• Title/Summary/Keyword: Poly-(hydroxyethyl methacrylate)

검색결과 54건 처리시간 0.031초

Poly(2-Hydroxyethyl Methacrylate) 수화겔 막에 대한 알카리 금속 염화물의 수송현상 (\Transport Phenomena of Alkali Metal Chlorides theough Poly(2-Hydroxyethyl Methacrylate) Hydrogel Membrane)

  • 성용길;이춘기;전무식
    • 대한의용생체공학회:의공학회지
    • /
    • 제8권2호
    • /
    • pp.123-134
    • /
    • 1987
  • The transport phenomena of alkali metal chlorides through poly(2 hydroxyethyl methacrylate) hydrogel membrane have been studied using electrodialysis. The hydrogel membranes were prepared by the polymerization of 2-hydroxvethyl methacrylate in the presence of 45%(V/V) H2O and ethyleneglycodimethacrylate. The initiator used in the polymerization was azobismethylisobutyrate (AMIB) prepared from azobisiobtyronitrile (AIBN) using Mortimer method. The permeability of alkali metal chlorides such LiCl, NaCl and KCI at 50 voltage was obtained. The permeability of NaCl was also observed at 30, 40, 50, and 60 voltages respectively. The concentration of solutes permeated through the membrane was measurer by flame photometry. The experimental results have been discussed with the comparison of apparent solute molecular size, the self-diffusion coefficient of solutes, the transport number of cations in aqueous solution. These indic aloes that poly(2 hydroxyethyl methacrylate) hydrogel membrane shows a specific selectivity for sodium ion.

  • PDF

가교결합한 Poly((vinylbenzyl)trimethylammonium chloride-2-hydroxyethyl methacrylate)/poly(vinyl alcohol) 음이온 교환막 제조 (Preparation of Anion Exchange Membranes of Cross-linked Poly((vinylbenzyl)trimethylammonium chloride-2-hydroxyethyl methacrylate)/Poly(vinyl alcohol))

  • 김미양;김광제;강호
    • 공업화학
    • /
    • 제21권6호
    • /
    • pp.621-626
    • /
    • 2010
  • 음이온 교환막은 전기투석뿐만 아니라 역전기투석에 의한 전기생산과 축전 탈이온에 의한 정수 분야에 이용될 수 있다. 본 연구에서는 폴리비닐알콜 수용액 상에서 (vinylbenzyl)trimethylammonium chloride와 2-hydroxyethyl methacrylate를 중합한 후 글루타르산과의 에스테르화 반응, 그리고 글루타르알데히드와 가교반응을 통해서 음이온 교환막을 제조하였다. 실험 변수에 따라 음이온 교환막을 제조하고 이온교환막의 전기화학적 물성을 조사하였다. 중합반응에서 음이온 교환성 단량체 비율에 따라 이온교환량과 저항 값이 변하였으며, 에스테르화 반응에서는 글루타르산의 함량의 증가에 따라 함수율과 전도도가 감소하였다. 형성된 필름과 알데히드의 가교반응 시간 변화는 함수율, 전기저항, 이동수 값들에 영향을 미쳤다. 끝으로 제조된 이온 교환막의 chronopotentiometry와 한계전류밀도도 측정하였다.

PHENYLSILANS와 2-HYDROXYETHYL METHACRYLATE의 열중합 (THERMAL POLYMERIZATION OF 2-HYDROXYETHYL METHACRYLATE WITH PHENYLSILANS)

  • 성아영
    • 한국안광학회지
    • /
    • 제5권2호
    • /
    • pp.87-90
    • /
    • 2000
  • Poly(HEMA)는 소프트 콘택트렌즈의 재료로써 널리 사용되어 왔다. $phSiH_3$, $phMeSiH_2$, $ph2SiH_2$와 같은 다양한 hydrosilane들과 hydroxyethyl methacrylate(HEMA)와의 열중합은 Phenylsilyl 말단기를 포함하는 poly(HEMA)를 생성시켰다. 열중합 반응 동안에는 Phenylsilane의 농도가 증가함에 따라 고분자의 분자량과 고분자 수득률이 감소됨을 보였으며 광중합 반응에서 보다 중합 수득률, 고분자의 분자량, TGA 잔여 수율 등이 더 높았다.

  • PDF

Template polymerization of multi-vinyl monomer with poly(2-hydroxyethyl methacrylate) backbone

  • Saito, Reiko;Yoko, Kazutaka;Iijima, Yuki
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.323-323
    • /
    • 2006
  • Multi-vinyl monomer, which contains many vinyl groups in a molecule, was prepared by esterification of hydroxyl groups of poly(2-hydroxyethyl methacrylate) with methacryloyl chloride. Then, copper-mediated atom transfer radical polymerization was carried out as a template polymerization. The propagation of polymerization was investigated by kinetic analysis.

  • PDF

단백질흡착을 막는 소프트콘택트렌즈에 관한 연구 (A Study on Protein Adsorption-resistant Soft Contact Lens)

  • 조종수;정영일
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권3호
    • /
    • pp.291-296
    • /
    • 1996
  • Poly(ethylene glycol)(PEG) macromers terminated with diacrylate Iyoups and interpenetrating poly- mer networks(IPN) composed of poly(hydroxyethyl methacrylate)(PHEMA) or poly(hydroxyethyl methacrylate-co-hydronypropyl methacrylate-co- N-vinyl pyrrolidone ) [ P( HEM A-co- HPM A-co- NVP) ] and PEG macromer were synthesized with the aim of obtaining protein adsorption resistant soft contact lens. Polymerization of PEC macromer resulted in the formation of cross-linked gels due to the multifunctionality of macromer. Crosslinked P(HEMA) or P(HEMA-co-HPMA-co-WVP) chains were interpenetrated into the cross-linked three-dimensional networks of PEG. It was found that albumin adsorption onto the contact lens prepared by P(HEMA-co-HPMA-co-NVP) /PEG IPW decreases with an increase of molecular weight of PEG. Also, it was found that albumin adsorption onto the both contact lens decreases with an increase of concentration of PEC macromer in the IPN preparation. There are also more adequate in the bioinertnen for the contact lens by P(HEMA)/PEG IPN or P (HEMA-co-HPMA-co-NVP)/PEG IPN than that by P(HEMA) or P(HEMA-co-HPMA-co-NVP)

  • PDF

반응성 공중합체들을 이용한 습도센서의 감습 특성 (Humidity Sensitive Properties of Humidity Sensor Using Reactive Copolymers)

  • 김진석;배장순;공명선
    • 한국재료학회지
    • /
    • 제11권2호
    • /
    • pp.126-131
    • /
    • 2001
  • 4 차 암모늄염을 형성할 수 있는 공중합체들 poly[(vinylbenzyl chloride)-co-(n-butyl acrylate)-co-(2-hydroxyethyl methacrylate)]와 poly[(4-vinylpyridine)-co-(n-butyl acrylate)-co-(2-hydroxyethyl methacrylate)]를 고분자막 습도센서의 감습재료로 사용하기 위하여 합성하였다. 습도센서는 30%RH, 60%RH 그리고 90%RH에서 평균 저항 값은 각각 8.6 M $\Omega$, 310 k$\Omega$ 그리고 12 k$\Omega$을 보여 주었다. 또한 히스테리시스는 $\pm$3%RH 안에서 나타났으며, 온도의존성 계수는 -0.37~-0.407RH/$^{\circ}C$이었다. 감습막의 조성에서 공중합체 중 n-BA와 HEMA의 도입은 저항을 증가시키는 요인이 되나 기판과의 접착성은 크게 향상되었다. 33%RH에서 85%RH로 또는 역으로 변화할 때의 응답속도는 54초이며 수중에 2시간 침적 후 저항의 변화는 +0.2%RH 이내에서 존재하였다.

  • PDF

Poly(2-Hydroxyethyl Methacrylate)막을 통한 아미노산의 확산 기구에 관한 연구 (The Study for Diffusion Mechanism of Amino Acids Through Poly(2-Hydroxyethyl Methacrylate) Membrane)

  • 김의락;정봉진;이명재;민경섭
    • 대한화학회지
    • /
    • 제37권1호
    • /
    • pp.10-21
    • /
    • 1993
  • 2-hydroxyethyl methacrylate(HEMA)을 중합한 P(HEMA)막을 통하여 10가지 아미노산들의 확산계수, 분배계수 및 투과도를 용액의 pH 변화하에서 조사 연구하였다. 아미노산의 투과도는 각 아미노산들의 분자형태, 분자크기 및 전하량에 따라 다른 값을 나타냄을 확인하였으며, 특히 용액의 pH에 따라 전하량이 변화하는 각 아미노산은 P(HEMA)막을 통하여 투과시킬 때 모든 아미노산이 중성영역용액에서 가장 많이 투과되고 이때 막은 미세공막으로 작용하며, 염기성영역용액에는 산성영역용액보다 더 많이 투과되고 막은 분배막으로 작용함을 알았다.

  • PDF

혈장내 염의 Poly(2-Hydroxyethyl Methacrylate) 격막 투과현상 (Transport of Some Solutes in Blood Plasma Through Poly(2-Hydroxyethyl Methacrylate) Hydrogel Membrane)

  • 지종기;전무식;이태규
    • 대한화학회지
    • /
    • 제22권5호
    • /
    • pp.304-310
    • /
    • 1978
  • 혈장내의 중요한 성분인 몇가지 염들이 poly(2-hydroxyethyl methacrylate) 격막을 통과하는 상대투과계수($U_{re}$), 분배계수($K_D$), 확산계수($D_m$)등을 측정하였다. 이 격막을 제조할 때 cross-linker로서 사용된 tetraethylene glycol dimethacrylate(TEGDMA)의 함량은 중량비로 2.8%였다. 이 염들의 확산계수는 그 분자량이 증가함에 따라서 지수함수적으로 감소하였으며, 그 분자의 원통반지름(a)에 대해서는 요소를 제외하고는 직선적으로 감소하였다. 이와 같은 사실을 sieve pore filow 모델로서 설명하였다. 여러 온도에서 요소의 $U_{re}$$D_m$은 글리신, ${\beta}$-알라닌, D-글루코오스, 사카로스 및 말레산과 같은 다른 염들의 값보다 더 컸다. 이와 같은 결과는 이 poly(HEMA) 격막이 혈투석 응용에 적합하다는 사실을 보여 주었다.

  • PDF

단백질흡착을 막는 소프트콘택트렌즈에 관한 연구 (Study on protein adsorption resistant soft contact lens)

  • 정영일;조종수;나재운;김성호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.223-225
    • /
    • 1996
  • Poly (ethylene glycol) (PEG)macromers terminated with acrylate groups and interpenetrating polymer networks(IPN) composed of poly(hydroxyethyl methacrylate)(PHEMA) or poly(hydroxyethyl methacrylate-co-hydropropyl methacrylate-co-N-vinyl pyrrolidone) [P(HEMA-co-HPMA-co-NVP)] and PEG macromer were synthesized with the aim of obtaining protein adsorption resisatnt soft contact lens. Polymerization of PEG macromer resulted in the formation of cross-linked gels due to the multifunctionality of macromer. Crosslinked P(HEMA) or P(HEMA-co-HPMA-co-NVP) chains were interpenetrated into the cross-linked three-dimensional networks of PEG. It was found that albumin adsorption onto the contact lens prepared by P(HWMA)/PEG IPN decreases with a decrease of molecular weight of PEG whereas its adsorption onto the contact lens prepared by P(HEMA-co-HPMA-co-NVP)/PEG IPN decreases with an increase of molecular weight of PEG. Also, it was found that albumin adsorption onto the both contact lens decreases with an increase of concentration of PEG macromer in the IPN preparation. There are also more adequate in the bioinertness and bioadhesion for the contact lens by P(HEMA)/PEG IPN or P(HEMA-co-HPMA-co-NVP)/PEG IPN than that by P(HEMA) or P(HEMA-co-HPMA-co-NVP).

  • PDF