• Title/Summary/Keyword: Plastic damage

Search Result 814, Processing Time 0.028 seconds

Vine Growth and Fruit Characteristics of 'Jinok' and 'Campbell Early' Grape as Influenced by Cropping System (재배작형에 따른 포도 '진옥'과 '캠벨얼리'의 수체생육 및 과실 특성 분석)

  • Cheon, Mi Geon;Kim, Yeong Bong;Lee, Sun Yeong;Hong, Gwang Pyo;Jung, Sung Min;Kim, Jin Gook
    • Journal of Bio-Environment Control
    • /
    • v.26 no.3
    • /
    • pp.175-180
    • /
    • 2017
  • This study was conducted for the domestic new cultivar to expand cultivation area and sustainable production. The new domestic cultivar, 'Jinok' and control cultivar, 'Campbell Early', had been investigated on vine growth and fruit quality by different cultivating conditions as open field, rain shelter and unheated plastic house. The growth period of 'Jinok' was faster than 'Campbell Early'. The harvesting date of 'Jinok' was on 13th of Aug. faster than 'Campbell Early' which was on 17th of Aug., and it was on 25th and 29th of Aug. for 'Jinok' and 'Campbell Early' on field cultivation, respectively. The growing length and width of new shoots were similar among the cropping systems. In the result of fruit characteristic evaluation, the soluble solids content of the 'Jinok' and 'Campbell Early' cultivating on the unheated plastic house were $15.4^{\circ}Brix$ and $15.9^{\circ}Brix$, respectively. In the open field condition, those were $15.9^{\circ}Brix$ and $15.8^{\circ}Brix$, respectively. The titratable acidity and chromaticity were similar among the treatments. In the appearance of past and disease, Phomopsis blight was occurred on mid of June and in the end of cultivation period on about early Aug., the damage by Phomopsis blight was the lowest about 14% in the unheated plastic house cultivation on the 'Jinok' cultivar and it was 39% in the open field condition. However, in the open filed cultivation for 'Campbell Early', Phomopsis blight was highly occurred about 49%. During this period, or the end of cultivation, it is necessary for the intensive control.

A Study on the Leakage Protection with Polypropylene Mat in Irrigation Canal (Polypropylene Mat에 의(依)한 용수로(用水路)의 누수방지(漏水防止)에 관(關)한 연구(硏究))

  • Kang, Sin-Up;Kang, Yea-Mook;Cho, Seung-Seup
    • Korean Journal of Agricultural Science
    • /
    • v.6 no.2
    • /
    • pp.166-184
    • /
    • 1979
  • In order to prevent the water loss in the irrigation canal constructed on the sandy gravel layer or on the other highly permeable ground layer, lining has been practiced. Many studies have been done so far on the lining method to prevent the water loss in the irrigation canal and recently studies on the lining with plastic film or polyethylene film were also reported. However, the plastic film or polyethylene film has low strength and is liable to break, and water loss from pin hole caused by contacting with sand or gravel is highly predicted. This study was then conducted to find proper lining and buring method in canal construction of polypropylene mat after coated with vinyl, as one way to overcome the shortcoming frequently observed when plastic or usual polyehtylene film were used. Eventhough rather longer periods of experiments are needed to attain reliable and accurate results on the variation of durability, the durability of asphalt coated area, or on the damage due to freeze after burial or exposure of polypropylene mat, the experiemental results obtained during one year of period are summarized as follows: 1. The curvature at the area between canal bottom and side slope had increased stability and saved consruction cost. The relationship among the variation of curvature, the reduction of polypropylene mat and the reduced amount of soil cutting at each side slope was presented in Fig. 7 through 9. 2. The depth of covering material to protect polypropylene mat was desired to be over 30cm, considering the water depth, side slope, canal cleaning practices, traffic, or back pressure of irrigation period. 3. In order to increase the canal stability and to prevent slope erosion, sandy soil was required, to be placed under ground, and coarse gravel should cover the surface area of canal. 4. The studies on the stability of side slope in the canal should consider the passive area on the bottom and the slope should be about 1 to 2, considering the slope stability, allowable velocity and tractive force. 5. When compared with earth lining, the lining with polypropylene mat coated with vinyl was responsible to save 28% and 37% of canal lining cost, when the soil carrying distances were 500 and 700m. respectively. 6. The water interception was almost completely attained when the polypropylene mat coated with vinyl was used for lining. But further studies were assumed to be necessary for the use of asphalt since the strength of polypropylene mat connected with asphalt will vary with duration.

  • PDF

Comparative evaluation of roughness of titanium surfaces treated by different hygiene instruments

  • Unursaikhan, Otgonbayar;Lee, Jung-Seok;Cha, Jae-Kook;Park, Jung-Chul;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.3
    • /
    • pp.88-94
    • /
    • 2012
  • Purpose: The use of appropriate instruments to clean surfaces with minimal change, is critical for the successful maintenance of a dental implant. However, there is no consensus about the type and methodology for such instruments. The aim of this study was to characterize changes in the roughness of titanium surfaces treated by various scaling instruments. Methods: Thirty-seven identical disks (5 mm in diameter) were investigated in this study. The specimens were divided into eight groups according to the types of instrumentation and the angle of application. Ultrasonic scaling systems were applied on a titanium disk to simulate standard clinical conditions. The equipment included a piezoelectric ultrasonic scaler with a newly developed metallic tip (NS group), a piezoelectric ultrasonic scaler with a conventional tip (CS group), a piezoelectric root planer ultrasonic scaler with a conventional tip (PR group), and a plastic hand curette (PH group). In addition, the sites treated using piezoelectric ultrasonic scaler systems were divided two sub-groups: 15 and 45 degrees. The treated titanium surfaces were observed by scanning electron microscopy (SEM), and the average surface roughness (Ra) and mean roughness profile depth (Rz) were measured with a profilometer. Results: SEM no significant changes in the titanium surfaces in the NS group, regardless of the angle of application. The PH group also showed no marked changes to the titanium surface, although some smoothening was observed. All CS and PR sites lost their original texture and showed irregular surfaces in SEM analysis. The profilometer analysis demonstrated that the roughness values (Ra and Rz) of the titanium surfaces increased in all, except the PH and NS groups, which showed roughness decreases relative to the untreated control group. The Ra value differed significantly between the NS and PR groups (P<0.05). Conclusions: The results of this study indicated that changes in or damage to titanium surfaces might be more affected by the hardness of the scaler tip than by the application method. Within the limitations of this study, the newly developed metallic scaler tip might be especially suitable for peri-implant surface decontamination, due to its limited effects on the titanium surface.

The Development of Pulp Mold Tray for Melon Packaging (멜론 포장용 펄프몰드 난좌 개발)

  • Choi, Seung Ryul;Jung, Hoon;Choi, Dong Soo
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.19 no.3
    • /
    • pp.125-131
    • /
    • 2013
  • In order to protect agricultural products against damage by physical load, various shock absorbing materials is used. As the demands of environment protection increase, the use of plastic materials have been restricted. On the other hand, Pulp mold products have some benefits - easy manufacturing, superior shock absorbing and eco-friendly. In order to develop pulp mold tray for melon packaging as shock absorbing packaging material, we investigated physical properties and vibration transmission characters of 180, 200 and 220 g pulp mold tray for melon. As the weight of pulp increased, compression strength and shock absorbing performance increased, while vibration transmissibility decreased. Especially in case of 180g pulp mold tray, it is not suitable for melon packaging because the transmitted vibration acceleration was higher than the forced vibration acceleration. And 200g pulp mold tray is suitable for melon packaging because the vibration transmissibility was lowest in three trays. And the vibration acceleration transmitted to the melon in edge of pulp mold tray was higher than to the melon in center of pulp mold tray. As the result of the simulated transportation test, the firmness of melon packaging using pulp mold tray was higher than that of conventional packaging. Therefore, these results suggest that pulp mold tray packaging could be suitable for melon packaging.

  • PDF

A Study on the Evaluation Technique of Damage of Metal Matrix Composite Using X-Ray Fractography Method (X선 프렉토그래피기법을 이용한 금속복합재료의 피로손상 해석에 관한 연구)

  • Park, Young-Chul;Yun, Doo-Pyo;Park, Dong-Sung;Kim, Deug-Jin;Kim, Kwang-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.3
    • /
    • pp.172-180
    • /
    • 1998
  • It is attempted to verify the Quantitative relationship between fracture mechanical parameters (${\Delta}K$, $K_{max}$) and X-ray parameters (residual stress, half-value breadth) of A12009-15v/o $SiC_w$ composite, and normalized SS41 steel. In this study, fatigue crack propagation test were carried out and X-ray diffraction was applied to fatigue fractured surface in order to investigate the change of residual stress and half-value breadth on fatigue fractured surface. And it is loaded prestrain to each tensile specimen, A12009-15v/o $SiC_w$ composite(0.3, 0.5, 1, 1.5, 2%) and normalized SS41 steel(0.63, 2.25, 7.50, 13.7, 20%), for investigating plastic strain rate using nondestructive measurement method. X-ray diffraction was applied to the prestrained tensile specimens in order to measure the change of residual stress and half-value breadth.

  • PDF

Role and Prognosis of Extracorporeal Life Support in Patients Who Develop Cardiac Arrest during or after Office-Based Cosmetic Surgery

  • Kwon, Seong Soon;Park, Byoung-Won;Lee, Min-Ho;Bang, Duk Won;Hyon, Min-Su;Chang, Won-Ho;Oh, Hong Chul;Park, Young Woo
    • Journal of Chest Surgery
    • /
    • v.53 no.5
    • /
    • pp.277-284
    • /
    • 2020
  • Background: Cardiac arrest during or after office-based cosmetic surgery is rare, and little is known about its prognosis. We assessed the clinical outcomes of patients who developed cardiac arrest during or after cosmetic surgery at office-based clinics. Methods: Between May 2009 and May 2016, 32 patients who developed cardiac arrest during or after treatment at cosmetic surgery clinics were consecutively enrolled. We compared clinical outcomes, including complications, between survivors (n=19) and non-survivors (n=13) and attempted to determine the prognostic factors of mortality. Results: All 32 of the patients were female, with a mean age of 30.40±11.87 years. Of the 32 patients, 13 (41%) died. Extracorporeal life support (ECLS) was applied in a greater percentage of non-survivors than survivors (92.3% vs. 47.4%, respectively; p=0.009). The mean duration of in-hospital cardiopulmonary resuscitation (CPR) was longer for the non-survivors than the survivors (31.55±33 minutes vs. 7.59±9.07 minutes, respectively; p=0.01). The mean Acute Physiology and Chronic Health Evaluation score was also higher among non-survivors than survivors (23.85±6.68 vs. 16.79±7.44, respectively; p=0.01). No predictor of death was identified in the patients for whom ECLS was applied. Of the 19 survivors, 10 (52.6%) had hypoxic brain damage, and 1 (5.3%) had permanent lower leg ischemia. Logistic regression analyses revealed that the estimated glomerular filtration rate was a predictor of mortality. Conclusion: Patients who developed cardiac arrest during or after cosmetic surgery at office-based clinics experienced poor prognoses, even though ECLS was applied in most cases. The survivors suffered serious complications. Careful monitoring of subjects and active CPR (when necessary) in cosmetic surgery clinics may be essential.

The Influence of Insulation Wraps on the Temperature Change of Kiwifruit Trunk Surface During Winter (월동 피복재 종류에 따른 참다래 주간부 표면 온도변화)

  • Kwack, Yong-Bum;Kim, Hong Lim;Kim, Seong-Cheol;Kim, Mok-Jong;Lee, Yong-Bok
    • Korean Journal of Environmental Agriculture
    • /
    • v.33 no.4
    • /
    • pp.403-408
    • /
    • 2014
  • BACKGROUND: Kiwifruit is a warm-temperate, deciduous fruit tree. It is sensitive to frost or freeze damage during winter. Therefore, the farmers cover kiwifruit trunk with rice straw to preclude freeze injury. This study was conducted to evaluate trunk wraps for protection of freeze injury of kiwifruit (Actinidia deliciosa) vines. METHODS AND RESULTS: The experimental orchard was located in Sacheon (lat. $34^{\circ}56'N$, long. $128^{\circ}03'E$) of Gyeongsangnam-do, South Korea. The vines were 5-6-year-old 'Hayward'. Two wrap materials, rice straw and silver-cushioned mat (reflective foil-coated, plastic-foamed mat, Ganan Industry, Rep. of Korea) were evaluated for their heat-retaining ability. The trunks of kiwifruit vines were wrapped in late December, and the wraps were removed in mid-April the following year (2012/13 and 2013/14). Temperature inner wraps were recorded from January to March in 2013 and 2014 by WatchDog 2450 (Spectrum Technologies, Inc., USA). In 2013, the lowest ambient temperature of January and February was $-10.2^{\circ}C$, $-10.9^{\circ}C$, respectively. The lowest temperature of inner-wrap of silver -cushioned mat was $-6.3^{\circ}C$, $-2.6^{\circ}C$ in January and February, respectively. However, rice straw showed $-9.8^{\circ}C$ and $-9.9^{\circ}C$ in its lowest value of January and February. And also silver cushioned mat appeared to be superior to rice straw in its ability of heat-retaining during night time.

Physical and Mechanical Properties of Cements for Borehole and Stability Analysis of Cement Sheath (관정 시멘팅 재료의 물리역학물성 및 시멘트층의 안정성 분석)

  • Kim, Kideok;Lee, Hikweon;Kim, Taehee;Kim, Gyo-Won
    • The Journal of Engineering Geology
    • /
    • v.26 no.1
    • /
    • pp.101-115
    • /
    • 2016
  • We carried out laboratory material tests on two cements (KS-1 ordinary Portland and Class G) with changing W/S (Water/Solid) and the content of fly ash in order to evaluate their physical and mechanical properties. The specimens of KS-1 ordinary Portland cement were prepared with varying W/S (Solid=cement) in weight, while those of Class G cement were prepared with changing the content of fly ash in volume but maintaining W/S (Solid=cement+fly ash). The results of the material tests show that as the W/S in KS-1 ordinary Portland cement and the content of fly ash in Class G cement increase, the properties (density, sonic wave velocity, elastic constants, compressive and tensile strengths, thermal conductivity) decrease, but porosity and specific heat increase. In addition, an increase in confining pressure and in the content of fly ash leads to plastic failure behavior of the cements. The laboratory data were then used in a stability analysis of cement sheath for which an analytical solution for computing the stress distribution induced around a cased, cemented well was employed. The analysis was carried out with varying the injection well parameters such as thickness of casing and cement, injection pressure, dip and dip direction of injection well, and depth of injection well. The analysis results show that cement sheath is stable in the cases of relatively lower injection pressures and inclined and horizontal wells. However, in the other cases, it is damaged by mainly tensile failure.

IN VITRO DETERMINATION & QUANTIFICATION OF HYDROGEN PEROXIDE PENETRATION DURING NONVITLAL BLEACHING (무수치 표백시술시 치경부를 통한 표백제 누출량의 정량적 측정)

  • Park, Soo-Kyeong;Lee, Chung-Sik;Choi, Han-Seuk
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.1
    • /
    • pp.19-34
    • /
    • 1996
  • It has been demonstrated that intracoronal bleaching of pulpless teeth may result in cervical root resorption. Several authors postulated that bleaching agents such as hydrogen peroxide penetrated through the dentinal tubules to damage the surrounding tissues that cause cervical root resorption. The purpose of this study was to suggest on in vitro model for direct determination of hydrogen peroxide penetration through CEJ during nonvital bleaching. In addition, this model permit the quantification of the amount of hydrogen peroxide penetrated during the procedure. Freshly extracted intact premolars, removed for orthodontic reasons were used. Root canal treatment was performed in each tooth. And then the outer surface and crown portion of the teeth was sealed with wax leaving the CEJ. The prepared teeth mounted on the wax laminates were placed in plastic assay tubes containing 1.5ml bidistilled water with their entire root, including the CEJ, submerged in the solution. The teeth were dividied into four groups. Thermo group : thermocatalytic bleaching with superoxol Walk group: walking bleaching with sodium perborate & superoxol Combi group : combination of thermocatalytic & walking bleaching Dw group : walking bleaching with sodium perborate & water The bleaching procedure was performed three times. The bleaching intervals were at 3 days. The hydrogen peroxide present in the assay system was added to ferrous ammonium sulfate resulting in ferric ion release. Upon the addition of potassium thiocyanate a ferrithiocyanate complex results, which absorbs light at the wavelength of 467nm. The radicular penetration of hydrogen peroxide in the four groups was assessed directly using spectrophotometer. The amount of hydrogen peroxide in the samples tested is determined by comparing them with a standard curve generated by known amounts of hydrogen peroxide. The results were obtained as follows : 1. In all experimental groups except the Dw group showed lower penetration amount in day 4 than day 1, there was statistical importance in the difference (P<0.05). 2. After 3rd treatment, Thermo group showed slightly increased value and narrow distribution. Walk group showed much more penetration amount and widely dispersed value. Value of Combi group showed wide distribution without regard to treatment time, but value of Dw group evenly distributed. 3. Thermo group, Walk group and Dw group showed a tendency of increasing penetration amount with increasing treatment times(P<0.01), but Combi group revealed no statistically important differences. 4. Combi group showed the highest degree of penetration. Walk group showed lower penetration than Combi group. Thermo group & Dw group showed lower than Walk group. 5. Cervical root permeability to hydrogen peroxide varied from 0 to 35 %.

  • PDF

A Survey on the Consumer Packaging Preferences for Mini Pot Flower Plants on Domestic Market in Korea (소형 분화류의 포장재 및 포장용기에 대한 소비자의 기호도 조사)

  • Lee, Sun Yup;Woo, Hyun Jeong;Lee, Youn Suk
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.23 no.1
    • /
    • pp.47-53
    • /
    • 2017
  • In this study we surveyed the preferences of consumer packaging for mini pot flower plants to improve the flower market application in Korea. The surveys were consisted of the consumers residing in Seoul metropolitan (221), Gyeonsang (70), Jeonla (29), Chungceong (19), Gangwon (7), other provinces (3). A total of 349 eligible respondents (male 173, female 176) were surveyed with a self-administered questionnaire asking on the general characteristics for residents, packaging material, packaging design, type of flower pot, degree of transparency, convenience, consumer's demand for packaging development, a significant point when purchasing the flower pot product. The collected date was analyzed using a chi-square (${\chi}^2$) statistical test in SPSS program. Most residents prefer for mini pot flower plants packed with packaging characteristics of plastic material (56.4%), packaging design of separated type (76.2%), angled type (62.5%), and transparency (48.6%). The other question results showed that major consumer's demand for mini pot flower plants is maintaining the freshness quality and stability structure for them. Transparency of packaging can also affect directly the preferences for purchasing the mini pot flower plants. The packaging structure with a proper shape design may protect the fresh mini pot flower plants from shock or any other damage during distribution. The results of this study help to provide consumer's demand for packaging development and to give the greatest advantages in terms of production and marketability of mini pot flower plants.