• 제목/요약/키워드: Plating technique

검색결과 152건 처리시간 0.021초

Performance Evaluation of Ti-Al-N coated Endmill by Arc ton Plating (아크이온플레이팅에 의한 Ti-Al-N코팅 엔드밀의 성능평가)

  • 이상용;강명창;김정석;김광호
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 한국공작기계학회 2002년도 춘계학술대회 논문집
    • /
    • pp.251-254
    • /
    • 2002
  • The technique of high speed machining is widely studied in machining field. In this study, TiAIN single-layered and TiAIN/TiN double-layered coatings were applied to end-mill by an arc ion plating technique. Their performances were comparatively studied about cutting force, tool wear, tool life and surface roughness of workpiece under high speed cutting conditions. The TiAIN single-layer coated tool showed higher wear-resistance due to its higher hardness, while the TiAIN/TiN double-layer coated tool showed better performance for high metal removal, i.e., high fled per tooth condition due to its higher toughness. The surface roughness of the workpiece was not influenced by the wear amount of coated tools.

  • PDF

A Study on Fabrication of Conductor Patterns on AlN Ceramic Surface by Laser Direct Writing (레이저 직접묘화법에 의한 AlN 기판상의 전도성 패턴 제작에 관한 연구)

  • Lee, Je-Hoon;Seo, Jung;Han, Yu-Hee
    • Laser Solutions
    • /
    • 제3권2호
    • /
    • pp.25-33
    • /
    • 2000
  • One of perspective direction of microfabrication is direct laser writing technology that allows to create metal, semiconductive and dielectric micropatterns on substrate surface. In this work, a two step method, the combination of seed forming process, in which metallic Al seed was selectively generated on AlN ceramic substrate by direct writing technique using a pulsed Nd : YAG laser and subsequent electroless Ni plating on the activated Al seed, was presented. The effects of laser parameters such as pulse energy, scanning speed and pulse frequency on shape of Alseed and conductor line after electroless Ni plating were investigated. The nature of the laser activated surface is analyzed from XPS data. The line width of this metallic Al and Ni is analyzed using SEM. As a results, Al seed line with 24㎛ width and 100㎛ isolated line space is obtained. Finally, laser direct writing can be applied in the field between thin and thick film technique in electronic industry.

  • PDF

Plating Technique for Cellulase Mutants of Trichoderma viride (Trichoderma viride 변이균주 분리를 위한 Cellulase Semiquantitative Plate Assay)

  • 현형환;백형석;이인복;이세영
    • Microbiology and Biotechnology Letters
    • /
    • 제6권3호
    • /
    • pp.129-133
    • /
    • 1978
  • A plating technique was devised to screen for high producing cellulase mutants of Trichoderma viride. The method employs: 1) The use of deoxycholate to limit colony size and 2) saponin to enhance cellulase detection in combiantion with rice straw pulp and pure cellulose on agar plate. The method will be used to isolate constitutive cellulase mutants of Trichoderma viride and should prove useful for isolating high producing mutants from a range of organisms.

  • PDF

Anterior inferior reconstruction plate on acute midshaft clavicle fvacture (쇄골 간부골절의 전하방 부착 재구성 금속판을 이용한 치료)

  • Kang, Jae-Do;Kim, Kwang-Ryul;Kim, Hyung-Chun;Lim, Moon-Sup;Kim, Seong-Hoon;Kweon, Jun-Hyung
    • Clinics in Shoulder and Elbow
    • /
    • 제6권1호
    • /
    • pp.44-49
    • /
    • 2003
  • Purpose: Many different operative technique of mid-shaft clavicle fracture have been reported. The aim of this prospective study was to compare the results of anterior or anterior-inferior plating with superior plating on the acute mid-shaft fracture of clavicle Materials and Methods: From February1997 to February 2002, thirty-eight consecutive open reduction and internal fixation with reconstruction plates were performed in thirty-eight patients. from August 1999, anterior or anterior-inferior plating was mainly used, prospectively. The duration of follow-up averaged 17 months (range,23 to 43 months). The mean age was 38 years old (range,21 to 57 years old) on anterior or anterior-inferior plating group and 35 years old (range,24 to 55 years old) on superior plating group. The physician progress note, VAS patient complement score, Roentgenogram and ASES score was evaluated. Results: Four patients were lost to follow-up. There was no statistical difference on mean radiological bone union time (8.7 weeks vs. 8.6 weeks) and ASES score (92 vs 94) at inferior and superior plating groups (P > 0.05). VAS patient complement score was very good or excellent on anterior or anterior-inferior group, average score was 1.1 (ranger,0 to 2) compare with superior plating group (P < 0.05). There were two cases of infection, 1 case of failed fixation on superior plating group and 1 case of delayed union on anterior inferior plating group. Conclusion: Anterior inferior plating on acute clavicle midshaft fracture results in excellent patient complement score compare with conventional superior reconstruction plate.

CLINICAL EVALUATION OF TREATMENT OUTCOME OF PLATING TECHNIQUE OF FIXATION FOR MANDIBULAR CONDYLAR FRACTURE (하악 과두 골절의 관혈적 정복시 고정 방법에 따른 임상적 평가)

  • Son, Jung-Hee;Park, Ji-Hwa;Kim, Chin-Soo;Byun, Ki-Jung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제27권2호
    • /
    • pp.164-170
    • /
    • 2005
  • The purpose of this study was to compare a sample of patients who had condylar fractures treated with open reduction using different plating techniques, to evaluate which plating technique is useful for stable fixation for fractures of the mandibular condyle and to evaluate effectiveness of resorbable miniplate. There were 60 patients (41 males, 19 females) whose condylar fractures were treated with open reduction. Rigid fixation was performed with a single miniplate, double miniplate ot one miniplate & one microplate and single resorbable plate. All patients remained intermaxillary fixation for 1 week postoperatively. Active physiotherapy was started after 2 weeks postoperatively. Radiographic evaluation (plate fracture, plate bending, screw loosening, displacement of condyle etc.) was performed at pre-operative, immediate, 2 weeks, 1 month, 3 months, 6 months after surgery. Clinical evaluation included degree of mouth opening, occlusion, mandibular lateral excursion, infection and facial nerve paralysis. In radiographic evaluation, displacement of fractured condylar segment associated with plate bending or screw loosening were showed 6 cases and 3 cases for single miniplate system and resorbable miniplate system. There was no patients who have this problem on double miniplate system. The results revealed that the application of two miniplates were more recommendable than single miniplates. When we select resorbable miniplate system, we should consider the type of fractures, post-operative treatment protocol and surgical technique.

Characterization of Cr-P-C/MoS2 composite plating electro-deposited from trivalent chromium

  • Park, Jong-Kyu;Seo, Sun-Kyo;Byoun, Young-Min;Lee, Chi-Hwan
    • Journal of Ceramic Processing Research
    • /
    • 제19권6호
    • /
    • pp.445-449
    • /
    • 2018
  • Chromium plating is a common surface treatment technique extensively applied in industry due its excellent properties which include substantial hardness, abrasion resistance, corrosion resistance, surface color, and luster. In this study, the effect of $MoS_2$ particles of the composite coating was investigated. To improve the lubrication of mold, $Cr-P-C/MoS_2$ composite plating was studied by varying the $MoS_2$ content. The current efficiency of the composite plating incorporated $MoS_2$ particles was increased at $MoS_2$ contents of 0.5 and 1.0 g/l due to the incorporation of fine particles. On the other hand, when the content of $MoS_2$ is 1.0 g/l or more, the current efficiency is lowered due to an increase in impact on the cathode surface. In order to evaluate the mechanical properties of Scratch test were conducted. Scratch test confirmed the lubricity and abrasion resistance characteristics revealed that the composite plating with added $MoS_2$ had relatively low surface roughness and uniform surface modification to improve its properties.

Real-time Monitoring of Cu Plating Process for Semiconductor Interconnect

  • Wang, Li;Jee, Young-Joo;Soh, Dae-Wha;Hong, Sang-Jeen
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.64-64
    • /
    • 2009
  • As the advanced packaging technology developing, Copper electro-plating processing has be wildly utilized in the semiconductor interconnect technique. Chemical solution monitoring methods, including PH and gravity measurement exist in industry, but economical and practical real-time monitoring has not been achieved yet. Red-green-blue (RGB) color sensor can successfully monitor the condition of $CuSO_4$ solution during electric copper plating process. Comparing the intensity variations of the RGB data and optical spectroscopy data, strong correlation between two in-situ sensors have shown.

  • PDF

pH Effects of Electroless Ni Plating on ABS Plastics

  • Song, T.H.;Lee, J.K.;Ryoo, K.K.;Lee, Y.B.
    • Corrosion Science and Technology
    • /
    • 제3권1호
    • /
    • pp.26-29
    • /
    • 2004
  • Metal plated plastics are becoming more prevalent in materials of communication parts. A new technique MmSH is a process of injecting plastics to produce innovated physical properties compared to the conventional injection process. This study involves two ways of coating plastics Ni by electroless plating and varying bath and plasma treatment for improved adhesion strength between plating layer and surface. MmSH injection processed ASS with plasma treated after neutralization showed a superior adhesion force and a gloss and rate of deposition when it was in pH 7.5. On the other hand, conventional injection processed ASS was in pH 6.5.

CHARACTERISTICS OF PLATED GOLD LAYER ON ANSI 304 STAINLESS STEEL ACCORDING TO THE VARIATION OF PRETREATMENTS AND ELECTROLYSIS CONDITIONS

  • Lee, Dong-hun;Lee, Jae-Bong
    • Journal of the Korean institute of surface engineering
    • /
    • 제32권3호
    • /
    • pp.224-234
    • /
    • 1999
  • An attempt was made to characterize the relationship between pretreatment processes, electrolysis conditions and behaviors of the plated gold layer. In order to investigate the effect of pretreatment processes on plating, rest potential measurements of various pretreated stainless steels and a.c.-impedance spectroscopy tests were carried out in the strike plating solution. Characteristics of plated gold layers and adhesions between plated gold layers and stainless steel substrates were examined by scratching tests and micro-Vickers hardness tests. The result shows that the strike plating enhanced the adhesion of interface, the cathodic electro-activation pretreatment process improving both corrosion resistance and adhesion strength. The preferred orientations of plated gold layers were examined by the X-ray diffraction technique. As the current density increases, [111] preferred orientation of plated gold layers was found to become well developed.

  • PDF

New Technical Tip for Anterior Cervical Plating : Make Hole First and Choose the Proper Plate Size Later

  • Park, Jeong-Yoon;Zhang, Ho-Yeol;Oh, Min-Chul
    • Journal of Korean Neurosurgical Society
    • /
    • 제49권4호
    • /
    • pp.212-216
    • /
    • 2011
  • Objective : It is well known that plate-to-disc distance (POD) is closely related to adjacent-level ossification following anterior cervical plate placement. The study was undertaken to compare the outcomes of two different anterior cervical plating methods for degenerative cervical condition. Specifically, the new method involves making holes for plate screws first with an air drill and then choosing a plate size. The other method was standard, that is, decide on the plate size first, locate the plate on the anterior vertebral body, and then drilling the screw holes. Our hypothesis was that the new technical tip may increase POD as compared with the standard anterior cervical plating procedure. Methods : We retrospectively reviewed 49 patients who had a solid fusion after anterior cervical arthrodesis with a plate for the treatment of cervical disc degeneration. Twenty-three patients underwent the new anterior cervical plating technique (Group A) and 26 patients underwent the standard technique (Group B). POD and ratios between POD to anterior body heights (ABH) were measured using postoperative lateral radiographs. In addition, operating times and clinical results were reviewed in all cases. Results : The mean durations of follow-up were $16.42{\pm}5.99$ (Group A) and $19.83{\pm}6.71$ (Group B) months, range 12 to 35 months. Of these parameters mentioned above, cephalad POD (5.43 versus 3.46 mm, p=0.005) and cephalad POD/ABH (0.36 versus 0.23, p=0.004) were significantly greater in the Group A, whereas operation time for two segment arthrodesis (141.9 versus 170.6 minutes, p=0.047) was significantly lower in the Group A. There were no significant difference between the two groups in caudal POD (5.92 versus 5.06 mm), caudal POO/ABH (0.37 versus 0.32) and clinical results. Conclusion : The new anterior cervical plating method represents an improvement over the standard method in terms of cephalad plate-to-disc distance and operating time.