• 제목/요약/키워드: Plate-fin tube

검색결과 56건 처리시간 0.023초

Performance Analysis of an Indoor Heat Exchanger with R-410A for GHP Application

  • Lee, Jong-Ho;Kim, Sung-Soo;Cha, Woo-Ho;Kang, Yong-Tae
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권4호
    • /
    • pp.129-134
    • /
    • 2009
  • The objectives of this paper are to study the effects of thermal and geometric conditions on the performance of indoor heat exchangers with R-410A for Gas Engine Driven Heat Pump (GHP) application and to find the optimum design conditions of indoor heat exchangers by parametric analysis for the key parameters. The key parameters are number of tube row, number of tube pipe, fin pitch and transverse tube pitch. In the air side, moisture out of the humid air condenses on the fin surface while the refrigerant (R-410A) boils inside the smooth tube. Therefore this study uses Log Mean Enthalpy Difference (LMHD) method to analyze the heat transfer from the humid air to the refrigerant. This study determines the heat exchanger size, air side/refrigerant side pressure drop and overall heat transfer coefficient. Optimum design conditions for the key parameters are also determined by the parametric analysis. The results show that number of rows and pipes, fin pitch have significant effect on the heat exchanger size. It is also found that the tube length of the louver fin is $17{\sim}30%$ shorter than that of the plate fin.

컴퓨터 시물레이션 에 의한 太陽熱 集熱器 의 最適設計 에 관한 硏究 (The Analysis of Optimum Design Parameters for a Flat-Plate solar Collector Through Computer Simulation)

  • 조수원;김종보
    • 대한기계학회논문집
    • /
    • 제8권1호
    • /
    • pp.1-9
    • /
    • 1984
  • In the utilization of solar energy most often a flat solar collector is used for solar heating, system. Since solar energy is absorbed through this solar collector, it is considered to be a most important part in the whole solar heating system. The purpose of the present investigation is to evaluate the influence of varying design parameters for thermal performances of flat-plate solar collector. By analysing these parameters, optimum design of solar collector would become possible. Specification of the existing solar collector are utilized in calculation as a starting point. Analysis is carried out numerically for "Unit Solar Collector" which is composed of fin and tube. Among design parameters. such parameters as mass flow rate per unit area, tube spacing and fin thickness are selected as variables in the computer simulation model. Results are presented for thermal performances of flat-plate solar collector for each important design parameters, so that predictions become possible through numerical analysis without performing experiments whenever it is required. required.

슬릿과 평판 핀-관 열교환기의 공기측 열전달 및 마찰특성 (Air-side Heat Transfer and Friction Characteristics of Finned Tube Beat Exchangers with Slit Fin or Plain Fin)

  • 권영철;장근선;박병권;권정태;정지환
    • 에너지공학
    • /
    • 제16권1호
    • /
    • pp.7-14
    • /
    • 2007
  • 본 연구는 핀-관 열교환기의 건표면과 습표면 조건에서의 공기측 열전달 및 마찰특성을 실험을 통해 이해하고자 수행하였다. 핀-관 열교환기의 성능평가 및 해석기술을 확보하기 위하여 공기엔탈피식 칼로리 미터를 이용하였다. 핀형상은 슬릿과 평판이며, 관경은 7.0mm로 2열과 3열 핀-관 열교환기 4종에 대해 실험하여, 건표면과 습표면의 공기측 열전달 및 마찰특성을 조사하였다. 습표면에서 습도변화(RH 50%, 70%)에 따른 습도영향도 조사하였다. 건표면 조건에서 Re 수가 증가할수록 j 계수는 감소하며, 2열이 3열보다 높았다. 마찰계수는 슬릿 핀이 평판 핀보다 높았다. 습표면 조건에서 슬릿 핀이 평판 핀보다 그리고 2열이 3열보다 우수한 열전달효과를 나타내었다. j 계수와 마찰계수는 습도변화, 열수, 핀 형상에 따라 달라짐을 확인하였다.

CFD 해석을 통한 냉장고용 응축기 전열성능 연구 (CFD ANALYSIS OF HEAT TRANSFER PERFORMANCE OF A REFRIGERATOR CONDENSER)

  • 유성수;황도연;이명수;한병윤;박형구
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2009년 춘계학술대회논문집
    • /
    • pp.303-309
    • /
    • 2009
  • In this study, the heat transfer and flow field of condenser used on Kim-chi refrigerator is analysed with numerical method. Main objective is to present the base data for designing new condenser model with improvement of heat transfer performance. For CFD analysis, a commercial code, STAR-CCM+ was used. The water was used for the inner working fluid and the air was used for the outer fluid. The condenser type used in this study is a flat plate fin-and-tube heat exchanger. As factors for performance analysis, the effect of condenser geometry and air velocity was investigated. As a result, it has been observed that there is a suitable fin pitch with which heat transfer performance of condenser is maximized.

  • PDF

표면처리를 이용한 단일진공관과 기존 이중진공관 태양열집열기의 성능비교 연구 (Study on Performance Comparison for Solar Collectors with Single Evacuated Tube using Surface Treatment and Commercial Double Evacuated Tube)

  • 전태규;양영준;이경희;안영철
    • 한국기계가공학회지
    • /
    • 제12권5호
    • /
    • pp.149-156
    • /
    • 2013
  • The performances of solar collectors with single and double evacuated tube were experimentally compared. The solar collector with single evacuated tube using surface treatment in this study consists of radiation fin, heat pipe, absorber plate, glass tube, cap and regulating valve, and so on. Surface treatment was conducted for heat pipe and absorber plate with black chrome plating and copper black coating. As the results, the performance of solar collector with single evacuated tube using surface treatment showed good results compared that of double evacuated tube. Absorber plate played a positive role in performance and showed increase of about 28%. Further performance depends on vacuum degree and vacuum degree has to be considered economical efficiency in solar collector.

냉장고용 롤-플레이트형 휜-관 열교환기의 성능에 관한 연구 (A Study of Performance of Roll-plate type fin-tube Heat Exchanger for the Refrigerator)

  • 안성준;김종수;권오붕;박영종;하영주;최상조
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2292-2297
    • /
    • 2008
  • Recently, a study on condensers for refrigerators has focused on new model which will cost less and will be more efficient. Some widely used condensers for domestic refrigerators are wire-and-tube type condenser, hot-wall type condenser, and spiral type condenser. Some companies which use the spiral type condenser at the moment try to develop a new type condenser which will cost less and will be as efficient as the spiral type. The new type condenser consists of a steel tube, steel plates and louver fins attached to the tube. The tube and the plate are bent into a single-passage serpentine shape.

  • PDF

Characteristic Analysis of Condensate Carry-Over According to the Surface Tensions in the Wet and the Dry Conditions on the Fin Surfaces of Heat Exchangers

  • Kim, Byeung-Gi;Lee, Su-Won;Ha, Sam-Chul;Ahn, Young-Chull;Lee, Jae-Keun
    • Journal of Mechanical Science and Technology
    • /
    • 제20권11호
    • /
    • pp.1942-1949
    • /
    • 2006
  • Typically, condensate forms as droplets on the fin surfaces and may bridge the space between the fin surfaces. This is due to the dry characteristics inherent to the fin surface. The droplets increase the air-side pressure drop. In the case of high air velocities, these droplets may be blown off the fins and entrained in the air stream. To minimize the formation of condensate droplet, the wet ability of the fins must be improved. The carry-over velocity is affected by fin surface characteristics. To avoid carry-over in the air conditioner having the highest air velocity of 1.5 m/sec, the dynamic contact angle (DCA) should be at least lowly under $60^{\circ}$.

판형 핀을 가진 원통-다관형 열교환기의 열전달 특성에 관한 연구 (Study on Heat Transfer Characteristic of Shell-and-Tube Heat Exchanger with Plate Fin)

  • 임태우;조동현
    • 한국산학기술학회논문지
    • /
    • 제10권1호
    • /
    • pp.46-51
    • /
    • 2009
  • 본 논문은 세 개의 서로 다른 관수(9, 13 그리고 19)를 가지는 원통-판형 핀 관의 원통 측에서의 열전달 성능을 실험적 방법으로 평가하였다 관외를 흐르는 오일은 관내를 흐르는 냉각수에 의해 냉각된다. 오일 쿨러의 원통-다관형 열교환기는 단일 셀 통로와 두 개의 관 통로로 구성되며, 관 내경은 8.82mm, 관 길이는 575mm이다. 오일의 질량 유량은 $1.2{\sim}6.0m^3/h$이며, 냉각수의 질량 유량은 $0.6{\sim}3.0m^3/h$이다. 실험결과 9개의 관수를 가지는 열교환기의 총합 열전달계수는 13개와 19개의 관수의 열전달계수보다 각각 약 1.8배와 2.3배 높게 나타났다.

냉장고 응축기의 전열성능에 대한 CFD 해석 (CFD ANALYSIS ON HEAT TRANSFER PERFORMANCE OF A REFRIGERATOR CONDENSER)

  • 유성수;황도연;이명수;한병윤;박형구
    • 한국전산유체공학회지
    • /
    • 제14권3호
    • /
    • pp.56-62
    • /
    • 2009
  • In this study, the heat transfer and flow field of a condenser used for a Kim-chi refrigerator is analysed with numerical method. Main objective is to present the basic data for designing a new condenser model with improvement of heat transfer performance. For CFD analysis, a commercial code, STAR CCM+ was used. The water was used for the inner working fluid and the air was used for the outer fluid. The condenser type used in this study is a flat plate fin-and-tube heat exchanger. As analysis parameters, the effect of condenser geometry and air velocity was investigated. For validation of the numerical calculations, the results were compared with the experimental ones. The heat transfer rates for both results were consistent with each other by maximum 5 % error. Based on this comparison, the numerical analysis was done with some modifications. As a result, it has been observed that there is a suitable fin pitch with which heat transfer performance of condenser is maximized.

히트파이프 히트싱크에서 평판 휜-관으로 구성된 공기유동 냉각채널의 대류 열전달 특성에 관한 수치해석 (A Numerical Analysis of Convective Heat Transfer in Air Flow Channels of a Plate Fin-tube Matrix for Heat Pipe Heat Sinks)

  • 김성훈;신현명;김철주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권8호
    • /
    • pp.862-869
    • /
    • 2005
  • A study on convective cooling characteristics has been done in the channels with heat pipes and associated Plane fins Analysis with FLUENT V5.0 lies its Purpose on the possible enhancement of heat transfer capability between an existing three in-line arrayed heatpipes and an extending four in-line arrayed heatpipes with increasing channel width. Numerical analysis is limited to the laminar flow in an isolated flow channel by employing cyclic boundary conditions for calculation purposes. Friction factors for three and four in-line arrayed heatpipes are compared with experimental results. In addition, temperature behavior at the plate fin for the three in-line arrayed heatpipes is compared with experiment. Friction factors and overall channel heat transfer coefficients (and/or Nusselt numbers) are presented as a function of Reynolds number. An increase of number of heatpipes and channel width reults in a decrease of the friction factor and doesn't not result in an increase of heat transfer performance. However. considering the 25$\%$ increase of heat load accompanies with maximum 8$^{\circ}C$ rise of average temperature of heat pipes, the four in-line array with the increase of channel width of heat pipe heat sink can be considered appropriate.