• 제목/요약/키워드: Plate in Water

검색결과 1,501건 처리시간 0.03초

공냉식 수직평판형 흡수기의 흡수과정에 대한 근사해법 (Approximate Solution of Absorption Process in an Air-Cooled Vertical Plate Absorber)

  • 정은수
    • 설비공학논문집
    • /
    • 제6권4호
    • /
    • pp.453-462
    • /
    • 1994
  • An unsteady quasi one-dimensional model of momentum, heat and mass transfer in a falling film of a vertical plate absorber which is cooled by air was developed using the integral method. Energy conservation of the absorber wall is considered in the model. The model can predict absorption rate, film thickness and mean velocity as well as concentration and temperature profiles. Predictions of steady state temperature and concentration profiles for LiBr/water system for constant wall temperature condition are in good agreement with the two-dimensional finite difference method solutions. Effects of operating conditions, such as convective heat transfer coefficient between the cooling air and the absorber wall, cooling air temperature and film thickness at inlet, on absorption rate of water vapor into LiBr/water solution were shown.

  • PDF

Gasket 방식 판형 열교환기의 고.저온부 유량 및 압력차에 따른 압력강하 특성 (Pressure Drop of a Gasket Sealed Plate Type Heat Exchanger upon its Operating Conditions)

  • 안준;김혁주;최규성;송대석
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.189-194
    • /
    • 2009
  • In a gas engine based cogeneration system, heat is recovered from two parts, which are jacket water and exhaust gas. The heat from the jacket water is often recovered by a plate type heat exchanger and used for the room heating and/or hot water supply. Depending on the operating conditions of engine and heat recovery system, there should be imbalance in the flow rate and supply pressure between engine and heat recovery side of the heat exchanger. The imbalance cause the deformation of the plate, which affects the pressure drop characteristics. In the present study, the pressure drop inside the heat exchanger has been investigated in a 1/5 scaled test rig and compare with the experimental correlations, which are used for the design.

  • PDF

서울지역 급식 국민학교의 음용수 수질에 관한 연구 (A Study on the Drinking Water Quality for Primary Lunch School in Seoul)

  • 이원묘;이용옥;방형애
    • 한국환경보건학회지
    • /
    • 제21권1호
    • /
    • pp.7-20
    • /
    • 1995
  • The aims of this study are to enhance the students' knowledge of the drinking water and its reliability by investigating drinking water situation on the drinking water. The results are as following 1. Status and drinking behavior about school drinking water (1) 97.82% of the schools are using the tap water as the resource of drinking water. (2) 46 schools are in possession of water tank and 18 schools of them are using the water tank as the resource of drinking water. The clearing and sanitization of the tank are carried out once in a year with hypochloronatrium by the low-level officials. (3) 51.28% of the schools are providing the students with drinking water and 75% of them with boiled water. The drinking water supply managers are low-level officials, nurse teachers, and dietitian. 2. Analysis of the drinking water quality (1) Most of the drinking water provided by the school are tap water 35.8%, barely tea 5.85%, filtered water 6.3%, ground water 1.1% and all turned out to be suitable for drinking. (2) The drinking water carried from home turned out to be unsuitable for drinking except pH criterion, especially the test of APC(Aerobic Plate Count) and Coliform group showed worse degree. These results were caused by the hygiene problem and maltreatment in water container.

  • PDF

CFD 모사 기법을 이용한 전해반응기 내부 흐름 특성 분석 (Flow Characteristics Analyses within the Electrolysis Reactor using the CFD Simulation Technique)

  • 정종식;이승재;이재복
    • 상하수도학회지
    • /
    • 제30권6호
    • /
    • pp.745-753
    • /
    • 2016
  • The objective of this study was to investigate design factors of the electrolysis reactor through the CFD(computational fluid dynamics) simulation technique. Analyses of velocity vector, streamline, chloride ion concentration distribution showed differences in flow characteristics between the plate type electrode and the porous plate type electrode. In case of the porous plate type electrode, chlorine gas bubbles generated from the anode made upward density flow with relatively constant velocity vectors. Electrolysis effect was more expected with the porous plate type electrode from the distribution of chloride ion concentration. The upper part of the electrolysis reactor with the porous plate type electrode had comparatively low chloride concentration because chloride was converted to the chlorine gas formation. Decreasing the size and increasing total area of rectifying holes in the upper part of cathodes, and widening the area of the rectifying holes in the lower part of cathodes could improve the circulation flow and the efficiency of electrolysis reactor.

체적압력판추출기의 측정법 개선에 관한 연구 (Study on the Improvement for Measuring Procedures of Volumetric Pressure Plate Extractor)

  • 유건선
    • 대한토목학회논문집
    • /
    • 제30권4C호
    • /
    • pp.185-191
    • /
    • 2010
  • 축전이기법을 사용하는 체적압력판추출기(이하 체적압력판)로 실내시험실에서 함수특성곡선을 구할 수 있다. 체적압력판을 사용하면, 매 단계마다 공기압을 차단하지 않고 시험하는 동안 흙시료로부터 추출되는 간극수의 부피를 연속적으로 측정할 수 있는 장점이 있다. 반면에, 시료내 간극수압을 일정하게 유지하기 위하여, 에어 트랩, 발라스트 튜브, 저장뷰렛, 진공펌프 등을 사용하는 체적압력판의 추출수 부피측정은 매우 복잡하고 지루한 작업을 수반한다. 이러한 문제점을 개선하고자 수정체적압력판을 개발하여 풍화잔류토에 대한 시험을 수행하였다. 수정 시험기는 매트릭석션의 범위에 따라 ASTM D 6836-02의 Method A와 Method B 두 방법 모두 사용하여 추출수의 부피를 측정할 수 있다. 본 논문에서는 수정 시험기의 측정원리, 개선점, 시험결과 및 토의를 서술하였다.

A Study on the Microbiological Quality of Drinking Water and Changes During Storage

  • Kim, Jong-Gyu
    • 한국환경보건학회지
    • /
    • 제33권6호
    • /
    • pp.517-521
    • /
    • 2007
  • To assess possible risks from the consumption of drinking water from various sources, a survey of the microbiological quality of tap water, commercial bottled drinking water which is exploited from natural mineral water, and natural spring water was conducted. A total of 4 different brands of commercial bottled drinking water, and 4 types of spring water from different sources, and tap water from 4 private houses were tested for four index microorganisms, and the microbial quality changes of the water during the storage at room temperature or refrigerated temperature for 7 days. Aerobic plate counts of all of the initial water samples were still within 100 CFU/ml (drinking water standard of Korea). Total coliforms, fecal coliforms, and E. coli were not detected in all of the water samples at initial. However, aerobic plate counts of three types of spring water and three types of bottled drinking water stored at room temperature showed higher levels than the standards in 5 days. Total coliforms were detected in three types of spring water after one day's storage at room temperature, and in one type of bottled drinking water after 5 days' storage. These results indicate that some of the spring water surveyed are not safe to drink, and the spring water and bottled drinking water after opening the lid should not be stored at room temperature, if they are used for drinking.

중력방향과 대향류인 저속 원형노즐제트 충돌에 의한 일정 두께 하향 등온원형평판에서의 열전달 현상 (The Study of Heat Transfer on a Isothermal Circular Surface by an Impinging, Circular Water Jets with the Low Velocity Against the Direction of Gravity)

  • 엄용균
    • 한국수소및신에너지학회논문집
    • /
    • 제25권4호
    • /
    • pp.449-458
    • /
    • 2014
  • The heat transfer phenomenon was investigated in this study when a single round water jet with the low velocity and against the direction of gravity flows to the downward facing Isothermal of definite thickness circular plate. Experimental investigation is performed for a single round jet diameter 4mm, 6mm, and 8mm with the jet velocity 2.4m/s and jet fluid temperature of $24^{\circ}C$, varied the ratio of nozzle clearance/nozzle diameter (H/D)1, 2, 3, 6, and 8, on circular plate isothermal condition with $85^{\circ}C$. The local convection heat transfer coefficient distributions are analyzed based on the visualization of jet flow field. The effects of the diameter of Nozzle, the ratio of H/D and the ratio of nozzle diameter/circular plate diameter on heat transfer phenomenon are investigated. As a results of experiment is obtained correlation equation, $Nu_r=3.18Re_r^{0.55}Pr_r^{0.4}$.

음향임피던스 정합을 이용한 액면레벨 Limit센서의 구현 (Fabrication of Water Level Limit Sensor Utilizing Acoustic Impedance Matching)

  • 김철한;이수호;사공건;이준희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.1870-1872
    • /
    • 2005
  • In this study, an ultrasonic level limit sensor with a new structure utilizing the acoustic impedance matching is proposed to be able to check it out a change of water-level. 2 PZT resonators with the same property are bonded directly on the polyethylene plate. One resonator is for transmitter as an ultrasonic transducer, the other one is for receiver. In this case, a polyethylene plate will operate as an acoustic guider to transmit a transverse wave between 2 PZT resonators in air. While in the water, a polyethylene plate having a similar acoustic impedance with the water will be emitted an acoustic energy into the water as a longitudinal wave. According to this mechanism, there was a wide difference of acoustic signal output between underwater and in air. As a summary, this proposed level limit sensor could be used as a strong candidate with low cost and more stable one.

  • PDF

음향임피던스 정합을 이용한 액면레벨 리미트 센서의 기초연구 (A Basic Study on the Water Level Limit Sensor Utilizing Acoustic Impedance Matching)

  • 김철한;이수호;사공건;이준희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.352-353
    • /
    • 2005
  • In this paper, an ultrasonic level limit sensor with a new structure utilizing the acoustic impedance matching is proposed to be able to check it out a change of water-level. 2 PZT resonators with the same property are bonded directly on the polyethylene plate. One is for transmitter as an ultrasonic transducer, the other one is for receiver. In this case, a polyethylene plate will operate as an acoustic guider to transmit a transverse wave between 2 PZT resonators in air. While in the water, a polyethylene plate having a similar acoustic impedance with the water will be emitted an acoustic energy into the water as a longitudinal wave. According to this mechanism, there was a wide difference of acoustic signal output between underwater and in air. As a summary, it is believed that this proposed level limit sensor could be used as a new one with strong toughness from the external electrical and mechanical noise.

  • PDF

판형 열교환기 전열판의 부식 파손 분석 (Corrosion Failure Analysis of Flow Plate in Plate Heat Exchanger)

  • 송민지;최가현;채호병;김우철;김희산;김정구;이수열
    • Corrosion Science and Technology
    • /
    • 제20권4호
    • /
    • pp.204-209
    • /
    • 2021
  • Corrosion failure analysis of the flow plate, which is one of the accessories of the plate heat exchanger in a district heating system, was performed. The flow plate is made of 316 stainless steel, and water at different temperatures in the flow plate exchanges heat in a non-contact manner. The flow plate samples in which water mixing issues occurred were collected. Corrosion-induced pits, oxides, and contaminants were observed at locations where two plates are regularly in contact. The EDS analysis of the surface oxides and contaminants revealed that they were composed of carbon, silicon, and magnesium, which came from chemical adhesives. The IC/ICP analyses showed that the concentration of chloride ions was 30 ~ 40 ppm, which was not sufficient to cause corrosion of stainless steel. In the crevice, a local decrease in dissolved oxygen occurs along with an increase in chloride ions, thus forming an acidic environment. These environments destroyed the passive film of stainless steel, resulting in pits. Moreover, contaminants formed a narrower gap between the two metal plates and inhibited the diffusion of ions, thereby accelerating crevice corrosion.