• 제목/요약/키워드: Plate Fin

검색결과 177건 처리시간 0.022초

태양열 공기난방기에서 핀의 형상에 따른 열전달 성능 평가 (Research on Thermal Performance by Different Fins in a Solar Air Heater)

  • 최휘웅;홍부표;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제33권6호
    • /
    • pp.85-91
    • /
    • 2013
  • It is essential to reduce the amount of fossil fuel because facing with the natural problem such as a global warming. To achieve this goal, many of interests in the use of renewable energy is growing. Especially, as one of these renewable energy systems, a solar air heater invention has been conducted for enhancing the efficiency of solar air heater. According to this trend, scale-down sized experiment apparatus was constructed and performed for searching a proper fin and confirming the heat transfer performance by fin shape on constant heat condition to enhance efficiency of solar air heater. In this experiment, heat gain, convection heat transfer coefficient, number of transfer units, Nusselt number, Reynold's number, friction factor, performance factor were investigated in order to evaluate the thermal characteristics based on the real data obtained. By comparison with the each fin performance, a zigzag shape keeping a right angle to the plate had the highest value among them.

차량 연비개선을 위한 자동변속기유 열교환기에 대한 실험적 연구 (Experimental Study on Auto-Transmission Fluid Heat Exchanger for Improving Vehicle Fuel Efficiency)

  • 장충만;이용규;강병동;유재석;이종화;김현정;김동권
    • 대한기계학회논문집B
    • /
    • 제35권9호
    • /
    • pp.947-954
    • /
    • 2011
  • 차량에서 구동계의 의한 손실은 전체 연료 소비 손실에서 약 4%를 차지하며 그 중에서도 자동변속기는 구동계 손실에 큰 영향을 끼친다. ATF W/C 열교환기는 근래에 관심이 높아지고 있는 부품인데, 자동변속기 윤활유의 온도를 적정한 상태로 유지시켜 줌으로서 연비 개선 효과를 얻을 수 있다. 본 연구에서는 ATF W/C 열교환기 단품 특성을 실험적으로 파악하고, ATF W/C 열교환기가 실제 차에 장착되었을 때의 연비 개선 효과를 살펴보았다. 본 연구에서는 실험을 통하여 ATF 와 냉각수의 온도와 유량에 대한 유용도를 파악하고 유용도를 예측하기 위한 상관식을 도출하였다. MATLAB의 Simulink 프로그램을 통하여 실험의 결과를 바탕으로 ATF W/C 열교환기 유무에 따른 연료 소모량을 비교 하여 연비 개선 효과를 분석하였다. 그 결과 ATF W/C 열교환기가 장착된 자동차는 0.992% 연비 개선 효과가 나타났다.

핀-핀 형 또는 판-판 형 전극에 인가된 AC 전기장이 에틸렌 정상 확산 화염 Soot 입자 배출에 미치는 영향 (Effects of AC Electrostatic Field Applied to fin-to-Pin/Plate-to-Plate Electrodes on Soot Reduction in a C2B4 Normal Diffusion Flame)

  • 이재복;황정호
    • 대한기계학회논문집B
    • /
    • 제26권8호
    • /
    • pp.1062-1068
    • /
    • 2002
  • In our previous study, it was proven that the mean size and the total number concentration of carbon soot particles emitted from a $C_2$H$_4$ normal diffusion flame decreased when a DC corona was discharged to pin-pin electrodes. In this work the effect of AC corona discharge on soot emission was investigated and compared with that of DC corona discharge. For the pin-pin electrodes the size of soot particles and the number concentration decreased by the AC voltage. There were only slight changes in size distribution with frequencies, while the magnitude of applied voltage was constant. When the electric field was applied to plate-plate electrodes, the size and the number concentration also decreased with the applied AC voltages. For applied voltages above 2kV the effect of frequency increase on the soot emission was effective.

표면처리를 이용한 단일진공관과 기존 이중진공관 태양열집열기의 성능비교 연구 (Study on Performance Comparison for Solar Collectors with Single Evacuated Tube using Surface Treatment and Commercial Double Evacuated Tube)

  • 전태규;양영준;이경희;안영철
    • 한국기계가공학회지
    • /
    • 제12권5호
    • /
    • pp.149-156
    • /
    • 2013
  • The performances of solar collectors with single and double evacuated tube were experimentally compared. The solar collector with single evacuated tube using surface treatment in this study consists of radiation fin, heat pipe, absorber plate, glass tube, cap and regulating valve, and so on. Surface treatment was conducted for heat pipe and absorber plate with black chrome plating and copper black coating. As the results, the performance of solar collector with single evacuated tube using surface treatment showed good results compared that of double evacuated tube. Absorber plate played a positive role in performance and showed increase of about 28%. Further performance depends on vacuum degree and vacuum degree has to be considered economical efficiency in solar collector.

분할된 핀붙이 전열면상에서의 얼음의 용융 (Melting of ice on the heating plate with split fins)

  • 홍희기;김무근
    • 설비공학논문집
    • /
    • 제12권1호
    • /
    • pp.67-74
    • /
    • 2000
  • One of the important application of a contact melting process is a latent thermal energy storage owing to its high heat flux. In some previous works, the split fins have been employed in order to enhance the melting speed. In the present work, the close contact melting was experimentally investigated using an ice as specimen for both split and non-split fins. It was shown that the contact melting by split fins increases the melting rate compared to that of non-split ones.

  • PDF

핀 부착 열교환기에서 습증기(mist)발생 메커니즘의 파악을 위한 실험적 고찰 (An Experimental Study on Understanding of Production Mechanism of a Mist from Fin Adhesion heat Exchanger)

  • 최권삼
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2000년도 춘계학술대회 논문집(Proceeding of the KOSME 2000 Spring Annual Meeting)
    • /
    • pp.146-152
    • /
    • 2000
  • As an improvement in the standard of living and economic growth the demand for air conditioning equipment is increasing rapidly. Nowadays air conditioning equipments are being used for industry large building house and car. Thess equipments was concentrated on improving heat efficiency of economic aspects while they design heat exchanger for cooling and heating,. These air conditioning equipments using heat exchanger cause a discomfort to user due to generating mist at the beginning of operating. Therefore the user demand air of high class and quality. In this experimental study to acquire elementary data for development of heat exchanger which be able to supply air of high quality that is to say possess a restraint effect of mist generation. We estimate an effect on cooling plate kind supply air velocity supply air temperature cooled plate temperature and supply air relative humidity which have an influence on outlet air condition of heat exchanger.

  • PDF

냉장고용 롤-플레이트형 휜-관 열교환기의 성능에 관한 연구 (A Study of Performance of Roll-plate type fin-tube Heat Exchanger for the Refrigerator)

  • 안성준;김종수;권오붕;박영종;하영주;최상조
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2292-2297
    • /
    • 2008
  • Recently, a study on condensers for refrigerators has focused on new model which will cost less and will be more efficient. Some widely used condensers for domestic refrigerators are wire-and-tube type condenser, hot-wall type condenser, and spiral type condenser. Some companies which use the spiral type condenser at the moment try to develop a new type condenser which will cost less and will be as efficient as the spiral type. The new type condenser consists of a steel tube, steel plates and louver fins attached to the tube. The tube and the plate are bent into a single-passage serpentine shape.

  • PDF

이상유동 해석을 통한 브레이징 판형 응축기 설계 연구 (Design Study of a Brazed Plate Heat Exchanger Condenser Through Two-Phase Flow Analysis)

  • 황대중;오철;박상균;지재훈;방은신;이병길
    • 신재생에너지
    • /
    • 제18권2호
    • /
    • pp.73-81
    • /
    • 2022
  • This study was aimed at designing a condenser, as a component of the organic Rankine cycle system for ships. The condenser was manufactured through press molding to achieve a bent shape to enhance the heat transfer performance, considering the shape of the heat transfer plate used in a brazing plate heat exchanger. The heat transfer plate was made of copper-nickel alloy. The required heat transfer rate for the condenser was 110 kW, and the maximum number of layers was set as 25, considering the characteristics of high-temperature brazing. Computational fluid dynamics techniques were used to perform the thermal fluid analysis, based on the ANSYS CFX (v.18.1) commercial program. The heat transfer rate of the condenser was 4.96 kW for one layer (width and length of 0.224 and 0.7 m, respectively) of the heat transfer exchanger. The fin efficiency pertaining to the heat transfer plate was approximately 20%. The heat flow analysis for one layer of the heat exchanger plate indicated that the condenser with 25 layers of heat transfer plates could achieve a heat transfer rate of 110 kW.

평판형 예혼합 버너의 다양한 화염면 매질 및 열교환기에 따른 연소 특성 (A Study on the Combustion Characteristics of Flat-Plate Premixed Burner for Various Flame Surface Media and Heat Exchangers)

  • 조은성;박창권;최경석
    • 대한기계학회논문집B
    • /
    • 제35권10호
    • /
    • pp.1033-1040
    • /
    • 2011
  • 예혼합 버너는 높은 효율과 낮은 배기 때문에 가정용 보일러 버너 시스템에 매우 강력한 버너이다. 일반적으로 가정용 보일러 버너는 내부에 농후한 예혼합 불꽃으로 구성하고 연료는 2차공기의 공급에 의하여 완전연소 되는 분젠 버너를 이용한다. 이것은 상대적으로 긴 불꽃 길이와 높은 과잉공기비에서 작동하기 때문에 높은 효율을 갖는 소형 보일러에 적용하기 어렵다. 이 논문에서 메탈 화이버, 세라믹, SUS 핀과 같은 매질을 사용하는 예혼합 연소 버너의 특징을 실험하였다. 특히, 표면 매질의 비반응 유동 특성은 버너 표면 전체의 유동 속도를 측정하고 조정하였다. 연소 실험은 화염 사진과 화염 온도 측정에 의하여 수행되었다. CO와 NO는 다양한 과잉 공기비와 열량값에 대하여 버너 표면 매질, 연소실, 열교환기의 특성을 측정하고 평가하였다.