• Title/Summary/Keyword: Pollutants

Search Result 4,227, Processing Time 0.026 seconds

Wastewater Treatment Process Study for Used Diaper Recycling (사용 후 기저귀 재활용을 위한 폐수처리방안 연구)

  • Kim, Kyung Shin;Lee, Ho Sun
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.47 no.2
    • /
    • pp.24-33
    • /
    • 2015
  • This study aims to suggest wastewater treatment options for diaper recycling by identifying characteristic analysis of wastewater from diaper recycling process and efficiency evaluation of wastewater treatment units. The wastewater characteristic analysis showed that the concentration of organic pollutants and ionic materials were very high comparing to seawater. Through the investigation of similar wastewater treatment, six treatment units were identified to reduce pollutants. It is found UF(ultra-filtration), DAF(dissolved air flotation), fenton oxidation, electro-coagulation and chemical-coagulation are effective in reducing organic pollutants while membrane system and ion exchanger are effective in reducing ionic materials. Even though the target of water quality should be secured in terms of managing organic pollutants level, the application of treatment unit for reducing ionic material needs lots of considerations. This result suggests that reuse of pulping wastewater after controlling organic pollutants is better than direct discharge of pulping wastewater. To select the appropriate wastewater treatment unit, an economic analysis about operation condition, wastewater flow, cost, efficiency should be considered.

Simultaneous Analysis of Pesticide Priority Pollutants in Soil (토양 중의 Pesticide Priority Pollutants 동시 분석에 관한 연구)

  • Lee, Seung-Seok;Park, Young-Joo;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.237-248
    • /
    • 1995
  • The simultaneous analysis of 16 organic pesticides, which are listed as a part of 129 priority pollutants by EPA(Environmental Protection Agency), was performed by GC-ECD(electron capture detector) and GC/MS-SIM(selected ion monitoring). Two extraction procedures from SW-846, sonication extraction and Soxhlet extraction, were somewhat modified and compared as an extraction and concentration method for the analysis of priority pollutants in soil. Accuracy and precision of the methods were reported from the calculation of mean recovery, mean relative standard deviation, and method detection limit.

  • PDF

Behavior of Indoor Organic Pollutants Dissolved into the Ringer's Solution (수액제에 유입되는 실내 유기오염물질의 거동)

  • 김만구;정영림
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.3
    • /
    • pp.315-322
    • /
    • 1996
  • Recently, hospital acquired infections have an increase interest as a public problems, which are caused of indoor pollutants in hospital. Microorganisms, ethylene oxide, formaldehyde, and anesthetic gases are main hazardous pollutants in hospital. The possible pathways of the infection are a respiratory channel as well as a blood channel. The blood channel is concerned since these pollutants might be dissolved into the Ringer's solution. The objective of this research was to evaluate the removal efficiencies of adsorption trap for formaldehyde and microorganisms as indoor pollutants which permeated into the Ringer's solution. Dissolved formaldehyde in the solution was increased with the injection dose time. The amount of dissolved formaldehyde was 67.5 $\pm$ 9.5% in Ringer's solution when injection dose time was controlled about 7hrs. An adsorption trap was designed for preventing formaldehyde and microorganisms to be permeated into Ringer's solution. The adsorption trap was packed with 0.4g of active carbon (60/80 mesh) in a sterilized plastic tube (7.79 cm length, 0.46 cm i.d.) and both ends were packed with glass wool. Devised infusion set equipped with the adsorption trap showed 99.9% of removal efficiency for formaldehyde. Microorganism numbers detected on sterilized water for injection and 5% dextrose infusion used in the hospital were 2,695 $\times 10^3$ cells/l and 4,190 $\times 10^3$ cells/l, respectively. Removal efficiency by the adsorption trap was 92.3 $\pm$ 8.5% as for microorgnisms.

  • PDF

Evaluation of Acid Rain through the Scavenging Theory and Application of Trajectory Model (세정이론을 통한 산성비의 평가와 발원지 추적)

  • Kim, Jeong-Soo;Kang, In-Goo;Chang, Sung-Kee
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.8 no.2
    • /
    • pp.121-127
    • /
    • 1992
  • This study was carried out to investigate the features of air pollutants in rainwater and trace their transported trajectories from other countries. Chemical analysis data of rainwater and suspended particulates collected at Seoul, Kanghwa, and Taean for three years were used to evaluate the effects of long-range transport of air pollutants. Scavenging theory on washout and rainout effect during a rainy period was applied to estimate whether pollutants in the precipitation were long-range transported or not. On the other hand, precipitation weighted surface wind were evaluated to analyze the effect from local sources on atmospheric concentrations. As a result, contribution of air pollutants caused by anthropogenic sources in the precipitation which was identified to be long range transported was confirmed significantly high and trajectory of these pollutants was to be equivalent to 850mb isobar. Although concentration of acidifying components increased in the precipitation, neutralization by alkaline soil components such as $Ca^{2+}$ and $Mg^{2+}$ was conspicuous especially during Yellow-sand period.

  • PDF

Effects of Rain Gardens on Removal of Urban Non-point Source Pollutants under Experimental Conditions (실험실 조건에서 레인가든의 도시 비점오염물질 제거효과)

  • Kim, Changsoo;Sung, Kijune
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.5
    • /
    • pp.676-685
    • /
    • 2012
  • As impermeable layer continues to increase with the urbanization process, direct input of nonpoint source pollutants into water bodies via stormwater has caused serious effects on the aquatic ecosystem. Potential applications of rain gardens are increasing not only as best management practices (BMP) for reducing the level of nonpoint source pollutants but also as an ecological engineering alternative for low impact development (LID). In this study, remediation performance of various planting types, such as a mixed planting system with shrubs and herbaceous plants, was assessed quantitatively to effectively manage stormwater and increase landscape applicability. The mixed planting system with Rhododendron lateritium and Zoysia japonica showed the highest removal performance of $76.9{\pm}7.6%$ and $58.4{\pm}5.0%$ for total nitrogen and $89.9{\pm}7.9%$ and $82.4{\pm}5.2%$ for total phosphorus at rainfall intensities of 2.5 mm/h and 5.0 mm/h, respectively. The mixed planting system also showed the highest removal performance for heavy metals. The results suggest that a rain garden with the mixed planting system has high potential applicability as a natural reduction system for nonpoint source pollutants in order to manage stormwater with low concentrations of pollutants and will increase water recycling in urban areas.

Study on Discharge Characteristics of Water Pollutants among Industrial Wastewater per Industrial Classification and the Probability Evaluation (업종별 산업폐수중 수질오염물질 배출 특성 및 개연성 평가 연구)

  • Ahn, Tae-ung;Kim, Won-ky;Son, Dae-hee;Yeom, Ick-tae;Kim, Jae-hoon;Yu, Soon-ju
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.1
    • /
    • pp.14-24
    • /
    • 2016
  • Information on the lists of pollutants from industrial wastewater discharge are essential not only to specify the key pollutants to be managed in permission process but to design the treatment facilities by the dischargers. In this study, wastewater quality analysis was conducted for three industrial categories including the specified hazardous water pollutants. The general description of the wastewater occurrence, major sources, treatment facilities are also investigated to obtain integrated database on the pollutant inventories for the industrial categories. In addition Based on the analysis of raw wastewater and final effluent, the detected pollutant items are confirmed by analyzing their presence in the raw or supplement materials, the potential of formation as byproducts, and the possibility of inclusion as impurities. The three industrial categories include petrochemical basic compounds, basic organic compounds, and thermal power generation. The water pollutants emitted from petrochemical basic compound manufacturing facilities are 31 items including 16 specified hazardous water pollutants. Basic organic compound manufacturing facilities discharge 30 kinds of pollutants including 14 specified hazardous water pollutants. Thermal power generation facilities emit 20 pollutants, 8 specified hazardous water pollutants among them. These substances were decided as emission inventories of water pollutants finally through the probability evaluation. The compounds detected for each categories are screened through investigation on the possible causes of their occurrence and confirmed as the final water pollutant inventories.

A prediction study on the number of emergency patients with ASTHMA according to the concentration of air pollutants (대기오염물질 농도에 따른 천식 응급환자 수 예측 연구)

  • Han Joo Lee;Min Kyu Jee;Cheong Won Kim
    • Journal of Service Research and Studies
    • /
    • v.13 no.1
    • /
    • pp.63-75
    • /
    • 2023
  • Due to the development of industry, interest in air pollutants has increased. Air pollutants have affected various fields such as environmental pollution and global warming. Among them, environmental diseases are one of the fields affected by air pollutants. Air pollutants can affect the human body's skin or respiratory tract due to their small molecular size. As a result, various studies on air pollutants and environmental diseases have been conducted. Asthma, part of an environmental disease, can be life-threatening if symptoms worsen and cause asthma attacks, and in the case of adult asthma, it is difficult to cure once it occurs. Factors that worsen asthma include particulate matter and air pollution. Asthma is an increasing prevalence worldwide. In this paper, we study how air pollutants correlate with the number of emergency room admissions in asthma patients and predict the number of future asthma emergency patients using highly correlated air pollutants. Air pollutants used concentrations of five pollutants: sulfur dioxide(SO2), carbon monoxide(CO), ozone(O3), nitrogen dioxide(NO2), and fine dust(PM10), and environmental diseases used data on the number of hospitalizations of asthma patients in the emergency room. Data on the number of emergency patients of air pollutants and asthma were used for a total of 5 years from January 1, 2013 to December 31, 2017. The model made predictions using two models, Informer and LTSF-Linear, and performance indicators of MAE, MAPE, and RMSE were used to measure the performance of the model. The results were compared by making predictions for both cases including and not including the number of emergency patients. This paper presents air pollutants that improve the model's performance in predicting the number of asthma emergency patients using Informer and LTSF-Linear models.

Risk-based Priority Ranking for Air Pollution Problems in Seoul (서울 지역에서 인체 위해도에 입각한 대기오염물질의 관리 우선 순위 선정에 관한 연구)

  • 김예신;박화성;이용진;임영욱;신동천
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.2
    • /
    • pp.205-216
    • /
    • 2003
  • We have gathered exposure data on ambient air quality level and investigated dose-response slope factors of air pollutants such as fine particle, HAPs (metals, VOCs, PAHs) and dioxins in Seoul. Theoretical mortality incidences were estimated from exposure to these pollutants. From the results, priorities were ranked in the order fine particle, metals, VOCs, dioxins and PAHs by ordinal scale, and the uncertainties relative to those risk estimates were described.

A Study on the Photochemical Reaction Model of Air Pollutants (大氣汚染物質의 光化學 反應 모델에 關한 硏究)

  • 이화운;박종길
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.8 no.1
    • /
    • pp.74-83
    • /
    • 1992
  • Photochemical reactions are important for the diurnal variation of the concentrations of air pollutants in the urban atmosphere. A photochemical reaction model was developed, which includes in terms of the effective chemical reaction. Various experimental results were introduced to the construction of model. To verify the applicability of the model, the simulated results were compared with those observed. By comparing the simulated results with those observed, it was shown that those two are in good agreement qualitatively. As a result, the photochemical reaction model which has been developed in this study is found to be useful for the prediction of concentrations of air pollutants in the atmosphere.

  • PDF

The Pollution Potential of Animal Production Systems : Origin and Atmospheric Cycling of Their Pollutants (축산환경의 오염 잠재력 : 축산오염 물질의 발생과 대기환경계 순환)

  • 김기현;김동균;윤종만
    • Journal of Animal Environmental Science
    • /
    • v.1 no.2
    • /
    • pp.155-164
    • /
    • 1995
  • Despite considerable progresses made in our understanding of environmental fate of pollutants stemming from animal production systems, relatively little is known about the processes and mechanisms regulating their dispersement (via emission) into and deposition from the earth's atmospheric system. Here we present and summarize up-to-date knowledge on this topic with a main emphasis on their origin, physico-chemical characteristics, and geochemical distribution behavior.

  • PDF