• Title/Summary/Keyword: Polishing instrument

Search Result 17, Processing Time 0.023 seconds

SURFACE ROUGHNESS OF COMPOSITE RESIN ACCORDING TO FINISHING METHODS (복합레진 표면의 연마방법에 따른 표면조도)

  • Min, Jeong-Bum;Cho, Kong-Chul;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.2
    • /
    • pp.138-150
    • /
    • 2007
  • The purpose of this study was to evaluate the difference of surface roughness of composite resin according to composite resin type, polishing methods, and use of resin sealant. Two hundred rectangular specimens, sized $8{\times}3{\times}2mm$, were made of Micro-new (Bisco, Inc., Schaumburg, IL, U.S.A) and Filtek Supreme (3M ESPE Dental Products, St. Paul, MN, U.S.A.), and divided into two groups; Micronew-M group, Filtek Supreme-S group. Specimens for each composite group were subdivided into five groups by finishing and polishing instruments used; M1 & S1(polyester strip), M2 & S2 (Sof-Lex disc), M3 & S3 (Enhance disc and polishing paste), M4 & S4(Astropol) and M5 & S5 (finishing bur), Polished groups were added letter B after the application of resin surface sealant (Biscover), eg, M1B and S1B. After specimens were stored with distilled water for 24hr, average surface roughness (Ra) was taken using a surface roughness tester. Representative specimens of each group were examined by FE-SEM (S-4700: Hitachi High Technologies Co., Tokyo, Japan). The data were analysed using paired t-test, ANOVA and Duncan's tests at the 0.05 probability level. The results of this study were as follows ; 1. The lowest Ra was achieved in all groups using polyester strip and the highest Ra was achieved in M5, S5 and M5B groups using finishing bur. On FE-SEM, M1 and S1 groups provided the smoothest surfaces, M5 and S5 groups were presented the roughest surfaces and voids by debonding of filler on the polished specimens. 2. There was no significant difference in Ra between Micronew and Filtek Supreme before the application of resin sealant, but Micronew was smoother than Filek Supreme after the application of resin sealant. 3. There was significant corelation between Ra of type of composite resin and polishing methods before the application of resin sealant (p=0.000), but no significant interaction between them after the application of resin sealant. On FE-SEM, most of composite resin surfaces were smooth after the application of resin sealant on the polished specimens. 4. Compared with before and after the application of resin sealant in group treated in the same composite and polishing methods, Ra of M4B and M5B was statistically lower than that of M4 and M5, and S5B was lower than that of S5, respectively (p<0.05). In conclusion, surface roughness by polishing instruments was different according to type of composite resin. Overall, polyester strip produced the smoothest surface, but finishing bur produced the roughest surface. Application of resin sealant provided the smooth surfaces in specimens polished with Enhance, Astropol and finishing bur, but not provided them in specimens polished with Sof-Lex disc.

Vibration Suppression Design on the Instrument Supporting Structure for the Optical Performance Measurement (대구경 반사경 광학성능 측정을 위한 간섭계 지지구조물의 진동저감 설계)

  • Kim, Hong-Bae;Lim, Jong-Min;Yang, Ho-Soon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.205-208
    • /
    • 2005
  • Fabrication of large scaled mirror for the telescope application is the most challenging technology in recent year. Sophisticate technologies and know-how in fabrication and measurement are required to overcome the technological obstacles. KRISS(Korea Research Institute for Standards and Science) is now developing a large scaled mirror fabrication facility and KARI(Korea Aerospace Research Institute) is supporting the development. High precision interferometric test is required during the grinding and polishing of mirror to identify the surface profile precisely. The required fabrication accuracy of the mirror surface profile is $\lambda$/50 ms($\sim$10 nm for visible wave length). Thus the measurement accuracy should be far less than 10 m. To get this requirement, it is necessary to provide vibration free environment for the interferometer system and mirror under test. Thus the vibration responses on the mirror supporting table due to external vibration should be minimized by using a special isolation system. And the responses on the top of the tower, which hold the interferometer during test, should be minimized simultaneously. In this paper, we propose the concept design of vibration suppression system for the KRISS mirror fabrication facility.

  • PDF

1.6 M SOLAR TELESCOPE IN BIG BEAR - THE NST

  • GOODE PHILIP R.;DENKER CARSTEN.J.;DIDKOVSKY LEONID I.;KUHN J. R.;WANG HAIMIN
    • Journal of The Korean Astronomical Society
    • /
    • v.36 no.spc1
    • /
    • pp.125-133
    • /
    • 2003
  • New Jersey Institute of Technology (NJIT), in collaboration with the University of Hawaii (UH), is upgrading Big Bear Solar Observatory (BBSO) by replacing its principal, 65 cm aperture telescope with a modern, off-axis 1.6 m clear aperture instrument from a 1.7 m blank. The new telescope offers a significant incremental improvement in ground-based infrared and high angular resolution capabilities, and enhances our continuing program to understand photospheric magneto-convection and chromospheric dynamics. These are the drivers for what is broadly called space weather - an important problem, which impacts human technologies and life on earth. This New Solar Telescope (NST) will use the existing BBSO pedestal, pier and observatory building, which will be modified to accept the larger open telescope structure. It will be operated together with our 10 inch (for larger field-of-view vector magnetograms, Ca II K and Ha observations) and Singer-Link (full disk H$\alpha$, Ca II K and white light) synoptic telescopes. The NST optical and software control design will be similar to the existing SOLARC (UH) and the planned Advanced Technology Solar Telescope (ATST) facility led by the National Solar Observatory (NSO) - all three are off-axis designs. The NST will be available to guest observers and will continue BBSO's open data policy. The polishing of the primary will be done in partnership with the University of Arizona Mirror Lab, where their proof-of-concept for figuring 8 m pieces of 20 m nighttime telescopes will be the NST's primary mirror. We plan for the NST's first light in late 2005. This new telescope will be the largest aperture solar telescope, and the largest aperture off-axis telescope, located in one of the best observing sites. It will enable new, cutting edge science. The scientific results will be extremely important to space weather and global climate change research.

Effects of various CLEAN-UP techniques on enamel surface roughness (수종의 CLEAN-UP technique이 법랑질 표면거칠기에 미치는 영향)

  • CHO, Sang-Wan;KWON, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.27 no.5 s.64
    • /
    • pp.791-800
    • /
    • 1997
  • Sixty premolars extracted for orthodontic treatment were divided into four groups, and the residual resin was removed with four different rotary finishing instruments at a fixed speed of $18,500{\pm}300 rpm$ on the low speed handpiece. The instruments were G1; No.169L carbide fissure bur, G2: No.2 round bur, G3; No.4 round bur, G4: No.8 round bur. Then, the enamel received a S-second polishing with a rubber cup and a pumice. To find the extent of loss on the enamel at this point, prophylaxis was done with the rubber cup and pumice prior to bonding of the bracket(P1) and removal of residual resin by means of appropriate procedure applicable to each respective group(P2) followed. The final polishing was done with the rubber cup and pumice(P3), and the enamel surface roughness was measured each by the surface measuring instrument. The whole process was observed under a scanning electron microscope to gain the following results: At P2, the enamel surface roughness in G1 showed most smoothly with $2.60{\pm}0.55{\mu}m;\;in\;G2,\;3.24{\pm}0.80{\mu}m;\;in\;G3,\;3.44{\pm}0.94{\mu}m;\;in\;G4,\;3.89{\pm}0.54{\mu}m$, the roughest. G2 and G3 showed no statistical significance(P>0.05). At P3, the enamel surface roughness in G1 showed most smoothly with $2.29{\pm}0.47{\mu}m;\;in\;G2,\;2.44{\pm}0.56{\mu}m;\;in\;G3,\;2.44{\pm}0.56{\mu}m;\;in\;G4,\;2.92{\pm}0.43{\mu}m$, the roughest. G1 vs G2, G3, and G2 vs G3 had no statistical significances(p>0.05). In all groups, P2 and P3 showed rougher in surface roughness than P1, and P2 rougher than P3(p<0.01). In a case of 5-second prophylaxis with the rubber cup and the pumice on a virgin, normal enamel, fine scratches were found under the scanning electron microscope. In all four groups, unremovable gouges remained even after polishing with the ubber and pumice; residual resin was not observed with naked eye when finished with the rubber and pumice, but the resin debris was observed under the scanning electron microscope.

  • PDF

A Comparative study of roughness of enamel surface to various interdental enamel stripping methods in vitro (치간 법랑질 삭제방법에 따른 치아표면 거칠기에 관한 비교연구)

  • Row, Joon;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.29 no.4 s.75
    • /
    • pp.483-490
    • /
    • 1999
  • Interdental enamel stripping is an usual method for correction of abnormal tooth shape and tooth size discrepancy which is one of the etiologic factors of malocclusion. Clinically it Is useful to correct the minor crowding in anterior teeth and posterior occlusion during finishing stage of orthodontic treatment. But this procedure has risks such as irreversible tooth reduction and remaining roughness of enamel surface can accumulate plaque which can evoke periodontal problem. Even if various methods were introduced to minimize the enamel surface roughness, their evaluation was limited in morphologic differences by scanning electronic microscope(SEM). The purpose of this study was to compare the various interdental enamel stripping method by SEM and to quantify the difference of surface roughness by use of Surfcorder SEF-30D(Kosaka Lab. Ltd.) which can measure the roughness of surface. The stripping methods were divided into mechanical and mechanical-chemical method. Air-rotor stripping and separating strip were used for mechanical stripping and $37\%$ phosphoric acid was used for chemical stripping. The enamel surface roughness after mechanical or mechanical-chemical stripping of interproximal surfaces of premolars which were extracted for orthodontic purpose were measured and compared by means of SEM and $Surfcorder^{\circledR}$, the results were as follows. 1. Enamel surface of primary treated by coarse diamond bur and separating strip groups showed highest value of roughness. 2. To compare the primary treated groups between mechanical and mechanical-chemical method, the latter group showed lower value of roughness remarkably. 3. Mechanical stripping groups which were treated both coarse and fine instrument showed lower value of roughness as much as non treated group. 4. The use of Pumice for final polishing did not show significantly smoothening the stripped enamel surface any more.

  • PDF

EVALUATION ON THE ABRASION RESISTANCE OF A SURFACE SEALANT (레진전색제의 마모저항성에 대한 평가)

  • Kim, Soo-Mee;Han, Sae-Hee;Cho, Young-Gon
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.3
    • /
    • pp.180-190
    • /
    • 2007
  • The purpose of this study was to evaluate the abrasion resistance of surface penetrating sealant which was applied on a composite resin restoration and to provide proper time to reapply sealant on composite resin surface. Two hundred rectangular specimens, sized $8\times3\times2mm$, were made of Micronew (Bisco, Inc., Schaumburg, IL, U.S.A) and divided into two groups; F group (n = 10) was finished with coarse and medium grit of Sof-Lex discs and BisCoverwas applied B group (n = 190) after finishing with discs. B group was again subdivided into nineteen subgroups From B-1 group to B-18 group were subjected to toothbrush abrasion test using a distilled water-dentifrice slurry and toothbrush heads B-IM group was not subjected to toothbrush abrasion test. Average surface roughness (Ra) of each group was calculated using a surface roughness tester (Surfcorder MSE-1700: Kosaka Laboratory Ltd., Tokyo, Japan) . A representative specimen of each group was examined by FE-SEM (S-4700: Hitachi High Technologies Co., Tokyo, Japan). The data were analysed using cluster analysis, paired t-test, and repeated measure ANOVA. The results of this study were as follows; 1. Ra off group was $0.898{\pm}0.145{\mu}m$ and B-IM group was $0.289{\pm}0.142{\mu}m$. Ra became higher from B-1 group $(0.299{\pm}0.48{\mu}m$ to B-18 group $(0.642{\pm}0.313{\mu}m$. 2. Final cluster center of Ra was $0.361{\mu}m$ in cluster 1 $(B-IM\simB-7)$, $0.511{\mu}m$ in cluster 2 $(B-8\simB-14)$ and $0.624{\mu}m$ in cluster 3 ($(B-15\simB-18)$. There were significant difference among Ra of three clusters. 3 Ra of B-IM group was decreased 210.72% than Ra of F group. Ra of B-8 group and B-15 group was increased 35.49% and 51.35% respectively than Ra of B-IM group. 4. On FE-SEM, B-IM group showed the smoothest resin surface. B-8 group and B-15 group showed vertically shallow scratches , and wide and irregular vertical scratches on composite resin surface respectively. Within a limitation of this study, finished resin surface will be again smooth and glazy if BisCover would be reapplied within 8 to 14 months after applying to resin surface.

EVALUATING THE RELIABILITY AND REPEATABILITY OF THE DIGITAL COLOR ANALYSIS SYSTEM FOR DENTISTRY (치과용 디지털 색상 분석용 기기의 정확성과 재현 능력에 대한 평가)

  • Jeong, Joong-Jae;Park, Su-Jung;Cho, Hyun-Gu;Hwang, Yun-Chan;Oh, Won-Mann;Hwang, In-Nam
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.352-368
    • /
    • 2008
  • This study was done to evaluate the reliability of the digital color analysis system (ShadeScan, CYNOVAD, Montreal. Canada) for dentistry. Sixteen tooth models were made by injecting the A2 shade chemical cured resin for temporary crown into the impression acquired from 16 adults. Surfaces of the model teeth were polished with resin polishing cloth. The window of the ShadeScan handpiece was placed on the labial surface of tooth and tooth images were captured, and each tooth shade was analyzed with the ShadeScan software. Captured images were selected in groups, and compared one another. Two models were selected to evaluate repeatability of ShadeScan, and shade analysis was performed 10 times for each tooth. And, to ascertain the color difference of same shade code analyzed by ShadeScan, CIE $L^*a^*b^*$values of shade guide of Gradia Direct (GC, Tokyo, Japan) were measured on the white and black background using the Spectrolino (GretagMacbeth, USA), and Shade map of each shade guide was captured using the ShadeScan. There were no teeth that were analyzed as A2 shade and unique shade. And shade mapping analyses of the same tooth revealed similar shade and distribution except incisal third. Color difference (${\Delta}E^*$) among the Shade map which analyzed as same shade by ShadeScan were above 3. Within the limits of this study, digital color analysis instrument for dentistry has relatively high repeatability, but has controversial in accuracy.