• Title/Summary/Keyword: Plotting

Search Result 366, Processing Time 0.026 seconds

Flood Frequency Analysis by Wakeby and Kappa Distributions Using L-Moments (Wakeby 및 Kappa 분포의 L-모멘트법에 의한 홍수빈도분석)

  • Maeng, Seung-Jin;Lee, Soon-Hyuk;Lee, Hyeon-Gyu;Ryu, Kyong-Sik;Song, Gi-Heon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.48 no.5
    • /
    • pp.17-27
    • /
    • 2006
  • The objective of this study is to induce the design floods by the methodology of L-moment including test of homogeneity, independence and outlier of the data of annual maximum flood flows for 12 water level gaging stations of South Korea. To select appropriate distribution of the data for annual maximum flood flows, the distributions of Wakeby and Kappa are applied and the appropriateness is judged by Kolmogorov-smirnov (K-S) test. The parameters of selected Wakeby and Kappa distributions are calculated by the method of L-moment and the design floods are induced. Through the comparative analysis using the relative root mean square errors (RRMSE) and relative absolute errors (RAE) of design floods, the result shows that the design floods by Wakeby distribution are closer to the observed data than those obtained by the Kappa distribution.

Computer-Aided Design of Plow Working Surfaces (플라우 작업 곡면의 컴퓨터 원용 설계)

  • Chung, C.J.;Park, J.S.;Woo, S.H.
    • Journal of Biosystems Engineering
    • /
    • v.17 no.1
    • /
    • pp.37-44
    • /
    • 1992
  • This study was intended to develop the design program of the working surface of moldboard-plow by use of the computer-aided design. The mathematical model of the working surfaces of moldboard-plows by use of computer graphics was developed and plotted in two dimension on three major planes. The surfaces of moldboard-plows were represented with "B-spline surface fitting" by selecting the twenty-five three-dimensional data that could well describe the working surface of moldboard-plow. The shape of moldboard-plow on three major planes was drawn for varied design parameters. The representation of the mathematical model for the working surfaces of various types of moldboard-plows was manipulated by translation, rotation and scaling about arbitrary axes in space. By using three-dimensional graphics techique to describe moldboard-plows, it was capable of plotting the three-dimensional shape of moldboard-plow easily and quickly in comparison with the existing design methods that were difficult to grasp the shape of moldboard-plow as a whole. The design theories of moldboard plow and three-dimensional computer graphic technique were applied to find out the improved reversible Jaenggi bottom. It was resulted in the newly developed shape of Jaenggi which may be used for improving the performance compared to existing ones.

  • PDF

Real-Time Visualization Techniques for Sensor Array Patterns Using PCA and Sammon Mapping Analysis (PCA와 Sammon Mapping 분석을 통한 센서 어레이 패턴들의 실시간 가시화 방법)

  • Byun, Hyung-Gi;Choi, Jang-Sik
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.99-104
    • /
    • 2014
  • Sensor arrays based on chemical sensors produce multidimensional patterns of data that may be used discriminate between different chemicals. For the human observer, visualization of multidimensional data is difficult, since the eye and brain process visual information in two or three dimensions. To devise a simple means of data inspection from the response of sensor arrays, PCA (Principal Component Analysis) or Sammon's nonlinear mapping technique can be applied. The PCA, which is a well-known statistical method and widely used in data analysis, has disadvantages including data distortion and the axes for plotting the dimensionally reduced data have no physical meaning in terms of how different one cluster is from another. In this paper, we have investigated two techniques and proposed a combination technique of PCA and nonlinear Sammom mapping for visualization of multidimensional patterns to two dimensions using data sets from odor sensing system. We conclude the combination technique has shown more advantages comparing with the PCA and Sammon nonlinear technique individually.

Kinetics of water vapor adsorption by vacuum-dried jujube powder

  • Lee, Jun Ho;Zuo, Li
    • Food Science and Preservation
    • /
    • v.24 no.4
    • /
    • pp.505-509
    • /
    • 2017
  • Water vapor adsorption kinetics of vacuum-dried jujube powder were investigated in temperature and relative humidity ranges of 10 to $40^{\circ}C$ and 32 to 75%, respectively. Water vapor was initially adsorbed rapidly and then reached equilibrium condition slowly. Reaction rate constant for water vapor adsorption of vacuum-dried jujube powder increased with an increase in temperature. The temperature dependency of water activity followed the Clausius-Clapeyron equation. The net isosteric heat of sorption increased with an increase in water activity. Good straight lines were obtained with plotting of $1/(m-m_0)$ vs. 1/t. It was found that water vapor adsorption kinetics of vacuum-dried jujube powder was accurately described by a simple empirical model, and temperature dependency of the reaction rate constant followed the Arrhenius-type equation. The activation energy ranged from 50.90 to 56.00 kJ/mol depending on relative humidity. Arrhenius kinetic parameters ($E_a$ and $k_0$) for water vapor adsorption by vacuum-dried jujube powder showed an effect between the parameters with the isokinetic temperature of 302.51 K. The information on water vapor adsorption kinetics of vacuum-dried jujube powder can be used to establish the optimum condition for storage and processing of jujube.

The Characteristic Curves of Commercial Medical X-ray Films (상용 의학용 X-ray 필름의 특성곡선)

  • Heo, Hoon;Jeong, Yeon-Tae;Lee, Jae-Sung
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.19 no.2
    • /
    • pp.12-21
    • /
    • 2001
  • For the purpose of determining characteristics of widely used commercial medical x-ray films, which are used for obtaining the Linac-grams for radiational treatment of cancers, we placed several commercial x-ray films at a fixed distance form the linear accelerator. After varying the exposed amount of radiation step by step, we could obtain a continually increasing density image for each film whose densities were determined by microdensitometer readings. The characteristic curves of the films were obtained by plotting the densities vs. the exposed radiation amounts, and their ${\gamma}$ values were determined. These values can be used to suggest a minimum necessary amount of exposed radiation to get a useful Linac-gram. The measured ${\gamma}$ values of the characteristic curves of the Kodak-DVP/RA-1 film were 1.73 when used 6MV x-ray, 1.70 when used 15MV of intensity. For the Konica-AX film, ${\gamma}$ values were 1.29 and 1.18 respectively. The result suggests that the effective conditions for high resolution of a L-gram be 6 MV of x-ray intensity and about 3 rad of exposed dose on a Kodak-DVP/RA-1 film.

  • PDF

Substituent Effects on the Wallach Rearrangement of 4'-Halogenated Azoxybenzenes in Conc. Sulfuric Acid : Reaction Mechanism and Linear Free Energy Relationship (황산 수용액내에서 4'-Halogenated Azoxybenzenes의 Wallach Rearrangement 반응에 대한 치환체효과 : 반응메카니즘과 Linear Free Energy Relationship)

  • Keum Sam-Rok;Lee Hyo-Il
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.1
    • /
    • pp.148-153
    • /
    • 1993
  • The Wallach rearrangement of 4'-halogenated azoxybenzenes in strong sulfuric acid was reinvestigated by UV-Vis spectrophotometric method. Interestingly an excellent linearity $(logk_{obs}=-0.61\;{\sigma}_R{^+} -3.29,\;{\gamma = 0.998)$ was obtained on plotting log (rate) vs. substituent constant, ${\sigma}_R{^+}$, which is known as the Pi delocalization parameter. Thus B-H mechanism via a charged intermediate $(DC^{++})$, which can be largely stabilized by resonance, is far more favored for the Wallach rearrangement.

  • PDF

An Acoustic Study of Relative Articulatory Positions of English Vowels and Korean Vowels

  • Ahn, Soo-Woong
    • Speech Sciences
    • /
    • v.8 no.4
    • /
    • pp.171-184
    • /
    • 2001
  • American English vowels and Korean vowels were compared by the plotformant method. For American English vowels, six General American English speakers pronounced English words in the b_t environment. For Korean vowels eight Kyongsang dialect speakers and eight Seoul dialect speakers pronounced Korean words in the environments of k_t, p_t and t_t. The formant plots were obtained by plotting F1/F2 tokens of 13 American English vowels on the F1xF2 plane. In spite of personal variations the 13 vowel spaces of all six American English speakers maintained their relative positions with some overlaps. Clear distinctions were made between i-I, e-$\varepsilon$, u-$\sigma$, and o-c. The domain of c and $\alpha$ overlapped for three American English speakers, but it did not for three other speakers. The 8 Korean vowel spaces of Kyongsang dialect speakers and Seoul dialect speakers were very similar and maintained their relative positions. No distinction was made between e and $\varepsilon$. In contrast with American English e which is a neutral vowel, Korean e was a back vowel. The comparison of 13 American English vowel positions and 8 Korean Vowel positions is expected to shed some light on the errors of English vowel pronunciation of Korean learners.

  • PDF

Multi-Dimension Scaling as an exploratory tool in the analysis of an immersed membrane bioreactor

  • Bick, A.;Yang, F.;Shandalov, S.;Raveh, A.;Oron, G.
    • Membrane and Water Treatment
    • /
    • v.2 no.2
    • /
    • pp.105-119
    • /
    • 2011
  • This study presents the tests of an Immersed Membrane BioReactor (IMBR) equipped with a draft tube and focuses on the influence of hydrodynamic conditions on membrane fouling in a pilot-scale using a hollow fiber membrane module of ZW-10 under ambient conditions. In this system, the cross-flow velocities across the membrane surface were induced by a cylindrical draft-tube. The relationship between cross-flow velocity and aeration strength and the influence of the cross-flow on fouling rate (under various hydrodynamic conditions) were investigated using Multi-Dimension Scaling (MDS) analysis. MDS technique is especially suitable for samples with many variables and has relatively few observations, as the data about Membrane Bio-Reactor (MBR) often is. Observations and variables are analyzed simultaneously. According to the results, a specialized form of MDS, CoPlot enables presentation of the results in a two dimensional space and when plotting variables ratio (output/input) rather than original data the efficient units can be visualized clearly. The results indicate that: (i) aeration plays an important role in IMBR performance; (ii) implementing the MDS approach with reference to the variables ratio is consequently useful to characterize performance changes for data classification.

A Design of a Full FPGA-based DC-motor Control and Monitoring System (Full FPGA 기반 DC 모터 제어 및 모니터링 시스템 설계)

  • Lim, Byung Gyu;Kang, Moon Ho
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.11
    • /
    • pp.211-220
    • /
    • 2014
  • In this paper a full FPGA-based and compact motor-control system is shown that makes it easy to control the motor and analyze the result data in real time with embedding not only a DC motor controller but also a TFT LCD interface in a single FPGA. Both a PID speed control module for a DC motor and a monitoring module for plotting real time graphs on to a TFT LCD are designed in a single FPGA, and the system validity is shown through simulation and experimental results. The FPGA used is xc3s400 and the entire system is designed by using the AD (Altium Designer). A PWM motor drive system is constructed by using MOSFETs for a DC motor 4-quadrant operations.

A study on the flume for a current meter rating (유속계 검정용수로에 관한 연구)

  • 정준석;박정응
    • Water for future
    • /
    • v.6 no.2
    • /
    • pp.30-37
    • /
    • 1973
  • The coefficient of the current meter generally determined by the maker Its coefficient is subject to being changed with time. Therefore the coefficient of the current meter has to be checked up before it is ready to be used Such an inspection is termed a current meter rating The current meter equipped an electronic apparatus and all the others are to be rated in a rating flume. The price current meter which is most widely used for measuring flow velocities ranging between 0.3m/sec and 3.5m/sec has been used in this study. The length of the flume and the optimum range of the rating in the cross section are determined in the range of 20∼120cm deep, 50∼160cm wide of the flume. In this study, the 23 different kinds of the current meter rating enabled us to determine the constants a and b of the following equation. V=an+b(m/sec) where, n is number of revolution per second(n=N/T) V is velocity(v=D/T) The above constant can be determined by the least squares method and plotting, using the velocity(V=D/T) and the number of revolution per second(n=N/T) obtained from the running distance(D), time(T), the number of revolutin(N), and the running number(m). From the experiments the following conclusions are drawn: 1) The rating flume is large enough if the flume is 110∼120cm deep, and 40∼50m long. 2) The optimum depth for rating of a current meter is in the range of h=40∼50cm.

  • PDF