Effects of Air Pollution on Physiological characteristics of Styrax japonica in Yeolchon Industrial Complex (여천공단주변 대기오염이 때죽나무의 생장 특성에 미치는 영향)

  • 김동근
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.2
    • /
    • pp.121-128
    • /
    • 2000
  • To identify the effects of air pollution on several physiological characteristics of Styrax japonica in Yeochon industrial comples soil properties photosynthetic capacity and chorophyll contents were investigated. All of these measurements were taken on Styrax japonica stand at 1. 3 and 7km from an industrial complex which is an air pollution source. In addition a Styrax japonica stand in Sang-ju city was selected as a control Each physiological measurement was in leaves of east-, west- south- and north-facing branches. The results obtained were as follows: 1) Al contents of soil in Yeochon industrial complex were higher than those of Sang-ju city a non-polluted area. higheral contents contributed to decrease in soil pH. 2) Chlorophyll contents of leaves at 1km from the industrial complex closest from the air pollution source were lower than those of 3 and 7km/ 3) Photosynthetic capacity of Styrax japonica at 1km from the air pollution source was lower than those at 3 and 7km.

  • PDF

A Study on Concentration of Volatile Organic Compounds in Newly-Apartment House by Measurement (실측을 통한 신축공동주택의 주요 VOCs 물질 농도에 관한 연구)

  • Kim, Chang-Nam;Kim, Young-Kyoung;Lee, Sung-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1220-1224
    • /
    • 2008
  • Because of the high airtightness and insulation of the building, indoor environment has been largely polluted resulted from insufficient ventilation and occurrence of new air pollutant. These factors have made worse indoor air quality and caused symptoms of the SHS(Sick House Syndrome), MCS(Multi Chemical Sensitivity). The purpose of this study is to present the fundamental strategies for improving the Indoor Air Quality(IAQ) in newly-constructed apartment buildings. To investigate the concentration of indoor air pollutants such as Formaldehyde and VOCs, the field measurement were conducted.

  • PDF

Physical Properties of Magnesium Oxide-Based Adsorption Matrix using Diatomite (산화마그네슘 기반 규조토를 활용한 흡착형 경화체의 물리적 특성)

  • Lee, Won-Gyu;Kyoung, In-Soo;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.184-185
    • /
    • 2019
  • Korea has defined fine dust as a social disaster as the problem of fine dust and air pollution becomes serious. Fine dust is classified as class one carcinogens because it is harmful to human body. When fine dusts enter the human body, they cause bronchial and skin diseases such as respiratory allergies, irritable pneumonia, asthma and atopy. As the air pollution becomes serious, the government is demanding measures to reduce fine dust. The polluted air in the outdoor is introduced into the room, thereby increasing the pollution degree of the indoor air quality. In this study, an adsorption type matrix for the improvement of indoor air quality was produced. Magnesium oxide and magnesium chloride were used as binders and diatomaceous earth was used as a adsorption material.

  • PDF

A Study on Recognition and Attitude of Residents in Seoul City about Air Environment (서울시민의 대기 환경에 관한 인식 및 태도)

  • 이정주;김신도;이경용
    • Journal of Environmental Health Sciences
    • /
    • v.21 no.4
    • /
    • pp.63-74
    • /
    • 1995
  • The objective of this study were to identify the state of re. cognition and attitude of residents in Seoul city about air environment and to identify factors affecting attitude toward air environment. Study object was residents in Seoul city sampled by multistage random proportional sampling. Sample size was 0.0067%(500 persons) of total residents in Seoul city. The results were divided into two parts: (1) descriptive results of recognition and attitude toward air environment, (2) results of factor analysis to classify categories of attitudes toward air environment and regression analysis to identify factors affecting attitude toward air environment. Most of resident in Seoul city recognized that air environment in Seoul city was highly polluted and was not satisfactory. Experience of damage of air pollution was reported in about 70% of residents in Seoul city. More than 60% of residents in Seoul city had concern about air environment. Attitude toward air environment were classified into four categories using factor analysis: Necessity of intervention of local government for air environment conservation, Participation of residents and enterprises for air environment conservation, Optimistic attitude about air pollution, Preference of economy. Factors affecting the above attitudes were knowledge about air pollution, knowledge about policies and institutions related air environment conservation, concern about air environment, educational level, subjective assessment of air environment, sex, marital status. In conclusion this study suggested providing information of air environment in Seoul city to the residents and to educating residents for making positive attitude about air environment conservation.

  • PDF

The Analysis of Ventilation of Road Tunnel in Fire (도로터널 화재시의 환기분석)

  • Kom, Sung-Joon;Ryu, Jin-Woong
    • Journal of Industrial Technology
    • /
    • v.23 no.A
    • /
    • pp.9-13
    • /
    • 2003
  • Numerical experiments are done by a commercial code, PHOENICS to evaluate the backlayer phenomenon of smoke in case of the road tunnel fire. The independent and dependent variables are ventilation air velocity and the length of backlayer of smoke respectively. Hybrid scheme and ${\kappa}-{\varepsilon}$ turbulence model are adopted in the simulation process and mass residual is used as a convergence criterion. The experimental results say that the length of backlayer is reduced with the increase of ventilating air velocity and that there is a critical air velocity which prevents from the onset of backlayering phenomena. One finds that there is a fresh air region near the bottom of tunnel which could make the passenger escape safely from the polluted region by smoke. These phenomena come from the vertical stratification of the smoke air mixture in the tunnel.

  • PDF

Relationship between Thermal Low and Long-Range Transport of Air Pollutants (대기오염물질의 장거리 수송과 열적저기압의 관계)

  • 이화운;김유근;김해동;정우식;현명숙
    • Journal of Environmental Science International
    • /
    • v.10 no.2
    • /
    • pp.143-151
    • /
    • 2001
  • The atmospheric conditions and the transport mechanism of long-range transport of air pollutants from coastal area to inland area were investigated using regular meteorological data and air pollution data obtatined from the southeastern area of Korea. Daytime temperature over the inland area(Taegu) was higher than that over the coastal area(Pusan) and the temperature difference of about 5~6$^{\circ}C$ when the thermal low most fully developed and the sea level pressure over Taegu was lower than that over Pusan by about 4~5hPa at that time. Therefore this low pressure appeared to the thermally induced low. Air mass polluted from the coastal area during the morning period was transported inland area, at first by the sea breeze and by the large scale wind system toward the thermal low generated in the mountainous inland region. This was explained by the fact that the concentration of air pollutants over Taegu increased throughtout the late afternoon.

  • PDF

A study on development of basic natural system for polluted streams using wasted concrete and Oenanthe javanica (미나리와 폐콘크리트를 이용한 하천정화공법의 기초 연구)

  • Kim, Jwa-Kwan;Yoon, Sung-Yoon
    • Journal of Wetlands Research
    • /
    • v.2 no.1
    • /
    • pp.59-67
    • /
    • 2000
  • The aim of this study is to identify the role of this natural treatment system, which consists of Oenanthe javanica and wasted concrete as bio-media. Therefore, it was designed to experiment water quality, BOD, SS, T-N, T-P to recognize the efficiency of treatment system with one biofilter tank using wasted concrete and vegetation bed using Oenanthe javanica. It was also designed to compare two different biofilter reactors, which are air lift and upflow methods. In the result, it was demonstrated that upflow method is more efficient system to control water quality of polluted streams. The vegetation bed using Oenanthe javanica has the treatment efficiency of 41 % (BOD), 52 % (COD), 60% (SS), 36 % (T-P), 70 % ($NH_4-N$). It was therefore proved that removal rates of nutrients are not so good except $NH_4-N$ concentration with nitrification.

  • PDF

A Regional Source-Receptor Analysis for Air Pollutants in Seoul Metropolitan Area (수도권지역에서의 권역간 대기오염물질 상호영향 연구)

  • Lee, Yong-Mi;Hong, Sung-Chul;Yoo, Chul;Kim, Jeong-Soo;Hong, Ji-Hyung;Park, Il-Su
    • Journal of Environmental Science International
    • /
    • v.19 no.5
    • /
    • pp.591-605
    • /
    • 2010
  • This study were to simulate major criteria air pollutants and estimate regional source-receptor relationship using air quality prediction model (TAPM ; The Air Pollution Model) in the Seoul Metropolitan area. Source-receptor relationship was estimated by contribution of each region to other regions and region itself through dividing the Seoul metropolitan area into five regions. According to administrative boundary, region I and region II were Seoul and Incheon in order. Gyeonggi was divided into three regions by directions like southern(region III), northern(IV) and eastern(V) area. Gridded emissions ($1km{\times}1km$) by Clean Air Pollicy Support System (CAPSS) of National Institute of Environmental Research (NIER) was prepared for TAPM simulation. The operational weather prediction system, Regional Data Assimilation and Prediction System (RDAPS) operated by the Korean Meteorology Administration (KMA) was used for the regional weather forecasting with 30km grid resolution. Modeling period was 5 continuous days for each season with non-precipitation. The results showed that region I was the most air-polluted area and it was 3~4 times more polluted region than other regions for $NO_2$, $SO_2$ and PM10. Contributions of $SO_2$ $NO_2$ and PM10 to region I, II and III were more than 50 percent for their own sources. However region IV and V were mostly affected by sources of region I, II and III. When emissions of all regions were assumed to reduce 10 and 20 percent separately, air pollution of each region was reduced linearly and the contributions of reduction scenario were similar to those of base case. As input emissions were reduced according to different ratio - region I 40 percent, region II and III 20 percent, region IV and V 10 percent, air pollutions of region I and III were decreased remarkably. The contributions to region I, II, III were also reduced for their own sources. However, region I, II and III affected more regions IV and V. Shortly, graded reduction of emission could be more effective to control air pollution in emission imbalanced area.

Evaluation of Pollutants Emissions according to the Selling Store in Department Store (백화점 내 업종별 판매매장에 따른 오염물질 배출현황 평가)

  • Wang, HyeongSeok;Hwang, JunSeok;Chang, SeongJin;Kim, Sumin
    • Journal of the Korea Furniture Society
    • /
    • v.26 no.1
    • /
    • pp.71-76
    • /
    • 2015
  • It is important thing that air quality affects human health. And It is more important thing that Indoor Air Quality more affects human health than Outdoor Air Quality. The cause of that is indoor air pollutants are more absorbed than outdoor air pollutants. By the way, in case of Multi-use facility for example office, department store, school etc., it has a feature that there are more people than any other buildings. therethrough, effects of Indoor Air Quality of Multi-use facility affect more people's health than Indoor Air Quality of any other buildings. However, in multi-use facility, specifically retail store, chemical treated materials are used for interior finishing, showcase finishing and product finishing because esthetic element is more added for detention of customer. Consequently, in place where demands brisk sales, possibility that indoor air is polluted by VOCs is high. This study considered retail store's Indoor Air Quality. as result of experiment, figure of department store's air pollution exceed about 5~20 times in guideline of multi-use facility's Indoor Air Quality in any kind of shop of department store (guideline : $500{\mu}g/m^3$).

Numerical Analysis of Wintertime Air Pollution in East Asia Region Using Long-Range Transport Model

  • Jang, Eun-Suk
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.4 no.2
    • /
    • pp.103-110
    • /
    • 2000
  • In order to understand the wintertime intermittent characteristics of the trans-boundary air pollutant transport observed in East Asia, a numerical simulation of the long-range transport of pollutants was applied using an atmospheric transport model(STEM-II). The numerical simulation was carried out for the entire month of January 1997 and specific atmospheric aerosol (including sulfate, nitrate, and other ion compounds0 observation data were compared from four observation sites(Cheju Island, Kanghwa Island, Dazaifu, and Fukue Island). The observation data revealed that concentration peaks were intermittently observed at 3 to 4-day intervals plus the four observation sites exhibited a very similar spatial variation. The horizontal and spatial scale of the heavily polluted air masses was analyzed based on numerical results. The mechanism of the intermittent transport of air pollutants was clearly explained by a comparison of the observed data with the numerical output. It was found that the wind pattern variations associated with the synoptic scale pressure system changes play an extremely important role in the transport of pollutants in this region.