• 제목/요약/키워드: Pollutants load

검색결과 314건 처리시간 0.03초

비모수검정을 이용한 논침투수 수질의 평가 (Evaluation of Percolated Water Quality of Paddy Fields Using Nonparametric Test)

  • 오승영;김진수;오광영
    • 한국농공학회논문집
    • /
    • 제47권2호
    • /
    • pp.99-110
    • /
    • 2005
  • Characteristics of concentrations of total nitrogen (TN), total phosphorus (TP), and chemical oxygen demand (COD) pollutant in percolated water at four paddy field sites (Soro, Odong, Munui, and Boeun) were investigated by a nonparametric test. Percolation rate measurement and percolated water sampling were taken during irrigation periods at $5{\sim}10$ day intervals. The normality of percolation rate and pollutant concentrations were examined using histogram, boxplot, and the Kolmogorov-Smirnov (K-S) test. Pollutant concentrations in percolated water showed positively skewed distribution. The median concentrations of pollutant were 1.91 mg/L for TN, 0.021 mg/L for TP, and 6.6 mg/L for COD, which were lower than its arithmetic mean concentrations by $35\%$ for TN, $36\%$ for TP, and $13\%$ for COD. The median concentrations of TN and TP differed significantly among sample sites according to the Kruskal-Wallis test. However, median concentrations were not significantly different among month except for TN and TP of Soro and COD of Odong. The percolation load of pollutants during irrigation periods in the study area were estimated at $3.12{\sim}7.75\;kg/ha$ for TN, $0.033{\sim}0.155\;kg/ha$ for TP, and 10.7 kg/ha for COD, which were much lower than respective values reported in Japan.

사례분석을 통한 친환경 건축물 인증제도 개선방향 연구 (A Study of Case Analysis on Green Building Certification Criteria for Advanced Methods)

  • 모지선;김철;임태섭;강윤도;김병선
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.178-183
    • /
    • 2008
  • Recently, sick house syndrome caused by pollutants and contamination of buildings crops out in residential environment of buildings. According to price increase of global oil, comfort of occupants in indoor air quality is required with reduction of energy consumption and environmental load. So, building performance certification criteria come into effect for improvement of building energy efficiency and performance in environment at home and abroad. GBCC(Green Building Certification Criteria) of domestic country as a Criteria is managed Korea Green Building Council(KGBC) for green building. Thus, purpose of this study is to design a direction of Green Building Certification Criteria for improvement through analysis of GBCC application elements and selected building.

  • PDF

대청호 유역의 수질평가를 위한 종합수질지수의 적용 (Application of Korean Water Quality Index for the Assessment of River Water Quality in the Basin of Daecheong Lake)

  • 정세웅;박재호
    • 한국물환경학회지
    • /
    • 제21권5호
    • /
    • pp.470-476
    • /
    • 2005
  • The Korean Water Quality Index (K-WQI) was applied to the rivers located in the watershed of Daecheong Lake to assess the status of river water quality, and propose potential target constituents for better water quality management in the watershed. The estimated K-WQI value for each river was varied from 70 to 90, and Youngdongcheon showed the worst score while Mujunamdeachen showed the best score. The total nitrogen (TN) and total coliform bacteria were identified as the most significant constituents that degrade the K-WQI values in the rivers. The correlation coefficients (r) were determined between K-WQI and the delivered specific load ($kg/km^2/yr$) of BOD, TN, and TP to justify potential target constituents that have a great influence on the improvement of K-WQI values. The results showed that TN (r=-0.86) and TP (r=-0.85) have a strong negative relationships with K-WQI, but BOD have almost no effect. This implies that BOD, the surrogate parameter for organic pollutants, is no more a feasible water quality variable for the water quality management in the study site.

주차장 및 교량 강우유출수의 중금속 오염물질 특성과 동적 EMCs (Characteristics of Metal Pollutants and Dynamic EMCs in a Parking Lot and a Bridge during Storms)

  • 김이형;이선하
    • 한국물환경학회지
    • /
    • 제21권4호
    • /
    • pp.385-392
    • /
    • 2005
  • The control of nonpoint source pollution is essentially needed to successfully perform the Total Maximum Daily Load program. Of the various land uses in the nonpoint source, the paved areas such as a parking lot and a bridge are stormwater intensive land uses because of high imperviousness and high pollutant mass emissions. This research was performed to understand the magnitude and nature of the stormwater emissions with the purposes of quantifying stormwater pollutant concentrations and mass emission rates from a parking lot and a bridge. Two monitoring sites in Kongju city were equipped with an automatic rainfall gages and an automatic flow meter for accumulating the data such as rainfall, water quality and runoff flow rates. This paper will summarize the metal concentration changes during the storm duration and metal EMCs to characterize the concentration profiles in a parking lot and a bridge. Also a new concept, dynamic EMC, will be proposed to find the relationship between EMC and first flush effect. It can be used to determine the economical treatment criteria in best management practices.

영산강 유역 도시지역의 비점오염원 배출특성에 관한 연구 (Study on the Discharge Characteristics of Non-point Pollutant Source in the Urban Area of the Youngsan-River Basin)

  • 진영훈;박성천
    • 한국물환경학회지
    • /
    • 제22권4호
    • /
    • pp.605-613
    • /
    • 2006
  • Discharge characteristics of non-point source pollutant and load amount of the discharge in the urban area were investigated in the Pungyeongjeong-stream basin and the Yongbong-stream basin in this present study. The land use of the studied basins were divided into paddy field, industrial complex area, combined sewage system, separate sewer system and point sources discharge. The descriptive statistics on the event mean concentrations (EMCs) of non-point pollutants by the the land use showed in the range of 4.43-32.28 mg/L for BOD and 8.27~56.17 mg/L for COD. The highest concentration was shown from the combined sewage system. The EMC of SS at the paddy field in the Pungyeongjeong-stream basin showed the highest range with the values ~ from 35.76 to 358.86 mg/L, which might have been influenced by a levee construction in the adjacent of the area. The relatively high concentration values of 4.43~32.28 mg/L and 1.617.13 mg/L emerged from TN and TP,respectively, at the discharge points of the both stream basins.

생물검정에 의한 남조류 Microcystis가 수질에 미치는 영향 (The Impact on Water Quality from Blue-Green Algae Microcystis Natural Phytoplankton by Algal Assay)

  • 신재기;조경제
    • 한국환경과학회지
    • /
    • 제9권3호
    • /
    • pp.267-273
    • /
    • 2000
  • In order to understand the impact for decomposition of blue-green algae Microcystis on water quality, the algae were cultivated with collection of natural population during approximately one month, when water-bloom of Microcystis dominated at August 31, 1999 in the lower part of the Okchon Stream. The enrichment of inorganic NㆍP nutrients didn't in algal assay and the effect of Microcystis on water duality was assessed from the variation of nutrients by algal senescence. Microcystis population seemed to play a temporary role of sink for nutrients in the water body. Initial algal density of Microcystis was 2.3×10/sup 6/ cells/㎖. When Microcystis population died out under light condition, algal NㆍP nutrients between 9∼12 days affected to increase of biomass after reuse by other algal growth as soon as release to the ambient water. However, cellular nutrients under dark condition were almost moved into the water during algal cultivation. NH₄, NO₃ and SRP concentration were highly increased with 160, 17 and 79 folds, respectively relative to the early. As a result, the senescence of Microcystis population seemed to be an important biological factor in which cause more eutrophy and increase of explosive algal development by a lot of nutrients transfer to water body. There are significantly observed an effort of reduce for production of inner organic matters such a phytoplankton as well as load pollutants from watershed in side of the water quality management of reservoir.

  • PDF

국내 4개 중유발전소 실증실험을 통한 발전연료 대체용 바이오중유의 연소특성 연구 (The Four Power Plants Field Demonstration Research on Combustion Characteristic of the Bio Oil for Fuel Switching)

  • 백세현;김현희;박호영;김영주;김태형;고성호
    • 한국연소학회지
    • /
    • 제20권1호
    • /
    • pp.15-23
    • /
    • 2015
  • This paper presents the results of field demonstration for fuel switching to bio-fuel oil in 4 commercial heavy oil fired power plants. The 100% fuel switching field demonstration was successfully carried out in two tangential-firing boilers at a capacity of 75 and 100 MWe respectively without major equipment retrofit, and also 25% bio-fuel oil blending for two opposite firing boilers at a capacity of 350 and 400 MWe respectively. Despite the low density and heating value, the bio fuel was successfully replaced heavy fuel oil at the full load by only adjusting operational parameters. Incase of bio fuel oil combustion, heat absorption of radiative heat transfer section was reduced while convection section has opposite trend. In pollutants emission, a major reductionin SOx as well as 10-20% reduction in NOx were achieved by the fuels witching. On the other hand, boiler efficiency was slightly underestimated.

합리적인 유역단위 오염부하량 산정방법 연구 (Calculation of Pollutant Load for Prediction of Pollutant Loads to Watershed)

  • 장재호;윤춘경;정광욱;김형철
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2005년도 학술발표논문집
    • /
    • pp.534-539
    • /
    • 2005
  • The purpose of this study is the introduction of pollutant loads's estimation into Saemangeum watershed area with M.E.'s guidebook for TMDL and GIS tool. To estimate reliable pollutants loads, it is necessary to think about characteristic of removal, discharge and runoff as time series. In this study, it was calculated for generation loads which be came from pollutant source, discharge loads which be reduced in the treatment facilities and delivery loads which be considered the self purification parameter and delivery distance. To assess the delivery distance handily, it was particularly estimated using Arc-GIS. It was met with good results that delivery loads of BOD, T-N and T-P was reflected to seasonal precipitation. Lastly to verify the estimated pollutant loads, HSPF developed by USEPA was applied to it. It was showed a relativity of observed to simulated data for flow, Temperature, DO, BOD, $NO_3^--N$ TN and TP. Consequantly, this delivery loads can make full use of model input data for prediction of pollutant loads.

  • PDF

열회수형 환기장치의 운전조건에 따른 경제성 평가에 관한 연구 (A Cost Analysis of the Heat Recovery Ventilator under Various Condition)

  • 강태욱;고재윤
    • 한국태양에너지학회 논문집
    • /
    • 제26권1호
    • /
    • pp.21-28
    • /
    • 2006
  • Changes in building construction methods and repairing of older buildings have reduced infiltration rate. Synthetic materials, release airborne particles and uneven healthy odor are increased. For preventing pollutants introduce fresh outdoor air into the building, simply letting fresh outdoor air into building, however, Is not a cost-effective way to ventilation. When additional ventilation is added to an existing HVAC system, the heating and cooling equipment, often cannot handle the increased load. A HRV provides a way to minimize in energy costs while introducing fresh air to a building. In this study, the economical research of HRV, made of three types of materials, are conducted. Heat recovering characteristics are studied at seasonal outdoor air conditions based on the outdoor air property condition at, Seoul in 2002. As a results, the average sensible effectiveness is 0.75 in the sensible heat exchanger and average total effectiveness is 0.65 in the total heat exchanger. The pay back period of the sensible heat exchangers are $3.2{\sim}3.5$ year and it of total heat exchanger is 2.2 years.

도시철도 지하역사 공기조화기의 미세먼지 저감성능 개선을 위한 사전연구 (Pre-study for the improvement of air filtration performance in the air handling unit of subway station)

  • 강중구;신창헌;배성준;권순박;김세영;한석윤
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.541-545
    • /
    • 2008
  • Particulate matter (PM) is one of the major indoor air pollutants especially in the subway station in Korea. In order to remove PM in the subway station, several kinds of PM removal system such as roll-filter, auto-washable air filter, demister, and electrostatic precipitator re used in the air handling unit (AHU) of subway station. However, those systems are faced to operation and maintenance problems since the filter-regeneration unit consisting of electrical or water jet parts is malfunctioned due to the high load of particulates and the filter material needs periodic replacement. In this study, we surveyed the particle removal systems in order to develop the new system of particle removing can be adopted in the current AHU of subway station.

  • PDF