• Title/Summary/Keyword: Point-of-care testing

Search Result 75, Processing Time 0.023 seconds

Evaluation of Particle Counting by Smartphone-based Fluorescence Smartscope and Particle Positioning in Spinning Helical Channel (스마트폰 기반 형광 smartscope의 입자계수 및 회전하는 나선형 채널의 입자정렬 성능 평가)

  • Park, Eunjung;Kim, Subin;Cho, Myoung-Ock;Kim, Kyunghoon;Shourav, Mohiuddin Khan;Kim, Sunwook;Lee, Jeonghoon;Kim, Jung Kyung
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.3
    • /
    • pp.19-28
    • /
    • 2015
  • With the aim of developing a smartphone-based point-of-care device that is small, inexpensive, and easy to handle by non-expert, we designed a fluorescence smartscope for counting particles and a DC motor-controlled particle positioning system. Our smartscope can count the number of fluorescent particles and fluorescently-stained white blood cells through a phone camera with an adaptor containing a LED, a ball lens and optical filters and an application running on a smartphone. The motor was controlled wirelessly via Bluetooth with an Android smartphone. We found that axial spinning of a helical microfluidic channel allows arrangement of particles having size similar to the white blood cells. The motor-controlled particle positioning system can minimize time-consuming manual processes and automate sample preparation process and thus, if integrated with the smartscope, it can be used for a point-of-care testing device based on a smartphone.

Statistical Test of Agreement between Measurements in Method-comparison Study (검사법의 일치도 평가를 위한 분석기법)

  • Pak, Son-Il;Oh, Tae-Ho
    • Journal of Veterinary Clinics
    • /
    • v.28 no.1
    • /
    • pp.108-112
    • /
    • 2011
  • In clinical settings, researchers often want to assess agreement between two measurements (or tests) of the same continuous variable. For example, when new point-of-care analyzer for testing blood glucose level were introduced clinicians need to compare results from standard or established laboratory method of measurement to those of new or point-of-care analyzer. The question in a method-comparison study would either of two different methods be used to measure the same variable equivalently. In this paper common misuse of statistical methodologies seen in the medical literatures such as correlation coefficient and paired t-test are discussed. The Bland-Altman technique has been widely used for this purpose and provides a graphic in presentation of the findings from a method-comparison study, with a mean value of measurement, this bias and the limits of agreement. For ease of application and interpretation of this technique we discussed the analysis procedure and illustrated with two worked examples. Finally, a number of alternative ways in which data can be analysed and reported in such studies were reviewed.

Rapid and sensitive detection of Salmonella species targeting the hilA gene using a loop-mediated isothermal amplification assay

  • Chu, Jiyon;Shin, Juyoun;Kang, Shinseok;Shin, Sun;Chung, Yeun-Jun
    • Genomics & Informatics
    • /
    • v.19 no.3
    • /
    • pp.30.1-30.8
    • /
    • 2021
  • Salmonella species are among the major pathogens that cause foodborne illness outbreaks. In this study, we aimed to develop a loop-mediated isothermal amplification (LAMP) assay for the rapid and sensitive detection of Salmonella species. We designed LAMP primers targeting the hilA gene as a universal marker of Salmonella species. A total of seven Salmonella species strains and 11 non-Salmonella pathogen strains from eight different genera were used in this study. All Salmonella strains showed positive amplification signals with the Salmonella LAMP assay; however, there was no non-specific amplification signal for the non-Salmonella strains. The detection limit was 100 femtograms (20 copies per reaction), which was ~1,000 times more sensitive than the detection limits of the conventional polymerase chain reaction (PCR) assay (100 pg). The reaction time for a positive amplification signal was less than 20 minutes, which was less than one-third the time taken while using conventional PCR. In conclusion, our Salmonella LAMP assay accurately detected Salmonella species with a higher degree of sensitivity and greater rapidity than the conventional PCR assay, and it may be suitable for point-of-care testing in the field.

BioMEMS-EARLY DISEASE DETECTION (BioMEMS 기반의 조기 질병 진단 기술에 관한 연구)

  • Singh, Kanika;Kim, Kyung-Chun
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2781-2784
    • /
    • 2007
  • Early detection of a disease is important to tackle treatment issues in a better manner. Several diagnostic techniques are in use, these days; for such purpose and tremendous research is going on to develop newer and newer methods. However, more work is required to be done to develop cheap and reliable early detection techniques. Micro-fluidic chips are also playing key role to deliver new devices for better health care. The present study focuses on a review of recent developments in the interrogation of different techniques and present state-of-the-art of microfluidic sensor for better, quick, easy, rapid, early, inexpensive and portable POCT (Point of Care testing device) device for a particular study, in this case, bone disease called osteoporosis. Some simulations of the microchip are also made to enable feasibility of the development of a blood-chip-based system. The proposed device will assist in early detection of diseases in an effective and successful manner.

  • PDF

Point-of-care Testing Device Interface in Hospital Information System Standard Connectivity - Using of case ASTM protocol of ABGA application POCT1-A2 - (현장형 임상검사장비와 병원정보시스템의 접속표준 - ASTM protocol을 사용하는 ABGA의 POCT1-A2적용사례 중심으로 -)

  • Kim, Seon-Chil
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.2
    • /
    • pp.33-37
    • /
    • 2008
  • To keep the online medical records available to anyone without constraint of time and space, introducing EMR (Electronic medical record), which is a clinical support management system. The purpose of this study is to develop interface standard of clinical test device. Integration and sharing of medical information is faced with enormous obstacles because medical organizations and associated companies are separately developing the interface. I hope that multi-function management system with workstation concept is operated to efficiently transmit clinical device result data based on this study. Transfer of precise medical result data available for decision making will improve quality of health care service.

  • PDF

Relationship between sonorheometry parameters and laboratory values in a critical care setting in Italy: a retrospective cohort study

  • Antonio Romanelli;Renato Gammaldi;Alessandro Calicchio;Salvatore Palmese;Antonio Siglioccolo
    • Journal of Trauma and Injury
    • /
    • v.36 no.3
    • /
    • pp.210-216
    • /
    • 2023
  • Purpose: This preliminary retrospective cohort study analyzed the relationship between the parameters provided by sonorheometry device Quantra and the coagulation values obtained from standard venous blood samples in patients admitted in intensive care unit (ICU). Methods: We reviewed medical charts of 13 ICU adult patients in whom at least one coagulation study with Quantra was performed. The relationship between Quantra and laboratory data was analyzed with the Spearman rank correlation coefficient (rho). The 95% confidence interval (CI) was computed. A P-value <0.05 was considered statistically significant. Results: We collected 28 data pairs. Statistically significant moderate correlations were found for the following parameters: clot time (CT) and activated partial thromboplastin time (rho=0.516; 95% CI, 0.123-0.904; P=0.009; clot stiffness (CS) and the international normalized ratio (INR; rho=0.418; 95% CI, 0.042-0.787; P=0.039); INR and platelet contribution to CS (rho=0.459; 95% CI, 0.077-0.836; P=0.022); platelet count and platelet contribution to CS (PCS; rho=0.498; 95% CI, 0.166-0.825; P=0.008); and fibrinogen and fibrinogen contribution to CS (FCS; rho=0.620; 95% CI, 0.081-0.881; P=0.001). Conclusions: Quantra can provide useful information regarding coagulation status, showing modest correlations with the parameters obtained from laboratory tests. During diffuse bleeding, CT and FCS values can guide the proper administration of clotting factors and fibrinogens. However, the correlation of INR with CS and PCS can cause misinterpretation. Further studies are needed to clarify the relationship between Quantra parameters and laboratory tests in the critical care setting and the role of sonorheometry in guiding targeted therapies and improving outcomes.

AIDS Related Knowledge and Attitudes Among School Nurses in Chonbuk Province (전북지역 양호교사의 AIDS 관련 지식과 태도 조사연구)

  • 정영숙;문영희
    • Korean Journal of Health Education and Promotion
    • /
    • v.11 no.2
    • /
    • pp.33-47
    • /
    • 1994
  • AIDS preventional efforts need to be guided by well trained health care personnel especially by school nurses for the adolescents. This study was designed to get basic data about AIDS educational program development for school nurses. The objectives of this study were to 1) identify AIDS knowledg of school nurses 2) identify AIDS attitudes of school nurses and 3) identify association between AIDS knowledge and sociodemographic characteristics. Data were collected from 173 subjects in Chonbuk province. Self-reporting questionnaire were administered during the period from 1st of June to 30th of June, 1994. AIDS related knowledge was measured by using 44 questions on cause(3 items), testing(3 items), mode of transmission(15 items), clinical manifestations(5 items), treatment(3 items), prevention(5 items), complication(4 items), infection control(3 items) and Using resources(3 items). AIDS related attitudes were measured by five point Likert scales using 13 questions on perceived threats from AIDS crisis (4 items), perceived severity to AIDS(2 items), perceived needs about psychosocial care for HIV infected patients(3 items) and perceived educational needs of AIDS(4 items). The collected data were analyzed by SPSS/PC/sup +/, using percentages, Mean and S.D. descriptive purpose and t-test or F for comparing the variables. The major findings were as follows: 1. Respondents ranged in knowledge of AIDS between 0 and 44 with the 33.79 mean score. Percentage of correctly answered respondents to each categories - mode of transmission : 87.0% - clinical manifestation : 85.0% - cause : 82.5% - prevention : 81.5% - treatment : 76.1% - infection control : 72.8% - testing of HIV infection 71.8% - using community resourses : 50.9% - complication : 45.8% 2. The respondents' attitudes of AIDS The majority(70%) showed higher perceived threat The majority(91.3%) showed higher perceived severity to AIDS crisis As a whole, perceived needs about psychosocial care for HIV infected patients negative The majority (over 96.5%) showed highly perceived educational needs of AIDS. 3. The relationship between AIDS knowledge and each of those general character. AIDS knowledge shows significant difference with age(F=3.50, p<.016), years of professional experience(F=4.14, p<.007) and received lecture about AIDS(F=4.54, p<.000). There was no significant difference between AIDS knowledge and job satisfaction.

  • PDF

A Study on the Characteristics of the Demented Elderly staying at home (서울시 일개 구 재가 치매노인 특성 연구 -일반노인과의 비교를 중심으로-)

  • Oh, Jin-Ju;Kim, Hee-Girl;Kwon, Young-Suk
    • Research in Community and Public Health Nursing
    • /
    • v.12 no.1
    • /
    • pp.214-225
    • /
    • 2001
  • The purpose of this study is to compare the characteristics of the demented elderly and normal elderly over 65 staying at home in Seoul. Here, the demented elderly are defined as the aged who score under 20 on the MMSE-K testing. The subjects were 15.104 elders in home. The method is a cross-sectional study home visiting survey with questionnaires. Data analyses were conducted by using frequency, percentage, t-test and ANOVA procedures. Results are as follows: First, general characteristics such as sex, age, marriage, education, physical health, and family characteristics such as economic level and single living showed a significant variance between demented elderly and normal elderly. Second, the demented elderly showed a significantly high point of AD and IADL. Third, in contrast with normal agents, the dementia showed a high need for assistance from the care giver but followed the same pattern. In conclusion, the above findings suggested that a social support system should be developed for the demented elderly and care givers in the home.

  • PDF

A Study on the Spiritual Wellbeing of the Hospice Patients (호스피스 환자의 영적 안녕 상태에 관한 조사 연구)

  • Kim Chung nam;Song Mi ok
    • Journal of Korean Public Health Nursing
    • /
    • v.17 no.2
    • /
    • pp.255-265
    • /
    • 2003
  • This study was conducted to provide a baseline data for hospice nurses to improve their practices for the spiritual wellbeing of their clients. Analysis of the spiritual wellbeing status of hospice patients was conducted from April 20 to June 20, 2002. A total of 59 cancer patients who admitted to hospice care units of one university medical center, and who have alert mental status were recruited for the study. Paloutzian and Ellison (982) spiritual wellbeing scale and Jungho Kang (996) scale, which was modified for the cancer patients, were used as the study instruments, ANOVA and T-test were applied using SPSS win 10.0 for statistical analysis. The results are as follows : 1. The mean spiritual wellbeing score of the hospice patients was $49.76(SD\pm7.95)$. When it was converted into 4 point scale, the mean score for the spiritual wellbeing was 2.49. The mean religious wellbeing score was $24.17 (SD\pm5.56)$ and that of the existential wellbeing was $25.59 (SD\pm3.10)$. 2 The mean score for the total spiritual wellbeing was $52.54 (SD\pm8.12)$ for female, and $47.86 (SD\pm6.95)$ for male and the difference was statistically significant (t=-2.305, p=.025), 3. In testing the spiritual wellbeing, there was significant difference according to the religion (F=28.931, p=.000). 4. In testing the religious wellbeing, the mean score was $22.77 (SD\pm5.35)$ for male, and $26.20 (SD\pm5.32)$ for female and the difference was statistically significant (t=-2.430, p=.019). 5. In testing the religious wellbeing, there was significant difference according to the religion (F=37.522, p=.000). However, the religious wellbeing was not different according to the age, occupation, marital status and education level. 6. In testing the existential wellbeing. there was significant difference according to the religion (F=8.147, p=.000). However, mean score for the existential wellbeing was not significantly different according to sex, age, occupation, marital status and education level. 7. In testing the existential wellbeing, there was significant difference according to the level of vigor (F=3.662, p=.032), while no difference was observed in the existential wellbeing according to the general health status, degree of pain, and diagnosis. From the results described above it can be concluded that : To improve the spiritual wellbeing status of hospice patients, hospice nurses should identify spiritual needs of the patients according to the religion. gender and the level of vigor.

  • PDF

A Study on Self Care Compliance Related to Infection Management for Continuous Ambulatory Peritoneal Dialysis Patients (복막투석환자의 감염예방과 관련된 자가간호 이행에 관한 연구)

  • Lee Eun-Young;Kim Jung-Soon
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.5 no.2
    • /
    • pp.313-323
    • /
    • 1998
  • This study was a descriptive research on the level of self-care available to continous ambulatory peritoneal dialysis patients (hereinafter referred to as 'CAPD patient') related to the specific area of infection management. The method employed for the collection of data was a modified instrument of the self-care survey essentially based on Young Sook Choi's instrument. The relevant data was collected from september 1, 1996 to september 30, 1996. The subjects were provided with an open-ended question regarding the reasons behind why they did not seek self-care. The answers provided about self-care compliance were analyzed by SPSS for frequency, percentage, mean, t-test, ANOVA. Reasons for non-compliance were analyzed by content analysis. The results of the study were as follows : 1. The percentage of patients engaging in self-care were according to the following self performed tasks : preparation of dialysis : 30.58 points Dialysate exchange procedures : 49.40 points - Two bag type : 50.50 points - Spike type : 48.80 points - Neo type : 48.90 points Catheter exit site care : 25.13 points More specifically, in relation to the preparation of dialysis as referred to above, those patients engaging in self care was relatively high with respect to the cleaning of the dialysis before use and for the preservation of peritosol. However, in dialysate exchange procedures, data revealed that those patients engaging in self-care are relatively low with respect to putting on a mask during the performance of peritosol exchange. Similary in peritosol exchange procedure and catheter exit care, low levels of self-care performance were found in the area of putting on a mask during the peritosol exchange procedures and catheter line testing procedures, respectively. 2. In general characteristics, there appeared to be no distinction in self-care compliance among CAPD patients. 3. The main reasons for non-compliance were based in the following factor : intellectual, attitude, enviromental surrounding and physical. As a result of the foregoing finding, nurses should provide adequate assistance to promote self-care compliance by CAPD patients by checking the preparation of dialysis, dialysate exchange procedure, and catheter exit site care which recieved low point in this research.

  • PDF