• Title/Summary/Keyword: Point

Search Result 51,643, Processing Time 0.077 seconds

A Clinical Study on Allergic rhinitis (알레르기 鼻炎의 臨床的 硏究)

  • Cho Soo-hyun;Jee Seon-young
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.14 no.2
    • /
    • pp.173-182
    • /
    • 2001
  • This Study is attempted in order to observe a clinical analysis from Constitution medical view point about allergic rhinitis. We studied 71 patients who had visited Dept. surgery, opthalmology & otolaryngology, col1ege of Oriental Medicine, Kyungsan University, Pohang, Korea and were treated by medications of Sasang Constitution and Constitution-Acupunture with allergic rhinitis from March 1, 2000 to February 28, 2001. The results were as follows: 1. The sex distribution was 71 males($69\%$), 22 femail($31\%$), In age distribution, the average was 29.6. The peak age was thirties($36.7\%$), teen-ager was $23.9\%,\;fortieth\;was\;15.5\%,\;under\;10\;years\;old\;was\;9.9\%,\;twenties\;was\;7\%,\;fifties\;was\;5.6\%,\;sixtisth\;was\;1.41\%$. 2. In the age of onset, thirties was $29.6\%$, teen-ager was $19.7\%$, twenties was $18.3\%$, under 10 years old and fortieth was $14.1\%$, fifties was $3.8\%$, sixtisth was $1.41\%$. 3 In monthly distribution. september was $25.8\%$, january was $14.1\%$, october was $11.3\%$. november and august was $8.5\%$, april was $7\%$, febuary and may were $5.6\%$, june, july. December were each $4.2\%$, In the distribution of season. the peak season was fall from september to November. 4. In the duration of the disease, 1-3 years was $26.8\%$, 3-5 years was $19.7\%$, 6 months - 1 year $16.9\%$, 5-10 years was $14.1\%$, under 6 months was $11.3\%$, over 10years and over 15 years were each $5.6\%$. 5. In the three main symptom, hydrorrhoea was $71.8\%$, nasal obstruction was $67.6\%$, sneezing was $64.8\%$. In others, fatique was $25.6\%$, headache was $14.1\%$, itching and cough was $11.3\%$, laryngopharyngeal discomfort and red eye were $4.2\%,\;infirmity\;was\;2.8\%$. 6. Patients whose families have allergic disease account for 26 cases($36.6\%$). 7. There was no past history in 37 cases($52.l\%$). In past history distribution, digestive tract disease was $12.7\%$, paranasal sinusitis was $8.5\%$, allergic dermatitis was $7\%$, common cold was $4.2\%$. otitis media, bronchitis, asthma, tonsillitis were $2.8\%$. 8. Sasang Constitution classification was Soyanggin in 52 cases($73.2\%$), Taeumgin in 12 cases($16.9\%$). Soumgin in 7 cases($9.9\%$). 9. In the duration of treatment, it was 1-2 weeks in 26 cases($36.6\%$), 2-4 weeks was $21.1\%$, under 1weeks was $14.1\%$, 4-6 weeks was $11.3\%$, 6-8 weeks was $8.5\%$, 8-10 weeks was $5.6\%$, over 10 weeks was $2.8\%$. 10. We had a follow-up survey the effect of treatment in the 60 cases. there was fair in 25 cases($41.7\%$), good in 21cases($35\%$), excellent in 3cases($5\%$)로 total rate of treatment was $81.7\%$. The case of no change was $16.7\%$, the case of poor was $1.6\%$.

  • PDF

The influencing effect on E.Q. and personality that both sports activity & speciality aptitude activity in school-childhood can cause (학동기의 스포츠활동과 특기적성활동의 참가가 감성지수 및 성격특성에 미치는 영향)

  • Lee Han-Ki
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.1
    • /
    • pp.140-156
    • /
    • 2004
  • This study, to find whether a sports activity and a speciality aptitude activity in school-childhood can affect in forming E.Q, has been done in Gyoung-Nam area and Busan wide city with asked 222 of men and women being in their school-childhood and a group of 85 people who had not joined in such activity, using a E.Q testing paper provided by Dae-Gyo Education Corp,. and Seoul National University Educational Research Institute. Following is the results after analyzing the compiled datas. 1. The E.Q. level difference between people who joined, and who not joined in a sports action activity was reported existing, the total E.Q average of those who joined was resulted 212.6, a point 29.6 higher than those not joined of 183.0 ( p< .05). As for the E.Q causing points, it resulted that the points of the joined group is generally up than that of the non-joined group, especially this difference was remarkable in terms of feeling recognition or feeling control, a finding that deserves an attention ( p<.05) 2. Joining periods of sports activity did also have relation to develping E.Q. of school-childhood according to this research, the total E.Q points of a group joined in the activity more than 2 years was 215.5 points, which was 17.4 points higher than those not joined of 186.5 points ( p< .05). Backing again to E.Q causing points in this case, it resulted without exeption of all main causes that those who joined in more than 2 years are generally higher than that of those joined less than 2 years, especially the difference was regarded as big in terms of feeling recognition or feeling control, a finding that deserves an attention ( p<.01). 3. The E.Q. differnce between those joined in a specialty aptitude activity and not joined was studied existing, the total E.Q average points of those joined in a specialty aptitude activity was 207.8, a higher figure by 21.3 points than those not joined group of 186.5 ( p< .05). As for the E.Q causing points, it resulted without exeption of all main causes that those who joined are generally higher than that of those not joined, especially for feeling recognition or feeling control, this difference was more clear, a finding that deserves an attention ( p<.01). 4. It also resulted that E.Q growth depends on the periods to have joined in a speciality aptitude activity, for example, the total E.Q points of those joined in the activity more than 2 years was 217.1, a total more higher by 13.5 points than 203.6 of those not joined ( p< .05). For the E.Q. causing points, it, with the exception of empathy was resulted that those who joined in the speciality aptitude activity more than 2 years are generally higher than those joined less than 2 years, especially the difference is remarkable in terms of feeling recognition or feeling control, a finding that is also remarkable ( p<.05). 5. The E.Q difference between the men and women who joined in both activities of sports & speciality aptitude was found existing, the total E.Q. average for women was resulted 214.2 points, which was 9.2 points higher than men of 205.0. As for the E.Q. causing points, which, without exeption of main causes, women's was reported being high than that of men, in special is more remarkable in terms of feeling control, a finding that deserves an attention. ( p<.05).

  • PDF

Modern Paper Quality Control

  • Olavi Komppa
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2000.06a
    • /
    • pp.16-23
    • /
    • 2000
  • The increasing functional needs of top-quality printing papers and packaging paperboards, and especially the rapid developments in electronic printing processes and various computer printers during past few years, set new targets and requirements for modern paper quality. Most of these paper grades of today have relatively high filler content, are moderately or heavily calendered , and have many coating layers for the best appearance and performance. In practice, this means that many of the traditional quality assurance methods, mostly designed to measure papers made of pure. native pulp only, can not reliably (or at all) be used to analyze or rank the quality of modern papers. Hence, introduction of new measurement techniques is necessary to assure and further develop the paper quality today and in the future. Paper formation , i.e. small scale (millimeter scale) variation of basis weight, is the most important quality parameter of paper-making due to its influence on practically all the other quality properties of paper. The ideal paper would be completely uniform so that the basis weight of each small point (area) measured would be the same. In practice, of course, this is not possible because there always exists relatively large local variations in paper. However, these small scale basis weight variations are the major reason for many other quality problems, including calender blacking uneven coating result, uneven printing result, etc. The traditionally used visual inspection or optical measurement of the paper does not give us a reliable understanding of the material variations in the paper because in modern paper making process the optical behavior of paper is strongly affected by using e.g. fillers, dye or coating colors. Futhermore, the opacity (optical density) of the paper is changed at different process stages like wet pressing and calendering. The greatest advantage of using beta transmission method to measure paper formation is that it can be very reliably calibrated to measure true basis weight variation of all kinds of paper and board, independently on sample basis weight or paper grade. This gives us the possibility to measure, compare and judge papers made of different raw materials, different color, or even to measure heavily calendered, coated or printed papers. Scientific research of paper physics has shown that the orientation of the top layer (paper surface) fibers of the sheet paly the key role in paper curling and cockling , causing the typical practical problems (paper jam) with modern fax and copy machines, electronic printing , etc. On the other hand, the fiber orientation at the surface and middle layer of the sheet controls the bending stiffness of paperboard . Therefore, a reliable measurement of paper surface fiber orientation gives us a magnificent tool to investigate and predict paper curling and coclking tendency, and provides the necessary information to finetune, the manufacturing process for optimum quality. many papers, especially heavily calendered and coated grades, do resist liquid and gas penetration very much, bing beyond the measurement range of the traditional instruments or resulting invonveniently long measuring time per sample . The increased surface hardness and use of filler minerals and mechanical pulp make a reliable, nonleaking sample contact to the measurement head a challenge of its own. Paper surface coating causes, as expected, a layer which has completely different permeability characteristics compared to the other layer of the sheet. The latest developments in sensor technologies have made it possible to reliably measure gas flow in well controlled conditions, allowing us to investigate the gas penetration of open structures, such as cigarette paper, tissue or sack paper, and in the low permeability range analyze even fully greaseproof papers, silicon papers, heavily coated papers and boards or even detect defects in barrier coatings ! Even nitrogen or helium may be used as the gas, giving us completely new possibilities to rank the products or to find correlation to critical process or converting parameters. All the modern paper machines include many on-line measuring instruments which are used to give the necessary information for automatic process control systems. hence, the reliability of this information obtained from different sensors is vital for good optimizing and process stability. If any of these on-line sensors do not operate perfectly ass planned (having even small measurement error or malfunction ), the process control will set the machine to operate away from the optimum , resulting loss of profit or eventual problems in quality or runnability. To assure optimum operation of the paper machines, a novel quality assurance policy for the on-line measurements has been developed, including control procedures utilizing traceable, accredited standards for the best reliability and performance.

Minimally invasive cardiac surgery with the partial mini-sternotomy in children (소아연령군에서의 부분흉골소절개를 통한 최소침투적심장수술)

  • 이정렬;임홍국;성숙환;김용진;노준량;서경필
    • Journal of Chest Surgery
    • /
    • v.31 no.5
    • /
    • pp.466-471
    • /
    • 1998
  • Purpose: The safety and efficacy of minimally invasive techniques in congenital heart surgery were tested in this study. Materal and method: Between July 1997 and November 1997, a total of 46 children were underwent minimally invasive cardiac operations at Seoul National University Children's Hospital. Age and body weight of the patients averaged 34.6${\pm}$41.8 (Range: 1∼148) months and 14.5${\pm}$9.9(Range: 3.0∼40.0) kg, respectively. Twenty eight patients were male. Preoperative surgical indications included 15 atrial septal defects, 25 ventricular septal defects, 1 foreign body in aorta, 3 partial atrioventricular septal defects, 1 total anomalous pulmonary venous connection(cardiac type), and 1 tetralogy of Fallot. After creating a small lower midline skin incision starting as down as possible from the sternal notch, a vertical midline sternotomy extended from xyphoid process to the level of the second intercostal space, where one of the T-, J-, I- or inverted C-shaped lower lying mini-sternotomy was completed with a creation of unilateral right or bilateral trap door sternal opening. A conventional direct aortic and bicaval cannulation was routine. Result: A mean length of skin incision was 6.1${\pm}$1.0(range: 4.0∼9.0) cm. A mean distance between the suprasternal notch and the upper most point of the skin incision was 4.0${\pm}$1.1 (range: 2.0∼7.0) cm. Mean cardiopulmonary bypass time, aortic cross-clamp time, and the operation time were 62.9${\pm}$20.0(range: 28∼147), 29.8${\pm}$12.8(range: 11∼79), and 161.1${\pm}$34.5 (range: 100-250) minutes. A mean total amount of postoperative blood transfusion was 71.0${\pm}$68.1 (range: 0∼267) cc. All patients were extubated mean 11.3${\pm}$13.8(range: 1∼73) hours after operation. A mean total amount of analgesics used was 0.8${\pm}$1.8(range: 0∼9) mg of morphine. The mean duration of stay in intensive care unit and hospital stay were 35.0${\pm}$32.2 (range: 10∼194) hours and 6.2${\pm}$2.0(range: 3∼11) days. There were no wound complications and hospital deaths. Conclusion: This short-term experience disclosed that the minimally invasive technique can be feasibly applied in a selected group of congenital heart disease as well as is cosmetically more attractive approach.

  • PDF

Histidine-tryptophan-ketoglutarate Versus Blood Cardioplegic Solutions: A Prospective, Myocardial Ultrastructural Study (선천성 심장기형의 수술 후 Histidine-tryptophan-ketoglutarate 심정지액과 혈성 심정지액의 전자현미경적 심근 구조의 비교 관찰)

  • Kim, Si-Ho;Lee, Young-Seok;Woo, Jong-Soo;Sung, Si-Chan;Choi, Pil-Jo;Cho, Gwang-Jo;Bang, Jung-Heui;Roh, Mee-Sook
    • Journal of Chest Surgery
    • /
    • v.40 no.1 s.270
    • /
    • pp.8-16
    • /
    • 2007
  • Background: We performed a prospective clinical study to evaluate the ultrastructural integrity of the myocardium after using Histidine-Tryptophan-Ketoglutarate (HTK) solution in comparison with blood cardioplegic solution during congenital heart surgery. Material and Method: Twenty two patients with acyanotic heart disease, who were scheduled for elective open heart surgery, were randomized into two groups. The HTK Group (n=11) received HTK cardioplegic solution; the blood group (n=11) received conventional blood cardioplegic solution during surgery. The preoperative diagnoses included ventricular septal defect (n=9) and atrial septal defect (n=2) in each group. A small biopsy specimen was taken from the right ventricle's myocardium, and this was processed for ultrastructural examination at the end of 30 minutes of reperfusion. Semiquantitative electron microscopy was carried out 'blindly' in 4 areas per specimen and in 5 test fields per area by 'random systematic sampling' and 'point and intersection counting'. The morphology of the mitochondrial membrane and cristae were then scored. The interstitial edema of the myocardium was also graded. Result: The semiquantitative score of the mitochondrial morphology was $19.65{\pm}4.75$ in the blood group and $25.25{\pm}5.85$ in the HTK group (p=0.03). 6 patients (54.5%) in the blood group and 3 patients (27.3%) in the HTK group were grade 3 or more for the interstitial edema of the myocardium. Conclusion: The ultrastructural integrity was preserved even better with HTK solution than with conventional blood cardioplegic solution.

Three Phases and Water Characteristics of Horticultural Substrates (원예(園藝) 상토재료(床土材料)의 삼상(三相)과 수분특성(水分特性))

  • Jo, In-Sang;Hyun, Byung-Keun;Cho, Hyun-Jun;Jang, Yong-Seon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.30 no.1
    • /
    • pp.56-61
    • /
    • 1997
  • A study was carried out to find out the basic information in physical properties for selection and manufacturing the good seedling media through the analysis of the physical properties, such as particle size, water retention and three phases of the major horticultural substrates. Easily available water(EAW), the water contents between 1kPa and 5kPa water potental, was highest in peatmoss with 39%, and perlite 34.0%, vermiculite 16.9%, but the values of osmunda and bark were lower than 4.8%. Water buffering capacity(WBC), the water content between 5kPa and 10kPa, was 6.1% in peatmoss and 2.3% in vermiculite but it was lower than 1.0% in other substrates. To adjust the suitable range of water potential at crossing point of water and air curves to 1.5~2.5kPa, more finer materials were needed in osmunda and bark, and more coarser materials must be added to peatmoss, perlite and vermiculite. Water potentials of substrates in saturated pot condition were equivalent to 2.2kPa in peatmoss and others were ranged in 1.0kPa to 4.3kPa of water potential in pressure chamber.

  • PDF

Solar Module with a Glass Surface of AG (Anti-Glare) Structure (연요철(Anti-Glare) 구조의 표면 유리 기판을 가지는 고효율 태양전지 모듈)

  • Kong, Dae-Young;Kim, Dong-Hyun;Yun, Sung-Ho;Bae, Young-Ho;Yu, In-Sik;Cho, Chan-Seob;Lee, Jong-Hyun
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.3
    • /
    • pp.233-241
    • /
    • 2011
  • Currently, solar module is using the two methods such as a glass-filled method or a super-straight method. The common point of these methods is to use glass structure on the front of solar module. However, the reflectance of the solar module is high depending on the height of the incident sunlight due to the flat surface of the module front glass. Purposed to solve these problems, AG (anti-glare) structures were formed on the glass surface. Next is fabrication methods of AG structure. First, uneven structure made by micro blaster equipment was dipped in Hydro-fluidic acid (HF) acid. HF acid process was carried out to remove particles and to make high transmittance. The reflectance and transmittance of the anti-glare glass was compared to those of the bare glass. The reflectance of anti-glare glass decreased approximately 1% compared with bare glass. The transmittance of anti-glare glass was similar to bare glass. According to the sample angle, the difference of the reflectance between bare glass and the anti-glare glass was about 19%. Isc and efficiency value of anti-glare glass on bare solar cell appeared about 3.01 mA and 0.228% difference compared with bare glass. Anti-glare glass on textured solar cell appeared about 9.46 mA and 0.741% difference compared with bare glass. As a result, the role of anti-glare in the substrate is to reduces the loss of sunlight reflected from the surface. In this study, therefore, AG structure on the solar cell was used to improve the efficiency of solar cell.

Characteristics of Si Floating Gate Nonvolatile Memory Based on Schottky Barrier Tunneling Transistor (쇼트키 장벽 관통 트랜지스터 구조를 적용한 실리콘 나노점 부유 게이트 비휘발성 메모리 특성)

  • Son, Dae-Ho;Kim, Eun-Kyeom;Kim, Jeong-Ho;Lee, Kyung-Su;Yim, Tae-Kyung;An, Seung-Man;Won, Sung-Hwan;Sok, Jung-Hyun;Hong, Wan-Shick;Kim, Tae-You;Jang, Moon-Gyu;Park, Kyoung-Wan
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.302-309
    • /
    • 2009
  • We fabricated a Si nano floating gate memory with Schottky barrier tunneling transistor structure. The device was consisted of Schottky barriers of Er-silicide at source/drain and Si nanoclusters in the gate stack formed by LPCVD-digital gas feeding method. Transistor operations due to the Schottky barrier tunneling were observed under small gate bias < 2V. The nonvolatile memory properties were investigated by measuring the threshold voltage shift along the gate bias voltage and time. We obtained the 10/50 mseconds for write/erase times and the memory window of $\sim5V$ under ${\pm}20\;V$ write/erase voltages. However, the memory window decreased to 0.4V after 104seconds, which was attributed to the Er-related defects in the tunneling oxide layer. Good write/erase endurance was maintained until $10^3$ write/erase times. However, the threshold voltages moved upward, and the memory window became small after more write/erase operations. Defects in the LPCVD control oxide were discussed for the endurance results. The experimental results point to the possibility of a Si nano floating gate memory with Schottky barrier tunneling transistor structure for Si nanoscale nonvolatile memory device.

Experimental Comparison and Analysis of Measurement Results Using Various Flow Meters (유량측정 기기별 측정성과에 대한 실험적 비교분석)

  • Lee, Jae-Hyug;Lee, Suk-Ho;Jung, Sung-Won;Kim, Tae-Woong
    • Journal of Wetlands Research
    • /
    • v.12 no.1
    • /
    • pp.95-103
    • /
    • 2010
  • Discharge data examine the process of hydrologic cycle and used significantly in water resource planning and irrigation and flood control planning. However, it needs lots of time and money to get the discharge data. So discharge rating curve is usually used in converting discharge data. Therefore reliability of discharge rating curve absolutely depends on quality of discharge data. Many engineers who study hydrologic engineering make high quality discharge data to develop reliable discharge rating curve. And they carry out research on standard and method of discharge measurement, and equipment improvement. Now various flow meters are utilized to make discharge data in Korea. However, accuracy of equipment and experimental research data from measurement are not enough. In this paper, constant discharge flowed through standard concrete channel, and the velocity is measured using various flow meters. Also Discharge is calculated by measured data to compare and analyze. The equipment for the experiment is Price AA(USGS Type AA Current meter), flow meter, ADC, C2 small current meter, flow tracker, Electromagnetic current meter. The discharge got form various flow meters which are widely used for discharge measurement. The various depths of water were examined and compared such as 0.30 m, 0.35 m, 0.40 m, 0.45 m, 0.50 m, 0.55 m. The experiment progresses a round-measurement on 6-case. Wading measurement(one point method : the 60 % height in surface of the water) was applied to improve creditability and accuracy among measurement methods. USGS Type AA current Meter, Flow Meter, ADC, C2 Small Current meter got the certificate of quality guaranteed. So the results of experiment were used to compare discharge. The Results showed the difference based on USGS Type AA current Meter at average discharge and velocity. Electromagnetic current meter made differences over $\pm$ 10 % and Flow Meter made differences under $\pm$ 10 %. Also ADC, Flow Meter, C2 Small Current meter made differences under $\pm$ 5 %.

Clinical Usefulness of Contrast Echocardiography: The Dose Effect for Left Ventricle Visualization in Dogs (심초음파의 조영제의 임상적 유용성: 개에서 좌심영상화에 대한 조영제 용량의 영향)

  • Shin, Chang-ho;Hwang, Tae-sung;Yoon, Young-min;Jung, Dong-in;Yeon, Seong-chan;Lee, Hee-chun
    • Journal of Veterinary Clinics
    • /
    • v.32 no.6
    • /
    • pp.486-490
    • /
    • 2015
  • Two-demensional echocardiography is routinely used for evaluation of cardiac function. Visualization of the endocardial border is essential for the assessment of global and regional left ventricular with cardiac disease. SonoVue$^{TM}$ is a microbubble contrast agent that consists of sulfur hexafluoride-filled microbubbles in a phospholipid shell. There were many studies about contrast echocardiographic examination using SonoVue$^{TM}$ contrast agent, and various doses of SonoVue$^{TM}$ were used. To our knowledge, in published veterinary medicine, there was not reported for diagnostic efficient dose of SonoVue$^{TM}$ to evaluate contrast enhanced left ventricular endocardial border delineation (LVEBD). The purpose of this study is to compare the visualization time of LVEBD and find efficient dose of SonoVue$^{TM}$ for using various doses in dogs. Ten healthy Beagles were recruited to the study. Three different doses (0.03 ml/kg, 0.05 ml/kg and 0.1 ml/kg) of SonoVue$^{TM}$ were injected. Endocardial segments were assigned based on previously established methodology, where by the four-chamber views of the LV were divided into 6 segments. In this study, Contrast enhancement of the LVEBD after each injection was evaluated visually at the time point of overall contrast enhancement (Segmental scoring 5+) in the LV by three investigators in a blind manner. Statistical analysis was performed with SPSS version 14.0. All data were analyzed using one-way ANOVA, the multiple comparison Scheffe test. When data for the three offsite readers were combined, mean durations of useful contrast were $3.54({\pm}2.14)$, $6.15({\pm}2.61)$, and $24.39({\pm}11.10)$ seconds for the 0.03 ml/kg, 0.05 ml/kg, and 0.1 ml/kg SonoVue$^{TM}$ doses, respectively. After injection of contrast agent, there were no significant change in side effects such as urticaria, angioedema, hypersensitivity reactions, and digestive system disorders. This study suggests that efficient dose of SonoVue$^{TM}$ contrast agent for improvement of the left ventricle visualization is 0.1 ml/kg. The duration of useful enhancement of LVEBD and the reproducibility were also the highest at the 0.1 ml/kg dosage.