• Title/Summary/Keyword: Poly vinyl chloride (PVC)

Search Result 117, Processing Time 0.023 seconds

Synthesis and Electrochemical Properties of Carbon Coated Mo6S8 using PVC (PVC를 원료로 탄소코팅한 Mo6S8의 합성 및 전기화학적 특성)

  • Si-Cheol Hyun;Byung-Won Cho;Byung-Ki Na
    • Korean Chemical Engineering Research
    • /
    • v.61 no.3
    • /
    • pp.348-355
    • /
    • 2023
  • Magnesium secondary batteries are attracting much attention due to their potential to replace conventionally used lithium ion batteries. Magnesium secondary battery cathode material Mo6S8 were synthesized by molten salt synthesis method and PVC as a carbon materials were added to improve electrochemical properties. Crystal structure, size and surface of the synthesized anode materials were measured through XRD and SEM. Charge-discharge profiles and rate capabilities were measured by battery test system. 2.81 wt% PVC coated sample showed the best rate capabilities of 85.8 mAh/g at 0.125 C-rate, 69.2 mAh/g at 0.5 C-rate, and 60.5 mAh/g at 1 C-rate.

Comparison of Analytical Methods for DEHP Migration from PVC Bags for Blood Storage and Infusion; By Gas Chromatography and UV-vis Spectrophotometry (혈액·수액용 PVC 백에서 용출된 DEHP의 검출 분석 방법 비교; 기체 크로마토그래프와 분광 광도계)

  • Kim, Jung Hwan;Kim, Seong Hun;Choi, Hyeong Ki;Lee, Chang Hyung
    • Analytical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.72-79
    • /
    • 2002
  • Di-(2-ethylhexyl)phthalate (DEHP) may be released from plasticized poly(vinyl chloride) (PVC) articles. In the cases of various methods for the quantitative analysis of migrating DEHP, there are much differences in migrating quantity according to the experimental methods. It is therefore important to make the comparison and analysis between these two results. A study of DEHP migration from blood and infusion bags has been carried out in different methods to evaluate the amount of DEHP migration using gas chromatograph and UV-vis spectrophotometry. Five PVC bags were cut into plane sheets in size of $40{\times}10{\times}0.4mm$, then were immersed in extraction solvent for an hour to release DEHP. It was determined by a gas chromatograph that $23.2{\sim}70.9{\mu}g/mL$ of DEHP was extracted. While extraction solvent was injected into PVC bags which were then placed for an hour to leach DEHP out. It was checked by a UV-vis spectrophotometer that the concentration of DEHP in extraction solvent was $24.8{\sim}41.3{\mu}g/mL$. Two results show different values according to the extraction conditions and experimental methods and the gas chromatographic results were converted into UV-vis spectroscopic results on condition that DEHP would be extracted equally per unit time and unit contact area. It was concluded that DEHP migrating amounts are approximately equal in two analytical methods.

Study on manufacturing mechanism of functional carbon membrane (기능성 카본막의 제조 Mechanism에 관한 연구)

  • Bae, Sang-Dae
    • The Journal of the Convergence on Culture Technology
    • /
    • v.4 no.2
    • /
    • pp.211-216
    • /
    • 2018
  • Separation technology combining adsorption and membrane is expected to be applied in many fields such as water treatment. In this fusion technique, a functional carbon membrane having a carbon whisker grown on the surface of the membrane was developed to inhibit membrane fouling, which is a problem in the membrane separation process. In this study, to elucidate the mechanism of manufacturing the functional carbon membrane, the membrane was pretreated with the polymer latex of each mixing ratio and the membrane was formed by the CVD (Chemical Vapor Deposition) method. The membrane was analyzed by scanning electron microscope (SEM), CHN analyzer (Elemental Analyzer), and X-ray diffraction (XRD). As a result, the diameter and density of carbon whiskers were higher in case of polyvinyl di-chloride (PVdC): polyvinyl chloride (PVC) = 4.5: 55. It seems possible to control the diameter and density of the carbon whiskers according to the hydrogen content of the polymer latex.

Monitoring of Butyltin Compounds in PVC Food Packaging - Determination of Butyltin Compounds in PVC Wrap and Gasket for Food Packaging by GC/MS (식품용 염화비닐수지제 기구 및 용기.포장 중 부틸주석화합물의 모니터링 - GC/MS를 이용한 염화비닐수지제 식품용 랩 및 가스킷 재질 중 부틸주석화합물 잔류량 분석)

  • Sung, Jun-Hyun;Yoon, Hae-Jung;Choi, Hyun-Cheol;Jeon, Dae-Hoon;Eom, Mi-Ok;Kim, Hyung-Il;Park, Na-Young;Lee, Eun-Joon;Lee, Young-Ja
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.6
    • /
    • pp.715-720
    • /
    • 2007
  • The levels of butyltin compounds in poly(vinyl chloride) (PVC) food packaging using gas chromatography/mass spectrometry (GC/MS) were monitored. The analytical method, involving the ethylation with sodium tetraethylborate, was found to be selective and sensitive for mono-n-butyltin (MBT), di-n-butyltin (DBT), and tri-n-butyltin (TBT), validated by a $0.005\;{\mu}g/mL$ limit of detection (LOD), an $R^2>0.999$ for linearity, and >90% of recovery, respectively. Finally, none of the commercial food wraps and gaskets showed detectable levels of butyltin compounds.

The Analysis of Thermal Conductivity and Basic Quality Performances of Decoration Wood-based Flooring Board Laminated with PVC Surface Decoration Materials (PVC 표면치장재를 적층한 치장목질마루판의 열특성 및 기초 품질성능 분석)

  • Park, Cheul-Woo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.1
    • /
    • pp.53-60
    • /
    • 2018
  • For test on flooring board laminated with PVC decoration materials in order to replace the current surface materials such as HPL in decoration wood-based flooring board. the Results of comparison and analysis are as follows: For thermal conductivity, flooring board decorated with PVC did not show huge differences when temperature was rising and lowering compared to the flooring materials laminated with the existing HPL surface materials. It seems the most meaningful results for using it as indoor flooring materials. That is, in Korea where there is the culture focusing on ondol heating, use amount of heat energy and efficiency of flooring materials are very important and sensitive issues, involving immediately with household economy of final consumers, and it might be a criteria to judge basic performances required as flooring materials. As a result of the analysis on mandatory durability test items such as abrasion resistance, absorption width expansion rate, impact resistance, surface hardness, and impact absorption for flooring materials, compared to flooring board laminated with general HPL surface decoration materials, decoration wood-based flooring board laminated with PVC surface decoration materials which is higher abrasion resistance with smaller transformation and has better durability and impact absorption of the surface, is available for actual application as indoor flooring board, and for replacing surface decoration materials impregnated with heat-hardened resion such as HPL.

Lithium Ion Selective Electrode Based on a Synthetic Neutural Carrier (중성운반체를 이용한 리튬이온 선택 전극)

  • Kim, Jae Sang
    • Analytical Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.33-39
    • /
    • 1992
  • THF-based crown-4 of 16-membered rings having tetrahydrofuran unit was synthesized by an acid-catalyzed condensation of furan and acetone followed by hydrogenation in an effort to obtain highly elective ionophores for lithium ions. The new ionophore was compared with previously reported ionophores under similar measurement conditions with the same plasticizer, tris(2-ethylhexyl) phosphate in poly(vinyl chloride)(PVC) membrane electrodes. Separate solution method was used to determine relative selectivity coefficients for the electrode. The selectivity coefficients($K_{LiM}^{POT}$) of lithium over ammonium, alkali and alkaline earth metal ions go from about $2.4{\times}10^{-1}$ to $2.3{\times}10^{-4}$ to working range and pH dependence have also been studied.

  • PDF

Degradation Properties in the QCM Gas Sensors Coated with the PEG Materials (PEG 물질을 도포한 QCM 가스센서의 열화특성)

  • Jang, Kyung-Uk;Kim, Myung-Ho;Lee, Won-Jae;Kim, Sang-Keol;Jung, Dong-Hoe;Lee, Joon-Ung;Lee, Ho-Sik;Kim, Tae-Wan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.218-222
    • /
    • 2002
  • In the recognition of the gases using the quartz crystal microbalance (QCM) coated with the PEG film materials, it is important to obtain the recognition ability of gases, and the stability of PEG film coated above the QCM. Especially, the thickness of PEG film coated above the QCM is decreased according with the using circumstance and time of QCM gas sensor. Therefore, the sensing characteristics of PEG film is changed with these. In this paper, we coated the PEG materials varing with the blended amount of PVC(Poly Vinyl Chloride) and chloroform above QCM to obtain the sensitive and the stability of PEG film. We measured the degradation characteristics of QCM gas sensor in the ethyle acetate 50[%] concentration to show the properties of stability.

  • PDF

Cover Requirements for Corrugated HDPE and PVC Pipes Used for Cross-drains in Highway Construction (고속도로 하부 횡단 배수시설로 사용되는 파형 플래스틱 관의 덮개 요건)

  • Kang, Junsuk;Davidson, James S.;Lim, Jeong-Hyeon;Kang, Young Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.4 no.1
    • /
    • pp.15-24
    • /
    • 2013
  • This project investigated the use of two types of thermoplastic pipes, High-Density Polyethylene (HDPE) and Poly-vinyl Chloride (PVC), as cross-drains under highways. Pipes ranging from 0.3 m (12 in.) to 1.5 m (60 in.) in diameter were evaluated under deep fills, minimum cover, and construction loads. In addition to a comprehensive literature review, an analytical study into the allowable fill heights for thermoplastic pipes and a field study to observe the installation and performance of the pipe in service conditions were conducted. Based on the study findings, recommendations regarding how and when thermoplastic pipe should be installed are provided.

Manganese(II) Ion-Selective Membrane Electrode Based on N-(2-picolinamido ethyl)-Picolinamide as Neutral Carrier

  • Aghaie, M.;Giahi, M.;Zawari, M.
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.10
    • /
    • pp.2980-2984
    • /
    • 2010
  • A new poly (vinyl chloride) (PVC) membrane electrode that is highly selective to $Mn^{+2}$ ions was prepared using N,N'-bis(2'-pyridinecarboxamide)-1,2-ethane ($bpenH_2$) as a suitable neutral carrier. This concentration range ($1.0{\times}10^{-5}$ to $1.0{\times}10^{-1}\;M$) with Nernstian slope of $29.3{\pm}0.5\;mV$ per decade. The detection limit and the response time of electrode were $8.0{\times}10^{-6}\;M$ and (${\leq}15\;s$) respectively. The membrane can be used for more than two months without observing any divergence. The electrodes exhibited excellent selectivity for $Mn^{+2}$ ion over other mono-, di- and trivalent cations. Selectivity coefficients were determined by the matched potential method (MPM). The electrode can be used in the pH range from 4.0 - 9.0. The isothermal coefficient of this electrode amounted to 0.00023 V/$^{\circ}C$. The stability constant (log $K_s$) of the $Mn^{+2}$ - $bpenH_2$ complex was determined at $25^{\circ}C$ by potentiometric titration in mixed aqueous solution. The proposed electrode was applied to the determination of $Mn^{+2}$ ions in real samples.

Development of a New Copper(II) Ion-selective Poly(vinyl chloride) Membrane Electrode Based on 2-Mercaptobenzoxazole

  • Akhond, Morteza;Ghaedi, Mehrorang;Tashkhourian, Javad
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.6
    • /
    • pp.882-886
    • /
    • 2005
  • Copper(II) ion-selective PVC membrane electrode based on 2-mercaptobenzoxazole as a new ionophore and o-nitrophenyl octyl ether (o-NPOE) as plasticizer is proposed. This electrode revealed good selectivity for $Cu^{2+}$ over a wide variety of other metal ions. Effects of experimental parameters such as membrane composition, nature and amount of plasticizer, and concentration of internal solution on the potential response of $Cu^{2+}$ sensor were investigated. The electrode exhibits good response for $Cu^{2+}$ in a wide linear range of 5.0 ${\times}$ 10−.6-1.6 ${\times}$ $10^{-2}$ mol/L with a slope of 29.2 ${\pm}$ 2.0 mV/decade. The response time of the sensor is less than 10 s, and the detection limit is 2.0 ${\times}$ $10^{-6}$ mol/L. The electrode response was stable in pH range of 4-6. The lifetime of the electrode was about 2 months. The electrode revealed comparatively good selectivities with respect to many alkali, alkaline earth, and transition metal ions.