• Title/Summary/Keyword: Pollutant detection

Search Result 47, Processing Time 0.024 seconds

Preprocessing Methods and Analysis of Grid Size for Watershed Extraction (유역경계 추출을 위한 DEM별 전처리 방법과 격자크기 분석)

  • Kim, Dong-Moon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.26 no.1
    • /
    • pp.41-50
    • /
    • 2008
  • Recent progress in state-of-the-art geospatial information technologies such as digital mapping, LiDAR(Light Detection And Ranging), and high-resolution satellite imagery provides various data sources fer Digital Elevation Model(DEM). DEMs are major source to extract elements of the hydrological terrain property that are necessary for efficient watershed management. Especially, watersheds extracted from DEM are important geospatial database to identify physical boundaries that are utilized in water resource management plan including water environmental survey, pollutant investigation, polluted/wasteload/pollution load allocation estimation, and water quality modeling. Most of the previous studies related with watershed extraction using DEM are mainly focused on the hydrological elements analysis and preprocessing without considering grid size of the DEMs. This study aims to analyze accuracy of the watersheds extracted from DEMs with various grid sizes generated by LiDAR data and digital map, and appropriate preprocessing methods.

Complexity of Groundwater Flow System in a Site Reflected in the Fluctuations of Groundwater Level and Temperature (지하수위와 수온 변동에 나타난 부지 규모 지하수 흐름장의 복잡성)

  • Jonghoon Park;Dongyeop Lee;Nam C. Woo
    • Economic and Environmental Geology
    • /
    • v.55 no.6
    • /
    • pp.563-570
    • /
    • 2022
  • This study was objected to show the complexity of groundwater flow system in a site-scale area as a design parameter of the groundwater monitoring network for early detection of pollutant leakage from a potential source of groundwater contamination (e.g., storage tank). Around the tanks, three monitoring wells were installed at about 22~25 m deep and groundwater level and temperature had been monitored for 22 months by 2-minute interval, and then compared with precipitation and temperature data from nearby weather station. Annual variation of groundwater level and its response to precipitation event, variation of groundwater temperature and delayed response to that of atmospheric temperature indicate the complexity of groundwater flow and flow paths even in the relatively small area. Thus, groundwater monitoring network for early detection of contaminant leakage should be designed with full consideration of the complexity of groundwater flow system, identified from the detailed hydrogeological investigation of the site.

Determination of Organic Pollutants in Dyeing Wastewater (염색폐수 중의 유기오염물질 분석)

  • Yook, Keun-Sung
    • Analytical Science and Technology
    • /
    • v.10 no.5
    • /
    • pp.332-342
    • /
    • 1997
  • Fifteen volatile organic pollutants were spiked in blank water at the concentration of $20{\mu}g/L$ and analyzed with Purge and Trap and GC/MS. As a result, the overall mean recovery of 100% was obtained with a mean relative standard deviation of 3.6%. The method detection limits were in the range of $1.9{\sim}3.3{\mu}g/L$. In the wastewater analysis of Banwol dyeing comlex, 15 organic compounds were identified and three of these were quantified. Among the compounds identified, only trichloroethylene and tetrachloroethylene are regulated in wastewater by the Korea Ministry of Environment. But, the concentration of these two compounds were below the government allowance level.

  • PDF

Trace Organic Contaminants in Sediments from Deep-sea Basin near Dokdo, Korea

  • Yim, Un-Hyuk;Oh, Jae-Ryoung;Hong, Sang-Hee;Li, Dong-Hao;Shim, Won-Joon;Choi, Hye-Kyung;Kim, Eun-Soo;Shim, Jae-Hyung
    • Ocean and Polar Research
    • /
    • v.24 no.4
    • /
    • pp.391-398
    • /
    • 2002
  • Trace organic contaminants in deep-sea sediments near Dokdo were analyzed. Total PAMs concentration ranged 14.8-314 ng/g dry weight and high molecular weight PAHs were dominant. The highest PAHs concentration was detected at A19 which located at Ulleung Basin. Most of organochlorines were under detection limit. Among the detected organochlorines, DDT compounds were dominant and followed by HCHs and HCB. Butyltin compounds and most of organophosphorus pesticides were not detected. Vertical distribution of PAHs showed typical sub-surface maximum and decreasing trends depending on depth. The highest PAHs concentration reached 454ng/g. Some organochlorines, DDT, HCH was detected and also showed decreasing trends. Other target organic pollutants were not detected in core sediments. Abnormally high level of PAHs concentration in A19 was discussed and the input sources were inferred to be the transport of sludge derived pollutant dumped at dumping site 'Byung' by deep current.

CO Two-photon Laser Induced Fluorescence Measurements in High Temperature and Pressure Conditions (고온고압 조건에서 Two-Photon LIF를 이용한 CO 측정에 관한 연구)

  • Oh, Seung-Mook;Kim, Duk-Sang;Miles, Paul C.;Colban, Will F.
    • Journal of the Korean Society of Combustion
    • /
    • v.12 no.4
    • /
    • pp.1-7
    • /
    • 2007
  • Carbon monoxide (CO) is not only an important intermediate species in chemical reaction mechanisms of hydrocarbon fuel combustion, but also a crucial pollutant species emitted from automotive engines. To better understand the physical processes impacting CO emissions, the development of laser-based measurement techniques that can visualize in-cylinder CO distributions is desirable. Among these techniques, Laser-Induced Fluorescence (LIF) is a sensitive and species-selective detection technique capable of good spatial resolution. However, some technical matters such as deep UV excitation, severe pressure dependency of the LIF signal, and potential interference from other species have been major challenges for CO LIF application. This study is focused on investigating the feasibility of CO two-photon LIF in a direct-injection diesel engine operating at typical pressure and temperature conditions with commercial grade diesel fuel. Spectroscopic analysis shows that the CO fluorescence signal can be separated from $C_2$ Swan band or broadband fluorescence from PAHs when the signal is collected near 483 nm. The signal-to-noise ratio of CO LIF deteriorate rapidly as pressure is increased, following $P^{-1.49}$ which matches the theoretical signal pressure dependency.

  • PDF

Characteristics of Ozone Advection in Vertical Observation Analysis Around Complex Coastal Area (연직관측자료를 통한 복잡 연안지역의 오존 이류특성)

  • Lee, Hwa-Woon;Park, Soon-Young;Lee, Soon-Hwan;Leem, Heon-Ho
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.1
    • /
    • pp.57-74
    • /
    • 2009
  • In order to clarify the vertical ozone distribution in planetary boundary layer of coastal area with complex terrain, an observation campaign was carried out around Gwangyang Bay with dense pollutant emission sources during two days from June, 4 2007. For this observation are Radiosonde, SODAR(SOnic Detection And Ranging) and Tethered ozone sonde were employed. The surface meteorological and photochemical observation data provided by AWS (Automatic Weather System) and AQMS (Air Quality Monitoring System) were also applied for analysis. Synoptic condition is strongly associated with lower level ozone distribution in complex terrain coastal area. Since mesoscale circulation induced by difference of characteristics of land and sea and orographic forcing is predominant under calm synoptic condition, vertical distribution of ozone is complicate and vertical ozone concentration greatly fluctuated. However in second day when synoptic influence become strong, ozone concentration in lower levels is vertically uniform regardless of observation level. This results in vertical observation indicates that vertical ozone distribution is often determined by synoptic condition and also affects surface ozone concentration.

Application of Discrete Wavelet Transform for Detection of Long- and Short-Term Components in Real-Time TOC Data (실시간 TOC 자료의 장.단기 성분의 검출을 위한 이산형 웨이블렛 변환의 적용)

  • Jin, Young-Hoon;Park, Sung-Chun
    • Journal of Environmental Science International
    • /
    • v.15 no.9
    • /
    • pp.865-870
    • /
    • 2006
  • Recently, Total Organic Carbon (TOC) which can be measured instantly can be used as an organic pollutant index instead of BOD or COD due to the diversity of pollutants and non-degradable problem. The primary purpose of the present study is to reveal the properties of time series data for TOC which have been measured by real-time monitoring in Juam Lake and, in particularly, to understand the long- and short-term characteristics with the extraction of the respective components based on the different return periods. For the purpose, we proposed Discrete Wavelet Transform (DWT) as the methodology. The results from the DWT showed that the different components according to the respective periodicities could be extracted from the time series data for TOC and the variation of each component with respect to time could emerge from the return periods and the respective energy ratios of the decomposed components against the raw data.

A Mathematical Model Proposed for the Prediction of the Fate of Priority Organic Pollutants Spilled in Streams: Dynamic Simulations and Sensitivity Analysis (하천에 유입된 유독성 유기오염물의 농도분포를 예측하기 위한 수학적 모형의 개발: Dynamic simulations 및 민감도 분석)

  • Ko, Kwang Baik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.2
    • /
    • pp.265-274
    • /
    • 1992
  • A mathematical model was proposed to predict the fate of a priority organic pollutant, anthracene, accidently spilled into a stream. The model consists of 6 differential equations with 5 input variables and 9 rate constants. Volatilization, biodegradation, adsorption/desorption, photodegradation as well as the convective inputs and outputs are included in the model. As a result of a series of dynamic simulations and sensitivity analyses under the given conditions, the concentrations of the organic chemical could be predicted within a detection limit in the stream. It was also suggested that the rate constant for diffusion/transport and adsorption rate constant are the most influential ones for predicting the chemical conentrations in dissolved and particulate phase. The model proposed appears to be a useful tool for assessing chemical spills.

  • PDF

Methods of Knock Signal Analysis in a S.I. Engine (4 기통 스파크 점화 기관의 노킹 신호 해석 방법)

  • Kim, K.W.;Chun, K.M.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.1 no.3
    • /
    • pp.12-21
    • /
    • 1993
  • In recent years, high efficiency, high performance, and low pollutant emmision engines have been developed. Knock phenomenon has drawn interests because it became an hinderance to engine power and efficiency increase through higher compression ratio. Knock phenomenon is an abnormal combustion originated from autoignition of unburned gas in the end-gas region during the later stage of combustion process and accompanied a high pitched metallic noise. And this phenomenon is characterized by knock occurrence percentage, knock occurrence angle and knock intensity. A four cylinder spark ignition engine is used in our experiment, and its combustion chamber pressure is measured at various engine speeds, ignition timing. The data are analyzed by numerous methods in order to select the optimum methods and to achieve better understanding of knock characteristics. Methods using band-pass filter, third derivative and step method are shown to be the most suitable, while methods using frequency analysis are shown to be unsuitable. Because step method only uses signals above threshold value during knocking condition, pressure signal analyses with this method show good signal-to-noise ratio.

  • PDF

Comparison of Liquid-Liquid Extraction and Solid-Phase Extraction Coupled with GC/MS for Determination of Priority Pollutants in Water (액체 추출법과 고체상 추출법에 의한 수질 중 유해물질 농축법 비교)

  • Yook, Keun-Sung;Hong, Sa-Moon;Kim, Jong-Ho
    • Analytical Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.441-453
    • /
    • 1994
  • Two extraction methods, liquid-liquid extraction(LLE) and solid-phase extraction(SPE), coupled with GC/MS were compared as preconcentration procedures for priority pollutants in water. Among the semi-volatile priority pollutants, 11 acid and 44 base/neutral compounds were spiked in reagent water. With LLE, which is a modification of EPA Method 625, the overall mean recovery of the 54 compounds was 91% with a mean relative standard deviation(RSD) of 4.6%. With SPE, the overall mean recovery of the 52 compounds was 53% with a mean RSD of 8.9%. The detection limits of both methods were in the range of $1{\sim}5{\mu}g/l$.

  • PDF