• Title/Summary/Keyword: Pollutant removal efficiency

Search Result 208, Processing Time 0.038 seconds

Economical Ventilation Effectiveness to Reduce Hazardous Chemical Emissions for a Nail-Salon Worker

  • KWON, Woo-Taeg;JUNG, Min-Jae;LEE, Woo-Sik;KWON, Lee-Seung;SO, Young-Jin
    • Journal of Distribution Science
    • /
    • v.17 no.7
    • /
    • pp.65-76
    • /
    • 2019
  • Purpose - The purpose of this study is to investigate economical ventilation effectiveness to reduce hazardous materials exposure and damage of workers by analyzing exposure amount of noxious substances under various ventilation conditions of nail salon for indoor environments. Research design, data, and methodology - This study was carried out with cooperation of Nail shop located in SeongNam city to involve an analysis of the environmental impact indoor air quality, pollutant exposure and economical cost-effectiveness in the nail workplace. The hazardous substances were PM-10(Particulate Matter-10㎛), VOCs(Volatile Organic Compounds) and Formaldehyde, which are the major materials of nail workplace. Results - PM-10 is reduced by about 60% with air cleaner, forced artificial ventilation by 32%, and natural ventilation by about 12%. TVOCs and Formaldehyde showed similar efficiency (80~100%) after natural ventilation and ventilation after 60 minutes. The removal efficiencies of VOCs and formaldehyde were similar to those of natural ventilation and mechanical ventilation system. However, in case of dust, natural ventilation was reduced by artificial ventilation system due to inflow of external dust during natural ventilation. Conclusions - If the pollution degree of outdoor air is not high, air volume is high, and natural ventilation is performed when the air conditioning and heating system is not operated. Even at the end of the work, it keeps operating for 60 minutes to remove the pollutants generated. Results of this analysis demonstrated that the worker environment can be improved by adopting institutional legislation and guidelines for ventilation.

Characteristics of VOCs Adsorption of Brick Prepared by MSWI Fly Ash (소각재로 제조한 건축외장재의 VOCs 흡착 특성 평가)

  • Ban, Hyo-Jin;Jeong, Jae-A;Lee, Woo-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.9
    • /
    • pp.857-861
    • /
    • 2010
  • Recently photochemical smog has become a serious urban air pollution. And VOC is the major pollutant for it. With the advance of industrialization and urbanization, MSWI fly ash and sewage sludge and melting slag were generated. It is necessary to de-toxificate ashes, because they contain many toxic constituents and probably lead to contaminate the environment. The objective of this research was to prepare multi-functional brick which is able to remove VOCs in ambient air. The bricks were made of MSWI fly ash, sewage sludge and slag. The benzene adsorption experiment by brick was acted to evaluate its adsorptivity. And also photocatalyst material was coated to enhance its adsorptivity and the endurance on the brick. According to the result, the benzene showed 74~96%. The removal efficiency was increased and the breakpoint time was lengthened by coating a brick.

Shipboard sewage treatment using Membrane Sequence Batch Reactor (MSBR을 이용한 크루즈선 오·폐수 처리 장치)

  • Kim, In-Soo;Lee, Eon-Sung;Oh, Yeom-Jae;Kim, Eog-Jo
    • Journal of Navigation and Port Research
    • /
    • v.34 no.5
    • /
    • pp.383-388
    • /
    • 2010
  • Lab scale experiment study was carried out for biological process development on cruise. SBR(Sequence Batch Reactor), MBR(Membrane Bioreactor), and MSBR(Membrane Sequence Batch Reactor) system were investigated for practical application on shipboard sewage treatment. From the results it was suggested that MSBR system might be suitable process for cruise in terms of pollutant removal efficiency, maintenance and special environmental conditions of cruise. About 99% of BOD, 98% of COD and 99% of SS were removed in MSBR system. In addition, about 76% of total nitrogen was reduced and the total phosphorus reduction averaged 59%.

A Study on the Treatment of Swine Wastewater by Using Intermittently Aerated Activated Sludge Process (간헐폭기법에 의한 돈사 폐수 처리에 관한 연구)

  • Yang, Tae-Du;Lee, Mi-Kyung;Chung, Yoon-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.4
    • /
    • pp.86-96
    • /
    • 1998
  • In this study, an intermittently aerated activated sludge process, modified process from conventional activated sludge process, was developed to treat high strength swine wastewater, which has been blamed as major pollutant for stream pollution. Therefore, the optimum cycle for oxic and anoxic period, SRT, and OLR were studied as design parameters. The effects of different time interval for oxic and anoxic period on nitrification and denitrification were examined by operating two reactors with 60/60min and 60/90min as oxic/anoxic period. Although the reactor with 60/60min showed complete denitrification of $NO_x-N$ generated during oxic period, the reactor with 60/90min showed incomplete nitrification due to the inactivity of nitrifier by accumulated $NH_3-N$ toxicity during anoxic period. Therefore, it is recommended to operate same interval for oxic and anoxic period. In order to determine the optimum cycle for oxic/anoxic period, four different reactors with 30/30, 60/60, 90/90 and 120/120min were examined. The reactor operation with 90/90min was optimum to get the most stable results in this study. However, the optimum cycle for oxic and anoxic period should be changed with characteristics of influent wastewater and operating conditions. According to lie operation results of three reactors with SRT of 15, 20 and 30days. The reactor with 2Odays SRT showed best removal efficiency of T-N. The optimum OLR would be $2.5Kg\;COD/m^3/day$ which showed the most stable nitrification and denitrification. Since characteristics of influent wastewater in the real system has a severe fluctuation, so it is very difficult to determine each interval for oxic and anoxic period. Therefore, ORP curves, describing the change of oxidation/reduction potential in reactor, can be used as a control parameter for automatic control of oxic and anoxic period. In other words, bending point (Nitrate Knee) of ORP curve during anoxic period could be used as a starting point of oxic period.

  • PDF

Evaluation of Pollutant Removal efficiency for Watershed Scale According to Application of BMPs by Crop Land (유역단위 경작지별 비점오염저감시설 저감 효율 평가)

  • Lee, Gwanjae;Lee, Seoro;Yang, Dongseok;Lee, Jimin;Lim, Kyoung Jae;Jang, Won Seok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.404-404
    • /
    • 2021
  • 기후변화에 따른 물 순환과정의 변화는 유역내 강우패턴 및 강우강도, 유출 특성에 큰 영향을 미친다. 유역내 강우패턴 및 강우강도 등 물 순환과정의 변화는 강우에 의한 유출과 밀접한 관련이 있는 비점오염원에 중대한 영향을 미친다. 특히, 고랭지밭에 밀집되어 있어 강우에 따른 토사로 인한 탁수가 빈번하게 문제가 되고 있는 소양호 유역은 비점오염원관리지역으로 지정되어 탁수를 저감하기 위해 많은 노력을 기울이고 있는 실정이다. 이러한 노력들 중 환경부에서는 개별 경작지마다 BMPs(Best Management Practices)를 적용하여 강우에 의한 탁수를 저감하고자 하였으며, 앞으로도 지속적으로 설치할 계획에 있다. 그러나 이러한 비점오염저감시설을 적용하였을 때의 저감효율은 밭의 면적이나 경사도, 경사장 등 다양한 조건을 고려해야 하는 어려움이 있어, 이에 대한 연구는 매우 제한적으로 이루어져 왔다. 이에 따라, 각 경작지에 적용된 개별 비점오염저감시설이 유역 말단에 미치는 영향에 대한 연구 역시 미비한 실정이다. 그러나 비점오염저감대책 및 계획은 유역 말단을 기준으로 하는 경우가 많고, 유량 및 수질에 대한 모니터링 자료 역시 유역 말단에 위치하기 때문에 개별 비점오염저감시설이 유역 말단에 미치는 영향에 대한 연구는 매우 중요하다고 할 수 있다. 따라서 본 연구에서는 유역단위 평가모델 중 하나인 SWAT을 이용하여 각 경작지 별로 실측 경사장 및 경사도, 개별 비점오염저감시설을 적용하였으며, 개별 비점오염저감시설이 유역말단에 미치는 영향을 평가하였다.

  • PDF

Development of Domestic Rainwater Treatment System and its Application in the Field (소규모 빗물처리시설 개발 및 현장 적용성 평가 연구)

  • Pak, Gijung;Park, Minseung;Kim, Hwansuk;Lim, Yoonsoo;Kim, Sungpyo
    • Journal of Wetlands Research
    • /
    • v.18 no.1
    • /
    • pp.24-31
    • /
    • 2016
  • The increase of impervious area in cities caused the unbalanced water cycle system and the accumulated various contaminants, which make troubles as introducing into watershed. In Korea, most of rainfall in a year precipitate in a summer season. This indicate that non-point source pollution control should be more important in summer and careful rainfall reuse strategy is necessary. Accordingly, the aim of this study is to monitor the characteristics of rainfall contaminants harvested in roofs and to develop the rainfall treatment system which are designed to fit well in a typical domestic household including rain garden. The rain garden consists of peatmoss, gravel and san to specially treat the initial rainfall contaminants. For this purpose, lab scale experiments with synthetic rainfall had been conducted to optimize the removal efficiency of TN, TP and CODcr. After lab scale experiments, field scale rainfall treatment system installed as a pilot scale in a field. This system has been monitored during June to July in 2015 in four time rainfall events as investigating the function of time, rainfall, and pollutant concentrations. As results, high loading of pollutants were introduced to the rainfall treatment system and its removal efficiency is increased as increase of pollutant concentrations. Since it is common that the mega-size of rainfall treatment system is not attractive in urban area, small scale rainfall treatment system is promising to treat the non-point source contaminants from cities. In addition, this small scale rainfall treatment system could have a potential to water resue system in islands, which usually suffer the shortage of water.

Optimum Capacity of Retention Basin for Treating Nonpoint Pollutants and Its Removal Efficiency in Industrial Complex Areas (산업단지내 비점오염물질 처리를 위한 적정 저류조 용량 산정 및 처리효율)

  • Kim, Lee-Hyung;Lee, Byung-sik;Kwon, Soo-Youl
    • Journal of Wetlands Research
    • /
    • v.7 no.3
    • /
    • pp.75-85
    • /
    • 2005
  • The Construction of industrial complex areas means the increase of imperviousness rate and the increase of nonpoint pollutant emissions during a rainfall. Generally the retention basin can become the alternative for removing and controling these nonpoint pollutants. Recently Ministry of Environment are trying to change the purpose of retention basins from flooding control to nonpoint pollutant control. In order to propel the stormwater management program, administration plan of stormwater management is enacted in Spring, 2005. Hereafter, in a newly developing area, the best management practices should be established to control the nonpoint pollutant. Landuses of the research area are classified to the categories of the 1st manufacturing industry, metal industry, fiber and chemical product manufacturing industry, etc. Therefore, this research was performed to understand washed-off characteristics of stormwater and to suggest the controling method of nonpoint pollutants. The optimum capacity of the retention basin can be determined by analyzing the relationships among data of rainfall, runoff, washed-off pollutants from the areas. The rainfall analysis using the data of normal year, recent 2, 5 and 10 years shows that the 80% rainfall frequency was occurred on 10mm accumulated rainfall, but which is not considered the first flush effect. However, by considering the first flush effect, the appropriate treatment capacity of rainfall can be decreased to 4-5mm accumulated rainfall. Using the criteria, the optimum capacity of retention basin is determined to $12,000m^3$ in the research area. The washed-off nonpoint pollutant loading from the areas have beeb calculated to 435ton/yr for TSS, 238ton/yr for COD, 8,518kg/yr for TKN and 1,816kg/yr for TP. The mass of 78.3ton/yr for TSS, 20.4ton/yr for BOD, 128.6ton/yr for COD, 4.6ton/yr for TKN and 980kg/yr for TP can be reduced by constructing the retention basin. The sediment accumulation rate is also calculated by $6.53kg/m^2-hr$.

  • PDF

Review of the CO2 Geological Storage Using Nanoparticle-stabilized CO2 Foam (나노입자기반 CO2 폼을 이용한 CO2 지중저장에 대한 기술적 고찰)

  • Son, Han Am
    • Economic and Environmental Geology
    • /
    • v.53 no.2
    • /
    • pp.213-220
    • /
    • 2020
  • When CO2 foam is injected into the saline aquifer, the relative permeability of CO2 decreases and its viscosity increases, thereby reducing mobility in porous media and ultimately improving CO2 storge with enhanced sweep efficiency. In general, surfactants were used to fabricate CO2 foam. Recently, nanoparticles have been used to form stable foam than surfactant. This paper introduces CO2 storage technology using nanoparticle stabilized CO2 foam. If the surface of the hydrophilic nanoparticles is partially modified into a CO2-philic portion, the particles have an affinity for CO2 and water, thus forming a stable CO2 foam even in deep saline aquifers under high temperature and high salinity conditions, thereby it can be stored in the pores of the rock. In terms of economics, injection method using nanopaticle-stabilized CO2 foam is more expensive than the conventional CO2 injection, but it is estimated that it will have price competitiveness because the injection efficiency is improved. From an environmental point of view, it is possible to inject chemical substances such as surfactants and nanomaterials into aquifers or reservoirs for specific purposes such as pollutant removal and oil production. However, some studies have shown that nanoparticles and surfactants are toxic to aquatic animals, so environmentally proven substances should be used. Therefore, further research and development will be needed to study the production and injection of nanoparticle-stabilized CO2 foam that are environmentally safe and economically reasonable.

Evaluation of Pollutant Removal Efficiency in Environmentally Friendly Full-scale Constructed Wetlands for Treating Domestic Sewage during Long-term Monitoring (장기 모니터링을 통한 환경친화형 인공습지 하수처리장의 수질정화효율 평가)

  • Seo, Dong-Cheol;Jo, In-Seong;Lim, Seok-Cheon;Lee, Byeong-Ju;Park, Seong-Kyu;Cheon, Yeong-Seok;Park, Jong-Hwan;Lee, Hong-Jae;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.28 no.2
    • /
    • pp.97-105
    • /
    • 2009
  • A constructed wetland which was composed of aerobic and anaerobic areas was evaluated for 3 years to effectively treat the sewage produced in farming and fishing communities. For 3 years in a constructed wetland, biochemical oxygen demand(BOD), chemical oxygen demand(COD), suspended solids(SS), total nitrogen(T-N), and total phosphorus(T-P) in effluent were 0.2${\sim}$11.8, 1.0${\sim}$41.9, 1.1${\sim}$6.5, 4${\sim}$60 and 0.02${\sim}$3.51 mg/L, respectively. Removal rate of BOD, COD and SS in effluent were 97, 92 and 99%, respectively, in the third year. As time goes by, removal rate of T-N and T-P in treated water in aerobic area and effluent were gradually increased in a constructed wetland. In the third year, removal rate in effluent were 62 and 73%, respectively. By the seasons, removal rate of BOD, COD, SS, T-N and T-P were 97${\sim}$98, 87${\sim}$91, 99, 43${\sim}$61 and 76${\sim}$86%, respectively. Removal rate of BOD, COD, SS and T-P were not affected by the seasons, but that of T-N in winter and spring were decreased than the other seasons.

Comparative Studies Of the $UV/H_2O_2,\;UV/TiO_2/H_2O_2$ and Photo-Fenton Oxidation for Degradation of Citric Acid ($UV/H_2O_2,\;UV/TiO_2/H_2O_2$, Photo-Fenton 산화방법에 의한 Citric Acid의 분해효율 비교)

  • Seo, Min-Hye;Cho, Soon-Haing;Ha, Dong-Yun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.4
    • /
    • pp.429-437
    • /
    • 2006
  • To establish the efficient treatment technology of chemical cleaning wastewater from power plant, several AOPs($UV/H_2O_2,\;UV/TiO_2/H_2O_2$, Photo-Fenton oxidation) were investigated. Treatment efficiencies and the electrical energy requirements based on the EE/O parameter(the electrical energy, required per order of pollutant removal in $1m^3$ wastewater) were evaluated. TOC removal efficiencies of $UV/H_2O_2,\;UV/TiO_2/H_2O_2$, Photo-Fenton oxidation at the optimum conditions were 95.5%, 92.3%, 91.5%, respectively. The electrical energy requirements of $UV/H_2O_2,\;UV/TiO_2/H_2O_2$, Photo-Fenton oxidation were $11.26kWh/m^3,\;3.85kWh/m^3,\;0.799kWh/m^3$, respectively. From these results, it could be concluded that all of the three oxidation processes were effective for the degradation of citric acid. Considering the treatment efficiency and economical aspect, photo-Fenton oxidation was the most efficient treatment process among the three processes tested.