• Title/Summary/Keyword: Polymer flow

Search Result 753, Processing Time 0.029 seconds

A Numerical Analysis of Polymer Flow in Thermal Nanoimprint Lithography

  • Kim, Nam-Woong;Kim, Kug-Weon;Lee, Woo-Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.3
    • /
    • pp.29-34
    • /
    • 2010
  • Nanoimprint lithography (NIL) is an emerging technology enabling cost effective and high throughput nanofabrication. To successfully imprint a nanometer scale patterns, the understanding of the mechanism in nanoimprint forming is essential. In this paper, a numerical analysis of polymer flow in thermal NIL was performed. First, a finite element model of the periodic mold structure with prescribed boundary conditions was established. Then, the volume of fluid (VOF) and grid deformation method were utilized to calculate the free surfaces of the polymer flow based on an Eulerian grid system. From the simulation, the velocity fields and the imprinting pressure for constant imprinting velocity in thermal NIL were obtained. The velocity field is significant because it can directly describe the mode of the polymer deformation, which is the key role to determine the mechanism of nanoimprint forming. Effects of different mold shapes and various thicknesses of polymer resist were also investigated.

The Effects of Polymer Degradation on the Drag Reduction in CWM Transport (CWM 관수송의 저항 감소현상에 있어서 고분자첨가제의 퇴화 영향에 관한 연구)

  • 송창환;김종보;김인석;최형진
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.10
    • /
    • pp.1908-1914
    • /
    • 1992
  • A significant drag reduction in the turbulent flow of CWM(coal Water Mixture) adding minute amounts of high molecular weight polymer additives has been obtained and it was compared with pure CWM.However, the rate of drag reduction could come down with flow time, which is caused by polymer degradation, The rate of drag reduction and polymer degradation is affected by polymer type, concentration, molecular weight, and flow velocity. In the present investigation, these important parameters were evaluated for their influences on polymer degradation in order to find out stable conditions for CWM transportation with time. It was necessary to determine the more effective type of polymer additives to guarantee the optimum conditions for CWM transport. Experiments were undertaken with a test section of pipe diameter 9.8mm and pipe length 3500mm(L/D=357) in a closed loop, and polyacrylamide and polyetylene oxide were utilized as polymer additives. The tests were carried out under the conditions of 200, 400, 700ppm of polymer concentrations. CWM concentrations utilized were 5% and 10% with flow velocities of 4.9m/s and 6.1m/s. Experimental data show that polyehylene oxide degraded faster than polyacrylamide in CWM transport, and polyacryamide is considered to be a more effective candidate as additive for long time-CWM transport. Polymer degradation is also found to be more likely at lower polymer concentrations, at higher flow velocities, and higher CWM concentrations.

Study on the flow characteristics of the polymer reactors (고분자 반응기의 내부 유동 특성에 관한 연구)

  • Choi D. S.;Im Y. H.;Han S. P.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2002.05a
    • /
    • pp.134-139
    • /
    • 2002
  • This study is focused on investigating the characteristics of internal flow of the polymer reactor and its effect on the polymer quality. Four types of polymer reactor which have different kind of impeller, baffle and operation condition were calculated by CFD. Fluent 6 have been used to simulate mixing phenomena of reactor. According to the comparison of computational results and SEM photographs of polymer particle, distribution of turbulent dissipation rate greatly influences on the quality of polymer. So, distribution of turbulent dissipation rate to be important criterion to predict polymer quality.

  • PDF

A Study on the Evaluation of Hydrodynamic Performance of Trileaflet Prosthetic Heart Valves (삼엽식 인공판막의 수력학적 성능평가에 관한 연구)

  • 김혁필;이계한
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.147-156
    • /
    • 1997
  • Various prosthetic heart valves have been developed and used clinically, but they have problems, such as thrombogenecity, hemoltsis, high cost and low durability. New types of trileaflet polymer heart valves have been developed in order to use them as inlet and outlet valves in a ventricular assist device. The aim of this study is to determine the hydrodynamic effectiveness of the newly designed trileaflet polymer valves and their feasibility for temporary use in the blood pumps. Trileaflet polymer valves are made of polyurethane, because of its good blood compatibility, high tonsil strength and good resistance to fatigue. An in vitro experimental investigation was perf'ormed in order to ev91ua1e hydrodynamic performance of the trileaflet polymer valves having different design and fabrication tech- niques. The St. Jude Medical valve (SJMV) and floating-type monoleaflet polymer valve (MLPV) were also tested The pressure drop across the valve, leakage volume, and the flow patterns mere investigated for valves. The result of comparative tests showed that the trileaflet polymer valves had a better hydrodynamic performance than the others. TPV which has two stable membrane shape showed the lowest back flow. The pressure hops of TPVs were lower than that of MLPV, but slightly higher than SJMV. The hydrodynamic performance of valves under the pulastile flow showed the similar results as steady flow. The velocity profiles and turbulent intensities were measured at the distal sites of valves using a hot-film anemometer. Central flow was maintained in trileaflet polymer valves, and the maximum turbulent intensities were lower in TPVs comparing to MLPV.

  • PDF

A flow phenomenon of aquaous polymer solution in couette flow of concentric cylinder with wide circular (넓은 환상간극을 가진 동심원통속의 couette 흐름에서 고분자수용액의 유동현상)

  • 권혁칠;이성노;정진도
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.15 no.3
    • /
    • pp.81-88
    • /
    • 1993
  • This report describes the experimental research on the flow phenomena of the aq uaous polymer solution within the Cuette flow of the concentric, cylinders type with a wide circular gap. We have investigated the phenomena of the fluid flow through torque measuring in the system that the inner cylinder is stationary and the outer one is rotating. Geometrical parameters of the system are the gap ratio of t/R$_{0}$=0.2 and Aspect ratio of l/t=100. The torque increases considerably in about 420-480RPM, So, it is considered a turbulent transition boundary, the higher plymer concentration is, the lower torque value is and the higher transition Reynolds number is. In each of the polymer concentration, the unstable boundary of torque, that is, idiosyncrasies of torque is observed around 220-280RPM. and the boundary is looked upon as a resonant vibration which is caused by the inner cylinder and tortional vibration of torque sensor.r.

  • PDF

Micro and macro in the dynamics of dilute polymer solutions: Convergence of theory with experiment

  • Prakash, J. Ravi
    • Korea-Australia Rheology Journal
    • /
    • v.21 no.4
    • /
    • pp.245-268
    • /
    • 2009
  • Recent developments in dilute polymer solution rheology are reviewed, and placed within the context of the general goals of predicting the complex flow of complex fluids. In particular, the interplay between the use of polymer kinetic theory and continuum mechanics to advance the microscopic and the macroscopic description, respectively, of dilute polymer solution rheology is delineated. The insight that can be gained into the origins of the high Weissenberg number problem through an analysis of the configurational changes undergone by a single molecule at various locations in the flow domain is discussed in the context of flow around a cylinder confined between flat plates. The significant role played by hydrodynamic interactions as the source of much of the richness of the observed rheological behaviour of dilute polymer solutions is highlighted, and the methods by which this phenomenon can be incorporated into a macroscopic description through the use of closure approximations and multi scale simulations is discussed.

Hydrodynamic Investigation of a Floating-type Monoleaflet Polymer Valve under Steady Flow Condition (정상유동에서 유동형 단엽폴리머 인공판막의 수력학적 성능평가)

  • 김준우;박복춘
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.49-60
    • /
    • 1996
  • An experimental investigation was performed under steady flow condition to assess hydrodynamic performance of floating-type monoleaflet polymer valves (MLPV) withdifferent leaflet thickness. The St. Jude Medical valve (SJMV) was also used for comparison test. Pressure drops of MLPVS are larger than those for other types of polymer valves and mechanical valves. Furthermore, the thicker is the leaflet thickness of the polymer valve, the larger are the corresponding pressure drop. The velocity profiles for MLPs reveal a large reversed flow region downward to the valve position. The maximum wall shear stresses of MLPVS at a flow rate of $30{\ell}$/min are in the range 50-130 dyn/$cm^2$, and the corresponding maximum Reynolds shear stresses are in the range of 100-500 dyn/$cm^2$, respectively, which are beyond the allowable limit clinically. In contrast, floating-type monoleaflet polymer valves show better hydrodynamic performance in leakage volume. From the designing point of view, it may be concluded that the optimum thickness of leaflet for better hydrodynamic performance is one of the Important parameters.

  • PDF

Hydrodynamic Investigation of a Floating-type Monoleaflet Polymer Heart Valve under Steady Flow Condition (정상유동에서 유동형 단엽폴리머 인공심장판막의 수력학적 성능평가)

  • Pak, Bock-Choon;Kim, Joon-Woo;Baek, Byoung-Joon;Min, Byoung-Goo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.05
    • /
    • pp.241-246
    • /
    • 1995
  • An experimental investigation was performed under steady flow condition to assess hydrodynamic performance of floating-type monoleaflet polymer valves (MLPV) with different leaflet thickness. The St. Jude Medical valve (SJMV) was also used for comparison tests. Pressure drops of MLPVs are larger than those for other types of polymer valves and mechanical valves. Furthermore, the thicker is the leaflet thickness of a polymer valve, the larger arc the corresponding press drop. The velocity profiles for MLPV reveal a large reversed flow region downward to the valve position. The maximum wall shear stresses of MLPVs at a flow rate of 30 l/min are in the range $54-130\;dyn/cm^2$, and the corresponding maximum. Reynolds shear stresses are in the range of $100-500\;dyn/cm^2$, respectively. Both arc beyond the allowable limit clinically. In contrast, floating-type monoleaflet polymer valves show better hydrodynamic performance in leakage volume. From the designing point of view, it can be concluded that the optimum thickness of leaflet for better hydrodynamic performance is one of the important parameters.

  • PDF

The Effect of Flow Patterns with Polymer Additivies From Two Phase Flow at Vertical up Ward in Circular Tube (원관내 수직상향 2상유동에서 고분자물질이 유동양식에 미치는 영향)

  • 김재근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.4
    • /
    • pp.505-514
    • /
    • 1998
  • Flow pattern of air-water two phase flow depends on the conditions of pressure void fraction and channel geometry. We classify the flow pattern by measuring the output signal of the conductivity probe. under the classified flow pattern we mount a visualization equipment on the test section and take pictures. We vary the concentration of pure solvent and polymer to measure local void fraction. We know that the maximum point position of local void fraction distribution move from the center of the pipe to the wall of the pipe as JSL increase when JSA is constant in two phase flow. But we find that the maximum point position of local void friction move from the wal of the pipe to the center of the pipe when polymer concentration increase.

  • PDF

The effect of melt flow index on polymer deformation in hot embossing process (고분자 분자량 변화에 따른 핫 엠보싱 공정 연구)

  • Yoon, Keun-Byoung;Jeong, Myung-Young
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1025-1029
    • /
    • 2003
  • We studied the cross-sectional profiles of deformed thermoplastics in hot embossing process and compared with melt flow index for various embossing conditions such as embossing temperature, embossing pressure and initial thickness of the thermoplastics. The fastest embossing times for complete penetration of the cavities were obtained at temperature greater than $60^{\circ}C$ above glass transition temperature (Tg). When the melt flow index of polymer is low, the penetration ratio does not become large even if the embossing pressure increases. The complete occupation of the cavities was easier obtained with high melt flow index polymer than low melt flow index polymer at the same process condition. We believe these results can be very useful for optimizing nanostructured hot embossing also known nanoimprinting process conditions.

  • PDF