• Title/Summary/Keyword: Polarity effect

Search Result 281, Processing Time 0.024 seconds

Weldability Increase of Aluminum by Variable Polarity Arc (가변 극성 아크의 알루미늄 용접성 향상에 관한 연구)

  • Cho, Jungho
    • Journal of Welding and Joining
    • /
    • v.32 no.1
    • /
    • pp.108-111
    • /
    • 2014
  • Low arc weldability of aluminum alloy is enhanced by applying variable polarity TIG and the result is theoretically investigated to figure out the mechanism. Conventionally, it is well known fact that DCEP (reverse polarity) arc is effective on aluminum welding. The reason is due to oxide layer removal by plasma ion bombardment and therefore it is named as cleaning effect. Another fact of polarity characteristic is that DCEN shows higher heat input efficiency therefore conventional variable polarity arc used to apply DCEP portion as small as possible. However, higher DCEP portion shows bigger weldment in this research and it is explained by adopting a theory of arc concentration on oxide layer with tunneling effect which was not clearly mentioned before in several variable polarity TIG welding research. Disagreement between variable polarity TIG welding result and conventional arc polarity theory is rationally explained for the first time with help of electron emission theory.

Effect of the Polarity of Alignment Film in Amorphous TN-LCD for Response Time and Viewing Angle Characteristics (배향막의 극성이 아몰퍼스 TN-LCD의 응답속도와 시야각 특성에 미치는 효과)

  • Seo, Dae-Shik;Lee, Chang-Hoon;Lee, Bo-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1579-1581
    • /
    • 1997
  • We investigated the effect of polarity of polyimide(PI) film in amorphous (a) - twisted nematic (TN) - liquid crystal display(LCD) for response time and viewing angle. We found that the domain size of a-TN-LCD on PI film with high polarity is smaller then medium polarity. It is considered that the electro-optical characteristics are strongly dependent on this domain in a-TN-LCD. We observed the response time of a-TN-LCD on PI film with high polarity is slow as comparing to PI film with medium polarity. We suggest that the response time of a-TN-LCD is attributed surface effect between the LCs and the substrates.

  • PDF

Dependence of Quiet Time Geomagnetic Activity Seasonal Variation on the Solar Magnetic Polarity

  • Oh, Suyeon
    • Journal of Astronomy and Space Sciences
    • /
    • v.30 no.1
    • /
    • pp.43-48
    • /
    • 2013
  • The geomagnetic activity shows the semiannual variation stronger in vernal and autumnal equinoxes than in summer and winter solstices. The semiannual variation has been explained by three main hypotheses such as Axial hypothesis, Equinoctial hypothesis, and Russell-McPherron Effect. Many studies using the various geomagnetic indices have done to support three main hypotheses. In recent, Oh & Yi (2011) examined the solar magnetic polarity dependency of the geomagnetic storm occurrence defined by Dst index. They reported that there is no dependency of the semiannual variation on the sign of the solar polar fields. This study examines the solar magnetic polarity dependency of quiet time geomagnetic activity. Using Dxt index (Karinen & Mursula 2005) and Dcx index (Mursula & Karinen 2005) which are recently suggested, in addition to Dst index, we analyze the data of three-year at each solar minimum for eight solar cycles since 1932. As a result, the geomagnetic activity is stronger in the period that the solar magnetic polarity is anti-parallel with the Earth's magnetic polarity. There exists the difference between vernal and autumnal equinoxes regarding the solar magnetic polarity dependency. However, the difference is not statistically significant. Thus, we conclude that there is no solar magnetic polarity dependency of the semiannual variation for quiet time geomagnetic activity.

The Impact of Brightness, Polarity, and Hue Difference on Legibility and Emotional Effect of Word in Visual Display (시각디스플레이에서 단어와 배경간의 밝기, 대비부호, 색상차이에 따른 가독성 및 감성효과)

  • Jung, Hye-Heon;Cho, Kyung-Ja;Han, Kwang-Hee
    • Korean Journal of Cognitive Science
    • /
    • v.17 no.4
    • /
    • pp.337-356
    • /
    • 2006
  • This research was conducted to see the impact of brightness, polarity, and hue diference on legibility and emotional effcts of the word. In the experiment 1, stimuli with three levels of brightness difference and two-typed polarity were used. The results showed that legibility, aesthetics, and preference increased with increasing brightness difference. In the experiment 2, the same stimuli if experiment 1 included four hues: red, green, blue, yellow. As a result, the effects of brightness and polarity and the interaction effect of brightness and polarity on legibility were significant. Also, the effects of brightness, polarity, and hue and the interaction effect of brightness and hue on aesthetics and preference were significant. These results showed that legibility, aesthetics, and preference increased with increasing brightness difference of word and background and positive polarity was better than negative. Aesthetics and preference rating increased according to the following order: red, blue, green, yellow. In addition, the interaction effect of brightness and polarity on legibility was because reaction time of negative polarity was longer than positive at the small brightness difference condition. The interaction effect of brightness and hue on aesthetics and preference ws because the aesthetics rating of hue at the large brightness difference condition had significant difference compared with small brightness difference. In the experiment 3, participants rated text designs and simple color stimuli with 18 emotional adjectives to see the similarity of their emotion. The conclusion was that to reflect the subjective feelings of a rotor on the text design, it would be appropriate to use the rotor on background of the text design.

  • PDF

A Study of Polarity Effect of Parallel Plate Type ionization Chamber with Different Volume (평행평판형 전리함의 두 전극간의 거리에 따른 극성효과 연구)

  • 윤형근;신교철
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.69-73
    • /
    • 2002
  • Exposure measurement data with parallel plate ionization chambers were known to depend on the polarity ($k_{pol}$) effect. In this work, the polarity effect were investigated for three parallel plate ionization chambers with different volume. The ionization chamber was fabricated using acrylic plate for the chamber medium and printed circuit board for electrical configuration. The various sizes of the sensitive volumes designed so far were 0.9, 1.9, and 3.1 co. High voltage generator was fabricated using the conventional 9 V batteries to apply the high voltage (300-500 V) to the electrode of the parallel plate ionization chamber. The gap between two electrodes ranged from 3, 6, and 10mm. As the result of our experiment, the polarity effect was within 0.5% in photon beam and 1% to 3.5% in the electron beams. Among electron beams, 16 MeV beam, which had highest energy, showed less polarity effect than electron beams with other energies.

  • PDF

Study on of polarity effect on alignment film in transcription-aligned TN-LCD (전사배향 TN-LCD 에서의 배향막의 극성효과에 관한 연구)

  • Kim, Jin-Ho;Seo, Dae-Shik
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1812-1814
    • /
    • 1999
  • The effects of polarity of the polymer on transcription-aligned twisted nematic (TN)-liquid crystal display (LCD) on various the polyimide (PI) surfaces were investigated. The monodomain alignment of nematic (N)LC is obtained in cells fabricated by transcription alignment method on PI surface with medium polarity. The LC alignment using transcription alignment method is attributed to polarity of the polymer. The threshold voltage of transcription-aligned TN-LCD decreases with increasing the polarity of the polymer on three kinds of the PI surfaces. The threshold voltage of transcription-aligned TN-LCD on PI surface with high polarity is almost the same compared to rubbing-aligned TN-LCD. The response time of transcription-aligned TN-LCD decreases with the increasing the polarity of the polymer on all PI surfaces. The decay time of transcription-aligned TN-LCD is slow compared with the rubbing-aligned TN-LCD.

  • PDF

Theoretical background discussion on variable polarity arc welding of aluminum (가변 극성 알루미늄 아크 용접의 이론적 배경 고찰)

  • Cho, Jungho;Lee, Jungjae;Bae, Seunghwan;Lee, Yongki;Park, Kyungbae;Kim, Yongjun;Lee, Junkyung
    • Journal of Welding and Joining
    • /
    • v.33 no.2
    • /
    • pp.14-17
    • /
    • 2015
  • Cleaning effect is well known mechanism of oxide layer removal in DCEP polarity. It is also known that DCEN has higher heat input efficiency than DCEP in GTAW process. Based on these two renowned arc theories, conventional variable polarity arc for aluminum welding was set up to have minimum DCEP and maximum DCEN duty ratio to achieve the highest heat input efficiency and weldability increase. However, recent several variable polarity GTA research papers reported unexpected result of proportional relationship between DCEP duty ratio and heat input. The authors also observed the same result then suggested combination of tunneling effect and random walk of cathode spot to fill up the gap between experiment and conventional arc theory. In this research, suggested combinational work of tunneling effect and rapid cathode spot changing is applied to another unexpected phenomena of variable polarity aluminum arc welding. From previous research, it is reported that wider oxide removal range, narrower bead width and shallower penetration depth are observed in thin oxide layered aluminum compared to the case of thick oxide. This result was reported for the first time and it was hard to explain the reason at that time therefore the inference by the authors was hardly acceptable. However, the suggested combinational theory successfully explains the result of the previous report in logical way.

Characteristics of a Flux-Lock Type Superconducting Fault Current Limiter According to the Parallel Connection of the Superconducting Elements. (초전도 한류소자의 병렬연결에 따른 자속구속형 초전도 한류기의 특성 분석)

  • Oh, Kum-Gom;Jung, Byung-Ik;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.198-201
    • /
    • 2008
  • We investigated the operating characteristics of the flux-lock type superconducting fault current limiter(SFCL) with the parallel connection between the primary and secondary windings which are connected with two superconducting units in series. The parallel connection for current level increase of the flux-lock type SFCL is necessary to apply the SFCL into the power system. The resistance generated in superconducting units was dependent upon the winding direction of the primary and the secondary coils, which can reduce the power burden. The resistance of the superconducting elements in the subtractive polarity winding is higher than that of the additive polarity winding. The fault current limiting effect of the subtractive polarity winding is better than that of the additive polarity winding. From this results, we confirmed that the power capacity of the flux-lock type SFCL could be increased by the parallel connection of the superconducting units.

A Study on the Effect of Space Charge and tole Dielectric Breakdown of PEF for Electric Installation (전기설비용 PET의 절연파괴와 공간전하효과에 관한 연구)

  • 윤성도;박상현;정학수;서장수;박중순;국상훈
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1992.11a
    • /
    • pp.37-40
    • /
    • 1992
  • This paper examined the existance behavior of charged particles by measuring polarity inversion current Thermal Stimulate Current (TSC) and analysed appearance mechanism of polarity inversion current Peak and Also investigated relation between ionic space charge format ion and dielectric breakdown by measuring D.C breakdown impulse breakdown D.C - impulse superposition as a sample of FET. As a result. lie found that dielectric breakdown is likely to happen due to ionic space charge at the transient state when applied polarity inversion voltage and that charged partion of TSE Peak at the high temperature was the same as that of polarity inversion current. Also there was no effect on ionic space charge about the dielectric breakdown in stationary state when applied D.C voltage.

  • PDF

Characteristics of DC Corona Discharges Caused at the tip of a Needle-shaped Electrode Placed in the Homogeneous Electric Fields (균등전계 중에 놓인 침상 전극의 끝단에서 발생한 직류 코로나방전 특성)

  • Kim, Tae-Ki;Kim, Seung-Min;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.74-81
    • /
    • 2015
  • In the measurement of atmospheric static electric field, it is important to know characteristics of corona discharges caused at the tip of test electrode. This paper presents the fundamental data of DC corona discharges that occurred at the tip of a needle-shaped electrode placed in the homogeneous background electric field which simulates the atmospheric static field under thundercloud. The major characteristics of interest for this purpose are the polarity effect of corona discharges and the magnitudes and time intervals of corona current pulses. The experimental set-up consists of the plate-to-plate configuration with a needle-shaped protrusion, DC power supply, and voltage and current measuring devices. As a result of experiments, the polarity dependence of corona pulses is significantly pronounced. The time intervals between successive corona pulses in the negative polarity is much longer than those in the positive polarity. The time intervals for both polarities is drastically decreased as the applied electric field is increased. Also the magnitudes of the positive corona pulses are slightly changed with an increase in applied electric field, but those of the negative corona pulses are linearly increased with increasing the applied electric fields.