• Title/Summary/Keyword: Plotting

Search Result 364, Processing Time 0.026 seconds

In-situ Self-calibration of Non-metric Camera and Digital Stereo Plotting for Public Survey (공공측량 적용을 위한 비측정용 카메라의 현장자체검정 및 수치 입체 도화)

  • Seo, Sang-Il;Lee, Byoungkil
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.35 no.3
    • /
    • pp.145-154
    • /
    • 2017
  • In recent years, demand for 1 / 1,000 digital map production has increased in various fields such as construction and urban planning. As a result, the use of low-cost non-metric cameras that replace expensive aerial photogrammetry equipment is required. In Korea, researches are being continuously carried out to produce a large scale digital map by photographing a small target area with a non-metric camera. However, due to the limitation of the accuracy of the non-metric camera, it is difficult to do digital mapping with stereoscopic photographs. In this study, we tried to verify the possibility of large-scale digital mapping to utilize non-metric camera for public survey. For this purpose, the accuracy of the digital mapping results of the non-metric camera and the results of the DMC camera were compared and analyzed. After performing in-situ self-calibration including 8 standard additional parameters, we plotted to a scale of 1/1,000 and confirmed that the RMSE is suitable for public survey accuracy of ${\pm}0.145m$ in horizontal and ${\pm}0.153$ m in vertical.

Evaluation of Possibility of Large-scale Digital Map through Precision Sensor Modeling of UAV (무인항공기 정밀 센서모델링을 통한 대축척 수치도화 가능성 평가)

  • Lim, Pyung-chae;Kim, Han-gyeol;Park, Jimin;Rhee, Sooahm
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.6_1
    • /
    • pp.1393-1405
    • /
    • 2020
  • UAV (Unmanned Aerial Vehicle) can acquire high-resolution images due to low-altitude flight, and it can be photographed at any time. Therefore, the UAV images can be updated at any time in map production. Due to these advantages, studies on the possibility of producing large-scale digital maps using UAV images are actively being conducted. Precise digital maps can be used as base data for digital twins or smart cites. For producing a precise digital map, precise sensor modeling using GCPs (Ground Control Points) must be preceded. In this study, geometric models of UAV images were established through a precision sensor modeling algorithm developed in house. Then, a digital map by stereo plotting was produced to evaluate the possibility of large-scale digital map. For this study, images and GCPs were acquired for Ganseok-dong, Incheon and Yeouido, Seoul. As a result of precision sensor modeling accuracy analysis, high accuracy was confirmed within 3 pixels of the average error of the checkpoints and 4 pixels of the RMSE was confirmed for the two study regions. As a result of the mapping accuracy analysis, it satisfied the 1:1,000 mapping accuracy announced by the NGII (National Geographic information Institute). Therefore, the precision sensor modeling technology suggested the possibility of producing a 1:1,000 large-scale digital map by UAV images.

Coordinates Determination of tow Level Control Point by Aerial Triangulation (사진기준점측량을 이용한 저등급 기준점의 좌표결정)

  • 최재화;이석배;최윤수
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.6 no.2
    • /
    • pp.34-41
    • /
    • 1988
  • Nowadays the considerable improvements, not only in photogrammetric equipment but also in adjustment methods have led to a high accuracy of Aerial Triangulation and reach the step to obtain A.T. technique that uses Global Position System without ground control survery. The enterance of analytical plotter have made considerable development both in accuracy and in efficiency and improved working environment of A.T. by the combination of On-Line Analytical Plotting System. In this paper, in A.T., with using of analytical polotter, aims to improve the acccuracy in coordinates determination of low level control point. The result shows that in case of A.T. with analytical plotter AVIOLYT BC2, the accuracy of control points improves to 7% in planimetry and to 40% in height compared to A.T. with precision plotter Autograph A-8.

  • PDF

Design and Research for Intelligent Typhoon Evasion System for Ships

  • Wang, Jing-Quan;He, Yi;Shi, Ping-An;Peng, Xiao-Hong;Xu, Zu-Yuan;Qin, Shan-Ci;Li, Qing-Lie;Ding, Bing-Lin
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2001.10a
    • /
    • pp.177-186
    • /
    • 2001
  • Based upon the previous experiences and typical oases of typhoon evasion fur ships as well as tile achievement in scientific research in this detrain, we developed the Intelligent Typhoon Evasion System for Ships. It consists of five subsystems, including electronic charts, ship movement management, typhoon information query and automatic plotting, real-time calculation of ship-typhoon situation, intelligent typhoon evasion decision making. With the synthetical application of analogy theory, synoptic chart, satellite cloud picture analysis, typhoon digital forecast and other relevant technologies, we leave established the typhoon evasion data bases. model bases and knowledge bases, which make it possible to automatically track the ships and typhoon paths. The system can realize ship-typhoon situation analysis, risk levee assessment, typhoon paths correction and course synoptic forecast, and intelligent typhoon evasion decision making.

  • PDF

Analysis of Cationic Surfactants in Cosmetics By Reverse phase Ion-Pair Chromatigraphy with Suressed Conductivity Detector and UV Detector

  • Jong-Keun Choi;Jae
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.23 no.3
    • /
    • pp.161-167
    • /
    • 1997
  • Determination of several cationic surfactants in cosmetics has been investigated. Reverse phase ion pair chromatography was used to identify and quantitate cationic surfactants. Cationic surfactants analyzed in this experiment were cetylpyridium chloride, stearyltrimetylammonium chloride, bezalkonium chloride, benzyldicethylcetylammonium chloride, and bihenyltrimethyl ammonium chloride. The separation was achieved on a reverse phase coumn with 10mM HCl-acetonitrile eluent. In this condition, the most of cationic surfactants with exception of CPC and CTAC respectively with suppressed conductivity detector and UV detector connected in series. The calibration curves obtained by plotting the peak areas of the cationic surfactants were linear at levels ranging from 0.005 to 0.1% correlation coefficient, r=0.9988. The detection limits were 1 to 5ppm in sample solution. The average recoveries of cationic surfactants added to hair treatment cream and hair rinse in three to five experiments were 96.7 105.2% and relative standard deviations were 1.1-3.8%. The case that there were CPC and CTAC in same solution was also tested. CPC and CTAC which couldn't be separated on reverse phase column were quantitated with suppressed conductivity detector and UV detector connected in series. Recovery of CPC and CTAC were 101.6 and 89.2% respectively. The proposed method was applied to the determination of cationic surfactants in commercial hair treatment cream.

  • PDF

A Study on the Ozone Control Strategy using the OZIPR in the Seoul Metropolitan Area

  • Jin, Lan;Lee, Sun-Hwa;Shin, Hye-Jung;Kim, Yong-Pyo
    • Asian Journal of Atmospheric Environment
    • /
    • v.6 no.2
    • /
    • pp.111-117
    • /
    • 2012
  • To establish area specific control strategy for ambient ozone in the Seoul Metropolitan Area (SMA), the maximum ozone concentration in each local government district in the SMA were estimated by using the OZone Isopleth Plotting Package for Research (OZIPR) model. The modeling period was June 2000 and the emission inventory data used were from National Institute of Environmental Research (NIER). Except the islands of Incheon, whole Seoul and Incheon areas were volatile organic compounds (VOCs) limited, i.e., decreasing the oxides of nitrogen ($NO_X$) emission alone may increase the maximum ozone concentration upto certain point. In Gyeonggi, 12 areas were VOCs limited while 12 areas were in between VOCs limited and $NO_X$ limited, i.e., decreasing both $NO_X$ and VOCs emission may decrease the maximum ozone concentration. Majority of the estimated ozone values were lower than the measured values. The reason could be inaccuracy in emission inventories and/or transport from other areas. The same calculation was carried out for June 2004 and it was found that Seoul was still in the VOCs limited condition.

Collision Risk Analysis in Busan Harbour

  • Gug, Seung-Gi;Fukuda, Gen;Cho, A-Ra;Park, Hye-Ri
    • Journal of Navigation and Port Research
    • /
    • v.38 no.1
    • /
    • pp.53-57
    • /
    • 2014
  • This thesis, concentrates on marine collision risks of the area divided by cells. Using a gas molecular collision calculation model, a collision risk model is proposed. Collision risk is estimated by relative angle, relative speed, and ship's density in the cell. For one week, Automatic Identification System (AIS) data was collected and analyzed on the Busan North Port area. The results indicate a high-risk area at the sea route connection point in Busan North Port. It also shows that twilight is the time of day when most collisions occur. This means that the area is high risk due to the number of collisions and other dangerous factors related to twilight. Although there is still need to consider other risks such as grounding risks, the results of this study are useful to for plotting a risk map for the port.

Analysis of Efficiency of Bacillus subtilis To Treat Bagasse Based Paper and Pulp Industry Wastewater-A Novel Approach

  • Karichappan, Thirugnanasambandham;Venkatachalam, Sivakumar;Jeganathan, Prakash Maran
    • Journal of the Korean Chemical Society
    • /
    • v.58 no.2
    • /
    • pp.198-204
    • /
    • 2014
  • In this present study, bagasse based pulp and paper industry wastewater was treated under different operating conditions such as initial pH (6-8), temperature ($25-35^{\circ}C$) and contact time (3-7 days) by using Bacillus subtilis. Response surface methodology (RSM) coupled with Box-Behnken response surface design (BBD) was employed to investigate the effect of process variables on the responses such as turbidity, biological oxygen demand (BOD) and chemical oxygen demand (COD) removal. The experimental data were analyzed by Pareto analysis of variance (ANOVA) and the second order polynomial models were developed. Interactive effects of the process variables on the responses were studied using plotting 3D response surface contour graph and the optimum process conditions were found to be: initial pH of 7, temperature of $30^{\circ}C$ and contact time of 5 days. Under these conditions, removal efficiencies of turbidity, BOD and COD were found to be 85%, 93% and 80% respectively which are close agreement with real experiments. These results indicate that the treatment of bagasse based pulp and paper industry wastewater using Bacillus subtilis is an effective and novel technique.

BIACORE 바이오센서를 이용한 B형 간염 표면항원 정량분석의 기초연구

  • Yu, Chang-Hun;Ryu, Gang;Jeon, Jun-Yeong;Lee, Hyeon-Ik;Choe, Seong-Cheol;Lee, Eun-Gyu
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.231-234
    • /
    • 2001
  • We performed a basic experiment for rapid. on-line, real-time measurement of HBsAg by using a BIACORE biosensor, a chip-based sensor utilizing surface plasmon resonance technology to quantify the recognition and interaction of biomolecules. We immobilized an a -HBsAg antibody on a CM5 chip surface which was activated by N-hydroxysuccinimide for amine coupling with HBsAg, and measured the mass increase from the coupling. This study showed the potential of this biosensor-based method as a rapid, multi-sample, on-line assay. Once properly validated, it can serve as a more powerful method for HBsAg quantification.

  • PDF

The Study of Pretreated GE-132 on the Hepatic Glutathione S-Transferase Activity in Rat (유기게르마늄(GE-132) 이 Glutathone S-Transferase활성에 미치는 영향)

  • Kim, Seok-Hwan;Park, Eun-Sook;Jo, Tae-Hyun;Choi, Jong-Won
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.23 no.4
    • /
    • pp.581-586
    • /
    • 1994
  • The study was initiated elucidate the mechanism by examining the effect of GE-132 on hepatic glutathione S-transferase (GST) activity. Activity of GST increased with dose-dependent manner in hepatic cytosolic fraction of GE-132 treatment rats. Double reciprocal plotting gave Vmax value 1.4 fold increase by the treatment of GE-132(100mg/kg, p.o.for 6 weeks) compared with control group, but did not change Km value. Ethacryinc acid (85mg/kg, once a day, i.p) was injected to control rat, the GST activity decreased remarkably . However, GE-132 pretreated group, the effect caused by ethacrynic acid was markedly reduced. And activity of ${\gamma}$-glutamylcys- teine synthetase was not changed either by GE-132 treatment , but the activity of glutathione reudctase increased significantly. Decreasing properties of ethacrynic acid decreased level of hepatic glutathione , which was restored to same degree by GE -132 pretreatment . GE-132 protective effect on ethacrynic acid-induced mortality. It is concluded that the efect of GE-132 is partly mediated by increase in hepatic GST activity.

  • PDF