• 제목/요약/키워드: Polymer housing

검색결과 60건 처리시간 0.026초

FRP 보강 폴리머 모르터를 이용한 돈사 바닥재 개발 (Development of Polymer Mortar Floor Members for Swine Housing Reinforced by FRP)

  • 유능환
    • 한국농공학회지
    • /
    • 제42권4호
    • /
    • pp.124-129
    • /
    • 2000
  • The objective of this study is to develop a polymer mortar floor members for wine housing with high strength and durability using unsaturated polyester resin to complement defects of conventional cement concrete. Physical and mechanical properties of the polymer mortar floor members for swine housing are also investigated. Specimens with different panel thickness and FRP reinforcement are prepared, tested, and analyzed with respect to structural behaviors. Cracking moment is mostly affected by the thickness and reinforced FRP. Data of the study can be applied to the designing and planning of floor members for swine housing.

  • PDF

열-기계적 스트레스가 폴리머 피뢰기의 전기적 특성에 미치는 영향 (Effect of Thermal Mechanical Stresses on Electrical Characteristics of Polymer Housed Surge Arresters)

  • 조한구;유대훈
    • 한국전기전자재료학회논문지
    • /
    • 제20권6호
    • /
    • pp.555-560
    • /
    • 2007
  • This paper describes the results of a study on the sealing integrity of polymer housed surge arrester based on the thermal mechanical test. The polymer housed surge arrester employs silicone insulating materials for its housing, instead of the conventional porcelain housing. The polymer housed surge arresters exhibited the highest sealing integrity because it is not air volume between the FRP(fiber reinforced plastics) module and the silicone housing. In accordance, the sealing integrity of station class surge arresters is investigated with moisture ingress test. And, the influence of sealing integrity was evaluated through such as measurement of the deflection, reference voltage, leakage current. In electrical characteristics, reference voltage decreased in the range of $16.45{\sim}16.15\;kV$ with after thermal mechanical test. In contrary, despite the continued moisture ingress, the polymer housed surge arresters exhibited almost the same leakage current value and the resistive leakage current has risen slightly. As a results, It was thought that the polymer housed surge arresters shows good stability with sealing integrity.

가공개폐기용 폴리머 부싱 개발 (Development of Polymer Bushing for Overhead Line Switch)

  • 최경선;주종민;이철호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.787-790
    • /
    • 2001
  • Polymer bushing used for overhead line switch was designed and investigated. Requirements of electrical ratings such as partial discharge, ac withstand voltage, impulse voltage and material properties were proposed in accordance with IEEE 386 and pre-standard (PS) 151-146∼147, 170∼180 of KEPCO. The polymer bushing consists of an internal epoxy bushing and external housing made of EPDM rubber. The rubber housing was molded with mold cone. Therefore, the polymer bushing offers several advantages like light weight, good sealing properties, easy installation and excellent performance in contamination. Electric field analysis was also introduced in order to verify the reliability of the design.

  • PDF

18kV 배전용 피뢰기의 구조에 따른 온도특성 (Temperature Characteristics with Structure of 18kV Lightning Arresters for Distribution System)

  • 조한구;윤한수;이운용;김석수;최인혁
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1125-1128
    • /
    • 2004
  • This paper presents the temperature characteristics with structure of 18 kV lightning arresters for distribution. Three types of polymer arresters were fabricated and ceramic type arrester was also ready to investigate. Below $100^{\circ}C$, three types of polymer arresters exhibited almost the same leakage current value, but above $100^{\circ}C$, polymer arrester that arrester module was injected into polymer housing with grease exhibited the highest leakage current and the arrester with the lowest leakage current was the arrester that silicon rubber was directly injected to arrester module. The rising of leakage current of polymer arrester with grease was because of existing grease between FRP winding and silicon housing, and reducing the insulation characteristics of the grease. All polymer arresters exhibited the same temperature characteristics but ceramic typr arrester was slower than polymer arrester in heat emission despite lowest leakage current. It was thought that the air layer between ZnO varistor blocks and ceramic housing prevented the heat emission. However, in spite of the difference of the structure, the variation of the surface temperature of all arresters exhibited the same result.

  • PDF

폴리머 피뢰기의 모듈 설계 및 성능에 관한 연구 (A Study on Module Design and Performance of Polymer Arrester)

  • 조한구;천종욱;강영길
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마연구회
    • /
    • pp.108-111
    • /
    • 2003
  • The main objective of this paper is to module design and pressure relief test a new type of polymer gapless surge arrester for power distribution line. Metal oxide surge arrester for most electric power system applications, power distribution line and electric train are now being used extensively to protect overvoltage due to lightning. Surge arresters with porcelain housing must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of gapless elements in a surge arrester occurs due to flashover, fault short current flows through the arrester and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock, pressure rise, etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion.

  • PDF

폴리머 피뢰기의 고장전류에 대한 방압 설계기술에 관한 연구 (Study on the relief design for the fault current of polymer arrester)

  • 김인성;박효열;조한구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1717-1719
    • /
    • 1999
  • The chief advantage of polymer arrester. from design of pressure relief, anti-contamination, electrical failure was reduced by outdoor polymer housing. In the first for development of pressure relief design for polymer arrester, fault current and surge were studied through experiments of electrical. Designed the FRP inner tube and unit modules for pressure relief housing. Tested the performance of unit modules for pressure relief of polymer arrester, and the result was successful. The pressure relief of polymer arrester depend on design pattern of diamond shape and ellipse. Study on the pressure relief of FRP inner tube for outdoor polymer arrester. Designed and manufactured FRP inner tube of polymer arrester. Tested the fault current of polymer arrester per 10 kA, 10 cycle.

  • PDF

폴리머 housing형 피뢰기의 개발과 특성 평가 (Development and Characteristics Evaluation of Polymer Housing Type Arresrter)

  • 조한구;김인성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 춘계학술대회 논문집
    • /
    • pp.82-85
    • /
    • 1997
  • This paper describes the development of new type arrester for 22.9kV class distribution lines, with polymer insulating materials applied to their housings. The new arrester employs silicone insulating material for its housing, instead of the conventional porcelain housing, aiming at reduction in size and weight and explosion proof against internal short circuit failure. And, since the design of sheds is not restricted. it is possible to provide a long surface leakage distance per strike length and improve anti-contamination performance.

  • PDF

배전용 고분자 피뢰기의 하우징과 전극구조 (Study on the Housing and Electrode of Polymer Arrester)

  • 김인성;조한구;황명근;김광호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1676-1678
    • /
    • 1996
  • This paper introduced and study : new material electrode structures(cap type sealing structure, knuckle type electrode, stress relief housing electrode), and insulating housing which supporting shed and containg MOV(ZnO) and sub parts, of polymer arrester.

  • PDF

154kV 송전용 폴리머 애자의 산불에 대한 누설전류 및 온도 특성 (A Characteristics of Leakage Current and Temperature on Forest Fire of EHV Polymer Insulator for 154KV T/L)

  • 최인혁;최장현;박준호;이동일;김태영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.517-518
    • /
    • 2006
  • In this paper, to understand the effect of forest fires on polymer insulators for transmission lines, it was observed the aging of the housing surface of the polymer insulators. And, this paper shows the way how to create the artificial field testing in order to simulate forest fire. As the results of, maximum leakage current peaks by influence of flame increased from 1[mA] to 1.4[mA], and SEM results show the inorganic component on the housing surface because the organic component matters disappeared. Therefore, the case of exposed by forest fire, polymer insulator can be used in the early stage, but an exchange needs active countermeasure to be stabilize power delivery.

  • PDF

배전선로용 폴리머 피뢰기의 모듈 설계/제조 및 성능 (Relief Performance of Fault Current and Design/Manufacturing of Polymer Arresters for Power Distribution)

  • 조한구;윤한수;장태봉;최인혁
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집
    • /
    • pp.175-179
    • /
    • 2005
  • The main objective of this paper is to module design and pressure relief test a new type of polymer gapless surge arrester for power distribution line. Metal oxide surge arrester for most electric power system applications, power distribution line and electric train are now being used extensively to protect overvoltage due to lightning. Surge arresters with porcelain housing must not have explosive breakage of the housing to minimize damage to other equipment when subjected to internal high short circuit current. When breakdown of gapless elements in a surge arrester occurs due to flashover, fault short current flows through the arrester and internal pressure of the arrester rises. The pressure rise can usually be limited by fitting a pressure relief diaphragm and transferring the arc from the inside to the outside of the housing. However, there is possibility of porcelain fragmentation caused by the thermal shock, pressure rise, etc. Non-fragmenting of the housing is the most desired way to prevent damage to other equipment. The pressure change which is occurred by flashover become discharge energy. This discharge energy raises to damage arrester housing and arrester housing is dispersed as small fragment. Therefore, the pressure relief design is requested to obstruct housing dispersion.