasi-3D theories documented in the literature, eliminating the need for any correction coefficients as seen in the first shear deformation theory. The material properties of the functionally graded plates smoothly vary across the cross-section according to a sigmoid power law. The plates are considered imperfect, indicating a pore distribution throughout their thickness. The distribution of porosities is categorized into two types: even or uneven, with linear (L)-Type, exponential (E)-Type, logarithmic (Log)-Type, and Sinus (S)-Type distributions. The current quasi-3D shear deformation theories are applied to formulate governing equations for determining wave frequencies, and phase velocities are derived using Hamilton's principle. Dispersion relations are assumed as an analytical solution, and they are applied to obtain wave frequencies and phase velocities. A comprehensive parametric study is conducted to elucidate the influences of wavenumber, volume fraction, thickness ratio, and types of porosity distributions on wave propagation and phase velocities of the S-FGM plate. The findings of this investigation hold potential utility for studying and designing techniques for ultrasonic inspection and structural health monitoring.

Characterization and performance of post treated PVDF hollow fiber membrane

  • Eman S. Sayed;Hayam F. Shaalan;Magda I. Marzouk;Heba A. Hani
    • Membrane and Water Treatment
    • /
    • v.15 no.2
    • /
    • pp.79-88
    • /
    • 2024
  • Modification of Polyvinylidene fluoride (PVDF) hollow fiber membranes (HFMs) characteristics and performance were investigated via post treatment using different oxidants. sodium hypochlorite (NaOCl), hydrogen peroxide (H2O2) and potassium persulfate (KPS). Fourier transform infrared (FTIR) and Proton nuclear magnetic resonance (1H-NMR) results revealed no structural differences after post treatment. Cross-sectional micrographs show finger-like structures at the outer and inner walls of the HFMs and sponge-like structures in middle, where NaOCl and KPS post treated fibers exhibited a decrease in finger-like structures in addition to aggregates appearing on the surface, consequently leading to an increase in the surface roughness (Ra) from 48 nm to 52.8nm and 56 nm, respectively. Hydrogen peroxide post treatment only was observed to decrease the water contact angle from 98° to 81.4°. It was also observed that the elongation at break and the modulus deceased after NaOCl post treatment from 34.5 to 28.5% and from 19.3 Mpa to 16.6 Mpa, respectively. Moreover, pure water flux after H2O2 post treatment increased from 87.8 LMH/bar to 113 LMH/bar at 0.45 bar, while no changes were detected for the methylene blue dye rejection (74%) between raw and hydrogen peroxide post treated fibers at the same pressure. According to the findings hydrogen peroxide post treated PVDF HFMs have the most uniform surfaces, with almost no alterations in structural and mechanical properties or porosities with enhanced hydrophilicity and pure water flux maintaining appropriate rejection. Therefore, it is considered an efficient surface modifying agent for UF/NF membranes or low-pressure separators.

Repeatability and Reproducibility in Effective Porosity Measurements of Rock Samples (암석시험편 유효공극률 측정의 반복성과 재현성)

  • Lee, Tae Jong;Lee, Sang Kyu
    • Geophysics and Geophysical Exploration
    • /
    • v.15 no.4
    • /
    • pp.209-218
    • /
    • 2012
  • Repeatability and reproducibility in solid weight and effective porosity measurements have been discussed using 8 core samples with different diameters, lengths, rock types, and effective porosities. Further, the effect of temperature on the effective porosity measurement has been discussed as well. Effective porosity of each sample has been measured 7 times with vacuum saturation method with vacuum pressure of 1 torr and vacuum time of 80 minutes. Firstly, effective porosity of each sample is measured one by one, so that it can provide a reference value. Then for reproducibility check, effective porosity measurements with vacuum saturation of 2, 4, and 8 samples simultaneously have been performed. And finally, repeated measurements for 3 times for each sample are made for repeatability check. Average deviation from the reference set in solid weight showed 0.00 $g/cm^3$, which means perfect repeatability and reproducibility. For effective porosity, average deviations are less than 0.07% and 0.05% in repeatability and reproducibility test sets, respectively, which are in good agreement too. Most of porosities measured in reproducibility test lies within the deviation range in repeatability test sets. Thus, simultaneous vacuum saturation of several samples has little impact on the effective porosity measurement when high vacuum pressure of 1 torr is used. Air temperature can cause errors on submerged weight read and even effective porosity, because it is closely related to the temperature, density, and buoyancy of water. Consequently, for accurate measurement of effective porosity in a laboratory, efforts for maintaining air or water temperature constant during the experiment, or a temperature correction from other information are needed.

The Influence of the Landscaping Shade Materials' Porosity on the Mean Radiant Temperature(MRT) of Summer Outdoors (조경용 차양 재료의 공극률이 하절기 옥외공간 평균복사온도에 미치는 영향)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.2
    • /
    • pp.60-67
    • /
    • 2017
  • The purpose of this study was to evaluate the influence of landscaping shade materials' porosity on the Mean Radiant Temperature (MRT) of summer outdoors. The MRTs were measured under seven different types of black membranes with holes of 8mm diameter at different intervals applied on the top of wooden boxes, and compared with those of four additional control plots with or without shade and lateral boxes. The applied porosities were 0.5, 1, 2, 4, 8, 16%, and 32%, and three groups of three shades were compared sequentially from August 13 to September 8, 2016. The MRTs under the shade without lateral block, no shade with lateral block, and shade with lateral block were $33.08^{\circ}C$, $45.80^{\circ}C$, and $42.3^{\circ}C$, respectively, while that of no-shaded no-lateral screen was $44.26^{\circ}C$, based on records from 11:00 AM to 3:00 PM on the days with a peak globe temperature higher than $30^{\circ}C$. An ANCOVA analysis showed that the MRTs under the shades with 0.5, 1, 2, 4, 8, 16%, and 32% porosities were calculated as 43.40, 43.10, 41.49, 40.43, 39.61, $37.91^{\circ}C$, and $38.12^{\circ}C$, respectively, while that in the no shaded control box was $45.8^{\circ}C$. The curve fitted between MRTs and the porosity showed a U-shaped quadratic function with the minimum MRT at 16% practically or 22.5% statistically.

Wear Behaviors of WC-CoCr and WC-CrC-Ni Coatings Sprayed by HVOF (고속화염 용사법으로 제조된 WC-CoCr 코팅과 WC-CrC-Ni 코팅의 내마모 거동)

  • Lee, Seoung Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.204-211
    • /
    • 2020
  • The high-velocity oxy-fuel (HVOF) thermal spraying coating technique has been considered a promising replacement for traditional electrolytic hard chrome plating (EHC), which caused environmental pollution and lung cancer due to toxic Cr6+. In this paper, two types of cermet coatings were prepared by HVOF spraying: WC-CoCr and WC-CrC-Ni coatings. The produced coatings were analyzed extensively in terms of the micro-hardness, porosity, crystalline phase and microstructure using a hardness tester, optical microscopy, X-ray diffraction, and scanning electron microscopy (including energy dispersed spectroscopy (EDS)), respectively. The wear and friction behaviors of the coatings were evaluated comparatively by reciprocating sliding wear tests at 25 ℃, 250 ℃, and 450 ℃. The results revealed correlations among the microstructures, metallic binder matrixes, porosities, and wear performance of the coatings. For example, WC-CoCr coatings showed better sliding wear resistance than WC-CrC-Ni coatings, regardless of the test temperature due to the more homogeneous microstructure, Co-rich, Cr-rich metallic binder matrix, and lower porosity.

Corrosion of castable refractory in H2O/N2/H2S mixed gas at 900℃ (H2O/N2/H2S 혼합가스 분위기 900℃에서 캐스타블 내화물의 부식)

  • Shin, Min;Yoon, Jong-Won;Kim, Chang-Sam
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.27 no.2
    • /
    • pp.99-104
    • /
    • 2017
  • Refractories used in low-rank coal gasification reactors are usually exposed in a highly corrosive $H_2S$ gas at less than $1000^{\circ}C$, and their mechanical properties such as erosion resistance and fracture strength decline with the exposure time. However, the cause of the degradation of the mechanical properties has little reported yet. In this paper, two kinds of castable refractories with different refractoriness had been exposed in a $H_2O/N_2/H_2S$ mixed gas with high $H_2S$ content for 100 hours at $900^{\circ}C$, and the changes of microstructure, crystalline phases and erosion resistance were compared before and after the corrosion test. The weight of the refractories decreases due to the elution of silica in the specimens after the corrosion test. The capillary porosities of the samples are reduced, but the erosion resistance of the samples is fatally weakened after the corrosion test. There also are changes in constituent phases; dmitryivanovite ($CaAl_2O_4$) and amorphous silica ($SiO_2$) disappear, and gypsum ($CaSO_4{\cdot}2H_2OS$) and kaolinite ($Al_2Si_2O_5(OH)_4$) newly appear after the corrosion test. It is obvious that the phase change from dmitryivanovite that works as a binding agent in the castable refractory to gypsum is the main reason of the degradation of the erosion resistance, because the mechanical properties of gypsum are much poorer than those of dmitryivanovite.

Studies on Improved Carbon Cathode Performance in High Rate $Li/SOCl_2$ Cell (고율 방전용 $Li/SOCl_2$ 전지의 카본 양극 개선에 관한 연구)

  • 최정자;조성백;박희숙
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.3
    • /
    • pp.225-232
    • /
    • 1997
  • The performance characteristics of high rate discharge LiSOCl2 cells are highly affected by carbon cathode. During the cell discharge, SOCl2 reduction takes place at the porous carbon cathode, resulting in the precipitation of reaction products, mainly LiCl, within the pores of the substrate. This leads to eventual passivation of the cathode surface and resulting cell failure. To improve the cathode performance, we ex-amined discharge reactions of cathodes (half-cell, 50 mA/$\textrm{cm}^2$ constant current) with various surface density and thickness. The carbon cathode with the optimum capacity for our application is surface density 0.04 g/$\textrm{cm}^2$ and thickness 1.4mm carbon. The carbon cathode with surface density 0.04g/$\textrm{cm}^2$ and thickness 1.4 mm exhibits decreased polarization, increased discharge duration time and capacity (Ah/$\textrm{cm}^2$) as compared with that with surface density 0.04g/$\textrm{cm}^2$ and thickness 0.8mm. The porosities analyses on the two carbon cathodes show that total pore volume of the carbon cathode with thickness 1.4 mm is larger than that with thickness 0.8mm. The increased volume of mesopores (0.05$\mu$m~0.5$\mu$m) and macropores(>0.5$\mu$m) is ob-served with the carbon cathode with thickness 1.4mm as compared with that with thickness 0.8mm, which can be related with the observed capacity increase. We observed LiCl crystals, cubic crystallites and fused, plate-like aggregates, and some elemental S as discharge products by EDS and XRD.

  • PDF

COMPARISON OF SURFACE ROUGHNESS OF VARIOUS LAMINATE VENEER PORCELAIN ACCORDING TO POLISHING METHODS (라미네이트 도재 수복물의 연마 방법에 따른 표면 거칠기의 비교)

  • Kwon, Young-Sook;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.2
    • /
    • pp.246-265
    • /
    • 1996
  • After adjusting glazed surface of laminate veneer porcelain by reduction in the clinical procedure, an additional polishing procedure is required to smoothen the roughened surface by reduction, as it is difficult to glaze it again in the furnace. In this study, four kinds of laminate veneer porcelain were ground with diamond points as done in the clinical procedure. The adjusted porcelain surface was polished with Durawhite stone, Ceramiste points, Exa cerapol, Porcelain polishing wheel, Diamond polishing paste. The degree of surface roughness was evaluated with SEM and profilometer at each step, The self glazed surface and the glazed surface with glazing powder were compared with the polished surface and surface roughness of four kinds of laminate veneer porcelain according to the polishing method and step were obserbed. The following results were obtained : 1. There was no difference in the average surface roughness Ra value and the surface roughness obserbed under SEM according to the polishing methods and steps used, among the four kinds of laminate veneer porcelain including Colorlogic, Exelco, Vintage, and Vitadur alpha product. 2. Due to porosities, the surface in the course of polishing by polishing instruments was rougher than the glazed surface, evaluated with a SEM. 3. Insta-Glaze diamond polishing paste has no statistical difference with self glazed group 1, although it has a lower value in average surface roughness Ra value. 4. Group 2 which was glazed with galzing powder was lowest in view of SEM, but it revealed higher surface roughness Ra value than group 1, the glazed surface and group 8, polished by diamond polishing paste, due to surface waveness. 5. Proper surface smoothness could not be in the surface roughness analysis of SEM and profilometer by Shofu laminate polishing kit composed of Diamond point, Durawhite stone and Ceramiste points. Based on the results of this study, the following conclusions can be drawn. We obtain low surface roughness than glazed surface by polishing instruments, but not perfect results clinically. In order to obtain a perfect clinical result or a surface smoothness comparable to glazed porcelain there is a need for further improvement of porcelain materials, condensa-tion techniques, polishing instruments and polishing methods. Furthermore card should be taken not to breakdown the glazed surface during the clinical and laboratory procedure.

  • PDF

Experimental Study on the Hydrodynamic Dispersion of Contaminants in Geologic Media : Adsorption and Diffusion of Sr and Cr-EDTA in Granitic Rocks (수리지질계에서 지질매체에 따른 오염물질의 수리분산에 관한 실험적 연구 : 화강암질암에서 Sr과 Cr-EDTA의 흡착 및 확산에 관한 연구)

  • Chang, Ho-Wan;Lee, Kwang-Sik
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.1 no.2
    • /
    • pp.105-112
    • /
    • 1994
  • To investigate the migration behavior of contaminants in rocks. adsorption and diffusion experiments for Sr as a sorbing contaminant and for Cr-EDTA as a non-sorbing contaminant were carried out on granitic rocks. The Sr adsorption on separated minerals and crushed rocks tends to slightly increase with increasing pH. It also greatly decreases with the increase of ionic strength in NaCl solution. Among separated minerals, biotite and sericite have adsorbed much more amount of Sr than other rock-forming minerals, such as quartz, plagioclase, and potassic feldspar, because the specific surfaces and cation exchange capacities of phyllosilicates are generally much greater than those of the other rock-forming minerals. The intrinsic diffusion coefficients of Cr-EBTA for granitic rocks differ little from those of Sr. This indicates that they are independent of water-rock interactions. Experimental data show that the intrinsic diffusion coefficients are positively correlated with the porosities of the rocks. They are close to the theoretically predicted values, especially in pre-steady state diffusion region, with the increase of rock sample thickness.

  • PDF