• Title/Summary/Keyword: Point Configurations

Search Result 159, Processing Time 0.022 seconds

THE STUDY ABOUT THE MARGINAL FIT OF THE CASTING TITANIUM AND MACHINE-MILLED TITANIUM COPINGS (주조티타늄과 기계절삭티타늄 코핑의 변연적합성에 관한 연구)

  • Oh Su-Yeon;Vang Mong-Sook;Yang Hong-So;Park Sang-Won;Park Ha-Ok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.20-28
    • /
    • 2006
  • Statement of problem: The titanium has advantages of a high biocompatibility, a corrosion resistence, low density, and cheep price, so it is focused as a substituted alloy But it is quite difficult to cast with the tranditional method due to the high melting point, reacivity with element at, elevated temperature. By using the CAD-CAM system for the crown construction, it is possible to reduce the errors while proceeding the wax-up, investing, and casting procedure Purpose: The purposes of this study were to measure the marginal adaptation of the casting titanium coping and machine-milled titanium coping according to the casting methods and the marginal configurations. Material and method: The marginal configurations were used chamfer shoulder, and beveled shoulder. The total 30 copings were used, and these are divided into 6 groups according to the manufacturing method and marginal configuration. The gap between margin of the model and the restoration was measured with 3-dimensional measuring microscope. Results: The following results were obtained; 1. casting gold coping demonstrated the best marginal seal, followed by casting titanium coping finally machine-milled titanium copings. 2. In casting titanium coping, chamfer demonstrated the best marginal seal, followed by shoulder and beveled shoulder. There was no significantly difference in shoulder and beveled shoulder. But all margin form has clinically acceptable 3. In machine-milled titanium copings, chamfer demonstrated the best marginal seal, followed by shoulder and beveled shoulder. Beveled shoulder show large and uneven marginal gap Conclusions: Above result revealed that marginal adaptation of the titanim coping is avail able in the clinical range, it can be used as an alternative metal and it is prefered especially in chamfer or shoulder margin during implant superstructure fabrication. But there should be more research on machine-milled titanium in order to use it in the clinics.

Investigations into the Cylinder Flow Stabilities with a Thin Film Attachment

  • Doh, Deog-Hee;Jo, Hyo-Je;Kwon, Seang-Yong;Kim, Hyoung-June;Cho, Gyeang-Rae;Shin, Byeong-Rog
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.7
    • /
    • pp.957-965
    • /
    • 2011
  • The wakes of a cylindrical body have been investigated. The cylindrical body was attached with a thin film. The film is made of silicon with configurations of 50mm(W) ${\times}$ 150mm(L) ${\times}$ 0.3mm(T). The cylinder wakes have been measured with PIV experiments under the conditions with and without the thin film. The diameter of the installed cylinder body is 30mm and the Reynolds numbers are 2730, 6160 and 9750 with the diameter. The measurement system consists of an Ar-ion laser(6W), a high speed camera(1024 ${\times}$ 992 pixel, 500fps) and a host computer. FFT analyses have been carried out using the velocity vectors obtained by PIV measurements at the point X/D=1.52 and Z/D=0.52. For understanding the three-dimensional flow structures, a new Volumetric PTV(particle tracking velocimetry) has been constructed, in which the same four high-resolution cameras have been used. It has been verified that the flexible film suppresses or damps the vortices separated from the cylinder body, which makes the cylinder's wakes stable. With increase of Re numbers the intensity of the dominant frequency of the wakes become smaller.

Does matching relation exist between the length and the tilting angle of terminal implants in the all-on-four protocol? stress distributions by 3D finite element analysis

  • Li, Xiaomei;Cao, Zhizhong;Qiu, Xiaoqian;Tang, Zhen;Gong, Lulu;Wang, Dalin
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.240-248
    • /
    • 2015
  • PURPOSE. To explore whether there is matching relation between the length and the tilting angle of terminal implants in the All-on-Four protocol by studying the effects of different implant configurations on stress distributions of implant, bone, and framework. MATERIALS AND METHODS. Four implants were employed to support a full-arch fixed prosthesis and five three-dimensional finite element models were established with CT images, based on the length (S and L) and distal tilt angle ($0^{\circ}$, $30^{\circ}$ and $45^{\circ}$) of terminal implants for an edentulous mandible, which named: Tilt0-S, Tilt30-S, Tilt30-L, Tilt45-S and Tilt45-L. An oblique 240 N was loaded at second molar. The von Mises Stresses were analyzed. The implants were consecutively named #1 to #4 from the loading point. RESULTS. 1) Tilt0-S had the greatest stress on the implants, with the other groups exhibiting variable reductions; the four implants of Tilt45-L demonstrated the greatest reduction in stress. 2) Tilt0-S had the greatest stress at bone around #1 implant neck, and Tilt45-L exhibited the least stress, which was a 36.3% reduction compared to Tilt0-S. 3) The greatest stress in the framework was found on the cantilevers distal to #1 implant. Tilt45-S exhibited the least stress. CONCLUSION. Matching different length and tilting angle of the terminal implants led to variable stress reductions on implants, bone and the superstructure. By optimizing implant configuration, the reduction of stress on implants and surrounding bone could be maximized. Under the present condition, Tilt45-L was the preferred configuration. Further clinical testings are required.

A Study on Architectural Design Factors for Tall Office Buildings with Regional Climates based on Sustainability

  • Cho, Jong Soo
    • Architectural research
    • /
    • v.7 no.2
    • /
    • pp.13-21
    • /
    • 2005
  • Throughout history, buildings have been interrelated with certain indigenous characteristics such as regional climate, culture and religions. In particular, the control of regional climate has been primarily a concern for compatibility with nature. In our modern age, technologies to control climate have been successfully developed in architecture but the consumption of large quantities of natural resources can also produce environmental problems. This study is based on the proposition that this negative trend can be minimized with architectural design that is motivated to coexist with a regional climate. This study develops these design strategies for tall office buildings by analyzing various combinations of building design configurations based on regional climates. The objective is to determine the optimum architecture of tall office buildings during the initial design process that will reduce energy consumption for regional climatic conditions. The eQUEST energy simulating program based on DOE-2.2 was used for this comparative analysis study of the energy use in tall office buildings based on architectural design variables and different regional climates. The results are statistically analyzed and presented in functional architectural design decision-making tables and charts. As a result of the comparison of architectural design consideration for tall office buildings in relation to regional climates, buildings physically need less energy consumption when the architecture is concerned with the regional climate and it produces a more reasonable design methodology. In reality, imbalanced planning which is architectural design's lack of regional characteristics requires additional natural resources to maintain desired comfortable indoor conditions. Therefore, the application of integrated architectural design with regional nature should be the first architectural design stage and this research produces the rational. This architectural design language approach must be a starting point to sustaining long-term planning.

AN INVESTIGATION ON HVLS FAN PERFORMANCE WITH DIFFERENT BLADE CONFIGURATIONS (날개 형상에 따른 HVLS의 성능에 관한 연구)

  • Moshfeghi, Mohammad;Hur, Nahmkeon;Kim, Young Joo;Kang, Hyun Wook
    • Journal of computational fluids engineering
    • /
    • v.19 no.4
    • /
    • pp.80-85
    • /
    • 2014
  • High-volume low-speed (HVLS) fans are one category of ceiling fan installed in large enclosings such as warehouses, large barns and health clubs in order to generate comfortable air circulation. As a rotary blade, aerodynamic performance of a HVLS fan is predominantly related to its airfoil(s), and the pitch and twist angles. This paper first, investigates the effects of airfoil on the performances of three different HVLS fans with NACA 5414, 6413 and 7415 airfoils. The fans have six untwisted blades with the diameter of 6 m and rotate at 60 RPM. The blades pitch angels are $12^{\circ}$, $12^{\circ}$ and $13^{\circ}$, respectively. The results are presented in the form of the aerodynamic forces and moments, volumetric flow rate and streamlines. Regarding the volumetric flow of air, the results show that the model with NACA 7415 has the best performance. Hence, two other HVLS fans with the same airfoil but, with four and five blades are studied in order to investigate the effects of number of blades. From the point of view of air circulation still the six-bladed fan is the best one; however, the five-bladed fan is more efficient in power consumption.

Effect of Chamber Configuration on Combustion Characteristic Velocity of Full-scale Combustion Chamber (실물형 연소기의 형상에 따른 연소특성속도 비교)

  • Kim, Jong-Gyu;Han, Yeoung-Min;Ahn, Kyu-Bok;Kim, Mun-Ki;Seo, Seong-Hyeon;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.149-152
    • /
    • 2008
  • Effects of chamber configuration on combustion characteristic velocity of full-scale combustion chamber for 30-tonf-class liquid rocket engine were studied. The configurations of combustion chamber are ablative and channel cooling chamber (${\varepsilon}$=3.2) which have detachable mixing head, and single body regenerative cooling chamber which has nozzle expansion ratio of 3.5 and 12, respectively. The combustion chambers have chamber pressure of 53${\sim}$60 bar and propellant mass flow rate of 89 kg/s, and the injectors of all combustion chamber have recess number 1.0 and double-swirl characteristics. The hot firing test results at design point show that the combustion characteristic velocity of the regenerative cooling chamber which has nozzle expansion ratio of 12 is higher than that of other combustion chambers. The reasons for the above result are the increases of combustion pressure and enthalpy of kerosene which is heated due to cooling of the chamber wall before injection into the combustion field.

  • PDF

Approximate calculation of the static analysis of a lifted stay cable in super-long span cable-stayed bridges

  • Zhao, Xinwei;Xiao, Rucheng;Sun, Bin
    • Structural Engineering and Mechanics
    • /
    • v.74 no.5
    • /
    • pp.635-655
    • /
    • 2020
  • The sag effect of long stay cables is one of the key factors restricting further increase in the span of cable-stayed bridges. Based on the formerly proposed concept of long stay cables lifted by an auxiliary suspension cable in cross-strait cable-stayed bridges, corresponding static approximate calculations and analytical theory based on catenary and parabolic cable configurations are established. Taking a main span 1400 m cable-stayed bridge as the research object, three typical lifting conditions and the whole process of auxiliary cable lifting are analyzed and discussed. The results show that the sag effect is effectively reduced. The support efficiency is only improved when the cables are lifted above the original cable chord. Reduction of the horizontal component force of the cable is limited. The equivalent elastic modulus and the vertical support stiffness of the lifted cables are significantly increased with increased horizontal projection length and not sensitive to the change of the lifting point position. The scheme of lifting the cable to the chord midpoint is more economical because of the less steel required for the auxiliary suspension cable, but its effect on improving the vertical support efficiency is limited. The support efficiency is better when the cable is lifted to the cable end tangential to the original cable chord, but the lifting force and the cross-sectional area of the auxiliary suspension cable are doubled. The approximate calculation results of the lifted cables are very close to the numerical analysis results, which verifies the applicability of the approximation method proposed in this study. The results of parabolic approximation calculations are approximately equal to that of catenary cable geometry. As the parabolic approximation analysis theory of lifted cables is more convenient in mathematical processing, it is feasible to use parabolic approximation analysis theory as the analytical method for the conceptual design of lifted cables of super-long span cable-stayed bridges.

Theory of a Current-Type Electromagnetic Flowmeter for Two-Phase Flow and Numerical Computation of the 3D Virtual Potential Distributions for Annular Flow (2상류용 전류형식 전자기유량계 이론 및 환상류에서의 3차원 가상포텐셜 분포의 수치적 계산)

  • Oh, Byung-Do;Kim, Moo-Hwan;Ahn, Yeh-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.6
    • /
    • pp.714-725
    • /
    • 2003
  • The theory of the current-type electromagnetic flowmeter for a high temporal resolution was developed for two-phase flow measurements. To predict the output of the current-type flowmeter, the three-dimensional virtual potential distribution C and the newly introduced flow pattern coefficient f were derived and computed. The output of flowmeter depends on the liquid conductivity (sensitive to temperature) and flow configurations of the two-phase flow with the sinusoidal excitation over 100 Hz. The flow pattern coefficient was specially devised to separate the dependency on the flow configuration of the two-phase flow from that on the liquid conductivity which can be expressed with the calibration of single-phase flow. Using the finite difference method, the three-dimensional virtual potential distributions were computed for the electrode of finite size. By taking derivative of the virtual potential, the weight functions were evaluated and compared with existing analytic series solution for the point-electrode. There was a reasonable correspondence between the present and existing results. In addition, the flow pattern coefficients were evaluated for annular flows with various film thicknesses, and compared with the experimental results by the impedance spectroscopy. The numerical results agreed well with the experimental data.

A Study of the Cubic Field Splitting Parameter 10Dq by Means of One-Center Expansion of Complex MO (착물 분자궤도함수의 일점 전개에 의한 입방결정장 분열 파라미터 10Dq의 고찰)

  • Hojing Kim;Sangyoub Lee
    • Journal of the Korean Chemical Society
    • /
    • v.22 no.2
    • /
    • pp.67-77
    • /
    • 1978
  • MO's of a complex are expanded in terms of the set of Shull-Lowdin functions based on a single point, the nucleus of central metal ion, and the result was interpreted from the viewpoint of perturbation theory. We find that even in the case of $[NiF_6]^{4-}$, which has relatively small covalency, excited configurations with high orbital angular momentum are considerably mixed into $e_g$ and $t_{2g}$, orbitals of central metal ion, and that the distortions in these orbitals differ from each other. Therefore it is concluded that the energy difference between $e^*_g$ and $t^*_{2g}$, orbitals evaluated in the MO scheme has little meaning of the unique parameter 10Dq in the crystal field theory, and that such a unique parameter cannot be defined in a rigorous sense in the MO scheme.

  • PDF

Effectiveness of the Electrode Arrays for Delineating 2-D Subsurface Structure (2차원 지하구조 규명을 위한 전극배열의 효율성)

  • Yoon, Jong-Ryeol;Lee, Kiehwa
    • Economic and Environmental Geology
    • /
    • v.29 no.3
    • /
    • pp.345-355
    • /
    • 1996
  • The effectiveness of various electrode configurations in horizontal mappings and 1-D inversions of vertical sounding data for delineating 2-D structures was studied. Apparent resistivity values of three point, dipole-dipole, Wenner, and Schlumberger mappings were simulated for such structures as vertical dyke, tabular prism, buried vertical fault, ramp and complex structure by finite difference method (FDM) and they were compared with each other. Also 2-D cross sections for three structures obtained by interpolation of 1-D inverted sounding data in terms of three layers were compared for Schlumberger and Wenner arrays. On these cross sections, horizontal and vertical resistivity interfaces of the 2-D structures are revealed relatively clearly. Apparent resistivity curves of Schlumberger mapping show vertical resistivity discontinuities very well. On the whole, Schlumberger array is superior to the other arrays in electric sounding as well as mapping. This study clearly indicates that interpretations of 2-D structures based on 1-D inversion are possible.

  • PDF