• 제목/요약/키워드: Porcelain materials

검색결과 304건 처리시간 0.026초

Holographic Interferometry를 이용한 하악 구치부 도재소부 전장관용 금속 구조물의 굴곡성향에 대한 연구 (FLEXION EFFECTS OF HEAT TREATMENT AND POST-SOLDRING OF CERAMO-METAL FIXED PARTIAL DENTURE FRAMEWORKS USING HOLOGRAPHIC INTERFEROMETRY)

  • 최진웅;우이형;최부병
    • 대한치과보철학회지
    • /
    • 제34권4호
    • /
    • pp.869-902
    • /
    • 1996
  • Flexion of a metal/ceramic fixed partial denture(EPD) frameworks under function can cause fracture of porcelain or deterioration of the cement seal. This study evaluated the flexion characteristics of three-unit mandibular FPD frameworks, repacing the second pre-molar under compressive load(200g, 400g). Testing was accompished with real-time holographic interferometry, using 6 porcelain fused-to metal frameworks. Tested alloys were non-precious alloy(Heracles, Holland), semi-precious alloy(Degudent U, Germany) and precious alloy(Degudent H, Germany). Changes of the fringe patterns according to the heat treatment(porcelain firing cycle), various loads(200g, 400g), occlusal forms(occlusal porcelain veneering, facial porcelain veneering), various alloys and post-soldering units were compared. Dental study model(Nissan dental products, Inc. D51DP-500A, Japan) and six 3-unit metal/ceramic fixed partial denture frameworks were used as experimental materials. 36 holograms were taken on fixed dental study model by using the 10mW He-Ne laser and real-time holographic interferometry. On the basis of this study, the following conclusions can be drawn : 1. In the frameworks for facial porcelain veneering, the semi-precious alloy framework was least deformed and precious alloy framework, non-precious alloy framework orderly before heat treatment, and the deformation was not shown great difference among three alloys after heat treatment and post-soldering. 2. In the frameworks for occlusal porcelain veneering, the precious alloy framework was greatest deformed and the deformation was not difference between semi-precious alloy framework and non-precious alloy framework before, after heat treatment, and the deformation was not shown great difference among three alloys after post soldering. 3. In the non-precious alloy frameworks for facial porcelain veneering and occlusal porcelain veneering, the deformation was greatly decreased after heat treatment and conversely increased after post-soldering. 4. In the semi-precious alloy framework for facial porcelain veneering, the deformation was not detectable after heat treatment and increased after post-solder. And in the frame-work for occlusal porcelain veneering, the deformation was slightly decreased after heat treatment and increased after post-soldering. 5. In the precious alloy framework for facial porcelain veneering, the deformation was greatly decreased after heat treatment and increased after post-soldering, And in the framework for occlusal porcelain veneering, the deformation was greatly decreased after heat treatment and decreased after post-soldering.

  • PDF

Influence of porcelain veneering on the marginal fit of Digident and Lava CAD/CAM zirconia ceramic crowns

  • Pak, Hyun-Soon;Han, Jung-Suk;Lee, Jai-Bong;Kim, Sung-Hun;Yang, Jae-Ho
    • The Journal of Advanced Prosthodontics
    • /
    • 제2권2호
    • /
    • pp.33-38
    • /
    • 2010
  • PURPOSE. Marginal fit is a very important factor considering the restoration's long-term success. However, adding porcelain to copings can cause distortion and lead to an inadequate fit which exposes more luting material to the oral environment and causes secondary caries. The purpose of this study was to compare the marginal fit of 2 different all-ceramic crown systems before and after porcelain veneering. This study was also intended to verify the marginal fit of crowns originated from green machining of partially sintered blocks of zirconia (Lava CAD/CAM system) and that of crowns obtained through machining of fully sintered blocks of zirconia (Digident CAD/CAM system). MATERIALS AND METHODS. 20 crowns were made per each system and the marginal fit was evaluated through a light microscope with image processing (Accura 2000) at 50 points that were randomly selected. Each crown was measured twice: the first measurement was done after obtaining a 0.5 mm coping and the second measurement was done after porcelain veneering. The means and standard deviations were calculated and statistical inferences among the 2 groups were made using independent t-test and within the same group through paired t-test. RESULTS. The means and standard deviations of the marginal fit were $61.52{\pm}2.88{\mu}m$ for the Digident CAD/CAM zirconia ceramic crowns before porcelain veneering and $83.15{\pm}3.51{\mu}m$ after porcelain veneering. Lava CAD/CAM zirconia ceramic crowns showed means and standard deviations of $62.22{\pm}1.78{\mu}m$ before porcelain veneering and $82.03{\pm}1.85{\mu}m$ after porcelain veneering. Both groups showed significant differences when analyzing the marginal gaps before and after porcelain veneering within each group. However, no significant differences were found when comparing the marginal gaps of each group before porcelain veneering and after porcelain veneering as well. CONCLUSION. The 2 all-ceramic crown systems showed marginal gaps that were within a reported clinically acceptable range of marginal discrepancy.

Accelerating Aging of Transmission Line Porcelain Suspension Insulators by Autoclaving

  • Lee, Won-Kyo;Choi, In-Hyuk;Shin, Koo-Yong;Hwang, Kab-Cheol;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권4호
    • /
    • pp.147-150
    • /
    • 2008
  • Porcelain suspension insulators aged for 1, 5 and 10 years on Korean transmission lines and new insulators are tested for autoclave expansion. The compressive strength of the insulators aged in an autoclave with conditions of $250\;^{\circ}C$ and at 20 atm for 30 minutes, was about $7.6\;kgf/mm^2$, which is close to that measured on insulators aged for 10 years in the field. From simulation results, the cement displacement changed linearly with temperature. At a temperature of $200\;^{\circ}C$, the shear stress was approximately $7\;kgf/mm^2$; a stress that is brought about by a 0.07 % expansion of the cement. It is evident that the cement would fracture at a 0.07 % expansion, because the cement has about 7 to $9\;kgf/mm^2$ flexure strength. A turning point in the shear stress with mechanical load occurred at 0.02 % cement expansion. From an analysis of the porcelain body it is shown that there is sufficient margin of strength to guard against fracture of the porcelain body even for a cement expansion more than 0.12 %.

코팅막의 두께에 따른 기능성 코팅의 내오염 특성 분석 및 전기철도용 애자로의 활용 (Anti-fouling Properties of Functional Coating according to the Film Thickness and its Application to the Insulators for Electrical Railway)

  • 선박문;강현일;최원석;김정현
    • 전기학회논문지P
    • /
    • 제66권2호
    • /
    • pp.94-97
    • /
    • 2017
  • A method of improving the anti-fouling characteristics of porcelain insulators was proposed in this study. Functional coating was performed as a method of reducing the surface contamination of the porcelain insulators. The functional coating was applied on a ceramic substrate, which has the same material as the porcelain insulators. After coating the ceramic substrate 2, 3, 4, and 5 times alternately in the horizontal and vertical directions, the surface characteristics according to the thickness of the coating film were analyzed. The optimal process was selected to coat the surfaces of the post insulators and long rod insulators, which are the representative porcelain insulators. After coating, heat treatment was performed for 1 hour at $200^{\circ}C$ in a furnace to secure the durability of the coating film. Compared to the uncoated insulators, the insulators with the functional coating showed significantly improved anti-fouling characteristics as well as excellent adhesion to the coated insulator surface.

자기애자의 유지 관리를 위한 CNN 기법을 이용한 이미지 분석 (Image Analysis by CNN Technique for Maintenance of Porcelain Insulator)

  • 최인혁;신구용;구자빈;손주암;임대연;오태근;윤영근
    • 한국전기전자재료학회논문지
    • /
    • 제33권3호
    • /
    • pp.239-244
    • /
    • 2020
  • This study examines the feasibility of the image deep learning method using convolution neural networks (CNNs) to maintain a porcelain insulator. Data augmentation is performed to prevent over-fitting, and the classification performance is evaluated by training the age, material, region, and pollution level of the insulator using image data in which the background and labelling are removed. Based on the results, it was difficult to predict the age, but it was possible to classify 76% of the materials, 60% of the pollution level, and more than 90% of the regions. From the results of this study, we identified the potential and limitations of the CNN classification for the four groups currently classified. However, it was possible to detect discoloration of the porcelain insulator resulting from physical, chemical, and climatic factors. Based on this, it will be possible to estimate the corrosion of the cap and discoloration of the porcelain caused by environmental deterioration, abnormal voltage, and lightning.

다목적용 Ag-Pd-Zn-In-Sn계 합금의 모의소성 시 냉각속도의 조절이 소성 및 후열처리에 따른 경도변화에 미치는 영향 (Effect of cooling rate control on the change in hardness of the multi-purpose Ag-Pd-Zn-In-Sn alloy during porcelain firing simulation and post-firing heat treatment)

  • 신혜정;김민정;권용훈;김형일;설효정
    • 대한치과재료학회지
    • /
    • 제44권4호
    • /
    • pp.337-348
    • /
    • 2017
  • 본 연구에서는 소성 시 냉각속도를 조절하는 것과 동시에 소성 후 추가적인 후열처리를 시행하는 것이 후열처리를 시행하지 않는 것보다 합금의 경도 상승에 더욱 효과적인지 알아보고자, 다목적용 Ag-Pd-Zn-In-Sn계 합금을 이용하여 모의소성 시 냉각속도의 조절이 소성 및 후열처리에 따른 합금의 경도변화에 미치는 영향을 조사하여 다음과 같은 결과를 얻었다. 다목적용 Ag-Pd-Zn-In-Sn계 합금의 모의소성 시 냉각속도를 조절함에 따라 합금의 연화가 억제되었다. Stage 0(4단계의 냉각속도 중 가장 빠른 속도; 소성로 챔버가 소성 종료 즉시 전체가 열린 상태로 냉각되는 단계)으로 냉각속도를 조절하여 합금을 소성한 경우, 모의소성 과정에서 합금이 연화되었으며, 적절한 시간동안의 후열처리가 경도상승에 효과적이었다. Stage 3(4단계의 냉각속도 중 가장 느린 속도; 소성로 챔버가 소성완료 후 닫혀진 상태로 냉각되는 상태)으로 냉각속도를 조절하여 합금을 소성한 경우, 모의소성 과정에서 합금이 연화되지 않았으며, 추가적인 후열처리는 합금의 경도를 하강시켰다. Stage 0으로 모의소성 된 합금에서 30분간의 후열처리에 의해 경도가 크게 상승한 원인은 소성에 의해 기지 내로 고용되었던 석출물이 다시 기지 밖으로 활발하게 석출된 것에 기인하였다. Stage 3으로 모의소성 된 합금에서는 후열처리에 의해 석출물이 기지 내로 다시 고용되었고, 새로운 석출상의 생성이 미미하여 후열처리가 경도 상승에 기여하지 못하였다.

도재 수리용 레진의 색안정성에 관한 연구 (A STUDY ON THE COLOR STABILITY OF PORCELAIN REPAIR RESINS)

  • 김난영;진태호
    • 대한치과보철학회지
    • /
    • 제42권2호
    • /
    • pp.133-141
    • /
    • 2004
  • Statement of problem : Porcelain restorations are widely used in restorative dentistry with a high degree of general success. However, porcelain is brittle and may fracture intraorally. Sometimes a repair may be attempted using composite resin and bonding system available. Color stability of porcelain repair resins affects esthetics and prognosis of prosthesis, so that provides important criteria for the choice of porcelain repair resins. Purpose : The purpose of this study was to investigate the color stability of composite resins used widely as porcelain repair system. Materials and method : Composite resins used for this study were Carisma(Kulzer, Germany), Tetric ceram(Ivoclar, Liechtenstein), Filtek Z250(3M, USA), and Arabesk Top(VOCO, Germany). Thirty disc-shaped specimens($10{\times}2mm$) were fabricated from each composite resin. Color changes of specimens after treatment using thermocycling system(KD-TCS30, Kwang-duk F.A. Korea) and after immersion in methylene blue(0.05% by Wt) were measured with colorimeter(Model Tc-6Fx, Tokyo Denshoku Co.) and obtained data were analyzed. Results and Conclusion: The results obtained from this study were as fo11ows. 1. The color change of Filtek Z250 was lesser than those of Tetric ceram and Arabesk Top after thermocycling (12000 times). 2. All of the composite resins in this study showed increase of color change according to increase of thermocycling frequency. 3. After treatment with methylene blue, the color change of Arabesk Top was greater than those of Carisma and Tetric ceram, and Tetric ceram was more stable than others.

Collarless 도재용착주조관의 치경부 도재 변연부의 적합도 및 rounding의 비교 (A STUDY ON LABIOCERVICAL MARGINAL FITNESS AND MARGINAL ROUNDING OF COLLARLESS METAL CERAMIC RESTORATION)

  • 신석훈;이호용
    • 대한치과보철학회지
    • /
    • 제33권2호
    • /
    • pp.198-209
    • /
    • 1995
  • In order to evaluate the fitness and the degree of rounding of porcelain margins in collarless metal cermic restorations, collarless metal ceramic restorations were fabricated with shoulder margins of 90 and 120 degress, each consisting of ten specimens, on master dies through the direct lift technique. And ten metal ceramic restorations with a shoulder 90 degrees were fabricated. All specimens were embedded in resin and sectioned longitudinally. The sections were observed under a stereomicroscope and photographed(${\times}$200). The labial marginal gap between the die and the porcelain margin were measured with a scale. The space between the porcelain margin and the die, that is formed from marginal rounding and cementation were calculated with a computer coordinating area curvimeter. The following results were obtained. 1. There was no statistical difference between the fitness of porcelain margin of collarless metal ceramic restorations and marginal fitness of metal ceramic restoration. 2. There was no statistical difference between a shoulder of 90 and 120 degrees in the fitness of porcelain margin of collarless metal ceramic resorations. 3. Collarless metal ceramic restorations with a shoulder of 90 degrees and 120 degrees showed significantly more labial marginal rounding than metal ceramic restorations. 4. There was no statistical difference between a shoulder of 90 and 120 degrees in rounding of porcelain margin of collarless metal ceramic restorations. According to the results, rounding of porcelain margins can be observed in collarless metal ceramic restorations. Thus, there is a need for improvement in dental materials and techniques to minimize this problem, Furthermore, care should be exercised during the clinical procedure.

  • PDF

Thermal Impact Characteristics by Forest Fire on Porcelain Insulators for Transmission Lines

  • Lee, Won-Kyo;Choi, In-Hyuk;Choi, Jong-Kee;Hwang, Kab-Cheol;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권4호
    • /
    • pp.143-146
    • /
    • 2008
  • In this study the thermal impact characteristics by forest fire are extensively investigated using temperature controlled ovens. The test conditions for thermal impact damage are simulated according to the characteristics of natural forest fire. The test pieces are suspension porcelain insulators made by KRI in 2005 for transmission lines. In the thermal impact cycle tests with $300\;^{\circ}C$ thermal impact gradient (-70 to $230\;^{\circ}C$), cycling in 10 minute periods, no critical failures occurred in the test samples even with long cycle times. But in tests with thermal impact gradient from room temperature to $200-600\;^{\circ}C$, cycling in 10 to 30 minute periods, there were critical failures of the porcelain insulators according to the thermal impact gradient and quenching method. In the case of thermal impact by forest fire, it was found of that duration time is more important than the cycling time, and the initiation temperature of porcelain insulator failures is about $300\;^{\circ}C$, in the case of water quenching, many cracks and fracture of the porcelain occurred. It was found that the thermal impact failure is closely related to the displacement in the cement by thermal stress as confirmed by simulation. It was estimated that the initiation displacement by the thermal impact of $300\;^{\circ}C$ is about 0.1 %. Above 1% displacement, it is expected that the most porcelain insulators would fail.

Composite and Porcelain Laminates and Veneers/Clinical Choice of Materials and Techniques

  • Wei, Stephen-H.
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2002년도 추계학술대회
    • /
    • pp.719-719
    • /
    • 2002
  • Aesthetic and cosmetic dentistry is becoming a major source of the dentists practice and source of income. Patients are demanding dentists to improve and enhance their appearance and function by means of aesthetic contouring and orthodontics and are willing to pay for such services. This creates a challenge for the dental profession to gain more knowledge and skill in this important area of their practice. Ceramic and composite veneers provide a comprehensive solution to the dentition that are severely hypoplastic or deeply stained by the ingestion of tetracycline during tooth development. A large number of dental materials and new techniques are now available that will render extremely satisfactory and beautiful solutions to these previously unsightly dentitions. This presentation will present the most commonly used dental materials and techniques of fabrication of composite and porcelain veneers. Using clinical cases, the step by step cavity preparations.Impression taking, laboratory fabrication, clinical try-in and cementation materials and techniques and repairs of broken veneers as well as long term follow up will be presentedesented

  • PDF