• Title/Summary/Keyword: Plate girder bridge

Search Result 258, Processing Time 0.025 seconds

Longitudinal anti-cracking analysis for post-tensioned voided slab bridges

  • Zhou, Zhen;Meng, Shao-Ping;Liu, Zhao
    • Structural Engineering and Mechanics
    • /
    • v.43 no.4
    • /
    • pp.459-473
    • /
    • 2012
  • Post-tensioned concrete voided slab girders are widely used in highway bridge constructions. To obtain greater section hollow rate and reduce the self-weight, the plate thickness of slab girders are designed to be small with the adoption of flat anchorage system. Since large prestress is applied to the anchor end section, it was found that longitudinal shear cracks are easy to occur along the voided slab girder. The reason is the existence of great shearing effect at the junction area between web and bottom (top) plate in the anchor end section. This paper focuses on the longitudinal anti-cracking problem at the anchor end of post-tensioned concrete voided slab girders. Two possible models for longitudinal anticracking analysis are proposed. Differential element analysis method is adopted to derive the solving formula of the critical cracking state, and then the practical analysis method for longitudinal anti-cracking is established. The influence of some factors on the longitudinal anti-cracking ability is studied. Results show that the section dimensions (thickness of bottom, web and top plate) and prestress eccentricity on web plate are the main factors that influence the anti-cracking ability. Moreover, the proposed method is applied into three engineering examples to make longitudinal anti-cracking verification for the girders. According to the verification results, the design improvements for these girders are determined.

An Experiment on Redundancy in Simple Span Two-Girder Bridge - Effects of Lateral Bracing (단경간 2-거더교의 여유도 평가 실험-수평브레이싱의 효과)

  • Park, Yong Myung;Joe, Woon Do Ji;Hwang, Min Oh;Lee, Dae Yong;Yoon, Tae Yang
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.3
    • /
    • pp.271-280
    • /
    • 2007
  • This paper presents the results of an experimental study to evaluate the redundancy in two plate-girder bridges, which are generally classified as non-redundant load path structures. The study was performed at a time when one of the two girders was damaged. The bottom lateral bracing was considered the experimental variable, and two 1/5-scale bridge specimens of simple span with and without a lateral bracing system were fabricated. Loading tests were first performed on the intact specimens without a cracked girder, within an elastic range. Thereafter, the ultimate loading tests were conducted on the damaged specimens with an induced crack at the center of a girder. The test results showed that the cross beams and the concrete deck redistributed some of the load to the uncracked girder, but the lateral bracing system played an important role in improving the redundancy during the damage and was also effective for load redistribution even when the bridge was intact.

An Experimental Study on the dynamic behavior of 4-Span Cable-Stayed Bridge with ${\pi}$-Type Girder (${\pi}$형 거더를 가진 4경간 사장교의 동적거동에 관한 실험적 연구)

  • Cho, Jae-Young;Kim, Young-Min;Lee, Hak-Eun;Yoon, Ki-Yong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.4 no.1 s.12
    • /
    • pp.15-24
    • /
    • 2004
  • Generally, a ${\pi}$-type girder composed of two I-type girders is known to have a significant disadvantage in wind resistance design because of aerodynamic instability. A representative bridge for this girder was Tacoma Narrows Bridge. Since Tacoma Narrows Bridge had very low stiffness of the bridge structure and its cross-section shape had aerodynamic instability, the bridge collapsed after severe torsion and vibration events in 19m/s wind speed. Aerodynamic vibration can be avoided by enhancing structural stiffness and damping factor and conducting a study of cross-section shapes. This study shows the angle of attack for the four-span cable stayed bridge having ${\pi}$-type cross-section and describes the aerodynamic characteristics of the changed cross-section with aerodynamic vibration damping additions, by carrying out two-dimension vibration tests. As a result of uniform flow and turbulent flow, the study shows that because the basic ${\pi}$-type cross-section alone can have efficient wind resistant stability, there is no need to have additional aerodynamic damping equipment. Since this four 230m-main-span bridge has a large frequency and also has a big stiffness compared to other bridges containing a similar cross-section, it has aerodynamic stability under the design wind speed.

Variation of Natural Frequency and Dynamic Behavior of Railway Open-Steel-Plate-Girder Bridge with Installing Disk Bearings (디스크 받침에 의한 철도 판형교의 고유진동수 및 동적 거동 변화)

  • Choi, Eun Soo;Lee, Hee Up;Kim, Sung Il;Kim, Lee Hyeon
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.4
    • /
    • pp.437-446
    • /
    • 2006
  • Open-steel-plate-girder(OSPG) bridges are one of the most prevalent bridge types among Korean railway bridges. They account for about 40% of all Korean railway bridges. However, the line-type bearings used for OSPG bridges generate several problems with respect to the bridges' dynamic behavior and maintenance. The replacement of the existing bearings with polyurethane disk bearings could be a possible solution to this problem. This type of disk bearing is an elastic bearing using a polyurethane disk. This study estimated the variations in the natural frequency of a bridge when disk bearings were installed and the bridge's dynamic behavior with a running locomotive and running trains. The first natural frequency of the bridge was 3% lower than that of the as-built bridge after the installation of the disk lower, respectively. Also, the second and third frequencies were 7 and 15% lower, respectively. The disk bearings increased the vertical displacement of the bridge, but the pure displacement, excluding the disk deformation, did not vary. The vertical acceleration did not increase when the disk bearing was installed, with trains running. The shear pin in the disk bearing reduced the lateral displacement and the acceleration of the bridge.

Redundancy Evaluation of the Composite Two Steel Plate-Girder Bridges (강합성 플레이트 2-거더교의 여유도 평가)

  • Park, Yong-Myung;Joe, Woom-Do-Ji
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4A
    • /
    • pp.611-620
    • /
    • 2006
  • The composite two plate-girder bridges are generally defined as a non-redundant load path structure because the bridge can collapse if one of the two girders is seriously damaged by a fatigue crack. In this paper, a numerical study on the evaluation of the after-fracture redundancy of the composite two-girder bridges was accomplished. The evaluation has been performed on the simple and three-span continuous bridges with I-section cross beams which serve as transverse bracing, and with or without the bottom lateral bracing system. The load carrying capacities of the intact and damaged bridges with or without lateral bracing were evaluated from material and geometric nonlinear analysis, respectively and the redundancy was evaluated for each case. It was acknowledged from the analytical results that both simple and continuous intact two-girder bridges have sufficient redundancy even without lateral bracing, but it takes an important role to improve the redundancy of damaged bridges.

Maintenance and Dynamic Behavior of Advanced Spherical Bearings under Railway Open-Steel-Plate-Girder Bridges (판형교에서 개량된 스페리칼받침의 유지보수 및 동적 거동)

  • Choi, Eun-Soo;Lee, Hee-Up;Lee, Seung-Yong
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.2
    • /
    • pp.165-175
    • /
    • 2008
  • Line type rigid bearings for Open-Steel-Plate-Girder railway bridges have several problems in service, and they are unstable structurally. A series of lateral resistance tests were performed for a retrieved line type bearing. A spherical bearing with advanced maintenance-capability and a device to resist the up-lift was developed and replaced the existing ones. An experiment of maintenance for a new spherical bearing under real Open-Steel-Plate-Girder bridge was conducted and their good maintenance performance was proved. Also, a test against up-lift was performed for the bearing. The dynamic behavior of the bridge was measured and analyzed for the two cases of the existing and replaced bearings. Therefore, the suitability of the new spherical bearings on the railway bridge was improved.

Dynamic Behavior of External Post-tensioned Non-ballast Steel Plate Girder Railway Bridge (외부 후 긴장된 무도상 철도 판형교 동적 거동)

  • Park, Yong Gul;Park, Young Hoon;Choi, Dong Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.3A
    • /
    • pp.315-322
    • /
    • 2008
  • The present study applied the external post tensioning reinforcement method for reinforcing a non-ballast steel plate girder railway bridge, and the effects of the strength of tendons and the level of post-tensioning force on the dynamic behavior are experimented and analyzed. According to the results of this study, the natural frequency was increased by the strength of tendons but it was decreased by the rise of post-tensioning force and as a consequence the introduction of post-tensioning force decreased natural frequency slightly. It was analyzed that further study is need to establish the exact relations between post-tensioning force and natural frequency. In addition, it was found that the dynamic displacement, dynamic bending stress and vertical acceleration were decreased by the external post-tensioning. On the other hand, external post-tensioning increased horizontal acceleration by up to 20%, which was around 70% of vertical acceleration. This needs further study.

Experimental Study on the Composite Bridge Deck of Hollow Section (중공단면 복합소재 교량 바닥판의 시험을 통한 구조적 특성 분석)

  • Lee, Sung-Woo;Kim, Byung-Suk;Hong, Kee-Jeung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.4 s.74
    • /
    • pp.325-335
    • /
    • 2006
  • In this paper, flexural test, girder-connection test and barrier-connection test for the pultruded composite bridge deck of hollow section, were carried out and its structural characteristics were evaluated. In the flexural test specimen, deflection was measured at center of the span and strains were measured at various locations to see the structural behavior up to the failure. In addition, finite element analysis was performed for the flexural test specimen and the results were compared with experiments, and load carrying capacity was evaluated. Also, field load test was conducted for the demonstration plate girder bridge and other field applications were described.

A Study of Fabrication and Strengthening of Plate Girder (판항교제작(鈑桁橋製作) 및 보강(補强)에 관한 연구(硏究))

  • Suh, Young Kap
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.3 no.3
    • /
    • pp.39-51
    • /
    • 1983
  • Increasing of load on the highway bridge necessitate the strengthening of load capacity of bridge by some method. The method of strengthening is the usage of pre-stressing high tensile steel line. Having finished pre-stressing work, line is anchored both end, then it composed a member of bridge structure when loading. This paper includes the method and mechanism of strengthening of I-beam span(same originality of plate girder), could be summerized as following; (a) Simple girder, 2 span and 3 span continuous girder increasing the load capacity by more than 80 % for concentrated load. (b) For uniformly distributed load, when all span loaded, load capacity is increase more than 80% to 100% except 3 span continuous.

  • PDF

Redundancy of the Composite Twin Steel Plate Girder Bridgeaccording to the Dimension and Spacing of Cross Beams (강합성 플레이트 2-거더교의 가로보 제원 및 설치 간격에 따른 여유도 평가)

  • Park, Yong Myung;Joe, Woom Do Ji;Baek, Sung Yong
    • Journal of Korean Society of Steel Construction
    • /
    • v.18 no.2
    • /
    • pp.137-146
    • /
    • 2006
  • In this paper, a numerical study on the evaluation of the redundancy according to the dimension and spacing of cross beams in the composite twin steel plate girder bridges that are generally recognized as a non-redundant load path structures, has been performed. Specifically, a two-lane three-span continuous (40+50+40m) bridge with I-section cross beams which serve as cross bracing, and without a lateral bracing were considered. The material and geometric nonlinear analyses were conducted to evaluate the ultimate loading capacity of the intact and damaged bridge in which one of the two girders is seriously fractured. Through the numerical analyses, it was recognized that there is little difference in redundancy according to the variation of the dimension and spacing of the cross beams for both intact and damaged bridges.