• Title/Summary/Keyword: Point light source

Search Result 148, Processing Time 0.025 seconds

A Gi-point in Taoists and the conception of Life Gate in Korean medicine (도가(道家)의 기혈(氣穴)과 한의학(韓醫學)의 명문사상(命門思想))

  • Jeon, Hark-Soo;Noh, Young-Kyun
    • Journal of the Korean Institute of Oriental Medical Informatics
    • /
    • v.14 no.2
    • /
    • pp.47-57
    • /
    • 2008
  • This paper aims at the comparative study of practicing Buddhism and Taoism related to "life gate". The term "life gate", as a physiological entity of disputed morphological identity, first appears in The Inner Canon where it refers to the eyes. Reference to a "life gate" as an internal organ body first appears in The Classic of Difficult Issues which states, "The two kidneys are not both kidneys' The left one is the kidney, and the right is the life gate." Successive scholars refers to life gate as a gi point of Taoists.. The question of the life gate invited little discussion until the Myeong and Cheong Dynasty, when various different theories were put forward. Especially Jin Sa-taek says "life gate" is the governor of the twelve place in the human body, throwing light on the meaning of it. Not that life gate denotes a local point, it does a system of life gate. Generally speaking, life gate designates cinnabar field. I think that the human body produces essence by way of life gate. That is, the human body is unified by the system of life gate. Life gate is not only the source of infusing the engine of the human body with vital energy but also as well as gi-point.

  • PDF

Application of plasma lighting for growth and flowering of tomato plants

  • Park, Kyoung Sub;Kim, Sung Kyeom;Lee, Sang Gyu;Lee, Hee Ju;Kwon, Joon Kook
    • Horticulture, Environment, and Biotechnology : HEB
    • /
    • v.59 no.6
    • /
    • pp.827-833
    • /
    • 2018
  • Plasma lighting systems have been engineered to simulate sunlight. The objective of this study was to determine the effects of plasma lighting on tomato plant growth, photosynthetic characteristics, flowering rate, and physiological disorders. Tomato plants were grown in growth chambers at air temperatures of $25/23^{\circ}C$ (light/dark period), in a $16h\;day^{-1}$ light period provided by four different light sources: 1 kW and 700 W sulfur plasma lights (1 SPL and 0.7 SPL), 1 kW indium bromide plasma light, and 700 W high pressure sodium lamp (0.7 HPS) as a control. The totaldry weight and leaf area at 0.7 SPL were approximately 1.2 and 1.3 times greater, respectively, than that of 0.7 HPS at the 62 days after sowing (DAS). The maximum light assimilation rate was observed at 1 SPL at the 73 DAS. In addition, the light compensation and saturation points of the plants treated with plasma lighting were 98.5% higher compared with HPS. Those differences appeared to be related to more efficient light interception, provided by the SPL spectrum. The percentage of flowering at 0.7 SPL was 30.5%, which was higher than that at 0.7 HPS; however, there were some instances of severe blossom end rot. Results indicate that plasma lighting promotes tomato growth, flowering, and photosynthesis. Therefore, a plasma lighting system may be a valuable supplemental light source in a greenhouse or plant factory.

Laser Auto Focus Using Non-Touch Sensor (비접촉 센서를 이용한 레이저 자동 포커싱)

  • 장정원;김재구;신보성;장원석;최지연
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.280-283
    • /
    • 2003
  • In this paper, there was finding laser beam focal length using the camera at the work with laser preprocess. A process have some similarity that the laser direct writing was condition of unused other light source in order to a partical object of working substrate, so we worked finding focal length using yellow light. As we found focal lengths from three points of substrate edges, The focal length of all substrates was able to be computed by calculating a plane equation using these three point. Also we make a device and software that can automatically perform all of the processes.

  • PDF

Demonstration of the Effectiveness of Monte Carlo-Based Data Sets with the Simplified Approach for Shielding Design of a Laboratory with the Therapeutic Level Proton Beam

  • Lai, Bo-Lun;Chang, Szu-Li;Sheu, Rong-Jiun
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.1
    • /
    • pp.50-57
    • /
    • 2022
  • Background: There are several proton therapy facilities in operation or planned in Taiwan, and these facilities are anticipated to not only treat cancer but also provide beam services to the industry or academia. The simplified approach based on the Monte Carlo-based data sets (source terms and attenuation lengths) with the point-source line-of-sight approximation is friendly in the design stage of the proton therapy facilities because it is intuitive and easy to use. The purpose of this study is to expand the Monte Carlo-based data sets to allow the simplified approach to cover the application of proton beams more widely. Materials and Methods: In this work, the MCNP6 Monte Carlo code was used in three simulations to achieve the purpose, including the neutron yield calculation, Monte Carlo-based data sets generation, and dose assessment in simple cases to demonstrate the effectiveness of the generated data sets. Results and Discussion: The consistent comparison of the simplified approach and Monte Carlo simulation results show the effectiveness and advantage of applying the data set to a quick shielding design and conservative dose assessment for proton therapy facilities. Conclusion: This study has expanded the existing Monte Carlo-based data set to allow the simplified approach method to be used for dose assessment or shielding design for beam services in proton therapy facilities. It should be noted that the default model of the MCNP6 is no longer the Bertini model but the CEM (cascade-exciton model), therefore, the results of the simplified approach will be more conservative when it was used to do the double confirmation of the final shielding design.

A Study on the Space interpretation by Application of Color Structure in Contemporary Architecture (현대건축의 색채구조를 적용한 공간해석에 관한 연구)

  • Kim, Sun-Young
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.3
    • /
    • pp.152-160
    • /
    • 2011
  • Contemporary architecture pursues new method of Interpretation of Non-linear space as digital media appears. As various materials and new methods can be used due to developments in science and expansion of thinking, contemporary architectural color developed extensive possibilities. It means not only the change of drawings, method of architectural product and materials but also the change of value system for architectural space. Thus the purpose of this paper is to suggest interpretation of space applied by color structure, and this point of view was based on the three elements of color perception which are light source, reflector, and observer. According to this categorization, architectural color of exterior color, layer color and interaction color are explained via examples of colors recently used on the contemporary architectures. In summary, contemporary architecture can be explained by Non-construction space interpretation for intrinsic complex meanings. Therefore, it can be explained as moving space, collage, by picturesque space, moving blur color and emptiness of color. This pursues various point of views for space interpretation, therefore it can be developed to the identity of strengthening architectures' design concept.

Automatic Alignment of a Differential Detector to the Optical Signal in a Wireless Optical Interconnection (무선광연결에서 신호광에 자동 정렬하는 차동검출기)

  • 이성호
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.5
    • /
    • pp.822-829
    • /
    • 2000
  • In this paper, we introduce a differential detector that automatically aligns itself to the signal beam in order to prevent the voltage variation that may result from minute misalignment of the light source. In this system, a photodiode-array recognizes the central point of the signal beam, and drives motors that correspond to the x and y axes. The photodiode-array aligns itself to the central point of the signal beam, and eliminates the optical noise effect with differential detectioin method. It is very useful in wireless optical interconnections.

  • PDF

Light Intensity and Temperature on Photosynthesis and Respiration of Sumbady Plants (Dystaenia takesimana Kitagawa) (섬바디의 광합성(光合成)과 호흡(呼吸)에 미치는 광도(光度) 및 온도(溫度)의 영향(影響))

  • Hong, Young-Pyo;Park, Hoon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.14 no.4
    • /
    • pp.224-229
    • /
    • 1982
  • Effects of light intensity and temperature on photosynthesis and respiration of autogenous wild SUMBODY plants, Dystaenia takesimana, known as a prospective source of forage in Ulleung island, Korea, were investigated. Results were as follows : 1. Light saturation point at $20^{\circ}C$ was 34 to 38 klux and light compensation point was 4 to 6 klux. Apparent photosynthetic rate at light saturation was 9 to 12 mg $CO_2/dm^2/hr$. 2. Optimum temperature for photosynthesis was $20^{\circ}C$ and $Q_{10}$ values of two temperature ranges, 20 to $30^{\circ}C$ and 30 to $40^{\circ}C$, were 0.8 and 0.9 for photosynthesis, while $Q_{10}$ for respiration were 1.6 and 1.7. 3. Native plants sampled in area of higher altitude had a higher apparent photosynthtic rate at lower temperature and the plants sampled in area of mixed with bushes had lower a light compensation point. These rusults suggest that the Inland weather condition of Korea during spring and fall seasons might be. suitable for the SUMBODY growth but inadequate during summer.

  • PDF

Optic-axis Alignment and Performance Test of the Schwarzschild-Chang Off-axis Telescope

  • Park, Woojin;Pak, Soojong;Chang, Seunghyuk;Jeong, Byeongjoon;Lee, Kwang Jo;Kim, Yonghwan;Ji, Tae-Geun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.42 no.1
    • /
    • pp.56.4-57
    • /
    • 2017
  • The Schwarzschild-Chang off-axis telescope is a "linear astigmatism-free" confocal system. The telescope comprises two pieces of aluminum-alloy freeform mirrors that are fabricated with diamond turning machine (DTM) process. We designed optomechanical structures where optical components in the telescope system can be adjustable on a linear stage. Optomechanical deformation caused by the weight of system itself and its temperature variation is analyzed by the finite element analysis (FEA). The results show that the deformation is estimated in the tolerance range. For the optic-axis alignment of telescope system, three-point alignment (TPA) method is chosen. The TPA method uses three parallel lasers and a plane mirror. Point source images were taken from collimated light and field observation. The performance of optical system was tested by point spread function and aberration measurement of the point sources.

  • PDF

A Compact Optical System using LED and CMOS Image Sensor for Liver Function Analysis (LED와 CMOS 이미지 센서 기반 간 기능 분석용 소형 광학장치)

  • Kim, Chul;Lim, Chang-Jin;Nam, Myung-Hyun;Kim, Dong-Sik;Seo, Sung-Kyu;Pak, Jung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.2
    • /
    • pp.270-275
    • /
    • 2012
  • This paper presents a portable and compact optical device which can conveniently be used to perform a functional analysis of human liver function. The proposed system employed red/green LEDs, as a light source, and CMOS image sensor, which is commonly used in cellular phones. With this system, several blood serum samples have been evaluated for liver functional analysis by measuring light absorption level through the blood serum samples depending on aspartate aminotransferase (AST), alanine aminotransferase (ALT), and total bilirubin concentration. The light absorption through the blood serum samples containing AST, ALT, or total bilirubin can provide their concentrations. The green light absorption is more sensitive to the concentration of AST or ALT, and the red light absorption is more sensitive to the total bilirubuin concentration. Additional calibration steps were performed by using a MATLAB program in order to eliminate the light scattering effects from the extraneous particles existing in each blood serum sample. From the blind test, three standard light intensity curves through each enzyme have been obtained and the enzyme concentration values have been compared to those obtained from a commercially available biochemistry analyzer (Toshiba 200 FR). The average percent difference in the obtained concentrations from two systems for AST, ALT, and total bilirubin concentration came out to be 7.79%, 7.98%. and 7.56%, respectively, with the adjusted coefficient of determination (R2) higher than 0.98. This system can possibly lead to a low-cost and simple system that can be used as a point-of-care (POC) system in a condition without advanced equipments.

Optical Simulation Study on the Effect of Diffusing Substrate and Pillow Lenses on the Outcoupling Efficiency of Organic Light Emitting Diodes

  • Jeong, Su Seong;Ko, Jae-Hyeon
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.3
    • /
    • pp.269-274
    • /
    • 2013
  • The effect of diffusing substrate and pillow lenses on the outcoupling efficiency of organic light-emitting diodes (OLEDs) was studied by optical simulation based on the point-dipole model. The diffusing substrate included Mie scatterers by which the condition of total internal reflection could be broken. The finite-difference time-domain method was used to obtain the intensity distribution on the transparent electrode of an OLED, which was used as a light source to carry out a ray-tracing simulation of the OLED and the diffusing substrate. It was found that the outcoupling efficiency of the OLED was sensitive to the thickness of organic layers and could be increased by 21.0% by adopting a diffusing substrate in which Mie scatterers whose radius was $2.0{\mu}m$ were included at the density of $10^7mm^{-3}$ and by 65.5% by forming one pillow lens with the radius of 2 mm on the front surface of the glass substrate. This study revealed that the outcoupling efficiency could be improved by adopting diffusing substrate and pillow lenses along with the optimization of the thickness of each layer in the OLED.