• Title/Summary/Keyword: Pollutant Emission

Search Result 462, Processing Time 0.026 seconds

The Pollutant Emissions Characteristics of Lean-Rich Combustion System with Exhaust Gas Reciculation (EGR 시스템을 적용한 린-리치 연소시스템의 공해물질 배출 특성 연구)

  • Oh, Wheesung;Yu, Byeonghun;Kim, Jong-Hyun;Lee, Chang-Eon
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.233-234
    • /
    • 2014
  • Lean-rich combustion system was composed both fuel-lean and fuel-rich flame at once. Each of fuel-lean and fuel-rich combustion types to reduce Thermal $NO_x$ and obtain flame stability. This study was confirmed a stability of flame through variation of flame shape that EGR was applied and compared the emission characteristics of EGR lean-rich combustion system to normal premixed combustion system at real condition to review a utility of the system. As a result, emission index of $NO_x$ and CO generated from EGR lean-rich combustion system at global equivalence ratio is 0.85 just half level($NO_x$ 0.31 g/kg, CO 0.08g/kg) compared to the amount generated from normal premixed combustion system at equivalence ratio is 0.78.

  • PDF

A Fuzzy Model Based on the PNN Structure

  • Sang, Rok-Soo;Oh, Sung-Kwun;Ahn, Tae-Chon;Hur, Kul
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1998.06a
    • /
    • pp.83-86
    • /
    • 1998
  • In this paper, a fuzzy model based on the Polynomial Neural Network(PNN) structure is proposed to estimate the emission pattern for air pollutant in power plants. the new algorithm uses PNN algorithm based on Group Mehtod of Data Handling (GMDH) algorithm and fuzzy reasoning in order to identify the premise structure and parameter of fuzzy implications rules, and the least square method in order to identify the optimal consequence parameters. Both time series data for the gas furnace and data for the NOx emission process of gas turbine power plants are used for the purpose of evaluating the performance of the fuzzy model. The simulation results show that the proposed technique can produce the optimal fuzzy model with higher accuracy and feasibility than other works achieved previously.

  • PDF

Combustion and Emission Characteristics of Diesel Spray in High-Pressure Environment (고압상태에서의 디젤연료분무의 연소 및 매연가스배출 특성)

  • Kwon, Y.D.;Kim, Y.M.;Kim, S.W.;Park, S.B.
    • Journal of ILASS-Korea
    • /
    • v.2 no.1
    • /
    • pp.18-28
    • /
    • 1997
  • The present study is mainly aiming at numerically analyzing the combustion and emission characteristics of the diesel spray in a high-pressure environment. Computations are peformed for the peak chamber pressure with range from 4.08 MPa to 162 MPa. Numerical results indicate that the pressure increase in combustion chamber significantly influences the mechanism for droplet dynamics and mixing characteristics, spray penetration autoignition, flame lift-on height and the propagation or fuel vapor and flame. By increasing the ratio or the ambient density to injected liquid density, the fuel-air mixing rates and the burning rates increase and the $NO_x/soot$ emission level decreases.

  • PDF

Use of Geographic Information System Tools for Improving Mobile Source Atrmospheric Emission Inventories

  • Shin, Tae-joo
    • Environmental Sciences Bulletin of The Korean Environmental Sciences Society
    • /
    • v.3 no.3
    • /
    • pp.143-150
    • /
    • 1999
  • Mobile source emissions are important inputs to photochemical air quality models. Since most mobile source emissions are calculated at the county-level, these emission should be geographically allocated to the computational grid cells of a photochemical air quality model prior to running the model. The traditional method for the spatial allocation of these emissions has been to use a "spatial surrogate indicator" such as population, since grid-specific emission calculations are very labor-intensive and expensive, plus the necessary data are often not available for such grid resolutions. Accordingly, new spatial surrogate indicators for mobile source emissions(specifically for highway emissions) were developed using Geographic Information Systems(GIS) tools due to the spatially variable nature of mobile source emissions. These newly developed spatial surrogate indicators appear to be more appropriate for the allocation of highway emissions than the population surrogate indicator. It was also revealed that the conventional spatial allocation method underestimates the maximum levels of air pollutant emmissions.mmissions.

  • PDF

The Estimation of Harmful Air Pollutant Emission from Landfill Site - A Subject of Sulfide Compounds - (쓰레기매립장에서의 유해대기오염물질 배출특성에 관한 연구 - 황화합물을 대상으로-)

  • 노기환;전의찬
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.1
    • /
    • pp.47-52
    • /
    • 2001
  • In this study, we focused on typically problematic sulfide compounds Gas samples were captured at Unjung-ding landfill site in Metropolitan Kwangju with flux chamber and floating chamber, and analyzed for the amount of hydrogen sulfide($H_2S$), dimethyl sulfide $((CH_3)_2S)$ and dimethyl disulfide$((CH_3)_2S_2)$. From the gas pipe, landfill surface and leachate treatment plant, estimated total amount of $H_2S$ emission are 12.6ton/yr, 0.01ton/yr and 1.04ton/yr; estimated total amount of $((CH_3)_2S)$ 30.7ton/yr, 0.08ton/yr and 1.72ton/yr; and estimated total amount of ($((CH_3)_2S_2)$ 2.2tom/yr, 0.02ton/yr and 1.03ton/yr, respectively. Further in-depth study on co-relation between age, packing characteristics, temperature and humidity of landfill site and gas emission characteristics is needed.

  • PDF

An Emission Estimation of Pollutants Including Ship Sources in the Pusan Metropolitan Area (연안의 선박오염배울을 포함한 부산지역의 대기오염물질 배출량 산정)

  • 이화운;김유근;원경미;조인숙
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.5
    • /
    • pp.587-598
    • /
    • 1999
  • In recent years emissions of pollutants from ship sources, especially NOx and SOx, is controlled by IMO(International Maritime Organization). The emissions of pollutants from ship sources in Pusan is considerably large, because the number of ship's coming and going in Pusan port is larger than that of other ports in Korea. Since Pusan is under the strong influence of land-sea breezes, pollutants emitted from ship sources will be transported into the inland. Control of emissions from ship sources is required to devise effectively the policy of air quality management in Pusan. Therefore this paper considered the present condition of total pollutant sources and emission characteristics including in coastal urban area.

  • PDF

Availability Analysis on Detection of Small Scale Gas Emission Facilities using Drone Imagery (드론영상을 이용한 소규모 가스 배출시설 탐지 가능성 분석)

  • Shin, Jung-Il;Kim, Ik-Jae;Hwang, Dong-Hyun;Lee, Jong-Min;Lim, Seong-Ha
    • Journal of Cadastre & Land InformatiX
    • /
    • v.47 no.1
    • /
    • pp.213-223
    • /
    • 2017
  • Recently, the air quality of South Korea has deteriorated and public interest has been increasing. Various observation means are used for the monitoring of the atmospheric environment, but it relies on the experience and judgment of the observer in the absence of spatial information on the emission facilities. The purpose of this study was to determine the availability of using drones for monitoring air pollutant emission facilities. A texture transformation method was applied to the drone ortho image to detect the small gas emission facility and the slope data calculated by the digital surface model (DSM) was used to reduce the false alarm ratio. As a result, it shows the possibility of using drones in the detection of small gas emission facilities by showing about 80% of positive detection ratio and 40% of false alarm ratio. In the future, various researches are required to the improve positive detection ratio and the reduction of the false alarm ratio. Based on these results, it is necessary to construct a database including 3D spatial information of air pollutant emission facilities.

Characteristics of Hazardous Air Pollutant Emissions from Waste Incinerators (폐기물소각시설의 유해대기오염물질 배출특성 연구)

  • Park, J.M.;Lee, S.B.;Kang, J.G.;Kim, J.P.;Choi, E.S.;Hwang, W.G.;Kwon, O.S.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.2
    • /
    • pp.183-190
    • /
    • 2007
  • In this study, we have investigated waste incinerators which are one of the major HAPs emission sources. In order to obtain more reliable HAPs emission data from waste incinerators, direct sampling for the possible pollutants from the stack was carried out and the analysis was performed. The purpose of study was to understand the emission status from waste incinerators and recognize the problems and finally to set up a strategy to reduce the HAPs emissions from waste incinerators. The emission concentrations of 8 species of heavy metals and 16 species of PAHs have been analyzed for the first time in Korea. Not only the emission characteristics of HAPs from waste incinerators were identified, but also the analysis of reduction efficiencies for control devices such as BF and wet scrubbing systems was carried out.

Measuring Particle Number from Light-duty Diesel Vehicles in WLTP Driving Cycle (WLTP 주행모드에서의 경유차 입자상물질 개수 배출 특성)

  • Park, Junhong;Lee, Jongtae;Kim, Jeongsoo;Kim, Sunmoon;Ahn, Keunhwan
    • Journal of ILASS-Korea
    • /
    • v.18 no.3
    • /
    • pp.155-160
    • /
    • 2013
  • Worldwide harmonized light-duty vehicle test procedure (WLTP) for emission certification has been developed in WP.29 forum in UN ECE since 2007. The test procedure is expected to be applied to Korean light-duty diesel vehicles at the same time of adoption in Europe. The air pollutant emissions from light-duty vehicles have been regulated with weight per distance travelled which means the driving cycles can affect the results. The six Euro-5 light-duty diesel vehicles including sedan, SUV and truck have been tested with WLTP, NEDC which is used for emission certification for light-duty diesel vehicles, and CVS-75 to estimate how much particle number emission can be affected by different driving cycles. The averaged particle number emissions have not shown statistically meaningful difference. The maximum particle number emission have been found in Low speed phase of WLTP which is mainly caused by cooled engine conditions. The amount of particle number emission in cooled engine condition is much different as test vehicles. It means different technical solution is required in this aspect to cope with WLTP driving cycle.

The Estimation and Application of Optimum Design Variables for Road Tunnel Ventilation System Based on Statistical Analysis (통계적 분석을 이용한 터널 환기시스템 적정설계변수의 산정 및 적용에 관한 연구)

  • 이보영;유용호;김진
    • Tunnel and Underground Space
    • /
    • v.14 no.5
    • /
    • pp.373-380
    • /
    • 2004
  • In this study, the emission rate of pollutant was modified according to the published standards, and the distribution of pollutant concentration was analyzed for each vehicle velocity. This modified emission rate was applied to a model tunnel and it was proved that the required air quantity was reduced to 49%, compared to the PIARC method. From the simulation result, it was proved by using statistics that the most sensitive factor among them is the friction coefficient and it was modified to the value in the range of 0.018 to 0.021. It is also expected that the required air quantity can be decreased form 14.4% to 19.2% according as the coefficient is applied to the domestic model tunnels. In conclusion, it is proposed that the number of jet fans can be reduced and the annual operating cost can be curtailed as well.