• 제목/요약/키워드: Plate Chamber

검색결과 266건 처리시간 0.024초

가압 분무실내 스프레이 충돌판에서 나타나는 비정상 열전달 측정에 관한 연구 (An Experimental Study on Unsteady Heat Transfer of Spray-Impinging Plate in a Pressurized Chamber)

  • 조창권;이열;구자예
    • 대한기계학회논문집B
    • /
    • 제24권1호
    • /
    • pp.60-67
    • /
    • 2000
  • An experimental investigation on transient heat transfer phenomena of impinging diesel-spray on a flat plate in a pressurized chamber is carried out. A diesel spray is injected from a single-hole nozzle and impinges to a heated flat plate in the chamber. A fast-response thermocouple installed in the top surface of the plate measures the transient variation of surface temperature of the plate under various conditions of the chamber pressures. Utilizing the semi-infinite model, the temporal variation of the heat flux on the plate is determined. Effects of various parameters, such as vertical distances between the nozzle and the plate, radial distances from the injection-axis, and the chamber pressures, on the heat flux characteristics of impinging diesel-spray are studied.

두 개의 챔버를 갖는 마이크로 버블펌프의 개발 (Development of having double-chamber in micro-bubble pump)

  • 최종필;박대섭;반준호;김병희;장인배;김헌영
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1186-1190
    • /
    • 2003
  • In this paper, a valveless bubble-actuated fluid micropump was has been developed and its performance was tested. The valveless micropump consists of the lower plate, the middle plate, the upper plate and a resistive heater. The lower plate includes the nozzle-diffuser elements and the double-chamber. Nozzle-diffuser elements and a double-chamber are fabricated on the silicon wafer by the DRIE(Deep Reactive Ion Etching) process. The lower plate also has inlet/outlet channels for fluid flow. The middle plate is made of glass and plays the role of the diaphragm. The chamber in the upper plate is filled with deionized water, and which contacts with the resistive heater. The resistive heater is patterned on a silicon substrate by Ti/Pt sputtering. Three plates and the resister heater are laminated by the aligner and bonded in the anodic bonder. Since the bubble is evaporated and condensed periodically in the chamber, the fluid flows from inlet to outlet with respect to the diffusion effect. In order to avoid backflow, the double chamber system is introduced. Analytical and experimental results show the validity of the developed double-chamber micropump.

  • PDF

반도체용 핫플레이트 챔버 내 자연대류가 핫플레이트 표면 온도 균일도에 미치는 영향 (Effects of Natural Convection Cells on Temperature Uniformity in Hot Plate Chamber for Wafer Baking Process)

  • 박준수;권현구;조형희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2512-2517
    • /
    • 2007
  • Effect of natural convention for hot plate surface temperature uniformity was studied by experiments that were adjusted height of chamber and temperature difference. The hot plate chamber is composed of the hot plate and the upper heater and adiabatic vertical wall. The hot plate diameter is 220mm and maintains temperature at $150^{\circ}C$. Flow pattern compares with surface temperature and confirms that natural convection affects on temperature uniformity of hot plate surface. In case, temperature non-uniformity of hot plate surface is due to heater pattern, lots of weak and small flow cells more improve temperature uniformity than stronger flow cells or non-developing flow cell. Improve temperature uniformity $1.2^{\circ}C$ when developing weak and small flow cells.

  • PDF

평행평판형 이온함의 두 전극간의 간격 변화에 따른 유효측정점에 관한 연구 (Study on Effective Point of Measurement for Parallel Plate Type ionization Chamber with Different Spacing)

  • 신교철;윤형근
    • 한국의학물리학회지:의학물리
    • /
    • 제13권2호
    • /
    • pp.55-61
    • /
    • 2002
  • 본 연구는 제작된 방사선 측정시스템을 평가하기 위한 방법중의 하나인 유효측정점을 명확히 정하기 위하여 실행되었다. 일반적으로 원통형이나 두 전극간의 간격이 매우 작은 평행평판형 이온함의 경우 유효측정점은 잘 정의 되어있다. 그 정의에 의하면 그리 크지 않은 체적을 갖는 평행평판형 이온함의 유효측정점은 방사선이 입사되는 윗면의 바로 아래로 정의한다고 되어있다. 그러나 본 연구에서 제작한 이온함과 같이 두 전극간의 간격을 비교적 크게 할 경우 위의 정의는 더 이상 유효하지 않을 수도 있을 것으로 생각되어 평행평판형 이온함의 두 전극간의 간격을 3, 6, 10 mm로 하여 체적이 0.9, 1.9, 3.1 cc로 비교적 크게 한 경우에 그 유효측정점의 변화를 검토하고자 하였다. 실험은 의료용 선형가속기로부터 발생가능한 광자선 6, 10 MV와 전자선 6, 12 MeV에 대하여 시행되었으며, 방법은 이온함의 buildup의 두께를 증가시켜가면서 방사선의 측정선량이 최대가 되는 깊이를 조사하였다. 그 결과 광자선과 전자선의 경우 조사된 모든 에너지에 대하여 그 정도의 차이는 있으나 전반적으로 이온함의 체적이 커짐에 따라서 즉, 두 전극간의 간격이 멀어짐에 따라서 유효측정점이 이온함의 윗면에서부터 이온함의 중심 쪽으로 이동하는 경향을 보였다. 그 정도는 이온함 체적의 크기가 커질수록 더 크게 이동하는 양상을 보였다. 이와 같은 결과로 볼 때 평행평판형 이온함의 경우는 두 전극간의 간격이 어느 정도 큰 경우에는 유효측정점이 변하게 됨으로 이온함의 체적에 따라서 그 유효측정점을 조사할 필요가 있다고 생각된다.

  • PDF

가스보일러 연소실 공기분배판의 기하학적 형상에 따른 유동특성 해석 (Flow Characteristic Analysis in Accordance with Geometrical Modification of Air Distribution Plate in Gasboiler Combustion Chamber)

  • 김재중;손영갑;장석원;유동수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.859-864
    • /
    • 2000
  • This paper reports a numerical flow characteristic analysis in gas boiler combustion chamber. The numerical results with simplification and assumptions were found within 30% of the experiment. A lot of geometrical modification has been invested in attempt to obtain the uniform flow in the combustion chamber exit. As a result, the velocity magnitude of the combustion chamber is relate with the hole size in air distribution plate. The velocity uniformity of the combustion chamber is relate with the number of holes and location in air distribution plate.

  • PDF

마이크로 정량펌프의 유동해석과 작동성능 평가 (The Flow Analysis and Evaluation of the Peristaltic Micropump)

  • 박대섭;최종필;김병희;장인배;김헌영
    • 한국정밀공학회지
    • /
    • 제21권2호
    • /
    • pp.195-202
    • /
    • 2004
  • This paper presents the fabrication and evaluation of mechanical behavior for a peristaltic micropump by flow simulation. The valve-less micropump using the diffuser/nozzle is consists of the lower plate, the middle plate, the upper plate and the tube that connects inlet and outlet of the pump. The lower plate includes the channel and the chamber, and the plain middle plate are made of glass and actuated by the piezoelectric translator. Channels and a chamber on the lower plate are fabricated on high processability silicon wafer by the DRIE(Deep Reactive Ion Etching) process. The upper plate does the roll of a pump cover and has inlet/outlet/electric holes. Three plates are laminated by the aligner and bonded by the anodic bonding process. Flow simulation is performed using error-reduced finite volume method (FVM). As results of the flow simulation and experiments, the single chamber pump has severe flow problems, such as a backflow and large fluctuation of a flow rate. It is proved that the double-chamber micropump proposed in this paper can reduce the drawback of the single-chamber one.

고선량률(HDR) 근접치료의 동위원소 Ir-192에 대한 측정방법에 관한 고찰 (A Study on Calibration Procedures for Ir-192 High Dose Rate Brachytherapy Sources)

  • 백태성;이승욱;나수경
    • 대한방사선치료학회지
    • /
    • 제19권1호
    • /
    • pp.19-26
    • /
    • 2007
  • 목 적: Ir-192 고선량율 근접치료(HDR Brachytherapy)선원에 대한 다양한 측정절차의 효율을 서로 비교할 것이며, 측정 장비의 추가 구입 없이 대안으로 새롭게 만든 PMMA (polymethylmethacrylateplastics: $C_5H_8O_2$) plate phantom에 대한임상에서의 적합성과 유용성을 알아 보았다. 대상 및 방법: 세 가지 형태(Well type chamber, Source calibration jig, PMMA plate phantom)의 측정 시스템을 이용하여 측정값을 비교하였다. Source calibration jig와 PMMA plate phantom을 사용 했을 때에는 Farmer type chamber를 이용하여 측정하였으며, 각각 5회씩 측정하여 제조업체의 측정치와 비교하였다. 또한 새로운 선원을 교환 할 때마다 제조업체로부터 선원과 함께 제공되는 제조업체의 측정치를 본 연구의 측정치와 비교하여 방사능의 정확도를 평가 하였다. 결 과: Well type chamber, Source calibration jig, PMMA plate phantom를 사용한 Ir-192 선원의 측정결과 제조업체 측정치와의 상대오차에 대한 RMS (Root Mean Square)값은 Well type chamber에서 0.6%, Source calibration jig에서 1.57%, PMMA plate phantom에서는 2.1%를 나타내었다. 또한 평균 오차에 대한 편차는 Well type chamber에서 $-0.2{\pm}0.5%$, Source calibration jig에서 $0.97{\pm}1.23%$, PMMA plate phantom에서는 $-0.89{\pm}1.87%$를 나타내었다. 결 론: 본 연구를 통해 실험한 세 가지 형태(Well type chamber, Source calibration jig, PMMA plate phantom)의 측정 시스템의 결과에서 나타난 것처럼, Well type chamber를 이용한 측정결과가 가장 우수하게 나타났다. 또한 측정 장비를 구입하지 않고 대안으로 새롭게 만든 PMMA plate phantom의 결과 권고안 ${\pm}5%$를 초과하지 않으므로 임상에서 유용하게 사용 할 수 있을 것이라 생각되어진다.

  • PDF

냉동 건조 조건에 따른 이유식용 당근의 품질 특성 (Quality Attributes of Carrot Pieces for Baby Foods Prepared under Different Freeze Drying Conditions)

  • 김혜경;서동순;이영춘;김광옥
    • 한국식품과학회지
    • /
    • 제34권5호
    • /
    • pp.799-804
    • /
    • 2002
  • 본 연구에서는 생후 9-12개월 된 영아에게 재 수화시킨 후 숟가락으로 떠서 먹일 수 있는 비교적 입자가 큰 알갱이 형태의 이유식용 냉동건조 당근의 최적 건조조건을 결정하였다. 이를 위하여 가열판 온도와 압력을 달리하면서 당근을 냉동 건조시킨 후, 냉동건조시간과 물리적 특성 및 관능적 특성을 측정하였다. 냉동건조시간은 가열판 온도가 높고 압력이 높을수록 감소하였다. 관능적 특성 중 당근의 색, 연한 정도 및 당근의 향미는 가열판 온도가 감소함에 따라 증가하였다. 또한 압력은 냉동 건조 당근의 관능적 특성에 큰 영향을 주지 않았다. 이유식용 냉동 건조 당근의 제조 시 바람직한 특성을 가능한 한 최대로 하면서 건조시간은 가능한 한 최소로 할 수 있는 최적조건은 가열판 온도는 $43^{\circ}C$, 압력은 700 micronHg로 결정되었다.

Use of Cylindrical Chambers as Substitutes for Parallel-Plate Chambers in Low-Energy Electron Dosimetry

  • Chun, Minsoo;An, Hyun Joon;Kang, Seong-Hee;Cho, Jin Dong;Park, Jong Min;Kim, Jung-in
    • 한국의학물리학회지:의학물리
    • /
    • 제29권1호
    • /
    • pp.16-22
    • /
    • 2018
  • Current dosimetry protocols recommend the use of parallel-plate chambers in electron dosimetry because the electron fluence perturbation can be effectively minimized. However, substitutable methods to calibrate and measure the electron output and energy with the widely used cylindrical chamber should be developed in case a parallel-plate chamber is unavailable. In this study, we measured the correction factors and absolute dose-to-water of electrons with energies of 4, 6, 9, 12, 16, and 20 MeV using Farmer-type and Roos chambers by varying the dose rates according to the AAPM TG-51 protocol. The ion recombination factor and absolute dose were found to be varied across the chamber types, energy, and dose rate, and these phenomena were remarkable at a low energy (4 MeV), which was in good agreement with literature. While the ion recombination factor showed a difference across chamber types of less than 0.4%, the absolute dose differences between them were largest at 4 MeV at approximately 1.5%. We therefore found that the absolute dose with respect to the dose rate was strongly influenced by ion-collection efficiency. Although more rigorous validation with other types of chambers and protocols should be performed, the outcome of the study shows the feasibility of replacing the parallel-plate chamber with the cylindrical chamber in electron dosimetry.

The Evaluation of Multiplane-Parallel Chamber Using Crystal Plate as Ionization Medium for Therapeutic Radiation Beams

  • Young W. Vahc;Park, Kyung R.;Kim, Sookil;Chul W. Joh;Kim, Tae H.
    • 한국의학물리학회지:의학물리
    • /
    • 제9권1호
    • /
    • pp.29-35
    • /
    • 1998
  • There has been necessity of an air free ionization chamber using the gold-crystal-aluminium plates, henceforth called the crystal chamber. The crystal chamber formed of parallel plates is very small in size and has more response for absorbed dose of therapeutic radiation beams. The gold plate on the crystal facing the photon and electron beam acts as an intensifier of signals and crystal plate as an ionization medium respectively. Both the copper guard ring and the aluminum collecting electrode are connected to an electrometer. Using high energy photon (6, 15 MV) and electron (9, 12, 15, 18 MeV) beams, the responses of the crystal chamber are evaluated against a PTW Farmer-type chamber at a field size of 10${\times}$10cm$^2$ and 100 cm SSD. The responses of crystal chamber for therapeutic radiation electron and photon beams are greater in magnitude by several order than Farmer. The crystal chamber has good linearity without correction factor C$\_$t,p/ with respect to the signals, a reading reproduction with good accuracy and precision less than 0.5%, and has other useful functions in measuring radiation beams.

  • PDF