• Title/Summary/Keyword: Pollutants

Search Result 4,214, Processing Time 0.031 seconds

Best Buffer Width of Riparian Buffer Zone using a Pilot with Different Plant Species for Reduction of Non-point Pollutant Loading (비점오염저감을 위한 수변완충지대의 적정 설계)

  • Kim, Sung-Won;Choi, I-Song;Oh, Jong-Min
    • Journal of Environmental Impact Assessment
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • Non-point pollution is caused by many diffusive sources, unlike a point pollution derived from industrial wastewater treatment plants or sewage treatment plants. Runoff of non-point pollutants is originated from rainfall or thawing in short period of time moving over and through the a ground surface. They cause ill effect on the quality of neighboring aquatic environment. To prevent effectively the wash off from non-point pollutant, it should be immediately reduced at the source or be treated after gathering of runoff water. This study has been carried out for the best width of riparian buffer zone. So we implemented the experiment in terms of its depth, width and kind of vegetations and calculated the reduction of pollutants loading. The experimental zone encompasses the watershed of Namhan River (Kyunggido Yangpyunggun Byungsanri). The region was divided into 5 land cover sectors : grass, reed, pussy willow, mixed(grass+pussy willow) and natural zone to compare effectiveness of vegetation. Water samples from four points have been collected in different depths. And the pollutant removal efficiency by sectors with different plant species was yielded through influent with one of each sample. And we obtained the correlation between the width of riparian buffer zone and the removal efficiency of pollutants. Using correlation result, the width of riparian buffer zones which needs to improve the water quality of river could be derived.

Studies on the Accelerated Aging Characteristics of Paper Records by Gaseous Air Pollutants (가스상 대기오염물질에 의한 종이 기록물의 가속열화 특성 연구)

  • Jeong, So-Yoon;Jeon, Soo-Yeon;Baek, So-Ra;Jeong, Hyun-Seok;Lee, Jin-Hee;Kim, Hyoung-Jin
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.47 no.4
    • /
    • pp.151-159
    • /
    • 2015
  • Paper records were generally degraded by some factors from atmospheric environments, like temperature, relative humidity or air pollutants. In this study, the degradation behavior of paper records by single or mixed gases of $NO_2$, $SO_2$, HCHO and TVOC was evaluated. The mechanical, optical and chemical properties of 4 kinds of paper (acid and neutral-based printing paper, traditional Hanji, and filter paper) were directly and indirectly affected by gaseous harmful materials. The brightness and $L^*$ value in all papers were slightly increased by accelerated aging under gaseous HCHO and TVOCs, but highly decreased by conditions under gases $NO_2$ and $SO_2$. The optical properties of paper records were most vulnerable in acid-based paper and high stable in filter paper and traditional Hanji by air pollutant degradation. The aging treatments under mixed gas pollutants including $NO_2$ resulted in decrease of physical, mechanical and optical properties of paper, so it was supposed that the concentration of $NO_2$ gas would be strictly controlled for optimum indoor air quality management in domestic storage centers for paper records.

A Study on Risk Communication and Risk Perception in Environmental Problems (환경문제의 위해도 인식과 위해도 홍보 프로그램의 효과분석 -라돈과 다이옥신을 중심으로-)

  • 김진용;신동천;박성은;임영욱;황만식
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.4
    • /
    • pp.315-324
    • /
    • 2002
  • Risk communication can be defined as the exchange of information about the nature, magnitude, significance, acceptability, and management of risk. The effect of risk communication on the perception and knowledge towards risk of environmental pollutants and it's related factors were investigated in this study. To investigate perception and knowledge of students and teachers towards risk of environmental pollutants, we conducted the survey using self-administrated questionnaire. The subjects were 574 for the first survey and 465 for the seconds survey from May to June, 2000. The main methods of transmission used in this study- through video tape, visual materials, question and answer, and participation in measuring pollutants - were not a one - way street. But an interactive process where information and opinions were exchanged among individuals, groups, and institutions. Environmental pollutants measured with participation of study subjects was Radon in the class room. The concentration of Radon was measured using E -PERM Device by installing it at each site for about 5 days. Subjects showed much interest in environmental pollution. Also, more than 98% of total subjects were perceived as Korea is seriously contaminated at present. By risk communication activity, risk perception of all subjects about Radon was increased, on the other hand, risk perception of Dioxin was decreased except for elementary student. Moreover, knowledge of all subjects about environmental risk was significantly increased (p =0.0001) and effort of reducing environmental pollution was more increased (p<0.05). There is need to further develop, refine, and integrate these approaches environmental risk communication study, there is an even more pressing need to accelerate the diffusion of environmental risk communication practice into government and organizations.

The Investigation and Comparison of Characteristics of Air Pollution for Cohort Study in Chungju with Industrial Cities (대조코호트 연구를 위한 충주의 대기오염현황 조사와 산단지역과의 비교)

  • Kim, Jae-Hoon;Wee, Seong-Seung;Nam, Sang-Hoon;An, Jung-Sun;Kim, Dae-Sun
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.1
    • /
    • pp.1-11
    • /
    • 2008
  • The purpose of this study was to investigate air quality in Chungju, Korea, using data obtained with a local air quality monitoring system. We have utilised cohort studies to investigate the relations between environmental pollution and the health of residents near large industrial complexes since 2004. This study analyzes the $O_3,\;NO_2,\;SO_2,\;CO\;and\;PM_{10}$ concentration in Chungju from 2002 to 2006. Air pollutants are closely related to the number of manufacturing facilities and cars, energy utilization and weather conditions. Generally, the diurnal concentration of air pollutants in Chungju reached the highest level in the morning (about$08:00{\sim}$) and early evening (about$19:00{\sim}$). On the other hand, the diurnal concentration of ozone as recorded gives the highest amount in late afternoon (about$16:00{\sim}$) and lowest in early morning (about$08:00{\sim}$). The concentration of air pollutants in Chungju was highest from winter to spring and lowest during the summer season. On the other hand, the monthly variation of ozone concentration was greatest in June and smallest in December. Also the, $PM_{10}$ concentration posted the highest record in April and the lowest during September. In general, this study analyzed air pollution changes in Chungju as well as in large scale industrial complex regions within Korea such as Ulsan, Pohang, Kwangyang, Sihwa Panwol and Gangneung in Korea. We compared the air quality of Chungju with those of these cites and found that air pollutants except for CO in Chungju was generally lower than large industrial complex regions.

The Aerosol Characteristics in Coexistence of Asian Dust and Haze during 15~17 March, 2009 in Seoul (짙은 황사와 연무가 공존한 대기의 에어러솔 특성 - 2009년 3월 15~17일 -)

  • Lee, Hae-Young;Kim, Seung-Bum;Kim, Su-Min;Song, Seung-Joo;Chun, Young-Sin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.2
    • /
    • pp.168-180
    • /
    • 2011
  • The variation of the physicochemical properties of atmospheric aerosols in coexistence of the heavy Asian Dust and Haze observed from $15^{th}$ to $17^{th}$ March 2009 in Seoul was scrutinized through the mass and ion concentration observations and synoptic weather analysis. Although the ratio of PM1.0/PM10 was constant at 0.3 (which is typical during Asian Dust period in Korea) during the measurement period, both PM10 and PM1.0 mass concentrations were 3~6 times and 2~4 times higher than that of clear days, respectively. Water-soluble ion components accounted for 30~50% of PM10 and 50~70% of PM1.0 mass concentration. One of the secondary pollutants, $NO_3^-$ was found to be associated with $Ca^{2+}$ and $Na^+$ in coarse mode indicating that the aerosol derived from natural source was affected by anthropogenic pollutants. While the acidity of the aerosols increased in fine mode when the stagnation of weather patterns was the strongest (March $16^{th}$), the alkalinity increased in coarse mode when new air masses arrived with a southwestern wind after ending a period of stagnation (March $17^{th}$). In the selected case, SOR (Sulfur Oxidation Ratio, $nSO_4^{2-}/[nSO_4^{2-}+nSO_2]$) and NOR (Nitrogen Oxidation Ratio, $nNO_3^-/[nNO_3^-+nNO_2]$) values of ion components were higher than the general values during Asian Dust period. These results imply that dust aerosols could be mixed with pollutants transported from China even in heavy Asian Dust cases in Korea.

Concentrations of Air Pollutants Measured at Kosan during ACE-Asia Intensive Observation Period (ACE-Asia 집중관측기간에 제주고산에서 측정한 대기오염물질의 농도 분포특성)

  • ;;;;Jianzhen Yu;Keith Bower
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.6
    • /
    • pp.487-501
    • /
    • 2002
  • The concentrations of gaseous (NO$_{x}$, SO$_2$, and $O_3$) and particulate (Elemental Carbon, EC and Organic Carbon, OC) pollutants were measured to evaluate the air quality of Kosan. Samples were taken at Kosan during ACE-Asia (Asian Pacific Regional Aerosol Characterization Experiment) IOP (Intensive Observation Period) (2001. 3. 21~2001. 5. 5). The mean concentrations of $O_3$(46.3$\pm$10.4 ppb) is higher than those at urban area such as Seoul and Busan in Korea. On the other hand, the mean concentrations of other gaseous species, NO$_{x}$(4.73$\pm$3.42 ppb) and SO$_2$(0.62$\pm$0.63 ppb) are lower than those at great cities. So we concluded that there are a few primary sources emitting atmospheric pollutants. The concentration of EC is higher and the concentration of OC is similar with or higher than those at other background sites. The recent EC concentration is higher than those measured before at Kosan. We concluded that there are more primary sources than other background sites and the amount of primary source have increased recently in Jeju. Backward trajectory and co..elation analysis were used to study where the air masses originated and distinguish the source of pollutants. While NO$_{x}$ and $O_3$ were mainly emitted and formed from Jeju inland area, concentrations of SO$_2$, OC and EC were affected by Asian Dust from China. Using the mean relative standard deviation of ozone, cleanness coefficient was obtained. The cleanness coefficient value, is 1.6 times larger than the value in 1992. Recently, the air quality of Kosan has been contaminated because of the Asian Dust events since spring and the rapid industrialization development.pment.

COD Pollutants Load Estimation Schemes in Lake Shihwa and Incheon Coastal Zone (시화호 및 인천연안의 COD 오염부하량 추정기법)

  • Cho Hong-Yeon;Cho Bum-Jun
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.18 no.3
    • /
    • pp.262-267
    • /
    • 2006
  • For the concentration management in COD parameters, it requires the measurement and estimation of the COD pollutants load (hereinafter PL) in the watershed. The estimation method of the PL, however, is provided only based on the BOD parameters. The development of COD PL estimation schemes is expected to execute total PL management in coastal zone and needs to more observation and much time. This study provides COD PL estimation schemes using statistical information about ratio analysis with COD & BOD concentration of rivers and drainages of an industrial complex in Lake Shiwha and Incheon Coastal Zone watershed. The COD PL is computed with ease by multiplying the conversion factor, which is calculated as the sum of the average and 1 to 3 (safety factors) times standard deviation. The conversion factor of Lake Shihwa and Incheon Coastal Zone is estimated as 1.7, 2.3 and 2.9 with respect to the safety factor 1, 2, and 3, respectively.

Characterization of Air Quality in Various Types of Indoor Environments in Urban Areas - Focusing on Homes, Offices, and Restaurants - (도시지역 실내환경 유형별 공기질 특성 평가 -가정, 사무실 및 식당을 중심으로-)

  • 백성옥;김윤신
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.4
    • /
    • pp.343-360
    • /
    • 1998
  • In this study, comprehensive air quality monitoring was undertaken with a variety of objectives to collect data on the levels of various indoor and ambient air quality parameters in the urban areas of Seoul and Taegu. The sampling sites were comprised of six offices, six residences and six restaurants in each city. The ambient air adjacent to the indoor sites was also simultaneously sampled for the same constituents. The sampling was conducted in two phases: summer of 1994 and winter of 1994/95. A range of air quality parameters were measured simultaneously, which include RSP, CO, COB, NOB, a range of VOC, airborne microbials, temperature, and relative humidity. The indoor and ambient levels of the pollutants measured in this study varied widely between the three types of environments studied. Comparison of median values for the three groups revealed that restaurants had higher indoor levels of most pollutants than homes or offices. There was also a clear pattern of the indoor levels of target pollutants being higher than those outdoors, particularly in restaurants. Concentrations of CO and most of the VOC were found to be significantly higher in the commercial districts, indicating the influence of vehicle exhaust emissions. A very wide range of VOC levels was documented in this study. Although median indoorloutdoor ratios indicated a generally increasing level of VOC indoors when compared to those outdoors, no statistically significant differences were found between indoor and outdoor VOC levels in homes and offices, implying the importance of ambient air quality in determining the quality of indoor air for homes and offices in urban areas. In addition, there was a general pattern of increasing concentrations from summer to winter, and similarly from outdoor to indoor air for nearly all target compounds. The seasonal differences in median levels were very clearly seen for fuel combustion related pollutants such as RSP, CO and VOC, this being attributed to the effects of increased fuel consumption during the cold season and to meteorological factors.

  • PDF

Effect of Awareness on the Change of Polluting Emission - Analysis of the Environmental Kuznets Curve Hypothesis- (인식수준이 환경오염물질 배출량 변화에 미치는 영향 -환경쿠즈네츠 곡선 가설 연구-)

  • Kang, Heechan
    • Environmental and Resource Economics Review
    • /
    • v.22 no.3
    • /
    • pp.437-457
    • /
    • 2013
  • The purpose of this study is to explain the causes of the phenomenon that the Environmental Kuznets Curve hypothesis suggests that the increasing the emissions level of environmental pollutants starting to decrease as a certain income level is reached, associating microeconomic variables such as awareness level. Effects of the level of awareness differs depending on the characteristics of the impacts of pollutants- either regional or global. Furthermore, the study identifies that the impacts on the change in emissions inventory differ. The study empirically examines and concludes that the turning point where the emission level of environmental pollutants starts to decrease is over- or under-estimated if the differing responses between the level of awareness and its effect on pollutants are ignored. In addition, the level of emissions starts to decrease at a lower level of income in case of regional effect from pollutant than the global effect from it. Finally, the study implies that investing more efforts and resources to improve the level of people's awareness on environmental quality is effective if the government is to alter the increasing path of emission level.

Evaluation of biodegradability according to bait type for crab pots (꽃게 통발용 미끼의 형태에 대한 생분해도 평가)

  • Jeong, Byung-Gon;Chang, Ho-Young;Koo, Jae-Geun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.44 no.1
    • /
    • pp.20-30
    • /
    • 2008
  • In order to evaluate the biodegradability of bait used in the pot for swimming crab, water tank experiments were conducted. Mackerel is the most commonly used natural form of bait to catch the swimming crabs, and therefore was used in this experiment for the biodegradability according to the manufacturing process of the bait. From the biodegradability test on chemical oxygen demand(COD), total nitrogen(T - N), total phosphorus(T - P), ammoniac nitrogen, nitrite nitrogen and nitrate nitrogen per unit weight of the bait based on the production rate and the accumulated amount of pollutants, it was concluded that the smaller the size of the mackerel pieces, the higher the production rate and accumulated amount of organic matter and nutrients which was unfavorable to water pollution. The amount of pollutants released from the intestine of the tuna was similar with that from the whole mackerel. For the operation period of 111 days, the accumulated concentrations of tested pollutants from the tuna which were 67.3 mgCOD/g d, 86.4 mgT N/g d, 3.1 mgT - P/g d, were almost half comparing with those from the mackerel which were 65.7 - 94.4 mgCOD/g d, 83.8 - 109.4 mgT - N/g d, 3.1 - 5.2 mgT - P/g d. The amount of pollutants released from the intestine of the tuna was slightly less than that from the mackerel that was cut into 8 pieces. but more than that from the mackerel which was not cut into pieces. Therefore, it can be concluded that the key factor in determining water pollution potential is not the kind of bait, but the processing or preparation method used.