• 제목/요약/키워드: Plate type STR reactor

Search Result 2, Processing Time 0.018 seconds

The Performance Evaluation of Plate Type STR Reactor with Variation of S/C Ratio and Fuel Supply (연료 공급 및 S/C비에 따른 평판형 STR 반응기 성능 평가)

  • Kim, Hun-Ju;Heo, Su-Bin;Park, Jae-Min;Yoon, Bong-Seok;Lee, Do-Hyung
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.2
    • /
    • pp.191-198
    • /
    • 2011
  • According to the propagation of fuel cell system, the importance of that system efficiency is being magnified. Thus, the efficiency improvement of reformer which is the important factor of fuel cell system will be required. This study has been experimentally performed to evaluated the performance of plate type STR reactor. At first, we changed fuel flow rate (2, 3 and 4 l/min) in burner, and then we measured a proportion of hydrogen in produced gas through the STR reactor by G.C for evaluating the performance of plate type STR reactor in various fuel supply conditions. And we changed S/C ratio (2 and 4) and measured a proportion of hydrogen in produced gas through the STR reactor. As a results, condition at fuel flow rate 2 and 3 l/min could not be supplied amount of heat for STR sufficiently. Condition at fuel flow rate 4 l/min could supplied a heat excessively. And condition at S/C ratio 2, reaction occurred insufficiency. But condition at S/C ratio 4 was excess. From above, we found the optimum conditions that were fuel rate 3.5 l/min and S/C ratio 3.

The performance evaluation for H2 reforming of the plate type hydrogen generation system (평판형 수소생산시스템의 수소개질 성능평가)

  • Heo, Su-Bin;Yun, Bong-Seock;Lee, Do-Hyung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.6
    • /
    • pp.602-608
    • /
    • 2014
  • Hydrogen energy, a field of low-carbon substitute energy, can be produced by fossile fuel reforming and electrolysis of water etc. We developed 1kW class flat type reformer for PEM Fuel Cells. The PEMFC is highly sensitive to carbon monoxide because CO has detrimental effects on the performance of the fuel cell. Thus, reformed gas supplied to Fuel cell system, which maintained CO concentration below 10ppm. After applying optimum drive condition, reformed gas was measured with gas chromatography and could find out about each experimental condition of $H_2$ and CO concentration. As a results, The 1kW class plate type hydrogen generation system's optimum condition is A/F ratio ${\alpha}=1.3$, STR temperature 1023K, S/C ratio 3, and $PrOx1{\cdot}2$ 30cc/min. It turns out that installation of PrOx 2 stage is more efficient for reducing CO concentration.