• Title/Summary/Keyword: Plate holder

Search Result 31, Processing Time 0.056 seconds

Development of High Precision Plate Holder in Automotive Seat Recliner by Mechanical Press(I) : Application of FCF Method (기계식 프레스에 의한 자동차 시트 리클라이너의 고정밀 플레이트 홀더 개발(I) : FCF 공법 적용)

  • Kim, Byung-Min;Choi, Hong-Seok;Chang, Myung-Jin;Bae, Jae-Ho;Lee, Seon-Bong;Ko, Dae-Cheol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.7
    • /
    • pp.55-63
    • /
    • 2008
  • Fine blanking is a process of press shearing which makes it possible to produce the thick sheet metal of the finished surface and the close dimensional accuracy over the whole material thickness in the single blanking operation. In this paper, a plate holder of automotive seat recliner is manufactured by FCF(Flow Control Forming) method using the conventional mechanical press instead of the fine blanking press. Main processes for manufacturing of the plate holder by FCF method are embossing, half blanking and trimming processes. Optimal clearance, stripper force and counter force to increase the dimensional accuracy of the plate holder have been investigated by FE-analysis. As a result of FE-analysis, the clearance for both embossing and half blanking processes was -2%t and the forces of stripper and counter were 25ton and 15ton, respectively. After manufacturing the plate holder by FCF method, the measured dimensional characteristics have been compared with the required specifications as the final product. Although the dimensional accuracy of the plate holder manufactured by FCF method was a little inferior to that by fine blanking process, it was satisfactory in a general sense.

Development of High Precision Plate Holder in Automotive Seat Recliner by Mechanical Press(II) : Control of Burr Formation (기계식 프레스에 의한 자동차 시트 리클라이너의 고정밀 플레이트 홀더 개발(II) : 버 형성 제어)

  • Kim, Byung-Min;Choi, Hong-Seok;Chang, Myung-Jin;Bae, Jae-Ho;Kim, Dong-Hwan;Ko, Dae-Cheol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.7
    • /
    • pp.64-71
    • /
    • 2008
  • Burr generated on plate holder should be removed through additional process, because it has an influence on the function of automotive seat recliner. The process layout to perform simultaneously embossing and half blanking of plate holder has been developed in this study in order to minimize the influence of burr formation. The optimal process condition to satisfy the required dimensional accuracy of plate holder has been determined using Taguchi method and finite element analysis. It has been shown from experimental results that the proposed method is decidedly superior to the previous FCF method from the aspect of sheared surface, roll-over, flatness and burr height.

The evaluation of usefulness of the newly manufactured immobilization device (치료보조기구의 제작 및 유용성 평가)

  • Seo Seok Jin;Kim Chan Yoeng;Lee Je Hee;Park Heung Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.1
    • /
    • pp.45-55
    • /
    • 2005
  • Purpose : To evaluate the usefulness of the handmade patient immobilization device and to report the clinical results of it. Materials and methods : We made two fusion images and analyzed those images. One image is made with diagnostic MR image and CT image, the other with therapeutic planning MR image and CT image. With open head holder, we measured the skin dose and attenuation dose. Also, we made the planning CT couch plate with acrylic plate and styrofoam and compared artifact. Results : We could get more accurate fusion image when we use MR head holder(within 2mm error). The skin dose was reduced 2 times and the attenuation dose was reduced more than $20\%$ when open head holder used. The planning CT couch plate was more convenient than conventional board and reduced artifact remarkably. Conclusion : We could verify the localization point in the MR image which is taken with MR head holder. So we could fuse the image more accurately. The same method could be applied to PET and US image, if the alike immobilization device used. With open head holder, the skin dose and the attenuation dose was reduced. And those above devices could substitute for expensive foreign device, if those are manufactured adequately.

  • PDF

A Study on the Load Characteristics of a Swash Plate Piston Pump Holder (Cradle) with Grooves Considering the Squeeze Effect (스퀴즈 효과를 고려한 사판식 피스톤 펌프 홀더의 그루브 유무에 따른 부하특성에 대한 연구)

  • Ju, Gyeong Jin;Seol, Sang Suk;Kim, Yong Gil;Kim, Soo Tae
    • Journal of Drive and Control
    • /
    • v.17 no.1
    • /
    • pp.21-26
    • /
    • 2020
  • The load characteristics of a piston pump holder due to the squeeze effect are influenced by the surface shape and gap thickness of the holder (cradle). Therefore, the pressure distribution and the load capacity of the piston pump holder due to the squeeze effect are studied by using the CFD software and the surface shape and gap thickness of the piston pump holder are considered. In order to verify the accuracy of numerical results, the load capacities of a circular plate holder are numerically studied, and the accuracy of numerical results is verified by comparing with the theoretical results. Also, the pressure distribution and load capacity of the rectangular plate holder of a piston pump are obtained by using the CFD software. The results show that the load capacity of the square plate holder with grooves is slightly higher at a low gap thickness, but the effects of the number and arrangement of grooves on the load capacity of the holder are weak. We conclude that the load capacity and the maximum pressure are slightly affected due to the existence of grooves on the holder surface, and the fluid storing effect of the holder surface grooves during the operation is likely to prevent the dry-sticking phenomenon.

Numerical Fracture Mechanics Evaluation on Surface Cracks in a Spherical Oxygen Holder (구형 산소용기 내 표면균열에 대한 수치파괴역학 평가)

  • Cho, Doo-Ho;Kim, Jong-Min;Chang, Yoon-Suk;Choi, Jae-Boong;Kim, Young-Jin;Han, Sang-In
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.11
    • /
    • pp.1187-1194
    • /
    • 2009
  • During the last decade, possibility of flaw occurrences has been rapidly increased world-widely as the increase of operating times of petro-chemical facilities. For instance, from a recent in-service inspection, three different sized surface cracks were detected in welding parts of a spherical oxygen holder in Korea. While API579 code provides corresponding engineering assessment procedures to determine crack driving forces, in the present work, numerical analyses are carried out for the cracked oxygen holder to investigate effects of complex geometry, analysis model and residual stress. With regard to the detailed finite element analysis, stress intensity factors are determined from both the full three-dimensional model and equivalent plate model. Also, as an alternative, stress intensity factors are calculated for equivalent plate model by employing the noted influence stress function technique. Finally, parametric structural integrity evaluation of the cracked oxygen holder is conducted in use of failure assessment diagram method, J/T method and DPFAD method. Effects of the geometry and so forth are examined and key findings from the simulations are fully discussed, which enables to determine practical safety margins of spherical components containing a defect.

Numerical Simulation on the Steel Plate Cutting Performances of Bent-Shaped Charge Holder Blasting (드로잉 가공 성형폭약용기의 강판절단성능에 관한 수치해석적 연구)

  • Min, Gyeong-Jo;Park, Hoon;Oh, Se-Wook;Park, Se-Woong;Suk, Chul-Gi;Cho, Sang-Ho
    • Explosives and Blasting
    • /
    • v.36 no.3
    • /
    • pp.19-28
    • /
    • 2018
  • Locally damaged structures caused by earthquake or extraordinary external forces have been required to rapidly be dismantled because of its possibility of additional collapses. Particularly, steel frame structures were demolished by the shaped charge blasting method. Recently a research suggested a shape charge blasting technique which uses bent-shaped charge holder of copper plate and emulsion explosive charge to cut thick steel plates. This study simulated the cutting performance of the bent-shaped charge holder with considering types of explosives, thickness of copper liner and stand-off distances using LS-DYNA software. The shape charge blasting test of a 25mm thickness steel plate were used to calibrate the input parameters of the numerical models. The penetration depth and penetration width were analysed with different types of explosives, thickness of copper liner and stand-off distances.

New Fiduciary Plate and Orientation Marker for High Energy Radiation Therapy (고에너지 방사선치료의 정도관리를 위한 Fiduciary Plate 및 Orientation Marker의 개발)

  • Wu Hong-Gyun;Huh Sun Nyung;Kim Hak Jae
    • Radiation Oncology Journal
    • /
    • v.22 no.1
    • /
    • pp.69-75
    • /
    • 2004
  • Purpose : A new fiduciary plate and orientation marker have been devised to assist the quality assurance (QA) procedures for port films in radiation therapy department. The plate is used in conjunction with the film/cassette combination during weekly QA procedures, at Seoul National University Hospital (SNUH), in order to verify treatment fields in high radiation therapy. Materials and Methods : A new fiduciary plate was fabricated using an acrylic plate, cerrobend, standard blocking tray and mercury. The acrylic plate had the dimension of $1{\times}25{\times}25$ cm, with two fiduciary markers. The plate was rigidly attached onto the standard blocking tray, thus making it easier to set the fiduciary plate to the center on the radiation field on the linear accelerator. The plate had two 2-mm vertical and horizontal lines, with the minor scales in 2-cm steps. The orientation marker was a small mercury filled disk, which was inserted into the plate. Results : The geometrical structure of the lines in the plate makes it easier to correlate two different images between the simulation and port films. The marker clearly indicated the orientation of the film, for example, the anterior, posterior, left, right and various oblique orientations, without the placement of a conventional orientation marker. Also, the new orientation marker could easily be applied to the simulator by placing the small orientation marker onto the image intensifier or in front of the film/cassette holder. Conclusions : The new fiduciary plate appears to be useful in verifying the treatment fields, and the new orientation marker makes the film orientation simple, which is expected to lower the block fabrication errors.

Ferroelastic Domain and Refractive Property of $Gd_{2}(MoO_{4})_{3}$ Single Crystal ($Gd_{2}(MoO_{4})_{3}$ 단결정의 강탄성구역과 굴절률특성)

  • Son, Jong-Yoon;Lee, Chan-Ku;Lee, Su-Dae;Kim, Jae-Hyung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.98-102
    • /
    • 2002
  • We investigated domains and conoscope under the polarizing microscope and the index of refraction on the c-plate GMO which has the ferroelectric and ferroelastic phase at room temperature. To observed the change of refractive index in connection with domain, we developed an apparatus to obtain the refractive index by measuring the Brewster's angle. The resolution of the minimum rotation angle of this apparatus is $0.001^{\circ}$. To obtain the refractive index map on the sample, the moving distance of XY stage loaded sample holder is 60 mm and the minimum moving distance is 0.002 mm. Also, To obtain the indicatrix for single crystal, vertical turntable with sample holder and XY stage was loading on horizontal turntable. The minimum resolution angle of this vertical turntable is $0.001^{\circ}$. We measured the refractive index of transparent materials such as ferroelectrics. In the case of $Gd_{2}(MoO_{4})_{3}$, the Brewster angle is $62.11^{\circ}$ and then, the refractive index is 1.8895 by using He-Ne Laser. Also the refractive distribution of c-plate GMO was obtained with $400{\mu}m{\times}120{\mu}m$.

  • PDF

The effects of die design parameters on shearing of the thin plate (정밀금형의 설계인자의 박판 전단가공특성에 미치는 영향)

  • 신용승;김병희;김헌영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.523-526
    • /
    • 1997
  • Sheanng is one of the most important operating processes in the field of sheet metal manufacturing. Compared with casting, forging and machining, shearing is very economical to obtain the desired shape. In recent years there has been increasing the use of shearing process in the manufacturing of small and light electronic components. In this paper, it has been researched the experimental investigation to examine the mfl uence of shearing process parameters such as clearance and lower holder configuration. Through the experiment results, the more narrow clearance gives the smaller burr height and the removal of lower holder makes the worse sheared surface. And FE simulation of shearing process using DEFORM-2D were camed out and the results compared w~th experimental studies

  • PDF