• 제목/요약/키워드: Pollutant loading estimate

검색결과 45건 처리시간 0.028초

Pollutant Loading Estimates from Watershed by Rating Curve Method and SWMM

  • Jeon, Ji-Hong;Yoon, Chun-Gyeong
    • 한국환경농학회지
    • /
    • 제19권5호
    • /
    • pp.419-425
    • /
    • 2000
  • Rating curve method and SWMM (Storm Water Management Model) were applied to estimate pollutant loading from Hwa-Ong watershed in Kyunggi-Do. Rating curves were derived from sampling sites and applied to the whole watershed. SWMM version 4.4 was calibrated by field data of sampling sites and applied to the whole watershed. The pollutant loading estimated by rating curve was slightly higher than the one by SWMM, but the difference was not significant considering diffuse pollution characteristics of wide variation. Land use effect of the subcatchments could not be incorporated logically in rating curve method and difficulty in extrapolation was experienced, therefore, the estimate by rating curve method was thought to be less confident. SWMM was satisfactory in estimation of pollution loading, and its great flexibility worked well to describe complex nonurban land uses. Neither of them could exactly describe complex natural phenomena, but SWMM was preferred in this study due to its flexibility and logical hydrologic processes including land use effects. Use of reasonable watershed model rather than rating curve method for watershed pollutant loading estimate can be more practical and is recommended.

  • PDF

GIS를 이용한 유역별 오염부하량 산정시스템의 개발 (Development of Pollutant Loading Estimation System using GIS)

  • 함광준;김준현;심재민
    • 환경영향평가
    • /
    • 제14권3호
    • /
    • pp.97-107
    • /
    • 2005
  • The purpose of this study is to develop a system, which estimates watershed pollutant loading rate through the combination of GIS and computational mode. Also, the applicability of this study was estimated by the application of the above system for Chuncheon City. The detailed results of these studies are as follows; The pollutant loading estimation system was developed for more convenient estimation of pollutant loading rate in watershed, and the system load was minimized by the separation of estimation module for point and non-point source. This system on the basis of GIS is very economical and efficient because it can be applied to other watershed with the watershed map. System modification is not needed. The pollutant loading estimation system for point source was developed to estimate the pollutant loading rate in watershed through the extraction of the proper data from all districts and yearly data and the execution of spatial analysis which is main function of GIS. From the verification result of spatial analysis, real watershed area and the administrative districtarea extracted by spatial analysis were $1,114,893,340.15m^2$ and $1,114,878,683.68m^2$, respectively. It shows that the spatial analysis results were very exact with only 0.001% error. The pollutant loading estimation system for non-point source was developed to calculate the pollutant loading rate through the overlaying of land-use and watershed map after the construction of new land-use map using the land register database with most exact land use classification. Application result for Chuncheon City shows that the proposed system results in one percent land use error while the statistical method results in five percent. More exact nonpoint source pollutant loading was estimated from this system.

담수호 유입 오염부하량의 간척농지 영농 전.후 변화 예측 (Prediction of the Pollutant Loading into Estuary Lake according to Non-cultivation and Cultivation conditions of Reclaimed Tidal Land)

  • 윤광식;최수명;양홍모;한국헌;한경수
    • 농촌계획
    • /
    • 제7권1호
    • /
    • pp.27-36
    • /
    • 2001
  • Estimation of current and future loading from watershed is necessary for the sound management of water quality of an estuary lake. Pollution sources of point and non-point source pollution were surveyed and Identified for the Koheung watershed. Unit factor method was used to estimate potential pollutant load from the watershed of current conditions. Flow rate and water qualify of base flow and storm-runoff were monitored in the main streams of the watershed. Estimation of runoff pollutant loading from the watershed into the lake in current conditions was conducted by GWLF model after calibration using observed data. Prospective pollutant loading from the reclaimed paddy fields under cultivation conditions was estimated using the modified CREAMS model. As a result, changes of pollutant loading into estuary lake according to non-cultivation and cultivation conditions of reclaimed tidal land were estimated.

  • PDF

영산강 수계의 비점오염원에 관한 연구 I - 토지이용 및 강우를 중심으로 - (Non-Point Source Pollutions of the Youngsan River Basins I - The Method of Land-Use Types and Rainfall -)

  • 차진명;신성의;차규석
    • 환경영향평가
    • /
    • 제8권1호
    • /
    • pp.41-49
    • /
    • 1999
  • This study was carried out to estimate the runoff loading characteristics of the non-point source pollutions in the Youngsan river basins by the method of land-use types and rainfall. The lysimeter test, rainfall and stream flowmeter measurement were performed to develop the pollutant loading unit discharged from the non-point sources. As the non-point sources, the unit pollutant discharge rates were different from the land-use types such as paddy field, upland, forest, housing site and others. The pollutant loading units classified by land-use types in the Youngsan river basins are as follows: The total BOD loading rate is 15.3 ton/day and the housing site is discharged 50.6%, the total T-N loading rate is 6.0 ton/day and the paddy field and upland is discharged 77.6%, and the total T-P loading rate is 0.39 ton/day and the paddy field and upland is discharged 81.2%. The pollutant loadings by rainfall in the Youngsan river basins are about 7,425 ton/year of BOD, 324 ton/year of T-N and 118 ton/year of T-P, respectively.

  • PDF

다양한 회귀분석을 통한 강우유출용적에 따른 비점오염부하량 예측방안 (Predictive Relationships of the Nonpoint Source Pollutant Loads with Stormwater Runoff Volumes based on the Various Regression Analyses)

  • 신지웅;길경익
    • 한국물환경학회지
    • /
    • 제27권3호
    • /
    • pp.257-263
    • /
    • 2011
  • This study analyzes the correlations between non-point sources and runoff to estimate non-point sources for effective management. From the monitoring results, the correlation factors among pollutant mass loading, EMC, total runoff volume and average flow are calculated. And using correlation factors, the most related two constituents are determined. Also the most appropriate regression between two constituents are determined. Pollutant mass loading and total runoff volume has the highest correlation. Also, compound regression is found to be the most appropriate regression. This shows that pollutant mass loading increases as total runoff volume increases. It is not continuous increase but has some pattern.

오염부하량 산정을 위한 GWLF 모형의 적용 (Application of GWLF Model to Predict Watershed Pollutant Loadings)

  • 장중석;이남호
    • 농촌계획
    • /
    • 제7권1호
    • /
    • pp.77-88
    • /
    • 2001
  • In order to evaluate the applicability of GWLF model which can efficiently estimate non-point and point source pollutant loadings in rural watershed including urban district, the model was applied to an experimental watershed. The model was calibrated using observed data such as daily runoffs, sediment yields, T-N, and T-P. Simulated daily runoffs and sediment yields by the model using calibrated parameters were in food agreement with the observed data. There were difference between the simulated and observed nutrient loading which was considered resonable. The simulated results by the model showed that T-N, T-P and sediment yields were dependent on the amount of stream runoff discharge and land use. GWLF model is believed to applicable to estimate amount of pollutant loading of non-point source pollution for the water qualify control of agricultural watersheds.

  • PDF

STORM 모형을 이용한 비점오염원 부하의 규모와 특성에 관한 연구 (A Study on Scale and Characteristics of Nonpoint Pollution Using STORM Model)

  • 김도연;이홍근
    • 한국환경보건학회지
    • /
    • 제22권1호
    • /
    • pp.5-11
    • /
    • 1996
  • The more accurate estimation of the pollutant loadings from nonpoint source is needed to evaluate water quality of water resources such as river and reservoir. Therefore this study was performed to grasp the scale and characteristics of pollutant. In this study, STORM model was applied to I-cheon district to estimate runoff and pollutant loading of SS, BOD, T-N and $PO_4-P$. The results estimated by STORM model were fitted well to surveyed water quality in flow, SS and BOD. The annual loadings were estimated to be 36,463 kg/$km^3$/yr of SS, 8,090 kg/$km^3$/yr of BOD, 4,435 kg/$km^3$/yr of T-N and 358 kg/$km^3$/yr of $PO_4-P$. It was also found that the monthly pollutant loadings of SS, BOD, $PO_4-P$ were greatest in May and T-N in April.

  • PDF

채수빈도를 고려한 소하천의 수질오염부하량 특성 연구 (Variations of Estimated Pollutant Loading from Rural Streams with Sampling Intervals)

  • 강문성;박승우;윤광식
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.552-557
    • /
    • 1998
  • Sampling schemes are intended for use in situations where stream-flow data are collected regularly, but concentration data are collected during only a limited number of time periods. Estimating water pollutant loading considering sampling intervals is presented, and for illustrative purposes the criterion is applied to the sampling station HS#3 of the Balan-reservoir watershed which is located at the southwest of Suwon. The stratification is employed uniformly for all sampling strategies in that the strata boundaries are defined using the actual distribution of flow values and the selected nonexceedence probabilities to minimize inaccuracy. Ratio estimator for SS, T-N, and T-P were used in order to calculate the water pollutant loading. A sampling scheme incorporating stratified sampling with real-time of the sampling characteristics is found to give the appropriate estimate of the mass load.

  • PDF

BASINS/HSPF를 이용한 화성유역 오염부하량의 정량적 평가 (Quantitative Estimation of Pollution Loading from Hwaseong Watershed using BASINS/HSPF)

  • 정광욱;윤춘경;장재호;김형철
    • 한국농공학회논문집
    • /
    • 제49권2호
    • /
    • pp.61-74
    • /
    • 2007
  • A mathematical modeling program called Hydrological Simulation Program-FORTRAN (HSPF) developed by the United States Environmental Protection Agency (EPA) was applied to Hwaseong watershed. It was run under BASINS (Better Assessment Science for Integrating Point and Nonpoint Sources) program, and the model was validated using monitoring data of $2002{\sim}2005$. The model efficiency of runoff ranged from good to fair in comparison between simulated and observed data, while it was from very good to poor in the water quality parameters. But its reliability and performance were within the expectation considering complexity of the watershed and pollutant sources. The nonpoint source (NPS) loading for T-N and T-P during the monsoon rainy season (June to September) was about 80% of total NPS loading, and runoff volume was also in a similar range. However, NPS loading for BOD ($55{\sim}60%$) didn't depend on rainfall because BOD was mostly discharged from point source (more than 70%). And water quality was not necessarily high during the rainy season, and showed a decreasing trend with increasing water flow. BASINS/HSPF was applied to the Hwaseong watershed successfully without difficulty, and it was found that the model could be used conveniently to assess watershed characteristics and to estimate pollutant loading including point and nonpoint sources in watershed scale.

영산호의 부영양화방지를 위한 질소, 인의 배출원단위에 관한 조사연구 (Unit Loading Factor of Nitrogen and Phosphorus for Controlling Eutrophication of Youngsan Lake)

  • 류일광;이치영;강영식;김관천
    • 한국환경보건학회지
    • /
    • 제15권2호
    • /
    • pp.51-58
    • /
    • 1989
  • In order to estimate unit loading factors of N, and P for controlling eutrophication of Youngsan lake. This study was performed in 4 kinds of pollutant sources from domestic sewage, industrial waste water, livestock stall waste water and drainage of agricultural area during the period from april to october 1988. These results were as follows: 1. The sewage flow for domestic waste water was 191.2 l/capita, day and that of the gray and toilet waste water among the domestic waste water were shown 152.9 l/capita, day(80%) and 38.3 l/capita, day(20%), respectively. 2. The unit loading factor total nitrogen(T-N) for domestic waste water was 7.582g/capita, day, and that of the gray and toilet waste water among the domestic waste water were 1.826g/ capita, day(24.1%) and 5.756g/capita, day(75.9%), respectively. The other hand, the unit loading factors of total phosphorus(T-P) for domestic waste water was 0.925g/capita, day, and that of gray and toilet waste water among the domestic waste water were 0.470g/capita, day(50.8%) and 0.455g/capita, day(49.2%), respectively. 3. In offering Price per million won, the T-P loading factor for drinking manufacture, confectionery manufacture, beer-manufacture and fibre manufacture in the industrial pollutant sources estimate to be 0.350g/day, 0.099g/day, 32.351g/day and 1.536g/day, while T-N loading factor about them in the industrial pollutant sources estimate to be 4.117g/day, 2.414g/day, 106.726g/day and 60.504g/day, respectively. 4. The T-P loading factor according to wash-water of milch cow and pig were 6.735g/day and 18.526g/day, in case of T-N they were 42.397g/day and 27.226g/day, respectively. 5. The T-P loading factor for pollutants drainage in the Paddy fields, fields and forests area were 0.082g/are, day, 0.014g/are, day and 0.002g/are, day, and the T-N loading factor were 0.309g/are, day, 0.158g/are, day and 0.064g/are, day, respectively. The diffrent of the loading factor for pollutants discharges in the agricultural area were resulted from the rainful intensity, the rainful, the amount of fertilization manure, and etc.

  • PDF