• 제목/요약/키워드: Pond-wetland system

검색결과 46건 처리시간 0.026초

습지와 유수지를 이용한 강우 유출수 처리 (Stormwater treatment using Wetland and Pond)

  • 함종화;윤춘경;구원석
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.575-578
    • /
    • 2003
  • Constructed wetlands have become a popular technology for treating contaminated surface and wastewater. In this study, the field experiment to reduce nonpoint source pollution from watershed runoff during rainy day using wetland and pond. TSS and T-N removal rate of wetland-pond system and pond-wetland system was 91% and 73%, 94% and 70%, respectively and values were same range. $BOD_5$ and T-P removal rate of pond-wetland system (38% and 78%) was higher than wetland-pond system (27% and 62%). overall, pond-wetland system is more useful than wetland-pond system to control NPS.

  • PDF

담수호 수자원보전을 위한 수질정화 연못-습지 시스템의 초기처리수준 (Treatment Efficiency of a Pond-Wetland System for the Water Quality Conservation of Estuarine Lake)

  • 양홍모
    • 한국환경복원기술학회지
    • /
    • 제4권4호
    • /
    • pp.64-71
    • /
    • 2001
  • Treatment efficiency was examined of a pond-wetland system constructed for water quality conservation of Koheung Estuarine Lake over one year after its establishment in July 2000. The system is composed of primary and secondary ponds in series and six wetland cells in parallel. Cattails (Typha angustiflora) were planted in three wetland cells and common reeds (Phragmites australis) in three other cells. Water pumped from Sinyang Stream flowing into the Lake was funneled into primary pond whose effluent was discharged into secondary pond by gravity flow. Effluent from secondary pond was distributed into each wetland cell. SS, $BOD_5$, T-N, and T-P concentrations in influent to primary pond, and effluent from primary pond, secondary pond, and three wetland cells planted with cattails were analyzed for about one year from August 2000 to August 2001. The removal rates at primary pond for SS, $BOD_5$, T-N and T-P were 29%, 30%, 15%, and 36%, respectively. The abatement rates at secondary pond for SS, $BOD_5$, T-N and T-P were 38%, 40%, 30%, and 47%, respectively. The reduction rates measured at three cattail-planted wetland cells for SS, $BOD_5$, T-N and T-P were 54%, 57%, 60%, and 68%, respectively. Considering early stage of the pond-wetland system and inclusion of winter during the research period, its treatment efficiency was rather good. Cattails had not yet grown to dense stands due to initial establishment period, which resulted in slightly lower treatment efficiencies of wetland cells for these pollutants, compared with those of ponds.

  • PDF

연못을 이용한 동절기 인공습지 오수처리수의 추가 처리 (Pond System for Further Polishing of Constructed Wetland Effluent during Winter Season)

  • 윤춘경;전지홍;김민희;함종화
    • 한국농공학회지
    • /
    • 제44권4호
    • /
    • pp.139-148
    • /
    • 2002
  • Pilot study was performed to examine the feasibility of the pond system for further polishing of treatment wetland effluent from December 2000 to June 2001. The wetland system used for the experiment was highly effective to treat the sewage during the growing season, but it was less effective and its effluent was still high to discharge to the receiving water body. Therefore, the wetland effluent may need further treatment to prevent water quality degradation. Pond system could be used to hold and further polish the wetland effluent during the winter season and ots feasibility was evaluated in this study. Additional water quality improvement was apparent in the pond system during winter season, and the pond effluent could be good enough to meet the effluent water quality standards if it is properly managed. Timing of the pond effluent discharge appears to be critical for pond system management because it is a closed system and whole water quality constituents are affected by physical, chemical, and biological pond environments. Once algae started to grow in mid-April, constituents in the pond water column interact each other actively and its control becomes more complicated. Therefore, upper layer of the pond water column which is clearer than the lower layer my need be discharged in March right after ice cover melted. In the experiment, water quality of the upper water column was markedly clear in March than ant other times probably because of freezing-thawing effect. The remaining lower water column could be further treated by natural purification as temperature goes up or diluted with better quality of wetland effluent for appropriate water uses. This study demonstrated the feasibility of pond system for subsequent management of wetland effluent during the winter season, however, more study is needed for field application.

물리적 설계인자가 인공습지의 처리효율에 미치는 영향 (The Effect of Physical Design Parameters on the Constructed Wetland Performance)

  • 함종화;윤춘경;구원석;김형철;신현범
    • 한국농공학회논문집
    • /
    • 제47권5호
    • /
    • pp.87-97
    • /
    • 2005
  • The field scale experiment was performed to examine the effect of physical design parameters on the constructed wetland performance and recommend the feasible design of constructed wetland in Korean polder areas. Four sets (each set of 0.85 ha) of wetland (0.8 ha) and pond (0.08 ha) systems were used. Two different wetland systems, a wetland-pond system and a pond-wetland system, were studied to examine the effect of wetland and pond configuration. And two different length-to-width ratios were used, 2: 1 and 0.8: 1, to examine the effect of aspect ratio. A pond-wetland system was more preferable than a wetland-pond system, and also requires a smaller area than a wetland-pond system or a wetland system to reduce T-P. There was no difference in effluent concentration between the 2:1 system and the 0.8:1 system. Although the linear velocity of the 2:1 aspect was higher than the 0.8:1 aspect, resuspension was not a factor in this study due to a very low linear velocity. From this study and other literature review, it was found that design method of paddy rice field could be applied and expanded to the design of constructed wetland in Korea. Further investigation for the detailed design parameters of constructed wetland needs be continued for design method of paddy rice to be applied in full scale.

담수호 수자원보전을 위한 유역처리 연못-습지 시스템(지역환경 \circled2) (Pond-Wetland System for the Water Resources Conservation of Estuary Lake)

  • 양홍모;최수명;윤광식
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.557-562
    • /
    • 2000
  • Estuary lakes constructed for agricultural water resources development projects have encountered eutrophication problems. Natural water purification function of wetland is considered for nutrient removal from inflowing stream. A constructed wetland was designed and installed for pollutant loading abatement in estuary lake Koheung. Combined pond-wetland system was adopted. In this system primary and secondary ponds and six wetland cells were interconnected. Reed and cattail were selected for wetland vegetation and planted in the wetland cells. In this paper, design criteria of the pond-wetland system in temperate weather zone is presented.

  • PDF

자연정화방법에 의한 오수처리와 농업적 재이용 타당성 검토 (Feasibility Study of Natural Systems for Sewage Treatment and Agricultural Reuse)

  • 윤춘경;정광욱;함종화;전지홍
    • 한국농공학회지
    • /
    • 제45권6호
    • /
    • pp.194-206
    • /
    • 2003
  • A pilot study was performed to examine the feasibility of the pond system for further polishing of treatment wetland effluent to agricultural reuse of reclaimed water. The constructed wetland and pond system was installed in Konkuk University and the effluent from septic tank of school building was used as an influent to the wetland system. The effluent of the wetland was used as an influent to pond systems. The influent concentrations of total coliform(TC), fecal coliform (FC), and E. coli were about $10^5$MPN/100 ml, and they were reduced to less than 10,000 MPN/100 ml on average after wetland treatments, showing over 95 % removal. And they were further reduced to less than 1,000 MPN/100 ml in average, showing over 85∼93 % removal after pond treatment. Turbidity and SS were improved effectively on average and their pond effluent concentration was about 4.5 NTU and 9.8 mg/L in average, respectively Average $BOD^5$ concentrations were also reduced substantially to 9.3 mg/L with about 83 % removal rate after wetland and pond treatment systems. Nutrients removal was relatively low and removal rate for T-N and T-P was less than 43 and 44%, respectively after wetland and pond treatment. Considering stable performance and effective removal of bacterial indicators as well as other water quality parameters, low maintenance, and cost-effectiveness, pond system was thought to be an effective and feasible alternative for agricultural reuse of reclaimed water. This paper describes a preliminary result Iron pilot study and further investigations are recommended on the optimum design parameters before full scale application.

인공습지와 연못시스템을 이용한 오수처리 (Waste Water Treatment Using Constructed Wetland and Pond System)

  • 김민희;윤춘경;함종화
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.470-474
    • /
    • 2001
  • A pilot study was performed at the experimental field of Konkuk University in Seoul, to examine the waste water treatment using constructed wetland and pond system. The effluent of the wetland system in winter often exceeded effluent water quality standards for sewage treatment plant, therefore, pond system could be applied to additional system. As a result, removal rate of $BOD_{5}$, SS was 84.4%, 81.5% and effluent concentration was 4.6mg/L and 5.0mg/L respectively, when surface water of pond system was discharged in March. So we concluded that pond system stored wetland effluent in winter and discharged surface water of pond system in March, so met water quality standard.

  • PDF

Sewage Treatment Using Natural Systems and Effluent Reuse for Crop Irrigation in Small Communities

  • Ham, Jong-Hwa;Yoon, Chun-G.;Jeon, Ji-Hong;Hwang, Ha-Sun
    • 한국농공학회지
    • /
    • 제45권7호
    • /
    • pp.70-82
    • /
    • 2003
  • A pilot study was performed from July 1998 to December 2002, including winter performance, to examine seasonal performance of a constructed wetland and subsequent pond system for treatment of sewage in small communities of Korea. Pond was operated as a intermittent-discharge pond during winter period, and continuous flow system during growing season; its effects was evaluated from December 2001 to April 2003. The subsurface flow (SSF) wetland was satisfactory for treating sewage with good removal efficiency even during the winter period. The wetland effluent concentrations of $BOD_5$ and TSS were often higher in winter than in the growing season, but this was explained by the higher loading rates, rather than lower removal efficiency. The relatively poor-quality wetland effluent was further polished during winter in the pond. The upper layer of the pond water column became remarkably clear immediately after ice melt. In the growing season, ponds could be operated as a continuous flow system to remove nutrients and pathogens, and the effluent of pond could be reused as a supplemental irrigation water without risk of infection by sewage-borne pathogens as well as causing adverse effect on growth and yield. Overall, the wetland system was found to be adequate for treating sewage with stable removal efficiency, and the intermittent-discharge pond was found to be effective for further polishing if necessary. Therefore, the combination of a wetland and subsequent pond system and reuse of effluent as crop irrigation water is recommended as a practical alternative to treat sewage in Korean small communities, and partial discharge of pond water in March is suggested.

습지와 유수지를 이용한 하구담수호 유입하천의 수질개선 (Water Quality Improvement of Inflow Stream in Estuary using Wetland and Pond)

  • 구원석;윤춘경;함종화
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.587-590
    • /
    • 2003
  • Wetland systems are widely accepted natural water purification systems around the world in nonpoint sources pollution control. In this study, the field experiment to reduce nonpoint source pollution loadings from agricultural drainage and polluted stream waters using wetland and pond system was performed. The removal rate of $BOD_5$, TSS, T-N and T-P during growing season was 7.2%, 64.3%, 57.0%, and 60.3%, respectively. And removal rate of $BOD_5$, TSS, T-N and T-P during winter was -49.5%, -56.1 %, 30.5%, and 47.1%, respectively. In this study, pond-wetland system is more effective than wetland-pond system to remove nutrient.

  • PDF

간척지 연못-습지 시스템의 질소.인 초기 처리수준 및 식물성장 (Treatment Efficiency and Plant Growth of Early Stage of Pond-Wetland System at Estuary Lake)

  • 양홍모;최수명;윤광식
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2001년도 학술발표회 발표논문집
    • /
    • pp.426-430
    • /
    • 2001
  • Treatment efficiency and plant growth of a combined Pond-Wetland system was investigated. The system is composed of primary and secondary ponds and six wetland cells. Reed and cattail were planted as vegetation of wetland cells. The removal rates of BOD, SS, T-N, and T-P were 40%, 41%, 30%, and 47% at the secondary pond, respectively. The system removal rates measured at the last wetland cell were 57%, 54%, 60%, and 68% for BOD, SS, T-N, and T-P, respectively.

  • PDF