• Title/Summary/Keyword: Plastic film type

Search Result 104, Processing Time 0.019 seconds

Development of a Strain Gauge for Sensing Large Strain (대 변형 감지용 스트레인게이지 개발)

  • Lee, Young Tae;Cho, Seung Woo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.13 no.4
    • /
    • pp.33-36
    • /
    • 2014
  • In this paper, a carbon strain gauge for large strain was developed. The carbon strain gauge was fabricated by forming PCB and antenna pattern using Cu/Ni/Au film and carbon resistor pattern using screen printing process on plastic film substrate. It was possible to develop low-cost disposable strain gauge since the carbon paste was cheap and the fabrication process was simple. The wireless communication type carbon strain gauge was fabricated by integrating signal processing circuit, antenna and power all together on the same substrate as a strain gauge. The wireless communication type carbon strain gauge has a merit of being available immediately at the spot without any particular system.

Development of a Tractor Attached Round Bale Wrapper(II) - Manufacturing of proto-type bale wrapper and its performance test (트랙터 견인형 원형 베일 랩퍼의 개발(II) - 시작기의 제작 및 성능 평가 -)

  • Kim, H. J,;Park, K. K.;Myung, B. S.;Choi, J. S.;Kim, T. W.;Jang, C.;Hong, D. H.
    • Journal of Biosystems Engineering
    • /
    • v.27 no.3
    • /
    • pp.195-202
    • /
    • 2002
  • In order to make a winter cereal wrap silage, a tractor attached round bale wrapper was developed locally. Its specific structure and various functions were reported in the last submitted paper. In this study a control system of bale wrapper combining with the actuators of various processes was developed to make round bale wrapper compatible in the field. Also. its performance was tested by making the rye round bale. The results can be summarized as fellow. 1. The field capacity of round bale wrapping was investigated around 0.5 ha/hr, and the operating time of bale wrapper was about 3 min for each 500kg round bale 2. Plastic film which has maximum elongation rate of 796% was stretched to 150∼170% of original length and was lessened to 80∼90% of original width. 3. In the quality test of bale produced by developed bale wrapper, there was no significant changes of moisture contents if it was wrapped more than 4 layers of 25 ㎛-plastic film. 4. Also. temperature of the wrapped bale was about 33$\^{C}$ in the beginning of fermentation and was stabled to 26∼29$\^{C}$ during one month or more storage. Therefore, wrapping performance of the developed bale wrapper was properly.

Growth of Green Pepper(Capsicum annuum L.) in a Plastic Greenhouse Covered with Anti-dropping Plasma Film (방적성 Plasma 처리 필름으로 피복된 플라스틱온실의 풋고추 생육)

  • Chun, Hee;Kim, Kyung-Je;Kim, Jin-Young;Kim, Hyun-Hwan;Lee, Si-Young
    • Journal of Bio-Environment Control
    • /
    • v.9 no.3
    • /
    • pp.156-160
    • /
    • 2000
  • The Plasma film treated with a high electric voltage was developed to enhance flow down of condensation drops on inside plastic film. Arch type greenhouse framed with iron pipe of 25mm diameter defand 1.5mm thickness were covered with either the developed plasma film or surfactant film(control). Green pepper seedlings raised for 40 days in plug trays were transplanted at a density of 110cm by 30cm in each greenhouse. The mount of condensational water on film surface, generated by 7$0^{\circ}C$ water bath chimney systems and flew down, was collected and measured. The amount of collected water after 150 minutes was 2.56 mL.100c $m^{-2}$ and 0.94mL.100c $m^{-2}$ , respectively, in the plasma film and surfactant film-covered greenhouses. The amount of condensational water drops attached on the cover at 08:20 a.m. at 60 days filter covering was 0.34mL.100c $m^{02}$ and 0.32mL.100c $m^{-2}$ , respectively, in the plasma film- and surfactant film-covered greenhouses. Solar irradiance transmitted into greenhouse was 2.0% higher in the greenhouse covered with the plasma film tan that in the greenhouse covered with the surfactant film. Air temperature in the plasma film-covered greenhouse was higher than the surfactant film-covered greenhouse by 0.5$^{\circ}C$. However, there was no difference in relative humidity between the two greenhouse. Plant height, leaf area, dry weight and early yield showed no significant differences.s.

  • PDF

Design of the Platform for a Nanoparticle thin Film Thermoelectric Device transforming Body Heat into Electricity (체온 이용이 가능한 나노입자 박막 열전소자의 플랫폼 개발연구)

  • Yang, Seunggen;Cho, Kyoungah;Choi, Jinyong;Kim, Sangsig
    • Journal of IKEEE
    • /
    • v.20 no.2
    • /
    • pp.174-176
    • /
    • 2016
  • In this study, we maximize the temperature difference between the ends of a HgTe nanoparticle(NP) thin film on a thermoelectric platform with a through-substrate via. The thermoelectric characteristics of the HgTe NP thin film show p-type behavior and its Seebeck coefficient is $290{\mu}V/K$. In addition, we demonstrate the possibility of wearable thermoelectric devices transforming body heat into electricity from through-substrate via thermoelectric platforms on human skin.

A simple device to measure the relative rate of heat loss through plastic coverings from greenhouse (그린하우스의 프라스틱 피복재를 통한 상대적 열손실 속도를 측정하는 간단한 장치)

  • Jung, Jin;Park, Byung-Bin
    • Korean Journal of Environmental Agriculture
    • /
    • v.8 no.2
    • /
    • pp.142-147
    • /
    • 1989
  • In this report, we set up a simple device which enabled us to obtain data useful to estimate the relative capacity of thermal energy retention of greenhouse built with various plastic coverings. A box($20cm{\times}20cm{\times}30cm$) framed with flexiglass at the edges and covered with thin plastic films was made, in which were placed a thermostat-controlled nichrom wire heater and a thermal probe made of thermister to monitor temperature changes. A wheaston-bridge type transducer and a chart recorder were used to record the changes of temperature inside the box The data obtained by using the device showed that the relative rate of heat toss through plastic films with identical thickness decreased in the order of PE film>EVA film>PVC film and that IR additives such as fine silica gel improved the insulating power of plastic films. This observations are in well accord with general information, demostrating the feasibility of the device in usefulness for the purpose of screening of various commercial plastic coverings.

  • PDF

Quality Assessment by MSW Type for High-quality and Low-pollution RDF (고품질·저오염 RDF 생산을 위한 생활폐기물 성분평가)

  • Ham, Kwang-Joon;Oh, Geun-Chan;Park, Young-Han;Kim, Min-Su;Kim, Joon-Hyun
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.6
    • /
    • pp.453-460
    • /
    • 2009
  • In order to provide fundamental data for developing high-grade(high-quality and low-pollution) Refuse Derived Fuel(RDF), we analyzed caloric value and HCl content by Municipal Solid Waste(MSW) type. The caloric value was analyzed using calorimeter and HCl content was analyzed using mercury(II) thiocyanate method. In case of paper type the caloric value was 3,060~3,608kcal/kg and the HCl content was 239~6,135ppm. In case of vinyl-plastics the caloric value was 5,946~9,888kcal/kg and the HCl content was 429~455,771ppm. According to the result of quality assessment by MSW type, the calroric value of vinyl-plastics type was showed higher than that of paper type and in case of HCl content the paper type was showed lower than vinyl-plastics type. So, We mixed paper and plastic wastes. The caloric value of mixed MSW(paper and plastics) was 5,046~9,125kcal/kg and the HCl content was 239~6,135ppm. Also, The caloric value of packaging waste(film-plastics) was 5,982~8,045kcal/kg. Therefore It is possible to develop high-grade Refuse Derived Fuel through suitable mixing of paper and plastic in municipal solid waste.

Effects of the Morphology of Secondary Phases and Carbon Content on the Plastic Deformation of TRIP steel (변태유기소성강의 소성변형에 미치는 2차상의 형상과 고용탄소의 영향)

  • 홍승갑
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.03b
    • /
    • pp.116-119
    • /
    • 1999
  • The effects of secondary phase morphology and carbon content on the plastic deformation of 0.2C-1.5Si-1.5mn TRIP(TRansformed Induced Plasticity) steel have been investigated at various annealing and bainitic transformation temperatures. The morphology of ferrite and secondary phases was controlled by the annealing temperature and the distribution of secondary phase was controlled by the bainitic transformation temperature. The secondary phase contributed to elongation and/or UTS depending on the ferrite morphology which determined deformation mode simple elongation or rotation of secondary phase along the tensile direction In case of the sample containing the granular type retained austenite the elongation was improved as carbon stabilized the austenite phase. If the film-shape retained austenite in acicular ferrite was dominant however UTS was enhanced as the transformed martensite was hardened by carbon.

  • PDF

Development of Reflection-type Fiber-optic pH Sensor Using Sol-gel Film (졸-겔 필름을 이용한 반사형 광섬유 pH 센서의 개발)

  • Yoo, Wook-Jae;Seo, Jeong-Ki;Jang, Kyoung-Won;Moon, Jin-Soo;Han, Ki-Tek;Park, Jang-Yeon;Lee, Bong-Soo;Cho, Seung-Hyun;Heo, Ji-Yeon;Park, Byung-Gi
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.266-271
    • /
    • 2011
  • A reflection-type fiber-optic pH sensor, which is composed of a pH sol-gel film, plastic optical fibers, a mirror, a light source and a spectrometer, is developed in this study. As pH indicators, a bromthymol blue, a cresol red and a thymol blue are used, and they are immobilized in the sol-gel films. The emitted light from a light source is guided by a fiber-optic Y-coupler and plastic optical fibers to the pH sol-gel film in a pH sensing probe. The pH change in the sensing probe gives rise to a change in the color of the pH sol-gel film, and the optical characteristic of reflected light through the pH sol-gel film is also changed. Therefore, we have measured the spectra of reflected lights, which are changed according to the color variations of the pH sol-gel films with different pH values, by using of a spectrometer. Also, the relationships between the pH values and the intensities of reflected lights are obtained on the basis of the color variations of the pH sol-gel films.

Characteristics of PPF Transmittance and Heat Flow by Double Covering Methods of Plastic Film in Tomato Greenhouse (토마토재배용 플라스틱온실의 이중피복방법에 따른 광합성유효광량자속 투과 및 열관류 특성)

  • Lee, H.W.;Sim, S.Y.;Kim, Y.S.
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.5
    • /
    • pp.11-18
    • /
    • 2010
  • This study was conducted to provide design data for deciding covering method in double layers greenhouse. The variation of photosynthetic photon flux (PPF) and heat flow in air inflated and conventional double layers greenhouse was analyzed. The PPF of air inflated double covering greenhouse was less than that of conventional greenhouse during summer season because the more PPF comes into conventional greenhouse through roof vent which was rolled up for ventilation. The air inflated double layers covering greenhouse was superior to conventional type in the aspect of controlling inside temperature down owing to lower irradiation. The PPF of air inflated greenhouse was greater than that of conventional greenhouse during winter season because the transmittance of conventional greenhouse decreased by dust collected on inside plastic film nearly closed for insulation. Considering the PPF not sufficient for tomato growing in winter, the air inflated double covering system with the greater transmittance was better than conventional covering system. When the inside air of air inflated greenhouse was injected into space between the double layers of covering, the PPF of air inflated greenhouse was much less than the conventional greenhouse because the transmittance of air inflated double covering decreased due to condensation of highly humidified inside air. It was concluded that the more dried outside air should be used for inflating double layers covering. The heat insulation performance of air inflated double covering system was superior to conventional double covering system when comparing the overall heat transfer coefficients for each covering method. However the differences among the overall heat transfer coefficients depending on difference between inside and outside temperatures of greenhouse were great, it is necessary to conduct additional experiment for investigating the overall heat transfer coefficient to design the double layers covering.

The Failure Analysis of Boiler Tube for High Temperature and High Pressure Service (고온고압용 보일러 튜브의 파손 원인분석)

  • Lee, Jong-Hun;Yu, Wi-Do
    • 연구논문집
    • /
    • s.30
    • /
    • pp.121-128
    • /
    • 2000
  • The failed tube received for this study has been used for approximately 10 year at $330^{\circ}C$ in a steam production boiler tube was fractured in the transversed direction to tube length, and fracture mode was typically intergranulas type without the plastic deformation. The fracture surface was covered by the oxide scale formed from the intermal high pressure steam at high temperature. The microstructure was not nearly thermal-degraded during the service. From this result, we can conclude that the oxide film was proferentialy formed into the grainboundary and this grainboundary oxide film was brittle-fractured by the thermal stress in the longitudinal direction to the tube brittle intergranular fracture mode.

  • PDF